Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (2213) (entfernen)
Sprache
- Englisch (1681)
- Deutsch (514)
- Mehrsprachig (8)
- Spanisch (5)
- Französisch (3)
- Russisch (2)
Referierte Publikation
- nein (2213) (entfernen)
Schlagworte
- Fluorescence (65)
- Nanoparticles (65)
- Concrete (64)
- LIBS (62)
- Synchrotron (48)
- NDT (47)
- Zerstörungsfreie Prüfung (46)
- Ultrasound (39)
- XRF (39)
- Nanoparticle (38)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (531)
- 1 Analytische Chemie; Referenzmaterialien (498)
- 6 Materialchemie (404)
- 8.0 Abteilungsleitung und andere (148)
- 6.1 Oberflächen- und Dünnschichtanalyse (137)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (126)
- 1.4 Prozessanalytik (122)
- 8.4 Akustische und elektromagnetische Verfahren (115)
- 1.1 Anorganische Spurenanalytik (113)
- 6.3 Strukturanalytik (98)
The design of sample flow cells, commonly used in online analytics and especially for medium resolution NMR spectroscopy (MR-NMR) in low magnetic fields, was experimentally and theoretically investigated by 1H-NMR and numerical simulations. The flow pattern was characterised to gain information about the residence time distribution and mixing effects. Both 1H-NMR imaging and spectroscopy were used to determine the characteristics of flow cells and their significance for on-line measurements such as reaction monitoring or hyphenated separation spectroscopy. The volume flow rates investigated were in the range from 0.1 to 10 ml/min, typically applied in the above mentioned applications. When compared to those commonly used in high-field NMR, the special characteristics of flow cells for MR-NMR were revealed by various NMR experiments and compared with CFD simulations. The influence of the design of the inlet and outlet on the flow pattern was investigated as well as the effect of the length of the cell. For practical use, a numerical estimation of the inflow length was given. In addition, it was shown how experiments on the polarisation build-up revealed insight into the flow characteristics in MR-NMR.
Online NMR spectroscopy is an excellent tool to study complex reacting multicomponent mixtures and gain process insight and understanding. For online studies under process conditions, flow NMR probes can be used in a wide range of temperature and pressure. This paper compiles the most important aspects towards quantitative process NMR spectroscopy in complex multicomponent mixtures and provides examples. After NMR spectroscopy is introduced as an online method and for technical samples without sample preparation in deuterated solvents, influences of the residence time distribution, pre-magnetization, and cell design are discussed. NMR acquisition and processing parameters as well as data preparation methods are presented and the most practical data analysis strategies are introduced.
Reliable analysis of chemical indicators in water, sediment and soil samples for the purpose of environmental pollution assessment poses one of the greatest analytical challenges, having in mind the complexity of sample matrix and low concentrations of pollutants. Organics (pesticides, PAHs, PCBs, etc.) and heavy metals (Hg, Cd, Ni, Pb and As) represent target parameters. Laboratories performing sampling and tests in this field regulated by respective EU directives [1], need strong support in terms of providing them with appropriate matrix CRMs enabling the process of quality control. NMIs and DIs with proven metrological capabilities for the production and certification of such materials are necessary for the provision of quality data. This project is aiming to develop capacity to produce CRMs for environmental analysis by transferring the theoretical and practical know-how between the partners and combining their skills to focus on environmental CRM production in accordance with ISO Guide 34 [2]. Production process includes good manufacturing practices for processing materials, method development and validation for homogeneity, stability and characterisation tests, characterisation of selected analytes together with additional information about matrix constituents, the calculation of individual uncertainties (between units inhomogeneity, long term stability, characterisation) and combination of uncertainties to determine overall uncertainty of the matrix reference materials. Inter laboratory comparison registered as EURAMET project is set as the ultimate project outcome, confirming the partners’ capabilities in applying newly acquired skills.
Resolving overlapping peaks of multiple components. Relative primary analytical method - Fundamental relationship of qNMR.
Troubleshooting Samples Analytics:
Impurities in products: unexpected & unwanted occurrence, unknown identity, analytical method unclear, often various analytical methods, necessary, short response time important (< 1 d), benefits: allocation of its source within hours safes cost
• Investigations planned, coordinated and documented by TSA team
• Variety of analytical methods available
In recent years, elemental imaging of biological samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining in importance. Latest improvements regarding spatial resolution (down to 1 µm) and washout time make LA-ICP-MS particularly interesting for single cell analysis.
Many current nanomaterials can serve as contrast agents in cellular or tissue imaging, drug delivery vehicles or therapeutics, whereas others can cause toxic effects. In order to evaluate nano-bio interactions, the number of nanoparticles (NPs) inside cells as well as their localisation within cellular substructures is of particular interest.
LA-ICP-MS was used to study the NP pathway from uptake, via intracellular processing up to cell division. Fibroblast cells were incubated with different metallic NPs under varying experimental conditions. For LA analysis the cells were fixed with formaldehyde and dried.
Our results show that LA-ICP-MS is able to localise NP aggregates within cellular substructures. The NPs accumulate in the perinuclear region in the course of intracellular processing, e.g. multivesicular fusion and endosomal maturation, but do not enter the nucleus [1, 2]. A strong dependence of NP uptake on concentration and incubation time was found. Additionally, the number of NPs internalized by individual cells was determined and variations within the cell population became visible.
A new laser ablation system providing a short washout time (50 ms) together with small spot sizes (< 4 µm) and high repetition rates allows high spatial resolution applications. First results of cell imaging will be shown.
The findings demonstrate the potential of LA-ICP-MS enabling insight into NP uptake and intracellular distribution dependent on experimental parameters.
Excelling in brevity but lacking in applicability, the 2011 EU nanomaterial definition has become a source of anguish for scientists and industry alike. Repeated pleas and discussions with our own envoy have demonstrated the strength of their resolve: this definition is unlikely to change. Manufacturers of many materials (cosmetics, pigments, foodstuffs, etc.) will have to characterise and label all their products accordingly, a task still impossible for lack of a clear metrological approach towards this goal. Therefore, the onus has fallen on the scientists to come up with a practicable measurement technique allowing inexpensive classification covering large swathes of the material landscape. Small-angle X-ray Scattering (SAXS) probes the size range in question, and can - with due care - deliver a bulk-averaged volume-weighted size distribution. Like any other real-world measurement method, however, it is not (and can never be) a universal solution. This presentation will clarify the SAXS technique, provide several application examples for nanomaterial characterisation, and will detail the limitations and pitfalls that accompany its abilities. At the end of this presentation, you will have the information to judge whether the technique is amenable to your materials or not.
Thermoresponsive polymers have shown great potential in applications such as bioseparation, drug delivery and diagnostic. Only few thermoresponsive polymers that present an upper critical solution temperature (UCST) in a relevant temperature range, i.e. phase separate from solution upon cooling, have been reported so far. Moreover, the most studied UCST type polymers namely polybetaines are difficult to use under physiological conditions, which significantly restricts their potential applications. Therefore, UCST polymers with sharp and robust phase transition in physiological conditions (in the presence of salts, ions etc.) are highly needed in order to extend the range of applications of this class of polymers. Herein, a robust UCST-type copolymer of acrylamide (AAm) and acrylonitrile (AN) (poly(AAm-co-AN)) was prepared by reversible addition fragmentation chain transfer (RAFT) polymerization and its thermo-induced aggregation behavior in aqueous media was studied. At temperature below the UCST, the copolymer chains were aggregated together. The aggregate size was found to be larger with increasing AN contents and became smaller upon dilution of the copolymer solutions. While above the UCST, the copolymer chains were expanded and weekly associated in solution. The association between the copolymer chains formed smaller aggregates with increasing the AN contents or the dilution of the solutions. A model is proposed to explain such aggregation-association behavior of the Fig. 1.
Figure 1. Schematic illustration of the proposed thermos-induced aggregation behavior of the poly(AAm-co-AN) in aqueous solution.
This lecture is an introduction to ICP-MS with a double focusing magnetic sector mass analyzer. It offers fundamental background, a thorough discussion of analytical features, and state of the art information on applications. Different types of double focusing instruments also are considered. Specific topics include fundamental aspects of ICP-MS (physical properties of a double focusing instrument, operational characteristics in comparison with quadrupole instruments); analytical characteristics (spectral and non-spectral interferences, figures of merit in low and high resolution modes, blanks and memory effects, HPLC and GC interfaces), and applications (industrial including ultra-pure reagents and alloys, environmental, geological, and biomedical materials).
The presentation gave an overview of the topic, the aims and the task allocation of the M-ERA.NET founded project named “Nanohype”.
In this project four research teams working hand in hand on computational modeling, synthesis and experimental validation to design novel metal-shelled Upconversion-NP combining plasmonic interactions.
As Ph.D. student at the BAM I am responsible for the optical characterization (measurements of lifetimes, Quantum Yields and PL emissions ) of these promising novel systems.
Analytical methods require efficient and versatile strategies to measure an increasing number of analytes that can be used in conjunction with established platforms like flow cytometry. Spectral multiplexing suffers from problems such as spectral crosstalk and often requires different excitation light sources increasing instrumentation costs. Thus, the number of distinguishable reporters with intensity-based barcodes is limited. An alternative can be lifetime encoding for discrimination of fluorophores based on their fluorescence decay kinetics.
We report on the suitability of µm-sized polymer particles stained with organic dyes for lifetime encoding. These dyes are excitable at a standard laser diode wavelength and detectable within a single spectral window. For lifetime-based discrimination, these dyes display sufficiently different luminescence decay kinetics. We present the spectroscopic properties of these beads and address challenges like the limited number of detectable photons in a flow for the reliable discrimination. These studies are expected to pave the road to new applications of fluorescence lifetime multiplexing for time-domain flow cytometry.
Industrial quality control (QC) nowadays requires the visualization of surface modifications from the macro-scopic to the microscopic or even nanoscopic scale. This is a prerequisite to the evaluation of functionality and reliability, the detection of defects and their separation of artefacts. The diversity of applications ranges from low-E glazings and solar panels, micro- and optoelectronics, micro- and smart devices to sensor-on-chip and lab-on-chip systems [1]. Optical microcopy (light, confocal laser scanning, white light interference) as established QC-tool is operated at normal incidence, i.e. p- and s-polarization are undistinguishable. Either light-intensity in terms of grey scale and colour or intensity-correlated effects of phase shifts are used. In case of ellipsometry, operated at oblique incidence, p- and s-polarization matter, and amplitude ratios and phase shifts upon reflection are measured. Hence, information content must be much higher.
The visualization of surface modifications may be very challenging for coating/substrate systems of either al-most identical optical constants, e.g. transparent films on substrates of the same material, or minor film thick-ness, substance quantity and affected area, e.g. ultra-thin or island films. Ellipsometry gives access to the con-trast of intensity (I), amplitude ratio (Ψ), and phase shift (Δ) with nanometer-scaled vertical and micrometer-scaled lateral sensitivity, one is able to identify tiny changes within an unmodified surface. As both mapping ellipsometry (ME) and imaging ellipsometry (IE) are operated in the optical far-field, surface inspection is also possible on the macroscopic scale. Near the Brewster-angle of the bare, undamaged, clean, and fresh substrate, the contrast to add-on and sub-off features is superior.
Fig. 1 shows three examples of ellipsometric imaging, i.e. a thin SnO:Ni film on SiO2/Si (Fig. 1a), a dried stain of an anti-body solution on cyclo-olefin-polymer (COP) shown in Fig. 1b, and a polyimide film residue on SiO2/Si (Fig. 1c). For all of these examples, ellipsometry provides much better contrast between substrate and surface modification than optical microscopy, sometimes primarily caused by the oblique incidence (Figs. 1a and 1c), in other cases related to the phase sensitivity of ellipsometry (Fig. 1b). Other examples are laser surface modifications and the corrosion of glass. In these cases, optical microscopy and IE yield to similar results, how-ever only ellipsometry gives access to modelling.
Further investigated coating/substrate systems are 100Cr6 steel, native oxide on silicon, borosilicate glass, and the polymer polycarbonate with deposited films of graphene and ta-C:H, printed and dried pattern of liquids such as water, cleaning agents, and dissolved silicone. Besides imaging ellipsometry, referenced spectral ellipsometry (RSE) has been applied, combining the advantages of both optical microscopy (fast measurement) and ellipsometry (high sensitivity to tiny modifications).
Photoluminescence techniques are amongst the most widely used tools in the material and life sciences, with new and exciting applications continuously emerging, due to their many advantages like comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. Drawbacks are , however, signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are time-dependent due to the aging of instrument components, and difficulties to measure absolute fluorescence intensities. Thus, there is a considerable need for standards for intensity, spectral, and temporal fluorescence quantities to meet the increasing need for instrument performance validation and global trends to harmonize physicochemical measurements. In this respect, instrument calibration strategies together with different types of fluorescence standards are presented as well as design concepts for robust, easy-to-use, and format-adaptable fluorescence standards useable for the determination of different fluorescence parameters and a broad variety of fluorescence techniques.
Gas sensors are an important tool in various areas for example in industrial process control as well as Gas sensors are an important tool in various areas for example in industrial process control as well as safety applications or in research. A useful gas detector should be selective, precise, stable and cost-effective. In the present research a surface based gas detection technique is investigated using the SPR effect with ellipsometric readout. This technique is called surface plasmon resonance enhanced ellipsometry (SPREE).
The sensor consists of a gold layer (40 nm) top-coated with a doped metal-oxide (M:SnOₓ,
5 nm). The coating is added by magnetron sputtering with doped targets with different doping concentrations. It could be shown that, without the top-coating, these type of sensors can detect various gases, e.g. CO, H2, O2, O3, He, N2, with sensitivities down to the ppm range (in air).
The goal of the present study is to characterize the additional coating materials in dependence of the coating conditions. With the help of the doped-metal oxide, the sensitivity increases dramatically by a factor of 100. Additionally, a selectivity for specific gases is observed which depends on the doping conditions of the coating. Changing the properties of the plasma coating process and the doping metal gives access to a variety of different layers and enables us to find the best conditions.
Permeability estimation from spectral induced polarization (SIP) measurements is based on a fundamental premise that the characteristic relaxation time (t) is related to the effective hydraulic radius (reff) controlling fluid flow. The approach requires a reliable estimate of the diffusion coefficient of the ions in the electrical double layer. Others have assumed a value for the diffusion coefficient, or postulated different values for clay versus clay-free rocks. We examine the link between t and reff for an extensive database of sandstone sampleswhere mercury porosimetry data confirm that reff is reliably determined from a modification of the Hagen-Poiseuille equation assuming that the electrical tortuosity is equal to the hydraulic tortuosity. Our database does not support the existence of 1 or 2 distinct representative diffusion coefficients but instead demonstrates strong evidence for 6 orders of magnitude of variation in an apparent diffusion coefficient that is well correlated with both reff and the specific surface area per unit pore volume (Spor). Two scenarios can explain our findings: (1) the length-scale defined by t is not equal to reff and is likely much longer due to the control of pore surface roughness; (2) the range of diffusion coefficients is large and likely determined by the relative proportions of the different minerals (e.g. silica, clays) making up the rock. In either case, the estimation of reff (and hence permeability) is inherently uncertain from SIP relaxation time.