Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (2213) (entfernen)
Sprache
- Englisch (1681)
- Deutsch (514)
- Mehrsprachig (8)
- Spanisch (5)
- Französisch (3)
- Russisch (2)
Referierte Publikation
- nein (2213) (entfernen)
Schlagworte
- Fluorescence (65)
- Nanoparticles (65)
- Concrete (64)
- LIBS (62)
- Synchrotron (48)
- NDT (47)
- Zerstörungsfreie Prüfung (46)
- Ultrasound (39)
- XRF (39)
- Nanoparticle (38)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (531)
- 1 Analytische Chemie; Referenzmaterialien (498)
- 6 Materialchemie (404)
- 8.0 Abteilungsleitung und andere (148)
- 6.1 Oberflächen- und Dünnschichtanalyse (137)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (126)
- 1.4 Prozessanalytik (122)
- 8.4 Akustische und elektromagnetische Verfahren (115)
- 1.1 Anorganische Spurenanalytik (113)
- 6.3 Strukturanalytik (98)
Imuno-histochemical staining (IHC) of cancer biomarker on tissue sections is one of the most important analytical techniques for cancer diagnosis although standardization and quality management is tedious and differ significantly from clinic to clinic. Combining established IHC staining strategies with modern quantitative methods would increase it`s potential. We used element mass spectrometry (ICP-MS) and a new ink-jet printed internal standardization approach in combination with IHC staining. The printing strategy was utilized to improve elemental image resolution and reproducibility of paraffin embedded breast cancer tissue sections in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) after conventional IHC staining as a model system to investigate the new capabilities of this technique.
Thermoresponsive polymers have shown great potential in applications such as bioseparation, drug delivery and diagnostic. Only few thermoresponsive polymers that present an upper critical solution temperature (UCST) in a relevant temperature range, i.e. phase separate from solution upon cooling, have been reported so far. Moreover, the most studied UCST type polymers namely polybetaines are difficult to use under physiological conditions, which significantly restricts their potential applications. Therefore, UCST polymers with sharp and robust phase transition in physiological conditions (in the presence of salts, ions etc.) are highly needed in order to extend the range of applications of this class of polymers. Herein, a robust UCST-type copolymer of acrylamide (AAm) and acrylonitrile (AN) (poly(AAm-co-AN)) was prepared by reversible addition fragmentation chain transfer (RAFT) polymerization and its thermo-induced aggregation behavior in aqueous media was studied. At temperature below the UCST, the copolymer chains were aggregated together. The aggregate size was found to be larger with increasing AN contents and became smaller upon dilution of the copolymer solutions. While above the UCST, the copolymer chains were expanded and weekly associated in solution. The association between the copolymer chains formed smaller aggregates with increasing the AN contents or the dilution of the solutions. A model is proposed to explain such aggregation-association behavior of the Fig. 1.
Figure 1. Schematic illustration of the proposed thermos-induced aggregation behavior of the poly(AAm-co-AN) in aqueous solution.
Imuno-histochemical staining (IHC) of cancer biomarker on tissue sections is one of the most important analytical techniques for cancer diagnosis although standardization and quality management is tedious and differ significantly from clinic to clinic. Combining established IHC staining strategies with modern quantitative methods would increase it`s potential. We used element mass spectrometry (ICP-MS) and a new ink-jet printed internal standardization approach in combination with IHC staining. The printing strategy was utilized to improve elemental image resolution and reproducibility of paraffin embedded breast cancer tissue sections in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) after conventional IHC staining as a model system to investigate the new capabilities of this technique.
The motivation to examine the influence of friction on surfaces of energetic materials (EM) has diverse backgrounds. On the one hand the very old hot spot theory predicts, that the size of such hot spot could be in the range of a molecule. The initiation of an EM could start by mechanical excitation, i.e. friction, and continues driven by an exothermal chemical reaction. Following such phenomena on the molecular scale with an imaging method such as AFM should enable us to separate several steps of ignition, if there are any. The experiments showed that HMX mainly undergoes a plastic deformation without further consequences. TNP however showed self healing in the wear track after scratching and simultaneously the destruction of a crystal edge outside the wear track. Additionally nanoparticles appear, tribologists call this "third body formation", which are proven to have a different chemical composition as the original TNP. The self healing effect on the surface is verified with experiments on self diffusion of TNP molecules to and fro the free edges of the crystal. The conclusion is that the formation of a hot spot can be shown to consist of several subsequent steps, separated temporally and locally. The goal to excite the thermal decomposition of a whole TNP crystal (nanoexplosion) was yet not reached due to unfavourable conditions related to thermal conductivity and build-up of pressure.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Inhalt des Vortrags sind die Einführung und Erläuterung der Ziele und Inhalte der Technologie-Roadmap „Prozesssensoren 4.0“, welche von der NAMUR im November 2015 veröffentlicht wurde. Dazu werden Beispiele von aktuellen und zukünftigen Anwendungen erläutert.
Derzeit finden gravierende Veränderungen im Umfeld der Informations- und Kommunikationstechnik statt, die eine große Chance für die optimierte Prozessführung und Wertschöpfung mit darauf abgestimmten vernetzt kommunizierenden Sensoren bieten. Diese Art „smarter“ Sensoren stellen Dienste innerhalb eines Netzwerks bereit und nutzen Informationen daraus. Dadurch ergibt sich aktuell die Notwendigkeit, die Anforderungen an Prozesssensoren sowie an deren Kommunikationsfähigkeiten detaillierter zu beschreiben.
Vernetzte Sensoren sind die Voraussetzung für die Realisierung von Cyberphysischen Produktionssystemen (CPPS) und zukünftiger Automatisierungskonzepte für die Prozess-industrie.
Wesentliche Ziele der Roadmap sind das Zusammenbringen von Technologie- und Marktsicht, Analyse und Priorisierung des (zukünftigen) Informationsbedarfs in verfahrenstechnischen Prozessen, das Erarbeiten von Entwicklungszielen für neue Sensorik sowie das Aufzeigen möglicher Lösungsansätze und ihres Realisierungszeitraums. Darüber hinaus liefert sie Perspektiven für Forschungs- und Entwicklungsförderung und gibt Ansätze für die Normungsarbeit.
Silver nanoparticles (Ag NPs) are widely used in consumer products due to their excellent antibacterial properties. Their broad application has led to a variety of recent regulation on their use and labelling. Thus, a highly specific analytical method for their characterization and quantification is needed.
Due to their large separation range, field-flow fractionation (FFF) techniques are repeatedly applied for the analysis of NP. Limitations of FFF include quantification, sample loss and insufficient recovery rates. Another challenge can be non-ideal elution behavior of particles in complex and unknown matrices.
The possible sources for sample losses of Ag NP have been studied using an asymmetric flow FFF (AF4) in combination with inductively coupled plasma mass spectrometry (ICP-MS). The influence of different parameters, for example the sample concentration, on the recovery rates and sample loss has been investigated. Using laser ablation ICP-MS, the Ag deposition on the membrane was located and quantified. Our results identified ionic silver as the main sources of sample loss. These results can be useful for further method improvement.
However, when a Ag NP sample containing an unknown complex matrix is analyzed, FFF method optimization is challenging as the sample might show a shift in the retention times and lower recovery rates. In this case, ICP-MS experiment in the single particle mode (sp-ICP-MS) can be a useful addition to the FFF measurement. Here, upon assumption of spherical particles, the geometric diameters can be calculated. This fast and easy approach can be helpful in order to interpret the FFF fractograms and advice the FFF method optimization process.
Recent technical developments of NMR instruments such as in acquisition electronics and probe design allow detection limits of components in liquid mixtures in the lower ppm range (approx.. 5–10 ppm amount of substance). The major advantage of quantitative NMR spectroscopy (qNMR) is that it is a direct ratio method of analysis without the need of calibration. This means that the signal for a specific NMR-active nucleus (e.g., a proton) in an analyte can be compared and quantified by reference to a different nucleus of a separate compound, comparable to a counting of spins in the active volume of the spectrometer.
Technical mixtures can be investigated online directly next to a process setup by using flow probes. This makes it a promising method for process analytical applications, especially during process development in laboratory and pilot plant scale. With the growing market of Benchtop devices based on permanent magnets nowadays an integration of NMR spectroscopy in an industrial environment becomes reasonable.
A special application of qNMR in technical mixtures is the observation in the gas phase, which is rarely applied compared to liquid and solid NMR studies. Because of the low density it results in a reduced sensitivity, which can be improved by applying pressure. Therefore a high-pressure NMR setup was developed based on a commercially available NMR tube made of zirconia. This is currently tested up to 20 MPa, but can be extended up to 100 MPa with regard to pressure rating of its components. This work shows results of gas-phase application on natural-gas like reference gas mixtures produced at BAM, as well as investigations on liquefied gas mixtures with high accuracy provided in piston cylinders.
Besides that amine gas treatment and hydroformylation in a microemulsion represent two other examples of applications in process analytical technology. These show the potential of combination of online NMR spectroscopy with other spectroscopic methods, especially during model development for data evaluation.
Since the advent of industrial computed tomography (CT), this new analysis method has been used also for the investigation of objects of cultural heritage and art. CT provides the possibility to determine the inner and outer surfaces and to investigate the material structure without causing damage to the valuable objects.
In this talk I will present examples of measurements performed at BAM, which demonstrate what CT can do for objects of diverse materials and for different objectives.
Due to recent advances in technical developments of NMR instruments such as acquisition electronics and probe design, detection limits of components in liquid mixtures were improved into the lower ppm range (approx. 5–10 ppm amount of substance). This showed that modern NMR equipment is also suitable for the observation of hydrocarbon samples in the expanded fluid phase or gas phase. Since Quantitative NMR spectroscopy (qNMR) is a direct ratio method of analysis without the need of calibration it was used to determine impurities in appropriate liquid and liquefied hydrocarbon isomers up to C6, which are used for preparation of primary gas standards, e.g., natural gas or exhaust gas standards. At the same time it is possible to yield structural information with a minimum of sample preparation. Thus, cross contaminations between different isomers of the observed hydrocarbons and their (NMR-active) impurities can be identified and quantified.
In general, most quantitative organic chemical measurements rely on the availability of highly purified compounds to act as calibration standards. The traceability and providence of these standards is an essential component of any measurement uncertainty budget and provides the final link of the result to the units of measurement, ideally the SI. The more recent increase in the use of qNMR for the direct assessment of chemical purity however can potentially improve the traceability and reduce the uncertainty of the measured chemical purity at a reduced cost and with less material. For example the method has beneficially been used by National Measurement institutes for recent CCQM comparisons including the CCQM–K55 series of purity studies.
Traditional ‘indirect’ methods of purity analysis require that all impurities are identified and quantified, leading to a minimum of 4 individual analytical methods (organic impurities, water, solvents, inorganic residue). These multiple technique approaches measure an array of different chemical impurities normally present in purified organic chemical compounds. As many analytical methodologies have compound-specific response factors, the accuracy and traceability of the purity assessment is dependent on the availability of reference materials of the impurities being available.
qNMR provides the most universally applicable form of direct purity determination without need for reference materials of impurities or the calculation of response factors but only exhibiting suitable NMR properties. The development of CRMs addressing qNMR specific measurement issues will give analysts compounds ideally suited for the analytical method and also provide full characterisation of qNMR related parameters to enable more realistic uncertainty budgets. These materials will give users the tools to exploit qNMR more easily and enable them to speed up analytical method development and reduce the time and financial burden of multiple analytical testing.
Online NMR spectroscopy is an excellent tool to study complex reacting multicomponent mixtures and gain process insight and understanding. For online studies under process conditions, flow NMR probes can be used in a wide range of temperature and pressure. This paper compiles the most important aspects towards quantitative process NMR spectroscopy in complex multicomponent mixtures and provides examples. After NMR spectroscopy is introduced as an online method and for technical samples without sample preparation in deuterated solvents, influences of the residence time distribution, pre-magnetization, and cell design are discussed. NMR acquisition and processing parameters as well as data preparation methods are presented and the most practical data analysis strategies are introduced.
Troubleshooting Samples Analytics:
Impurities in products: unexpected & unwanted occurrence, unknown identity, analytical method unclear, often various analytical methods, necessary, short response time important (< 1 d), benefits: allocation of its source within hours safes cost
• Investigations planned, coordinated and documented by TSA team
• Variety of analytical methods available
Resolving overlapping peaks of multiple components. Relative primary analytical method - Fundamental relationship of qNMR.
CCQM has established a framework of comparisons to demonstrate the international comparability of chemical measurements. The key point is the establishment of comparable measurements, with traceability to internationally or nationally stated references. The Surface Analysis Working Group (SAWG) has been formally founded in 2003. CCQM ratified the group as a full working group of CCQM in April 2003 with these terms of reference:
- to develop pilot studies and carry out key comparisons of national measurement standards for surface and micro/nano-analysis;
- to assist in identifying and establishing inter-laboratory work to improve the traceability of surface and micro/nano-analysis;
- to establish and update a work plan to be adopted by CCQM;
- to discuss and review the scope of the working group and to liase with other working groups related to nanotechnology.
Following the 2015 meeting of the CCQM, the pilot study CCQM-P130 “WD and ED Electron Probe Micro Analysis on Au-Cu alloys” lead by BAM&NIST has been finalized. The Key Comparison K-129 “Measurement of atomic fractions in Cu(In,Ga)Se2 Films” lead by KRISS has made substantial progress and is about to be finalized. The new Key Comparison K-136 on “BET specific surface of ” lead by UNIIM&BAM has made strong progress in 2015 and will be finished in 2016.
Spray drying is a widely used process step in ceramic technology to
convert fine grained raw powders to free-flowing granules. Type and
amount of the organic additives (dispersants, binders and plasticizers)
define viscosity and stability of the slurry, the granulate structure and
the compaction behaviour.
Alumina and Zirconia powders were characterized with regard to
particle size, shape and specific surface area (BET). Zeta-potential
measurements by Stabino® were used to investigate the effect of
different dispersants on slurry stability. Unfortunately, this method is
restricted to suspensions with less than about 30% by weight of solid
content. The multi-sample analytical centrifuge LUMiSizer® overcomes
this problem. This device enables analysis of the separation behaviour
of suspensions over a wide range of solid content. On the basis of
position and time resolved photometric detection of transmitted light,
it is possible to determine the instability index, the sedimentation
velocity, and the sediment height in dependence of type and amount
of organic additives at various centrifugal accelerations. Additional
information is obtained from the shape of the transmission profiles.
Based on LUMiSizer® measurements, suitable additive concentrations
were derived. Thereby, the number of investigations by viscometry and
spray drying experiments can be significantly reduced.
Finally, it was possible to produce alumina, zirconia and ZTA aqueous
slurries with up to 80 weight-% of solid. The optimized suspensions
were successfully spray dried and the resulted granules show good
compaction behaviour.