Analytische Chemie
Filtern
Dokumenttyp
- Zeitschriftenartikel (77)
- Vortrag (65)
- Posterpräsentation (44)
- Sonstiges (7)
- Beitrag zu einem Tagungsband (2)
- Dissertation (2)
- Forschungsdatensatz (2)
- Buchkapitel (1)
Sprache
- Englisch (170)
- Deutsch (29)
- Mehrsprachig (1)
Schlagworte
- Immunoassay (42)
- ELISA (16)
- Diclofenac (15)
- Biosensor (13)
- Amperometry (12)
- Antikörper (12)
- Biosensoren (11)
- Amoxicillin (9)
- Antibody (9)
- Certified reference material (8)
Organisationseinheit der BAM
- 1.8 Umweltanalytik (200) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (65)
A frequently studied environmental contaminant is the active substance diclofenac, which is removed insufficiently in sewage treatment plants. Since its inclusion in the watch list of the EU Water Framework Directive, the concentrations in surface waters will be determined throughout Europe. For this, still, more precise analytical methods are needed. As a reference, HPLC-MS is frequently employed. One of the major metabolites is 4’-hydroxydiclofenac (4’-OH-DCF). Also, diclofenac lactam is important for assessing degradation and transformation. Aceclofenac (ACF), the glycolic acid ester of diclofenac is used as a drug, too, and could potentially be cleaved to yield diclofenac again. In various sewage treatment plant influent samples, diclofenac, 4’-OH-DCF, DCF lactam and ACF could be determined with detection limits of 3 µg/L, 0.2 µg/L, 0.17 µg/L and 10 ng/L, respectively.
Several works evaluated the toxicity of pharmaceutical drugs and climate related changes in invertebrates but few explored the combined effects of both stressors, namely considering their mode of action (MoA). Carbamazepine (CBZ) and cetirizine (CTZ) are pharmaceutical drugs detected in the environment and the toxicity derived from the combined effects of these drugs with ocean acidification (OA) is poorly explored. Thus, the present study investigated the biochemical parameters related to an oxidative stress response and the transcription of genes related to the MoA of CBZ (1.0 mg/L) and CTZ (0.6 mg/L) in the clam Ruditapes philippinarum chronically exposed (28 days) to control (7.8) and low (7.5) pH conditions. The results obtained showed that despite the clams accumulated both drugs, at low pH the clams exposed to CTZ decreased drug concentration and BCF values (CTZ uptake: 2.0 ± 0.5 ng/g fresh weight; BCF: 3.8 ± 0.9) in comparison with clams exposed to control pH (CTZ uptake: 2.9 ± 0.3 ng/g fresh weight; BCF: 5.5 ± 0.6). No oxidative stress was induced by the exposure to CBZ or CTZ at each pH level, but the transcription of several genes related with the MoA (neurotransmission, immunity and biomineralization) was altered by low pH, drug exposure and the combination of both stressors. At both pH conditions, CBZ increased the transcription of GABA receptor gene (neurotransmission) and CTZ led to a decrease of Perlucin gene (biomineralization) transcription. The transcription of MyD88 gene (immunity) decreased at low pH (7.5) combined with drug exposure (CBZ or CTZ). Thus, it was highlighted that the interaction of drug exposure and low pH conditions can change bivalves’ sensitivity to drugs or alter drugs toxicity.
Equipping ZIF particles with a polyelectrolyte membrane provides functional groups at their interface, enabling further conjugations necessary for applications such as targeted drug delivery. Previous approaches to coat ZIF particles with polyelectrolytes led to surface corrosion of the template material. This work overcomes previous limitations by performing a Layer-by-Layer (LbL) polyelectrolyte coating onto ZIF-8 and ZIF-67 particles in nonaqueous environment. Using the 2-methylimidazolium salt of polystyrensulfonic acid instead of the acid itself and polyethyleneimine in methanol led to intact ZIF particles after polyelectrolyte coating. This was verified by electron microscopy. Further, zetapotential and atomic force microscopy measurements confirmed a continuous polyelectrolyte multilayer built up. The here reported adaption to the well-studied (LbL) polyelectrolyte selfassembly process provides a facile method to equip ZIF particles with a nanometer thin polyelectrolyte multilayer membrane.
Monitoring water quality regarding emerging pollutants, such as drug residues, demands for selective, high-throughput and multi-target analytical methods. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affinity and specificity of target recognition by antibodies. Batch-wise processing in microtiter plates allows for the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex Suspension Array Fluorescence Immunoassay (SAFIA), which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core silica-shell microparticles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica shell creates a solid-support for the immunoassay: the target analytes, three drugs, carbamazepine, diclofenac and caffeine, and the fecal marker isolithocholic acid are covalently coupled to amino groups on the surface via NHS chemistry. Specific recognition of these haptens is accomplished by further introduction of PEG moieties, suppressing non-specific binding. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure, eliminating the demand for laborious washing steps and decreasing time-to-result. An automated flow cytometer is used for simultaneous decoding and quantification.
After optimization, the SAFIA showed limits of detection for all analytes in the low µg L 1 range, meeting the sensitivity criteria for wastewater analysis. Then, applicability of the SAFIA was studied on real wastewater samples from three different wastewater treatment plants in Berlin. The results were in good comparability to LC-MS/MS indicating high matrix stability. Moreover, the accuracy of the assay exceeded that of the respective ELISA. Finally, we used SAFIA to assess the influent of treated and untreated wastewater on the Douro river estuary in Portugal. The obtained results of the analysis were comparable to ELISA. However, the measurements by SAFIA could be carried out in one quarter the time of analysis required for ELISA.
Acknowledgements: The authors acknowledge financial support from Deutscher Akademischer Austauschdienst and from Fundação das Universidades Portuguesas under the protocol CRUP-DAAD (Ações Integradas Luso-Alemãs nºE-20/16, DAAD Zuwendungsvertrag 57212899).
The improvement of immunoanalytical methods for the determination of pharmaceuticals in wastewaters is a crucial yet challenging endeavor. In this work, the development of an automated miniaturized ELISA based on micro-Bead Injection Spectroscopy (μ-BIS) [1] for the determination of carbamazepine, a widely employed anti-epileptic drug and emergent pollutant [2], was pursued.
The experimental workflow comprised the offline functionalization of Sepharose beads with specific anti-CBZ antibodies via affinity immobilization using protein G, and 3 online steps inside the microfluidic analyzer lab-on-valve (LOV): I) packing of the bead column into the detection unit; II) sequential percolation of sample and a CBZ competitor- labeled with horseradish peroxidase (tracer) through the bead column; and III) on-column colorimetric detection employing the enzyme substrate 3,3’,5,5’-tetramethylbenzidine. After each analysis, the bead column was discarded, and the flow cell was washed before receiving new beads.
The elimination of manual washing steps is a novel feature compared to batch-wise ELISA, making the method less error-prone and therefore more robust. The replacement of the solid support prevents memory effects and cross-contamination between runs. The use of microparticles as solid support for the molecular recognition elements accounts for high area-to-volume ratios, and low molecular diffusion distances. For that reason, time-to-result was reduced from several hours to less than 10 min. The consumption of reagents was also very low. For instance, only ca. 200 μg of solid support and 900 ng of anti-CBZ antibody were required per determination. At last, the versatility of the LOV platform offers the possibility of adapting the assay to other relevant pharmaceuticals and anthropogenic markers in water.
Acknowledgements: Inês I. Ramos thanks FCT (Fundação para a Ciência e a Tecnologia) and POPH (Programa Operacional Potencial Humano) for her grant (SFRH/BD/97540/2013). This work received financial support from the European Union (FEDER funds POCI/01/0145/FEDER/007265) and National Funds (FCT/MEC - Ministério da Educação e Ciência) under the Partnership Agreement PT2020 UID/QUI/50006/2013. Financial support from Deutscher Akademischer Austauschdienst and from Fundação das Universidades Portuguesas under the protocol CRUP-DAAD (Ações Integradas Luso-Alemãs nºE-20/16) is also acknowledged.
[1] Gutzman, Y.; Carrol, A. D. Analyst 2006, 131, 809.
[2] Murray, K. E.; Thomas, S. M.; Bodour, A. A. Environ. Pollut. 2010, 158, 3462.
IAPR participates in the EMPIR 16SRT02, entitled ‘Certified forensic alcohol reference materials - ALCOREF’ funded by EURAMET as an external funded partner. The Research in this project will address the needs for better enforcement of drink-driving legislation in several European countries, by building up long-term capacities for the production and certification of forensic alcohol reference materials, suitable for the calibration of evidential breath alcohol analyzers. The certification procedure includes characterization of the materials, assessment of homogeneity, stability, and uncertainty estimation. An interlaboratory comparison will be conducted to test the materials and capabilities developed. EMPIR 16SRT02-ALCOREF project is coordinated by BAM (DE).
The impact of nanoparticles, NPs, at the single cell level has become a major field of toxicological research and different analytical methodologies are being investigated to obtain biological and toxicological information to better understand the mechanisms of cell–NP interactions. Here, inductively coupled plasma mass spectrometry in the single cell measurement mode (SC-ICP-MS) is proposed to study the uptake of silver NPs, AgNPs, with a diameter of 50 nm by human THP-1 monocytes in a proof-ofprinciple experiment. The main operating parameters of SC-ICP-MS have been optimized and applied for subsequent quantitative analysis of AgNPs to determine the number of particles in individual cells using AgNP suspensions for calibration. THP-1 cells were incubated with AgNP suspensions with concentrations of 0.1 and 1 µg/mL for 4 and 24 hours. The results reveal that the AgNP uptake by THP-1 monocytes is minimal at the lower dose of 0.1 µg/mL (roughly 1 AgNP per cell was determined), whereas a large cell-to-cell variance dependent on the exposure time is observed for a 10 times higher concentration (roughly 7 AgNPs per cell). The method was further applied to monitor the AgNP uptake by THP-1 cells differentiated macrophages incubated at the same AgNP concentration levels and exposure times demonstrating a much higher AgNP uptake (roughly from 9 to 45 AgNPs per cell) that was dependent on exposure concentration and remained constant over time. The results have been compared and validated by sample digestion followed by ICP-MS analysis as well as with other alternative promising techniques providing single cell analysis.
Carbamazepine (CBZ) and cetirizine (CTZ) are pharmaceutical drugs detected in the aquatic environment. However, the effects to marine invertebrates derived from the combination of these drugs with decreased pH conditions due to ocean acidification are poorly explored. This study investigated the biochemical parameters related to metabolic capacity and oxidative stress response and the transcription of genes related to the mode of action (MoA) of CBZ (1.0 μg/L) and CTZ (0.6 μg/L) in the clam Ruditapes philippinarum chronically exposed (28 days) to control (7.8) and low (7.5) pH conditions. The biochemical parameters applied were: the activity of electron transport system (indicator of organisms’ metabolic capacity); lipid peroxidation content (indicator of cell damage); total glutathione peroxidase activity (indicator of antioxidant defense). The transcription of genes related with drug neurotransmission and metabolism, cell defense and immunity and biomineralization was studied. No metabolic changes and oxidative stress was induced by the exposure to CBZ or CTZ at each pH level, but the transcription of several genes related with the MoA (neurotransmission, immunity and biomineralization) was altered by low pH, drug exposure and the combination of both stressors. In conclusion, it was shown that the interaction of drug exposure and low pH conditions can change bivalves’ sensitivity to drugs or alter drugs toxicity.
Diclofenac (DCF) is a widely used drug against fever, inflammation, pain, and rheumatic diseases. An average of 70 % of the ingested diclofenac is excreted in the urine. Thus, 63 tons per year are introduced into the water cycle in Germany. Due to insufficient removal of diclofenac in wastewater treatment plants, residues of diclofenac can be found in surface water and sometimes in drinking water. In order to establish an immunoassay, an anti-DCF antibody was required. Some antibody developments have been reported, based on an immunogen resulting from direct coupling of diclofenac to proteins via the carboxylic function. Finally, we used a monoclonal antibody, clone F01G21.
Highly selective and sensitive antibodies are only available for a limited number of small molecules. Hence the development of new antibodies is important to exploit the full potential of immunoanalytics. Small molecules do not elicit an immune response in mammals unless conjugated to carrier molecules. The choice of the structures to be conjugated, called haptens, is critical for the antibody production. Here we present our Approach to produce antibodies for the plasticizer diisononyl 1,2-cyclehexane-dicarboxylic acid (DINCH) and di-2-ethylhexyl terephthalate (DEHT) as well as the bile acid isolithocholic acid (ILA).
Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the sticky character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing an LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend an LC-MS/MS-based quantification method with a dynamic range of 0.5–40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials.
The comparison required the assignment of the mass fraction of folic acid present as the main component in the comparison sample. Performance in the comparison is representative of a laboratory's measurement capability for the purity assignment of organic compounds of medium structural complexity [molecular weight range 300–500] and high polarity (pKOW < −2).
Methods used by the eighteen participating NMIs or DIs were based on a mass balance (summation of impurities) or qNMR approach, or the combination of data obtained using both methods. The qNMR results tended to give slightly lower values for the content of folic acid, albeit with larger associated uncertainties, compared with the results obtained by mass balance procedures. Possible reasons for this divergence are discussed in the report, without reaching a definitive conclusion as to their origin.
The comparison demonstrates that for a structurally complex polar organic compound containing a high water content and presenting a number of additional analytical challenges, the assignment of the mass fraction content property value of the main component can reasonably be achieved with an associated relative standard uncertainty in the assigned value of 0.5%
Studies on the development of antibodies for the highly hydrophobic plasticizers DINCH and DEHT
(2018)
Diisononylcyclohexane-1,2-dicarboxylate (DINCH) and di-2-ethylhexyl terephthalate (DEHT), two of the most important substitutes for phthalate plasticizers, are used for a wide range of applications. Consequently, an increasing occurrence in urine and environmental samples is reported. Reliable and fast analytical methods for the quantification of these plasticizers are needed. So far, mainly GC-MS or LC-MS methods are used. We aimed to develop the first antibodies and immunoassays allowing for high-throughput analysis of samples. We designed two DINCH hapten structures and one DEHT hapten structure and employed hapten-protein conjugates for the immunization of rabbits. Sensitive competitive enzyme-linked immunosorbent assays (ELISAs) against each hapten using the produced polyclonal antibodies were established. Yet, binding of DINCH to the respective antibodies was not observed in neither direct nor indirect assay formats, even when using protein conjugates with the heterologous haptens and different carrier proteins in the indirect format. The use of surfactants and solvents in the sample buffer did not result in recognition of the plasticizers. Also, no binding of DEHT in ELISA employing the respective antibodies was detected. We speculate that the production of antibodies against these highly hydrophobic molecules is not possible via our route, however a different hapten design could overcome this obstacle.
The aim of this study was to identify specific chemical bonds and characteristic structures in melanoidins formed from D-glucose and L-alanine between 130 and 200 °C. The results might be used to control the type and amount of melanoidin produced during food processing. For this purpose, complementary techniques, such as FTIR, NMR, EPR, and MALDI-ToF, were employed. At 160 °C color, solubility and UV/Vis absorption change characteristically and consequently, structural transformations could be observed in FTIR and NMR spectra. For example, sharp signals of N-H, C-N, and C-H oscillations in the L-alanine spectrum are prone to inhomogeneous broadening in melanoidins prepared above 150 °C. These changes are caused due to formation of heterogeneous macromolecular structures and occur during condensation reactions that lead to an increasing loss of water from the melanoidins with increasing temperatures. Additionally, MALDI-ToF-MS indicates the polymerization of glyoxal/glyoxylic acid and EPR shows the formation of radical structures.
In this work we report a novel paper-based analytical device read-out via LED-induced fluorescence detection (FPAD) for the quantification of the emerging pollutant ethinylestradiol (EE2) in river water samples. The PAD was used as a reaction platform for a competitive enzyme immunoassay. For the PAD development, microzones of filter paper, printed by a wax printing method, were modified with amino-functionalized SBA-15 and subsequently, anti-EE2 specific antibodies were covalently immobilized. The determination of EE2 in water was
carried out by adding a fixed concentration of EE2 conjugated with the enzyme horseradish peroxidase (HRP) to samples and standards. Then, the FPAD were added and incubated for 10 min. Finally, the detection was performed by the reaction of 10-acetyl-3,7-dihydroxyphenoxazine (ADHP) whose oxidation is catalyzed by HRP in the presence of H2O2, obtaining the highly fluorescent resorufin (R). Resorufin was detected by LED excitation at 550 nm, observing emission at 585 nm. The EE2 concentration in the samples was inversely proportional to the relative fluorescence obtained from the enzymatic reaction products. The FPAD assay showed a detection Limit (LOD) of 0.05 ng L−1 and coefficients of variation (CV) below 4.5% within-assay and below 6.5% between-assay, respectively. The results obtained show the potential suitability of our FPAD for the selective and sensitive quantification of EE2 in river water samples. In addition, it has the PADs advantages of being disposable, easy to
apply and inexpensive.
The talk introduces the technique of LC-ELISA: fractionating pre-concentrated water samples, analyzing them for containing compounds that bind to hapten-selective antibodies followed by high-Resolution mass spectrometry non-target analysis of "positive" fractions for Transformation products of emerging organic contaminants.
Hepcidin-25 has attracted much attention ever since its discovery in 2001. It is widely recognized that this peptide hormone plays a major role in the regulation of iron levels in mammals and can reveal important clinical information about several iron-related disorders. However, the development of a reliable assay to quantify hepcidin proved to be problematic and serum hepcidin-25 concentrations determined by various assays differ substantially. Challenges arise in the MS analysis of hepcidin due to the “sticky” character of the peptide and the lack of suitable standards.
With the aim to tackle the current difficulties in hepcidin quantification and improve the status of this promising biomarker in the clinical field, we developed a rapid and robust analytical strategy for the quantification of hepcidin-25 in human samples based on HPLC-MS/MS (QqQ) as a reference method candidate to be implemented in routine laboratories. The novelty of the method is the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces. Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions where the use of acidic mobile phases was compared with a novel approach involving solvents at high pH containing 0.1% of ammonia. Both methods were carefully validated and applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with very good correlation of the results.
We report a novel and innovative electrochemical paper-based immunocapture assay (EPIA) to address the need for ultrasensitive detection of emerging pollutants without regulatory status and whose effects on environment and human health are not completely yet understood. In particular, we present the application of this system toward highly sensitive detection of the emerging pollutant ethinyl estradiol (EE2). The EPIA approach is based on the use of paper microzones modified with silica nanoparticles (SNs) and anti-EE2 specific antibodies for capture and preconcentration of EE2 from river water samples. After the preconcentration procedure, the paper microzones are placed onto a screen-printed carbon electrode modified with electrochemically reduced graphene (RG). The bound EE2 is subsequently desorbed adding a diluted solution of sulfuric acid on the paper microzones. Finally, recovered EE2 is electrochemically detected by OSWV. The proposed novel methodology showed an appropriate LOD and linear range for the quantification of EE2 for water samples with different origins. The nonsophisticated equipment required, the adequate recovery values obtained (from 97% to 104%, with a RSD less than 4.9%), and the appropriate LOD and linear range value (0.1 ng L−1 and 0.5−120 ng L−1, respectively) achieved by our immunocapture sensor present significant analytical figures of merit, particularly when the routine quantification of EE2 is considered. In addition, our System was based on electrochemical paper-based technology, which allows obtainment of portable, easy-to-use, inexpensive, and disposable devices. The EPIA can also serve as a general-purpose immunoassay platform applicable to quantitation of other drugs and emerging pollutants in environmental samples.
A vast number of emerging pollutants has been detected in the environment over the last decades. Analytical methods suitable for trace analysis are needed that are desirably also fast, inexpensive and, if possible, robust and portable. Immunoanalytical methods which are available in a broad range of formats, can be profitably used here to analyze for the distribution and the trends of concentration levels of contaminants in the environment. Some of these formats are single-analyte but high-throughput methods. In order to use them wisely, indicator substances, sometimes called anthropogenic markers, should be selected and used in screening approaches. Other methods are suitable to be performed on portable instrumentation in the field (on-site) or in facilities such as wastewater treatment plants for on-line monitoring. Furthermore, there are the socalled array technologies that allow for parallel analysis of several analytes of interest (multiplexing). The microtiter-plate based ELISA (Enzyme-linked Immunosorbent Assay) is the method of choice for the analysis of a large number of samples [1]. ELISA screening data for anthropogenic markers such as the antiepileptic carbamazepine, the analgesic diclofenac, the anti-histaminic cetirizine, the steroid hormone estrone, the antimicrobial sulfamethoxazole, the stimulants caffeine and cocaine, the priority pollutant bisphenol A, and the bile acid isolithocholic acid [2] are presented. For on-site screening and monitoring, simpler formats, like mix-and-read assays, e.g. the Fluorescence Polarization Immunoassay (FPIA) or Lateral-flow Immunoassays (LFIA) are more suitable tools. Electrochemical formats run on portable devices provide additional advantages as no light source is required. Some examples are presented and discussed. The suitability of multi-analyte formats such as immunomicroarrays depends on the choice of a signal-producing system that provides small uncertainties and good reproducibility of the measurements. Biochip (“flat”) arrays read out on slide scanners and bead-based (“suspension”) arrays read out in flow cytometers are two options and show their distinct pros and cons. Altogether these approaches show the great potential immunoanalytical methods provide for the screening for environmental contaminants in the aquatic environment.
The antimicrobial photodynamic approach has been demonstrated as an efficient and sustainable process for the eradication of microbial pathogens. In this work, silica-coated Magnetite nanoparticles (NPs) were used as carriers of glycosylated porphyrins and phthalocyanines. Their subsequent cationization
resulted in the production of stable antimicrobial photosensitizing materials, effective against E. coli. Suspensions of the photocatalysts in water present bimodal size distributions formed by big clusters and small NPs with hydrodynamic diameters between 8 and 38 nm. The presence of small NPs in the suspensions is related to an effective photodynamic inactivation (PDI) of E. coli cells. Glycosylation of the PS showed a positive effect on the PDI performance, which could be related to a higher accumulation of the photocatalyst over the bacterial cell membrane. In addition, these biocidal agents proved to be photostable and their photoactive performance decreased only between 23% and 28% upon 5 PDI cycles, mostly because of the loss of material between cycles, which makes them promising materials for water disinfection purposes.
Microfluidic electrochemical immunosensor for the trace analysis of cocaine in water and body fluids
(2018)
Quick but accurate testing and on‐the‐spot monitoring of cocaine in oral fluids and urine continues to be an important toxicological issue. In terms of drug testing, a number of devices have been introduced into the market in recent decades, notably for workplace inspection or roadside testing. However, these systems do not always fulfill the requirements in terms of reliability, especially when low cut‐off levels are required. With respect to surface water, the presence of anthropogenic small organic molecules such as prescription and over‐the‐counter pharmaceuticals as well as illicit drugs like cannabinoids, heroin, or cocaine, has become a challenge for scientists to develop new analytical tools for screening and on‐site analysis because many of them serve as markers for anthropogenic input and consumer behavior. Here, a modular approach for the detection of cocaine is presented, integrating an electrochemical enzyme‐linked immunosorbent assay (ELISA) performed on antibody‐grafted magnetic beads in a hybrid microfluidic sensor utilizing flexible tubing, static chip and screen‐printed electrode (SPE) elements for incubation, recognition, and cyclic voltammetry measurements. A linear response of the sensor vs. the logarithm of cocaine concentration was obtained with a limit of detection of 0.15 ng/L. Within an overall assay time of 25 minutes, concentrations down to 1 ng/L could be reliably determined in water, oral fluids, and urine, the system possessing a dynamic working range up to 1 mg/L.
For years there have been more and more reports on the presence of drugs in the aquatic environment. Due to the demographic change, the consumption of pharmaceuticals has risen sharply. After taking the drugs, they are partly metabolized in the human body. However, the metabolism is not complete so that both the metabolites and non-metabolized amounts of the parent compounds are excreted. These compounds reach the waste water and afterwards the sewage treatment plants. In sewage treatment plants transformation products can be formed by the oxidative conditions during wastewater treatment processes. The transformation products may have a higher toxicity than the actual environmental pollutants and are often only partly removed during the waste water treatment. Since a lot of these compounds are still unknown, the transformation products are not detected by target analysis used in sewage treatment plants and are often released undetected in the aquatic ecosystems. The released substances may be subject to additional transformation processes in the environment. Pharmaceuticals produced in high amounts can be already detected in the μg/L range in water bodies worldwide.
Metformin and its major transformation product guanylurea are one of the main representatives. Metformin is the drug of choice for treating type 2 diabetes. The drug therapy for diabetes mellitus has increased significantly in recent years. In the year 2015 1500 tons of metformin were prescribed in Germany (for statutory insured persons). Metformin is not metabolized in the human body and is excreted unchanged therefore concentrations between 57 μg/L and 129 μg/L are found in German waste water treatment plants influents.
In this work the transformation of the antidiabetic drug metformin is investigated. The degradation of metformin is initialize by commercial water treatment techniques like UV-radiation or noncommercial techniques like heterogenous photocatalysis based on titanium dioxide. The degradation of metformin and resulting transformation products are analyzed by LC-MS/MS and LC-HRMS.
Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umweltbeständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz, die jeweils mit polybromierten Flammschutzmitteln (PBFSM) versehen sind. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Auch soll mit Hilfe der RFA und der LA-ICP-MS die Abreicherung der PBFSM in den Modellmaterialien beschrieben werden. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden.
ALCOREF is a project within the European Metrology Programme for Innovation and Research (EMPIR. It is part of the 2016 EMPIR Research Potential Call dedicated to build up metrological and research capacity in less developed National Metrology Institutes (NMIs).
The project will develop long term expertise for the production and certification of ethanol/water reference materials in the participating NMIs. Materials to be developed will be suitable for the calibration and approval of evidential breath alcohol analysers as defined by recommendation R 126 of the International Organization of Legal Metrology (OIML). Certification includes the characterisation of the materials, assessment of homogeneity, stability and uncertainty. Target certified values and volumes will address end-users’ needs regarding regional legal limits for alcohol in traffic and the instrumentation for breath analyser calibration available in different countries. Thus, the project supports the law enforcement of national drink-driving legislation.
The consortium comprises of 11 institutions from 10 European countries. Project participants will establish reliable analytical methods for the purity assessment of ethanol, such as Karl-Fischer titration, to achieve traceability of their certified values. Chromatographic or density methods for the quantification of ethanol in water will also be established, validated and applied for homogeneity and stability assessment. An interlaboratory comparison will be conducted within the European Association of National Metrology Institutes’ (EURAMET) Technical Committee Metrology in Chemistry to test the equivalence of the new certified reference materials and the analytical methods implemented.
The poster will present the outline and first results of the ALCOREF project.
Microfluidic electrochemical immunosensor for the trace analysis of cocaine in water and body fluids
(2018)
Quick but accurate testing and on‐the‐spot monitoring of cocaine in oral fluids and urine continues to be an important toxicological issue. In terms of drug testing, a number of devices have been introduced into the market in recent decades, notably for workplace inspection or roadside testing. However, these systems do not always fulfill the requirements in terms of reliability, especially when low cut‐off levels are required. With respect to surface water, the presence of anthropogenic small organic molecules such as prescription and over‐the‐counter pharmaceuticals as well as illicit drugs like cannabinoids, heroin, or cocaine, has become a challenge for scientists to develop new analytical tools for screening and on‐site analysis because many of them serve as markers for anthropogenic input and consumer behavior. Here, a modular approach for the detection of cocaine is presented, integrating an electrochemical enzyme‐linked immunosorbent assay (ELISA) performed on antibody‐grafted magnetic beads in a hybrid microfluidic sensor utilizing flexible tubing, static chip and screen‐printed electrode (SPE) elements for incubation, recognition, and cyclic voltammetry measurements. A linear response of the sensor vs. the logarithm of cocaine concentration was obtained with a limit of detection of 0.15 ng/L. Within an overall assay time of 25 minutes, concentrations down to 1 ng/L could be reliably determined in water, oral fluids, and urine, the system possessing a dynamic working range up to 1 mg/L.
The development of quick and simple optical sensing technologies for Endocrine Disrupting Chemicals (EDCs) is needed to facilitate monitoring of these substances to ensure consumer safety. Optical sensing was achieved against phthalates acting as EDC that have host guest interaction with an intercalated Metal-organic framework (MOF), resulting in a fluorescence emission upon excitation. The fluorescent turn-on signal was generated by using a fluorophore with a structural component that has little fluorescence unless excimers are formed. Strategies to engineer functional MOF structures suitable for sensing EDC phthalates were developed, and the characterization of the MOFs with and without present phthalates was done by single crystal XRD, PXRD, RAMAN and Thermogravimetry. Extensive photo-physical characterization of host-guest complexes of different phthalates and the MOF as well as the resulting exciplex fluorescence was performed. Photo physical characterization revealed an analyte specific fluorescence fingerprint that allows discerning even minute changes in chemical structures of the analyte and therefore paving the way for sensing tools in real world analytical applications. The presented capability of MOFs to sense EDCs is envisioned to complement established methods from analytical chemistry such as mass spectrometry based methods which can’t be used on site and are often associated with infrastructural capacity constraints
Diclofenac (DCF) is a non-steroidal anti-inflammatory drug (NSAID) with analgetic, anti-inflammatory, and antipyretic properties. The mechanism of action of diclofenac, like that of other NSAIDs, involves inhibition of cyclooxygenase (COX-1 and COX-2). Another pharmacological effect is preventing of prostaglandin synthesis in vitro. Prostaglandins are mediators of inflammation, because diclofenac is an inhibitor of prostaglandin synthesis.
A method has been developed to analyse for diclofenac (DCF) in the milk.
The development of fast and cheap highthroughput platforms for the detection of environmental contaminants is of particular importance to understand the human-related impact on the environment. The application of DNA-directed immobilization (DDI) of IgG molecules is
currently limited to the clinical diagnostics scenario, possibly because of the high costs of production of such addressable platforms. We here describe the efficient and specific hybridization of an antibody−oligonucleotide conjugate to a short 12-mer capture probe. The specific antibody used is a monoclonal antibody against caffeine, a stimulant and important anthropogenic marker. With this work, we hope to contribute to broadening the application potential of DDI to environmental markers in order to develop cheaper and more stable high-throughput screening platforms for standard Routine analysis of pollutants in a variety of complex matrices.
Hepcidin-25 was identified as the main iron regulator in the human body, and it by binds to the sole iron-exporter ferroportin. Studies showed that the N-terminus of hepcidin is responsible for this interaction, the same N-terminus that encompasses a small copper(II)-binding site known as the ATCUN (amino-terminal Cu(II)- and Ni(II)-binding) motif. Interestingly, this copper-binding property is largely ignored in most papers dealing with hepcidin-25. In this context, detailed investigations of the complex formed between hepcidin-25 and copper could reveal insight into its biological role. The present work focuses on metal-bound hepcidin-25 that can be considered the biologically active form. The first part is devoted to the reversed-phase chromatographic separation of copper-bound and copper-free hepcidin-25 achieved by applying basic mobile phases containing 0.1% ammonia. Further, mass spectrometry (tandem mass spectrometry (MS/MS), high-resolution mass spectrometry HRMS)) and nuclear magnetic resonance (NMR) spectroscopy were employed to characterize the copper-peptide. Lastly, a three-dimensional (3D)model of hepcidin-25with bound copper(II) is presented. The identification of metal complexes and potential isoforms and isomers, from which the latter usually are left undetected by mass spectrometry, led to the conclusion that complementary analytical methods are needed to characterize a peptide calibrant or reference material comprehensively. Quantitative nuclear magnetic resonance (qNMR), inductively-coupled plasma mass spectrometry (ICP-MS), ion-mobility spectrometry (IMS) and chiral amino acid analysis (AAA) should be considered among others.
Estrone (E1), a metabolite of the estrogenic hormones 17β-estradiol (β-E2) and 17α-estradiol (α-E2), is itself a potent estrogen which can have a significant impact on the hormonal balance. Due to ist high potential for adverse effects on human health and aquatic life even at pg/L to ng/L levels, its appearance in water should be monitored. E1 has also been considered a marker substance for the presence of other estrogens. This study presents a newly developed direct competitive enzymelinked immunosorbent assay (ELISA) for quantification of E1 in environmental water samples using new monoclonal antibodies.
The quantification range of the ELISA is 0.15 μg/L to 8.7 μg/L E1, and the limit of detection is around 60 ng/L for not pre-concentrated water samples. A pre-concentration step after careful selection of suitable phases for SPE was developed, too. The influence of organic solvents and natural organic matter on the ELISA was assessed. The high selectivity of the monoclonal antibody was demonstrated by determining the cross-reactivity against 20 structurally related compounds.
For the assessment of matrix effects, a concept (“LC–ELISA”) is thoroughly exploited, i.e., separating complex samples by HPLC into 0.3 min fractions and determination of the apparent E1 concentration. Furthermore, fractions with interferences for nontarget/suspected-target analysis can be assigned. A dilution approach was applied to distinguish between specific interferences (cross-reactants) and non-specific interferences (matrix effects). In the determination of 18 environmental samples, a good agreement of the E1 concentration in the respective fractions was obtained with mean recoveries of 103 % to 132 % comparing ELISA to LC–MS/MS.
Singlet oxygen generation potential of two novel free-base-porphyrin photocatalysts was investigated. The freebase-porphyrin-sensitized Fe3O4 magnetic nanoparticles (MNPs) were tested for the degradation of the model pollutant Bisphenol A (BPA) in aqueous solution, for the first time. MNPs with either cubic or spherical shape were synthesized using the sonochemical approach, followed by sensitizing with photoactive 4,4′,4′′,4′′′- (Porphine-5,10,15,20-tetrayl)tetrakis(benzoic acid) (TCPP). The resulted photocatalysts were characterized in detail by scanning and transmission electron microscopy, Brunauer–Emmett–Teller analysis, spectral techniques and vibrating sample magnetometry. The electron spin resonance experiments have confirmed the high activity of the photocatalysts through the efficient formation of singlet oxygen in solution. The optimum operational parameters for BPA degradation were established as follows: 1.0 μmol L−1 BPA, 1.0 g L−1 of photocatalyst, 100 μmol L−1 H2O2, under UVA irradiation. In these conditions, the results for both photocatalysts revealed that after only 10 min of reaction, over 64% and ca. 90% of BPA have been removed from solution in the absence and presence of H2O2, respectively. Whereas after 60 minutes of treatment, only 24% of BPA in real wastewater effluent samples were removed under UVA irradiation in the absence of H2O2, showing the high complexity of real wastewater. Moreover, both photocatalysts were successfully used for BPA removal in three consecutive runs, without significant loss of catalytic features.
Cost-effective water cleaning approaches using improved Treatment technologies, for instance based on catalytic processes with high activity catalysts, are urgently needed. The aim of our study was to synthesize efficient Fenton-like photo-catalysts for rapid degradation of persistent organic micropollutants in aqueous medium. Iron-based nanomaterials were chemically synthesized through simple procedures by immobilization of either iron(II) oxalate (FeO) or iron(III) citrate (FeC) on magnetite (M) nanoparticles stabilized with polyethylene glycol (PEG). Various investigation techniques were performed in order to characterize the freshly prepared catalysts. By applying advanced oxidation processes, the effect of catalyst dosage, hydrogen peroxide concentration and UV-A light exposure were examined for Bisphenol A (BPA) conversion, at laboratory scale, in mild conditions. The obtained results revealed that BPA degradation was rapidly enhanced in the presence of low-concentration H2O2, as well as under UV-A light, and is highly dependent on the surface characteristics of the catalyst. Complete photo-degradation of BPA was achieved over the M/PEG/FeO catalyst in less than 15 minutes. Based on the catalytic performance, a hierarchy of the tested catalysts was established: M/PEG/FeO > M/PEG/FeC > M/PEG. The results of cytotoxicity assay using MCF-7 cells indicated that the aqueous samples after treatment are less cytotoxic.
Analytical Sciences has developed from Ostwald’s “unentbehrlichen Dienstmagd” to a chemical discipline at the core of many of today’s fundamental and applied scientific problems and innovations. An atomic or molecular understanding of basic processes in chemistry, soft matter physics, materials and life science is enabled only through new analytical methods and instrumentation. Similar observations can be found for pressing sociopolitical conflicts of the future: A rational discussion of global climate change or new energy sources is only possible with reliable analytical results. Progress in Analytical Sciences is only possible if the underlying interdisciplinary character is acknowledged and valued. The talk will illustrate the scope of modern Analytical Science through examples from process analysis relevant to modern process intensification and industry 4.0 to bioanalysis and the use of synchrotron radiation to elucidate fundamental reactions materials.
Raw data from metabolomics experiments are initially subjected to peak identification and signal deconvolution to generate raw data matrices m × n, where m are samples and n are metabolites. We describe here simple statistical procedures on such multivariate data matrices, all provided as functions in the programming environment R, useful to normalize data, detect biomarkers, and perform sample classification.
Environmental sustainability and –stability of Materials concerning the Migration of pollutants
(2018)
MaUS is an acronym for ”Material und Umweltsimulationen“. Plastics are in the focus of environmental politics due to their long-term behaviour and therefore to their persistence. Not only that they appear as visible contaminants in the sea and on the beach, but their unknown behaviour concerning their additives as well as the related transformation products are anxious. Therefore, we wish to establish a certified reference method to provide a method for testing plastics.
Aim of this project is the development of fast motion standard reference methods for testing plastics regarding to their environmental compatibility. To establish these testing methods, we use polystyrene (PS) and polypropylene (PP) with environmental relevant brominated flame retardants, known for their persistent bioaccumulative and toxic (PBT) properties. In case of PS the material contains 1 wt% of 1,2,5,6,9,10-hexabromocyclododecan (HBCD) and in case of PP 0.1 wt% bromodiphenylether (BDE-209), which is known as a substance of very high concern (SVHC). Furthermore, we use polycarbonate (PC), which is still used as material in baby flasks and releases Bisphenol A (BPA), an estrogenic active substance.
As an additional material PTFE is used for its importance as a source for two ubiquitous environmental substances (PFOS and PFOA), whose toxicological effects are still incompletely known.
The focus in this current work is set on the transfer of potential pollutants out of applied materials mentioned above into environmental compartments like water or soil. Here an accelerated aging concept should be developed to shortened time consuming natural processes. For these resulting simulations we use a programmable weathering chamber with dry and wet periods and with high and low temperatures. These programmes run for several weeks and according to a defined sampling schedule we take water samples, run a clean-up procedure by SPE (Molecular imprinted polymers (MiPs) resp. polymer-based cartridges (Waters Oasis HLB)) and analyse them by HPLC-UV resp. LC-MS/MS. Of most interest in case of flame retardants are photocatalytic transformation products. Therefore, we conduct a non-target-screening resp. a suspected target-screening by LC-MS/MS and HRMS.
Gegenstand des Projekts ist die Prüfung der Umweltbeständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polycarbonat, Polytetrafluorethylen, Polystyrol und Polypropylen zum Einsatz. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden, die es gestatten, Schnellprüfverfahren zu etablieren, die die Simulation der realen Beanspruchungen im Zeitraffermodell anwendbar machen. Somit sollen standardisierbare Schnellbeanspruchungs-verfahren erarbeitet werden, die als Prüfeinrichtungen etabliert werden und von externen Auftraggebern zur Prüfung der Umweltbeständigkeit und -verträglichkeit von neuen Materialien genutzt werden können. Die Umweltwirkungen (chemisch-physikalisch und mikrobiologisch) sollen so definiert eingesetzt werden, dass eine reproduzierbare Prüfung möglich wird. Aus diesen Verfahren und Methoden sollen Normen abgeleitet werden, die eine standardisierte Materialprüfung ermöglichen.
In addition to previously reported results on the simulated aging of polystyrene samples (PS) containing 1 wt. % hexabromocyclododecane (HBCD), we present the first results of our investigations of polypropylene (PP)-samples containing 0.1 wt. % BDE-209. All studied polymer samples were exposed to a defined weathering schedule in a climate chamber in accordance to regulation EN ISO 4892-3:2006.For the determination of BDE-209 in the collected rain water samples derived from the used climate chamber, the samples were prepared in accordance with a validated protocol. Before the analyses, each sample was spiked with 2 µL of isotopically labeled BDE-209 (13C10-BDE-209) to serve as internal standard (ISTD) in the performed stable isotope dilution analysis. Subsequently the samples were extracted with isooctane, the obtained aliquots of the extracts were concentrated to 200 µL and 2 µL of the resulting solution were injected to the GC/MS for quantification.
Additionally, the total bromine contents are monitored for the aged and untreated samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) as well as X-ray fluorescence analysis (XRF) as non-destructive and rapid method. Furthermore, results from surface analysis using environmental scanning electron microscopy (ESEM) for morphological characterization of the aged and untreated samples were presented and discussed. In general, the resulting data from the accelerated aging will be compared to those from the natural weathering experiments (“atmospheric exposure”, in soil).
The atmospheric exposure was performed by placing the samples on a weathering rack, which is aligned in SW direction (in a 45° angle to the horizon). The weathering data were regularly recorded by Deutscher Wetterdienst at this site. The surfaces of the test specimens (aged and stored references) were analyzed by ESEM as well as by LA-ICP-MS and by XRF. The surface of PS and PP specimens aged outdoors present the aging under real conditions and allow the comparison to the accelerated aged specimens by means of the weathering chamber. This way, we explore the efficiency of the accelerated aging procedure, which provides the advantage of well-defined and reproducible conditions compared to natural weathering, as a tool for testing different plastic materials.
Additionally “in soil” experiments were conducted in-door in a well characterized testing soil. The soil (boulder-clay, sand with 12 % loam, particle size in total 0.2-4 mm) is filled in a free-draining concrete basin inside of an air-conditioned room. In this manner, TOC, water capacity and humidity are recorded parameters. To assure a washing out process from the samples by the raining water, the target water content is calculated to 8%. The actual humidity is measured by a tensiometer, assuring the duration of the raining period. The water content is additionally monitored by weight of the basin, capturing water from raining periods. The correct humidity is a fundamental parameter for biological activity. Samples of PS resp. PP were of dimension 10x1cm and 5 specimens were placed up to the half in the soil per basin. Microbial activity of the soil, monitored by the reference polyurethane, sets HBCD resp. BDE-209 of the samples free and will be leached from the samples by raining water. Thereafter these will be captured by passive samplers placed in a distinct distance to the samples in the soil. The “in soil” experiments are complementary to the weathering experiments due to the biological activity in the soil. These experiments simulate the fate of the brominated flame retardants in the biosphere.
Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umwelt-beständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden.
Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umweltbeständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz, die jeweils mit polybromierten Flammschutzmitteln (PBFSM) versehen sind. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Auch soll mit Hilfe der RFA und der LA-ICP-MS die Abreicherung der PBFSM in den Modellmaterialien beschrieben werden. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden.
Draft standards for the determination of organic pollutants in the solid matter of environmental matrices such as sludge, treated biowaste and soil have been basically developed in the framework of the European standardization project HORIZONTAL. A research project financed by the German Federal Environment Agency was initiated to finalize some of these CEN standard drafts, since fully validated standard procedures are crucial for the evaluation of their reliability in the context of implementation in legislation on environmental health.
Approach: Appropriate test materials (< 2mm particle size) were prepared and homogenized from contaminated soils, sludge and treated biowaste containing polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), dioxins, furans and dioxin-like-PCB and served, along with reference solutions, as the basis for international interlaboratory comparisons. Performance data of three analytical standard procedures were obtained by the statistical evaluation of results received from 11 to 29 participants per test material.
Results: The overall variation coefficients of reproducibility (between-lab standard deviations) for the sum parameters were roughly between 10 and 35 %. The variation coefficients of repeatability (within-lab standard deviations) range between 3 % and 8 % and show no trend considering the substance groups or matrices.
The highest coefficients of reproducibility were found for the analysis of PAHs, which were between 26 and 35 %, depending on the matrix, whereas 7-17 % reproducibility was observed for toxicity equivalents (TEQ) comprising dioxins, furans and dl-PCB.
Conclusions: Overall, the results confirm that the procedures described in the Technical Specifications are fit for purpose for all three matrices and that the feasibility of the HORIZONTAL approach, to cover several matrices with one standard per analyte, was thereby proven.
High-resolution mass spectrometry, either combined with gas or liquid chromatography (GC/LC-HR-MS), is currently the most powerful analytical option for broad nontargeted small molecule analysis. To transform HR-MS raw data from metabolomics or environmental studies into chemically meaningful data, several computational steps are needed, including peak detection, deconvolution of these peaks into compounds and putative identification of compounds using databases. Each of these steps can cause problems and still requires methodological advancements. Computational compound annotation as one of the steps, however, has proven particularly challenging, mainly due to the chemical diversity of organic analytes. In addition, different annotation approaches are needed for the different platforms used in HR-MS screening. We recently introduced InterpretMSSpectrum as an annotation workflow for GC-HR-MS using atmospheric pressure chemical ionization (APCI). InterpretMSSpectrum locates molecular ion, fragment and adduct peaks, calculates their most likely sum formula combination and graphically summarizes results as an annotated mass spectrum. As a complementary approach for LC-HR-MS, we presented findMAIN, which scores MS1 spectra based on explained intensity, mass accuracy and isotope charge agreement of adducts and related electrospray ionization (ESI) products to determine the neutral mass of unknown compounds. Both approaches were validated against large spectral libraries containing more than 600 compounds, for which correct annotation was achieved in over 80% of the cases. Based on the experiences from this validation, we here compare soft-ionization GC/LC-HR-MS regarding “annotatability” of unknown compounds from a computational perspective. As a main advantage for GC-HR-MS, the relatively uniform ionization behavior of commonly used trimethylsilyl (TMS) derivatives observed under APCI allowed differentiation of molecular ion peaks from in-source fragments based on relatively compact set of rules. By contrast, neutral mass inference in ESI required a more complex evaluation scheme, due to the higher diversity of ionization products observable in ESI. We demonstrate such differences by practical examples of both software packages applied to metabolomics studies and discuss the challenges connected to transferring the approaches to environmental screening.
Pharmaceuticals, certain food ingredients, and mammalian endogenous metabolic products in wastewater are mostly of human origin. They are anthropogenic markers.
Proper knowledge of their levels in wastewater helps to track sources of pollutants in natural waters and allows for calculation of removal efficiencies in wastewater Treatment plants. Here, we describe the development and application of an indirect competitive, multiplexing suspension Array fluorescence immunoassay (SAFIA) for the detection of carbamazepine (CBZ), diclofenac (DCF), caffeine (CAF), and isolithocholic acid (ILA) in wastewater, covering those classes of anthropogenic markers. The assay consists of haptens covalently conjugated to fluorescence-encoded polystyrene core/silica shell microparticles to create a site for competitive binding of the antibodies (Abs). Bound Abs are then stained with fluorophore-labeled Abs. Encoding and signaling fluorescence of the particles are determined by an automated flow cytometer.
For compatibility of the immunoassay with the 96-well microtiter plate format, a stop reagent, containing formaldehyde, is used. This enables a wash-free procedure while decreasing time-to-result. Detection limits of 140 ± 40 ng/L for CBZ, 180 ± 110 ng/L for CAF, 4 ± 3 ng/L for DCF, and 310 ± 70 ng/L for ILA are achieved, which meet the sensitivity criteria of wastewater analysis. We demonstrate the applicability of SAFIA to real wastewater samples from three different wastewater Treatment plants, finding the results in good agreement with LC-MS/MS. Moreover, the accuracy in general exceeded that from classical ELISAs. We therefore propose SAFIA as a quick and reliable approach for wastewater analysis meeting the requirements for process analytical technology.
We present the optical sensing of phthalate Esters (PAEs), a group of endocrine-disrupting chemicals. The sensing takes place as changes in the fluorescence emission intensity of aminopyrene covalently bound to the organic ligands of the metal−organic framework compound ZIF-8. In the presence of PAEs, a quenching of the fluorescence emission is observed. We evaluated strategies to engineer colloidal size distribution of the sensing particles to optimize the sensory response to PAEs. A thorough characterization of the modified ZIF-8 nanoparticles included powder X-ray diffractometry, transmission electron microscopy, high-performance liquid chromatography, and photophysical characterization. The presented capability of the fluorophore-functionalized ZIF-8 to sense PAEs complements established methods such as chromatography-based procedures, which cannot be used on-site and paves the way for future developments such as hand-held quick sensing devices.
We applied high resolution laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS) with cellular spatial resolution for bioimaging of nanoparticles uptaken by fibroblast multicellular spheroids (MCS). This was used to quantitatively investigate interactions of silver nanoparticles (Ag NPs) and the distributions of intrinsic minerals and biologically relevant elements within thin sections of a fibroblast MCS as a three-dimensional in vitro tissue model. We designed matrix-matched calibration standards for this purpose and printed them using a noncontact piezo-driven array spotter with a Ag NP suspension and multielement standards. The limits of detection for Ag, Mg, P, K, Mn, Fe, Co, Cu, and Zn were at the femtogram (fg) level, which is sufficient to investigate intrinsic minerals in thin MCS sections (20 μm thick). After incubation for 48 h, Ag NPs were enriched in the outer rim of the MCS but not detected in the core. The localization of Ag NPs was inhomogeneous in the outer rim, and they were colocalized with a single-cell-like structure visualized by Fe distribution (pixel size of elemental images: 5 × 0.5 μm). The quantitative value for the total mass of Ag NPs in a thin section by the present method agreed with that obtained by ICP-sector field (SF)-MS with a liquid mode after acid digestion.
We investigated the penetration of silver nanoparticles (Ag NPs) into a three-dimensional in vitro tissue analog using NPs with various sizes and surface coatings, and with different incubation times. A high-Resolution laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) time-of-flight (TOF) instrument was applied for imaging the distributions of elements in thin sample sections (20 μm thick). A fibroblast multicellular spheroid (MCS) was selected as the model system and cultured for more than 8 days to produce a natural barrier formed by the extracellular matrix containing collagen. The MCS was then exposed for up to 48 h to one of four types of Ag NPs (∅ 5 nm citrate coated, ∅ 20 nm citrate coated, ∅ 20 nm polyvinylpyrrolidone coated, and ∅ 50 nm citrate coated). Imaging showed that the penetration pathway was strongly related to steric networks formed by collagen fibrils, and Ag NPs with a hydrodynamic diameter of more than 41 nm were completely trapped in an outer rim of the MCSs even after incubation for 48 h. In addition, we examined the impact of these NPs on essential elements (P, Fe, Cu, and Zn) in
areas of Ag NP accumulation. We observed a linear increase at the sub-femtogram level in the total concentration of Cu (fg per pixel) in samples treated with small or large Ag NPs (∅ 5 nm or ∅ 50 nm) for 48 h.
Ideen nah am Leben
(2019)
The development of an automated miniaturized analytical system that allows for the rapid monitoring of carbamazepine (CBZ) levels in serum and wastewater is proposed. Molecular recognition of CBZ was achieved through its selective interaction with microbeads carrying anti-CBZ antibodies. The proposed method combines the advantages of the micro-bead injection spectroscopy and of the flow-based platform lab-on-valve for implementation of automatic immunosorbent renewal, rendering a new recognition surface for each sample. The sequential (or simultaneous) perfusion of CBZ and the horseradish peroxidase-labelled CBZ through the microbeads is followed by real-time on-column Monitoring of substrate (3,30,5,50-tetramethylbenzidine) oxidation by colorimetry. The evaluation of the initial oxidation rate and also the absorbance value at a fixed time point provided a linear response versus the logarithm of the CBZ concentration. Under the selected assay conditions, a single analysis was completed after only 11 min, with a quantification range between 1.0 and 50 µg L⁻¹. Detection of CBZ levels in undiluted wastewater samples was feasible after a simple filtration step while good recoveries were attained for spiked certified human serum, analyzed without sample clean-up.
Cancer cell lipid class homeostasis is altered under nutrient-deprivation but stable under hypoxia
(2019)
Background: Cancer cells modify the balance between fatty acid (FA) synthesis and uptake under metabolic stress, induced by oxygen/nutrient deprivation. These modifications were shown to alter the levels of individual triglyceride (TG) or phospholipid sub-species. To attain a holistic overview of the lipidomic profiles of cancer cells under stress we performed a broad lipidomic assay, comprising 244 lipids from six major classes. This assay allowed us to perform robust analyses and assess the changes in averages of broader lipid-classes, stratified on the basis of saturation index of their fatty-acyl side chains.
Methods: Global lipidomic profiling using Liquid Chromatography-Mass Spectrometry was performed to assess lipidomic profiles of biologically diverse cancer cell lines cultivated under metabolically stressed conditions.
Results: Neutral lipid compositions were markedly modified under serum-deprived conditions and, strikingly, the cellular level of triglyceride subspecies decreased with increasing number of double bonds in their fatty acyl chains.
In contrast and unexpectedly, no robust changes were observed in lipidomic profiles of hypoxic (2% O2) cancer cells despite concurrent changes in proliferation rates and metabolic gene expression.
Conclusions: Serum-deprivation significantly affects lipidomic profiles of cancer cells. Although, the levels of individual lipid moieties alter under hypoxia (2% O2), the robust averages of broader lipid classes remain unchanged.
Metallic nanoparticles (NPs) are currently applied in a variety of consumer products and are also attractive for medical applications. With their widespread use, the potential for human exposure to NPs — either intended or unintended — is increasing. Therefore, many studies have evaluated the toxicity and transport mechanism of NPs. In comparison with two-dimensional cultured cells, multicellular spheroids (MCS) look promising to be used as a three-dimensional cellular model, having unique advantages in nanoparticle studies due to the fact that interactions with excreted extracellular matrix can be investigated. Fibroblast cells are one of the most important cell systems to express a microenvironment by excreting an abundant extracellular matrix. For bioimaging laser ablation inductively coupled-plasma mass spectrometry (LA-ICP-MS) is used in this investigation to study the interaction of metallic NPs with MCS for multi-element detection offering a wide dynamic range. As a mass spectrometer we have applied a time-of-flight (TOF) instrument for (quasi-) simultaneous detection of all isotopes of elements of interest.
The aim of this study is to investigate the localization of silver (Ag) NPs exposed to fibroblast MCSs by means of LA-ICP-TOF-MS. In addition, for demonstrating elemental microscopy we chose phosphorous (31P) and iron (56Fe) to visualize regions of enriched extracellular matrix and single cells, respectively. In this presentation, we show that exposed Ag NPs are highly accumulated at the same position of single cells in an outer rim of fibroblast MCSs.
Immunochemical techniques are the workhorse for sample enrichment and detection of a large variety of analytes. In contrast to classical microtiter plate-based assays, microparticles are a next generation solid support, as they promote automation of immunoassays using flow-based techniques. Antibody immobilization is a crucial step, as these reagentsmare expensive, and inefficient coupling can result in low sensitivities. This paper proposes a general procedure for efficient immobilization of antibodies onto TentaGel particles, via Nhydroxysuccinimide chemistry. The goal was the preparation of solid supports with optimum immunorecognition, while increasing the sustainability of the process. The influence of buffer composition, activation and coupling time, as well as the amount of antibody on the immobilization efficiency was investigated, resorting to fluorophore-labeled proteins and fluorescence imaging. Buffer pH and activation time are the most important parameters for efficient coupling. It is demonstrated, that the hydrolysis of N-hydroxysuccinimide esters occurs at similar rates as in solution, limiting the utilizable time for coupling. Finally, applicability of the generated material for automated affinity extraction is demonstrated on the mesofluidic platform lab-on-valve.
Nontargeted high-resolution mass spectrometry (HRMS) is widely used for small molecule screening in biotic or abiotic samples. However, HRMS approaches like metabolomics or environmental nontarget screening currently still lack confidence in chemical annotation, i.e. computational structure assignment to all measured mass signals. As a crucial step within the annotation pipeline, molecular weight inference (MWI) deduces a compound’s intact mass from diagnostic mass differences between MS1 peaks, allowing precise database queries in subsequent steps. As the common practice of considering all possible ionization products such as adducts, multimers, multiple charges etc. in MWI suffers from high false positive rates, we aimed at selecting candidate ionization products in a chemically sensitive way. Generally, electrospray ionization produces different types of adducts depending on chromatographic system and sample matrix, necessitating application-specific optimization for optimum MWI performance. To avoid, however, the tedious and potentially biased manual data curation connected to optimization, we established an R-based workflow for automating this task. The workflow consists of two parts. Part 1 creates an MS1 spectral library by performing peak detection, spectral deconvolution and target peak assignment based on density estimation. Part 2 analyzes ion relationships within the library and returns a list of detected ionization products ranked by their frequency. We applied the workflow to a commercial 634-compound library that was acquired for two chromatographic methods (reverse phase, RP; hydrophilic liquid interaction chromatographic, HILIC) and the two ESI modes (positive, negative). As expected, different frequency distributions of ionization products were found for the two chromatographies. Interestingly, however, some of the differences were expected in terms of solvent chemistries (e.g. [M+NH4]+ in ammonium formate-buffered HILIC) while others indicated more complex ion competition (e.g. abundant [M+K]+, [M+2K-H]+ in HILIC). This demonstrated the relevance of this empirical approach. We further show that MWI accuracy clearly benefitted from derived optimized adduct lists – by adding filters or weighting terms – and present FDR calculations supporting this observation. We conclude that chemistry-aware compound annotation based on the combination of high-throughput library acquisition and statistical analysis holds significant potential for further improvements in nontargeted small molecule HRMS.
Comparing Nontargeted LC-MS Methods by Co-visualizing Linear Dynamic Range and Chemical Coverage
(2019)
INTRODUCTION
Biological and environmental samples contain thousands of small molecule species that all vary in chemical properties and concentration range. Identifying and quantifying all these chemical entities remains a long-term goal in metabolomics and related systems approaches. Due to its broad selectivity, nontargeted LC-MS is usually the method of choice for broad chemical screening. Optimizing nontargeted LC-MS methods, however, is less straightforward than for targeted methods where sensitivity, specificity, linearity etc. serve as well-established performance criteria. We therefore investigated linear dynamic range (LDR) and chemical classification as alternative performance criteria to guide nontargeted method development.
EXPERIMENTAL METHODS
LDR was defined as the linear portion of a feature’s response curve over multiple concentration levels. Comparing the LDR of features across methods can be expected to be significantly more robust than comparing signal intensities for a single concentration. To determine LDR for all features, a computational workflow was implemented in the R programming language. For estimating the linear portion of a curve, several mathematical approaches including linear, non-linear and piecewise linear regression were evaluated. Chemical classification was based on ClassyFire, which computes chemical classes for a given structure. To avoid false classifications for incorrectly annotated compounds, we took the following statistical approach. For each compound, multiple likely annotation hypotheses were derived using a recently described workflow[2]. All annotation hypotheses were submitted to ClassyFire and obtained classifications were ranked by frequency. The most frequently suggested class was kept for further analysis. Finally, LDR and chemical classes were visualized together on a molecular network, which was constructed using the well-established MS/MS similarity approach.
RESULTS AND DISCUSSION
For technical validation of the workflow, several hundred curve fits obtained from the different regression models were reviewed visually. Piecewise linear regression performed the most reliably with respect to the heterogeneous curve shapes of ‘real-life’ features. Validation of chemical classification was performed against a compound library, which showed that 90% of ~450 library compounds were correctly classified using the described approach. Two liquid chromatography methods (HILIC, RPC) as well as two electrospray ionization variants (low/high-temperature ESI) applied to urinary metabolomics were exemplarily studied to test the workflow. Molecular network visualization indicated that of all analytical setups, HILIC/high temperature ESI performed best in terms of high LDR achieved over a wide range of compound classes. Despite one order of magnitude lower sensitivity, HILIC/low temperature ESI showed similar chemical coverage, except for organic nitrogen compounds that were underrepresented compared to high-temperature ESI. Both RPC setups were inferior to the HILIC setups in terms of high-LDR features, supporting previous findings for the given matrix. The higher relative representation of benzenoids and lipids in RPC demonstrated that the workflow successfully captured expected selectivity differences between chromatographies.
CONCLUSION
When comparing nontargeted LC-MS methods for optimization purposes, ideally all available quantitative and qualitative information should be integrated. The present workflow follows this idea. Visualizing LDR and chemical classes of all features on a molecular network quickly indicated differences in method selectivity that were otherwise difficult to spot. As an automated approach, it is easily applied to repeated optimization steps, enabling effective optimization strategies.
Warfarin als ein Vertreter der NSO-Hetereozyklen, ist seit den 1950er Jahren einer der bekanntesten Gerinnungshemmer. Beim Menschen wird es bis heute zur Vorbeugung von Thrombose und der Behandlung von Vorhofflimmern und Arrhythmie eingesetzt. Doch schon einige Jahre vor der FDA Zulassung als Medikament wurde es zur Bekämpfung von Nagetieren eingesetzt. Bis heute wurde es nur teilweise durch weitaus wirksamere antikoagulante Rodentizide (ARs) der zweiten Generation, sogenannte Superwarfarine, ersetzt. In der Fachliteratur finden sich zahlreiche Beispiele für sekundäre und tertiäre Vergiftung mit ARs bei Wildtieren und anderen Nichtzieltieren. Bisher ist relativ wenig über die Bioakkumulation, Persistenz und Toxizität von ARs und deren Transformationsprodukten (TPs) in der terrestrischen und aquatischen Umwelt, sowie der Nahrungskette bekannt.
Um Einblicke in mögliche Transformations- und Abbauprozesse von Warfarin zu erhalten und um Umwelteinflüsse zu simulieren, wurde es in einer elektrochemischen Reaktorzelle oxidativ umgesetzt und mittels Massenspektrometrie analysiert. Hinsichtlich der Wasseraufbereitung in Kläranlagen wurden technisch relevante Simulationsverfahren wie Chlorung, UV-Bestrahlung und Ozonung angewendet um potentielle Eliminierungswege aufzuklären. Gebildete Transformationsprodukte wurden daher mittels unterschiedlicher chromatografischer Verfahren getrennt, massenspektrometrisch analysiert und verglichen.
Warfarin, also known as Coumadin is one of the most popular anticoagulant drugs used as a therapeutic in humans to prevent thrombosis, atrial fibrosis, and fibrillation since the 1950s. Because of its ability to hinder blood from clotting by blocking vitamin K-depending carboxylation of blood clotting precursors, it is also used as a rodenticide worldwide. Until today it has been partially substituted by far more potent anticoagulant rodenticides (ARs), so-called superwarfarins. There are numerous references confirming secondary and tertiary poisoning in non-target-animals and wildlife like mammals, birds, and fish associated with ARs. Up to now relatively little is known about persistence and toxicity of transformation products of those AR in the environment and food chain. Herein, warfarin was chosen as a model compound to determine andelucidate TPs which are generated technically and under environment-like conditions. Such as the simulation of the oxidative phase I metabolism by implementing electrochemical flow cells coupled to mass spectrometry (MS). Obtained results are being compared to TPs generated by UVB-irradiation and ozonation.
Analysis and separation of degradation products and TPs were achieved by a variety of gas- and liquid chromatographic techniques coupled to (high resolution) MS.
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances at the PNEC level are still challenging to achieve. The project EDC-WFD “Metrology for monitoring endocrine disrupting compounds under the EU Water Framework Directive” aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1)). Estrogens 17-alpha-estradiol (17aE2) and estriol (E3) will be included to demonstrate the reliability of the developed methods - Mass Spectrometry based method and effect-based methods (EBM) - and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. During the EDC-WFD project four EBM will be deeply investigated in order to improve their rationale use and their support in water quality assessment.
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances at the PNEC level are still challenging to achieve. The project EDC-WFD “Metrology for monitoring endocrine disrupting compounds under the EU Water Framework Directive” aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1)). Estrogens 17-alpha-estradiol (17aE2) and estriol (E3) will be included to demonstrate the reliability of the developed methods - Mass Spectrometry based method and effect-based methods (EBM) - and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. During the EDC-WFD project four EBM will be deeply investigated in order to improve their rationale use and their support in water quality assessment.
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances at the PNEC level are still challenging to achieve. The project EDC-WFD “Metrology for monitoring endocrine disrupting compounds under the EU Water Framework Directive” aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1)). Estrogens 17-alpha-estradiol (17aE2) and estriol (E3) will be included to demonstrate the reliability of the developed methods - Mass Spectrometry based method and effect-based methods (EBM) - and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. During the EDC-WFD project four EBM will be deeply investigated in order to improve their rationale use and their support in water quality assessment.
Commercial bead-based assays are commonly built upon polystyrene particles. The polymeric carrier can be encoded with organic dyes and has ideal material properties for cytometric applications such as low density and high refractive index. However, functional groups are conventionally integrated during polymerization and subsequent modification is limited to the reactivity of those groups. Additionally, polystyrene as the core material leads to many hydrophobic areas still being present on the beads’ surfaces even after functionalization, Rendering the particles prone to nonspecific adsorption during an application. The latter calls for several washing steps and the use of additives in (bio)analytical assays. In this contribution, we show how these limitations can be overcome by using monodisperse polystyrene (PS) core/silica (SiO2) shell particles (SiO2@PS). Two different hydrophobic BODIPY (boron−dipyrromethene) dyes were encapsulated inside a poly(vinylpyrrolidone) (PVP) -stabilized polystyrene core in different concentrations to create 5-plex arrays in two separate detection channels of a cytometer. A subsequent modification of the silica shell with an equimolar APTES/PEGS (aminopropyltriethoxysilane/polyethylene glycol silane) blend added multifunctional properties to the hybrid core/Shell microparticles in a single step: APTES provides amino groups for the attachment of a caffeine derivative (as a hapten) to create antigen-coupled microspheres; the PEG moiety effectively suppresses nonspecific binding of antibodies, endowing the surface with antifouling properties. The particles were applied in a competitive fluorescence immunoassay in suspension, and a highly selective wash-free assay for the detection of caffeine in beverages was developed as a proof of concept.
Extraction, chromatographic separation, and quantification of low-concentration organic compounds in complex matrices are core challenges for reference material producers and providers of calibration services. Evidence of successful participation in formal, relevant international comparisons is needed to document measurement capability claims made by national metrology institutes (NMIs) and designated institutes (DIs). To enable NMIs and DIs to update or establish their claims, in 2014 the Organic Analysis Working Group (OAWG) initiated CCQM-K95.1 "Low-Polarity Analytes in a Botanical Matrix: Polycyclic Aromatic Hydrocarbons (PAHs) in Tea". This was a follow-on comparison from CCQM-K95 which was completed in 2014.
The polycyclic aromatic hydrocarbons (PAHs) benz[a]anthracene (BaA) and benzo[a]pyrene (BaP) are considered priority pollutants by U.S. Environmental Protection Agency and are regulated contaminants in food, pose chromatographic separation challenges, and for which exist well-characterized measurement procedures and standard materials. BaA and BaP in a smoked tea were therefore selected as representative target measurands for CCQM-K95.1. Ten NMIs participated in CCQM-K95.1. The consensus summary mass fractions for the two PAHs are in the range of (50 to 70) ng/g with relative standard deviations of (6 to 10) %.
Successful participation in CCQM K95.1 demonstrates the following measurement capabilities in determining mass fraction of organic compounds, with molar mass of 100 g/mol to 500 g/mol and having polarity pKow −2, in a botanical matrix ranging in mass fraction from 10 ng/g to 1000 ng/g: (1) value assignment of primary reference standards (if in-house purity assessment carried out), (2) value assignment of single and/or multi-component organic solutions, (3) extraction of analytes of interest from the matrix, (4) cleanup and separation of analytes of interest from interfering matrix or extract components, and (5) separation and quantification using gas chromatography or liquid chromatography.
Solutions of organic analytes of known mass fraction are typically used to calibrate the measurement processes used to determine these compounds in matrix samples. Appropriate value assignments and uncertainty calculations for calibration solutions are critical for accurate measurements. Evidence of successful participation in formal, relevant international comparisons is needed to document measurement capability claims (CMCs) made by national metrology institutes (NMIs) and designated institutes (DIs). To enable NMIs and DIs to update or establish their claims, in 2015 the Organic Analysis Working Group (OAWG) sponsored CCQM-K131 "Low-Polarity Analytes in a Multicomponent Organic Solution: Polycyclic Aromatic Hydrocarbons (PAHs) in Acetonitrile".
Polycyclic aromatic hydrocarbons (PAHs) result from combustion sources and are ubiquitous in environmental samples. The PAH congeners, benz[a]anthracene (BaA), benzo[a]pyrene (BaP), and naphthalene (Nap) were selected as the target analytes for CCQM-K131. These targets span the volatility range of PAHs found in environmental samples and include potentially problematic chromatographic separations. Nineteen NMIs participated in CCQM-K131. The consensus summary mass fractions for the three PAHs are in the range of (5 to 25) μg/g with relative standard deviations of (2.5 to 3.5) %.
Successful participation in CCQM-K131 demonstrates the following measurement capabilities in determining mass fraction of organic compounds of moderate to insignificant volatility, molar mass of 100 g/mol up to 500 g/mol, and polarity pKow < −2 in a multicomponent organic solution ranging in mass fraction from 100 ng/g to 100 μg/g: (1) value assignment of primary reference standards (if in-house purity assessment carried out), (2) value assignment of single and/or multi-component organic solutions, and (3) separation and quantification using gas chromatography or liquid chromatography.
We have applied laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) with subcellular resolution as an elemental mass microscope to investigate the distributions of Ag nanoparticles (NP) in a 3-dimentional multicellular spheroid (MCS) model. The production of MCS has been optimized by changing the seeding cell number (500 to 40,000 cells) and the growth period (1 to 10 days). Incubations of MCS with Ag nanoparticle suspensions were performed with a concentration of 5 µg mL-1 for 24 hours. Thin-sections of the Eosin stained MCS were analysed by elemental mass microscopy using LA-ICP-MS to image distributions of 109Ag, 31P, 63Cu, 66Zn and 79Br. A calibration using NP suspensions was applied to convert the measured Ag intensity into the number of particles being present in each measurement pixel. The numbers of NP determined ranged from 30 up to 4,000 particles in an enrichment zone. The particle distribution was clearly correlated to 31P, 66Zn and 79Br and was localized in an outer rim of proliferating cells (confirmed by DAPI) with a width of about two-single cell diameters. For the highest seeding cell number NPs were only detected in this outer rim, whereas small molecules as for instance 79Br and 109Ag ions were detected in the core of the MCS as well. Aniline blue staining demonstrated that this outer rim was rich in collagen structures in which fibroblast cells were embedded and a thin-membrane was visible which separated the core from the biological active cell layer functioning as biological barriers for NP transport. In this presentation, we will show the possibility using this 3-dimensional model for toxicological and medical applications.
Clinical, environmental, and food analysis, require efficient and accurate quantitative analysis. Immunoassays take advantage of highly selective and affine binding of an antibody towards an antigen, being easy-to-use and allowing for high sample throughput. However, common immunoassays, e. g. ELISA are not capable of multiplexed analysis, thus limiting possible applications. On the other hand, multi-analyte methods, e.g. liquid chromatographytandem mass spectrometry requires expensive equipment, trained analysts and the time of analysis usually limits sample throughput. This bottleneck can be overcome combining the suspension array technology, where particles are encoded to allow multiplexed detection, with fluorescence immunoassays to create suspension array fluorescence immunoassays (SAFIA).
Polystyrene core/silica shell microparticles serve as platform for SAFIA. While an encoding dye is introduced in the polystyrene core, the silica shell is used for immobilization: For competitive hapten immunoassays small molecules are immobilized on the surface, serving as a competitive binding site for selective antibodies. For quantification of proteins, antibodies can be immobilized on the surface and the sandwich immunoassay format can be employed. All mentioned immunoassays can be executed wash-free and highly parallelized, allowing up to 500 determinations within three hours. In contrast to ELISA, short incubation times, a wash-free mix-and-read procedure and automated flow-cytometric read-out makes SAFIA applicable for even non-trained personal.
SAFIA showed excellent performance in studies on the origin and fate of drug residues in waste water, which is important to assess clearance rates of wastewater treatment plants. Furthermore, SAFIA can be employed in environmental screenings, detecting pollution of natural river waters by tracking anthropogenic marker substances. It was successfully employed in clinical and food analysis applications, e.g. the quantification of the anti-inflammatory drug diclofenac in breast milk or the quantification of caffeine in beverages. Due to multiplexing capacities, SAFIA can significantly improve biotechnological processes, as in the screening of hybridoma cells for selective and efficient antibody production. For small molecule analytes, limits of detection down to 4 ng/L and for proteins below 25 ng/mL (IgG) were observed, which makes SAFIA applicable to all addressed analytical issues. Moreover, in the analysis of real-world samples, SAFIA shows higher accuracy in contrast to ELISA, indicating higher matrix stability and thus higher robustness in analysis.
Spheriplex multiplexed immunoassays: A practical tool for environmental, food and bioanalysis
(2019)
Clinical, environmental, and food analysis, require efficient and accurate quantitative analysis. Immunoassays take advantage of highly selective and affine binding of an antibody towards an antigen, being easy-to-use and allowing for high sample throughput. However, common immunoassays, e. g. ELISA are not capable of multiplexed analysis, thus limiting possible applications. On the other hand, multi-analyte methods, e.g. liquid chromatographytandem mass spectrometry requires expensive equipment, trained analysts and the time of analysis usually limits sample throughput. This bottleneck can be overcome combining the suspension array technology, where particles are encoded to allow multiplexed detection, with fluorescence immunoassays to create suspension array fluorescence immunoassays (SAFIA).
Polystyrene core/silica shell microparticles serve as platform for SAFIA. While an encoding dye is introduced in the polystyrene core, the silica shell is used for immobilization: For competitive hapten immunoassays small molecules are immobilized on the surface, serving as a competitive binding site for selective antibodies. For quantification of proteins, antibodies can be immobilized on the surface and the sandwich immunoassay format can be employed. All mentioned immunoassays can be executed wash-free and highly parallelized, allowing up to 500 determinations within three hours. In contrast to ELISA, short incubation times, a wash-free mix-and-read procedure and automated flow-cytometric read-out makes SAFIA applicable for even non-trained personal.
SAFIA showed excellent performance in studies on the origin and fate of drug residues in waste water, which is important to assess clearance rates of wastewater treatment plants. Furthermore, SAFIA can be employed in environmental screenings, detecting pollution of natural river waters by tracking anthropogenic marker substances. It was successfully employed in clinical and food analysis applications, e.g. the quantification of the anti-inflammatory drug diclofenac in breast milk or the quantification of caffeine in beverages. Due to multiplexing capacities, SAFIA can significantly improve biotechnological processes, as in the screening of hybridoma cells for selective and efficient antibody production. For small molecule analytes, limits of detection down to 4 ng/L and for proteins below 25 ng/mL (IgG) were observed, which makes SAFIA applicable to all addressed analytical issues. Moreover, in the analysis of real-world samples, SAFIA shows higher accuracy in contrast to ELISA, indicating higher matrix stability and thus higher robustness in analysis.
Das Therapeutikum Warfarin ist bis heute der bekannteste Vertreter der antikoagulanten Rodentizide. In dieser Arbeit wurden Phase I Metabolite mittels einer elektrochemischen Durchflusszelle simuliert und analysiert. Weitere Transformations- und Abbauprozesse wurde durch UV-Bestrahlung und Ozonung generiert, gaschromatographisch getrennt und miteinander verglichen.
We have efficiently produced collagen-rich microstructures in fibroblast multicellular spheroids (MCSs) as a three-dimensional in vitro tissue analog to investigate silver (Ag) nanoparticle (NP) penetration. The MCS production was examined by changing the seeding cell number (500 to 40,000 cells) and the growth period (1 to 10 days). MCSs were incubated with Ag NP suspensions with a concentration of 5 μg/mL for 24 h. For this study, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used to visualize Ag NP localization quantitatively. Thin sections of MCSs were analyzed by LA-ICP-MS with a laser spot size of 8 μm to image distributions of 109Ag, 31P, 63Cu, 66Zn, and 79Br. A calibration using a NP suspension was applied to convert the measured Ag intensity into the number of NPs present. The determined numbers of NPs ranged from 30 to 7200 particles in an outer rim of MCS. The particle distribution was clearly correlated with the presence of 31P and 66Zn and was localized in the outer rim of proliferating cells with a width that was equal to about twice the diameter of single cells. Moreover, abundant collagens were found in the outer rim of MCSs. For only the highest seeding cell number, NPs were completely captured at the outer rim, in a natural barrier reducing particle transport, whereas Eosin (79Br) used as a probe of small molecules penetrated into the core of MCSs already after 1 min of exposure.
The efficiency, relatively low cost and eco-friendly nature of hydrogen peroxide-assisted photocatalysis treatment procedures are significant advantages over conventional techniques for wastewater remediation. Herein, we evaluate the behaviour of g-cyclodextrin (g-CD) immobilised on either bare or chitosan (CS)–functionalised Fe3O4 nanoparticles, for photodegrading Bisphenol A (BPA) in ultrapure water and in real wastewater samples. The BPA removal efficiencies with Fe3O4/g-CD and Fe3O4/CS/g-CD were compared with those of Fe3O4/b-CD, and were monitored under UVA irradiation at near-neutral pH. The addition of H2O2 at low concentrations (15 mmol L-1) significantly increased BPA photodegradation in the presence of each nanocomposite. The highest catalytic activity was shown by both Fe3O4/g-CD and Fe3O4/CS/g-CD nanocomposites (,60 and 27%BPA removal in ultrapure water and real wastewater effluent, respectively). Our findings reveal the superior performance of g-CD-functionalised Fe3O4 relative to that of Fe3O4/b-CD. The use of CD-based nanocomposites as photocatalytic materials could be an attractive option in the pre- or post-treatment stage of wastewaters by advanced oxidation processes before or after biological treatment.
Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umwelt-beständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe (polybromierte Flammschutzmittel) in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden.
In addition to previously reported results on the accelerated weathering of polystyrene samples (PS) containing 1 wt.% hexabromocyclododecane (HBCD), we present the first results of our investigations of polypropylene samples (PP) containing 0.1 wt.% BDE-209. All studied polymer samples were exposed to a defined weathering schedule in a climate chamber in accordance to regulation EN ISO 4892-3:2006. For the determination of BDE-209 in the collected raining water the samples were prepared in accordance to a validated protocol. Before the analyses each sample was spiked with isotopically labeled BDE-209. Subsequently the samples were extracted with isooctane. The obtained extracts were concentrated, and the resulting solutions were analyzed by GC/MS. Additionally, the total bromine content was monitored for the weathered and untreated samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and X-ray fluorescence analysis (XRF) as a non-destructive and rapid method. In general, the resulting data from the accelerated weathering will be compared to those from the natural weathering experiments. Here, the surfaces of the test pieces were analyzed by LA-ICP-MS and XRF as well. Moreover, soil bed tests were conducted in a well characterized model soil. This soil (boulder-clay, sand with 12 % loam, particle size in total 0.2-4 mm) is filled in a free-draining basin inside of an air-conditioned cellar. In this manner, TOC, water capacity and humidity are recorded parameters. To induce a leaching process from the samples by the raining water, the target water content is calculated to 8%. The actual humidity is measured by a tensiometer, assuring the duration of the raining period. A defined humidity is a fundamental parameter for a biological activity in the soil. The test polymers were placed up to the half in the soil. Microbial activity of the soil is monitored by a reference polymer (polyurethane) and should induce the release of HBCD and BDE-209 out of the test materials. These released analytes will be captured by passive samplers (silicone tubes) placed in a distinct distance to the polymer samples in the soil. The soil bed experiments are complementary to the weathering experiments due to the biological activity in the soil.
Environmental sustainability and –stability of materials concerning the migration of pollutants
(2019)
In addition to previously reported results on the accelerated weathering of polystyrene samples (PS) containing 1 wt. % hexabromocyclododecane (HBCD), we present the first results of our investigations of polypropylene samples (PP) containing 0.1 wt. % BDE-209. All studied polymer samples were exposed to a defined weathering schedule in a climate chamber in accordance to regulation EN ISO 4892-3:2006. For the determination of BDE-209 in the collected raining water the samples were prepared in accordance to a validated protocol. Before the analyses each sample was spiked with isotopically labeled BDE-209. Subsequently the samples were extracted with isooctane. The obtained extracts were concentrated, and the resulting solutions were analyzed by GC/MS. Additionally, the total bromine content was monitored for the weathered and untreated samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and X-ray fluorescence analysis (XRF) as a non-destructive and rapid method. In general, the resulting data from the accelerated weathering will be compared to those from the natural weathering experiments. Here, the surfaces of the test pieces were analyzed by LA-ICP-MS and XRF as well. Moreover, soil bed tests were conducted in a well characterized model soil. This soil (boulder-clay, sand with 12 % loam, particle size in total 0.2-4 mm) is filled in a free-draining basin inside of an air-conditioned cellar. In this manner, TOC, water capacity and humidity are recorded parameters. To induce a leaching process from the samples by the raining water, the target water content is calculated to 8%. The actual humidity is measured by a tensiometer, assuring the duration of the raining period. A defined humidity is a fundamental parameter for a biological activity in the soil. The test polymers were placed up to the half in the soil. Microbial activity of the soil is monitored by a reference polymer (polyurethane) and should induce the release of HBCD and BDE-209 out of the test materials. These released analytes will be captured by passive samplers (silicone tubes) placed in a distinct distance to the polymer samples in the soil. The soil bed experiments are complementary to the weathering experiments due to the biological activity in the soil.
In addition to previously reported results on the accelerated weathering of polystyrene samples (PS) containing 1 wt.% hexabromocyclododecane (HBCD), we present the first results of our investigations of polypropylene samples (PP) containing 0.1 wt.% BDE-209. All studied polymer samples were exposed to a defined weathering schedule in a climate chamber in accordance to regulation EN ISO 4892-3:2006. For the determination of BDE-209 in the collected raining water the samples were prepared in accordance to a validated protocol. Before the analyses each sample was spiked with isotopically labeled BDE-209. Subsequently the samples were extracted with isooctane. The obtained extracts were concentrated, and the resulting solutions were analyzed by GC/MS. Additionally, the total bromine content was monitored for the weathered and untreated samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and X-ray fluorescence analysis (XRF) as a non-destructive and rapid method. In general, the resulting data from the accelerated weathering will be compared to those from the natural weathering experiments. Here, the surfaces of the test pieces were analyzed by LA-ICP-MS and XRF as well. Moreover, soil bed tests were conducted in a well characterized model soil. This soil (boulder-clay, sand with 12 % loam, particle size in total 0.2-4 mm) is filled in a free-draining basin inside of an air-conditioned cellar. In this manner, TOC, water capacity and humidity are recorded parameters. To induce a leaching process from the samples by the raining water, the target water content is calculated to 8%. The actual humidity is measured by a tensiometer, assuring the duration of the raining period. A defined humidity is a fundamental parameter for a biological activity in the soil. The test polymers were placed up to the half in the soil. Microbial activity of the soil is monitored by a reference polymer (polyurethane) and should induce the release of HBCD and BDE-209 out of the test materials. These released analytes will be captured by passive samplers (silicone tubes) placed in a distinct distance to the polymer samples in the soil. The soil bed experiments are complementary to the weathering experiments due to the biological activity in the soil.
Zu den letzten beiden Jahrestagungen der GUS wurden Verfahren und Methoden vorgestellt, die es gestatten, den Transfer von Schadstoffen aus Materialien und Produkten in die Umwelt unter umweltrelevanten Bedingungen beschreiben zu können. Dabei lag der Fokus auf den Materialien und der eingesetzten Umweltsimulationen. In einem sich anschließenden Schritt soll nun das Verhalten der freigesetzten organischen Schadstoffe unter den Bedingungen von realen und simulierten Umwelteinflüssen charakterisiert und beschrieben werden. Hier werden im Detail drei potentielle Schadstoffe betrachtet, die Inhaltsstoffe bzw. Additive in den jeweils eingesetzten Materialien sind. Im Falle von Polypropylen (PP) und Polystyrol (PS) handelt es sich um polybromierte Flammschutzmittel BDE 209 (Decabrom-diphenylether, als Einzelsubstanz) und HBCD (Hexabromcyclododecan, als technische Formulierung). Für das eingesetzte Polycarbonat ist BPA (Bisphenol A) als Schadstoff zu definieren, welcher unter umweltrelevanten Bedingungen freigesetzt wird. Im Rahmen der durchzuführenden Arbeiten sollen die aufgeführten prioritären Schadstoffe hinsichtlich möglicher Transformationsprozesse in Umwelt und Klärwerk charakterisiert werden. Die unter den Bedingungen der Ozonung, Chlorierung und UV-Bestrahlung erhaltenen Transformationsprodukte (TPs) sollen im Sinne einer Non-Target-Analytik identifiziert und eindeutig charakterisiert werden. Die Ergebnisse sollen mittels vorhandener Analysenverfahren, wie GC-EI-MS, HPLC-ESI-IT-MSn bzw. LC-MS/MS erzeugt bzw. abgesichert werden. Anhand der in der Struktur eindeutig zu beschreibenden Transformationsprodukte und der Charakterisierung von potentiellen Intermediaten sollen belastbare Reaktionswege und –mechanismen abgeleitet werden.
During the last two decades, studies related to the occurrence and fate of emerging contaminants in the aquatic environment have received great attention from the international scientific community. The monitoring of the presence of these compounds is particularly important since they are known to induce adverse effects in aquatic environments, even at extremely low concentrations. This work aimed to apply a simple and effective methodology, such as enzyme-linked immunosorbent assay (ELISA), in the monitoring of 17a-ethinylestradiol (EE2) and 17b-estradiol (E2) (a synthetic and a natural hormone, respectively), carbamazepine (CBZ, an antiepileptic), cetirizine (CET, an antihistamine) and caffeine (CAF, a stimulant) in water matrices with differing salinity and organic matter contents. ELISA was proven to be a valid and practical tool, especially for screening purposes in contrast to traditional chromatographic techniques which are prohibitively expensive for an application on a broader base. The main originality of this work was to establish seasonal and spatial effects on the occurrence of the referred contaminants by using the effectiveness of ELISA to screen those compounds in samples with different characteristics.
This work reports both the seasonal and spatial quantification of the referred contaminants in the aquatic environment of the central region of Portugal, with concentrations ranging as follows: 5–87 ng L-1, for
E2, 2–17 ng L-1, for EE2, 10–1290 ng L-1, for CBZ, 10–190 ng L-1, for CET, and 62–6400 ng L-1, for CAF.
Introduction
Aflatoxin B1 (AFB1) is a toxic low‐molecular‐weight secondary metabolite of Aspergillus flavus and A. parasiticus. AFB1 was classified as a Group I carcinogen by the World Health Organisation for Research on Cancer in 1993. AFB1 is an unavoidable natural contaminant of some herbal medicine, able to cause serious health issues for humans consuming the related medicine.
Objective
Therefore, this study aimed to develop an efficient fluorescence polarisation immunoassay (FPIA) and a rapid, low‐cost, and easy‐to‐use membrane‐based flow‐through immunoassay (MBA) for determination of AFB1 in herbal medicine Origanum vulgare L., Rubus idaeus L., Urtica dioica L. and Sorbus aucuparia L.
Results
A cut‐off level of the developed MBA was 0.8 ppb. Validation of the developed test was performed with blank and spiked samples. Using three naturally contaminated or three artificially spiked samples. The FPIA showed a linear working range of 8.6 to 64 ppb, and a half maximal inhibitory concentration (IC50) of 24 ppb.
Conclusion
The results were in good correlation with the enzymelinked immunosorbent assay (ELISA) results (the IC50 0.1 ppb). Both the sample preparation and analysis are simple, cost‐effective and easy to perform on‐site in non‐laboratory environments. Liquid chromatography with tandem mass spectrometry (LC‐MS/MS) was used as a confirmatory technique.
A lateral flow immunoassay (LFIA) using latex particles labeled with antibody to BSAclarithromycin (CLA) was developed for the rapid simultaneous group determination of six macrolide antibiotics. Optimization of antigen spotting on the membrane and latex probe loading allowed improving visual detectability (vLOD) 100 times, which was 1, 1, 10, 10, 50, and 1000 ng/mL for CLA, roxithromycin, erythromycin, dirithromycin, azithromycin, and oleandomycin in buffer, respectively. The calculated limits of instrumental detection (cLOD) were respectively 0.12, 0.15, 1.4, 2.1, 2.4, and 3.3 ng/mL. To avoid a strong influence of breast milk of a very diverse and variable composition, a sample pretreatment is proposed. The six macrolides mentioned can be visually detected in breast milk after 20 minutes pretreatment at concentrations of 10-1000 ng / ml or instrumentally with cLOD of 4.0, 2.5, 30, 42, 42 and 180 ng/mL. The recovery rate from the spiked samples carried out using a strip scanner device ranged from 71% to 110%, and precision expressed as relative standard deviation was between 3-14%. The described rapid on-site diagnostic assay format can be useful for monitoring the content of antibiotics in breast milk during macrolide treatment to ensure safe breastfeeding of infants.
Objectives: Porphyromonas gingivalis (P.g.) is discussed to be involved in triggering self-reactive immune responses. The aim of this study was to investigate the autocitrullinated prokaryotic peptidylarginine deiminase (PPAD) from P.g. CH2007 (RACH2007-PPAD) from a rheumatoid arthritis (RA) patient and a synthetic citrullinated PPAD peptide (CPP) containing the main autocitrullination site as potential targets for antibody reactivity in RA and to analyse the possibility of citrullinating native human proteins by PPAD in the context of RA.
Methods: Recombinant RACH2007-PPAD was cloned and expressed in Escherichia coli. Purified RACH2007-PPAD and its enzymatic activity was analysed using two-dimensional electrophoresis, mass spectrometry, immunoblot and ELISA. Autoantibody response to different modified proteins and peptides was recorded and bioinformatically evaluated.
Results: RACH2007-PPAD was capable to citrullinate major RA autoantigens, such as fibrinogen, vimentin, hnRNP-A2/B1, histone H1 and multiple peptides, which identify a common RG/RGG consensus motif. 33% of RA patients (n=30) revealed increased reactivity for α-cit-RACH2007-PPAD before RA onset. 77% of RA patients (n=99) presented α-cit-specific signals to CPP amino acids 57-71 which were positively correlated to α-CCP2 antibody levels. Interestingly, 48% of the α-CPP-positives were rheumatoidfactor IgM/anti-citrullinated peptide/protein antibodies (ACPA)-negative. Anti-CPP and α-RACH2007-PPAD antibody levels increase with age. Protein macroarrays that were citrullinated by RACH2007-PPAD and screened with RA patient sera (n=6) and controls (n=4) uncovered 16 RACH2007-PPAD citrullinated RA autoantigens and 9 autoantigens associated with lung diseases. We showed that the α-CPP response could be an important determinant in parenchymal changes in the lung at the time of RA diagnosis (n=106; p=0.018).
Conclusions: RACH2007-PPAD induced internal citrullination of major RA autoantigens. Anti-RACH2007-PPAD correlates with ACPA levels and interstitial lung disease autoantigen reactivity, supporting an infection-based concept for induction of ACPAs via enzymatic mimicry.
Toxic secondary metabolites produced by fungi (aka mycotoxins) are often identified as contaminants in cereals or other food and pose a severe health risk, since they can be carcinogenic, neurotoxic, mutagenic or harmful in other respect. The highly nephrotoxic ochratoxin A (OTA) is one of the most important and widespread mycotoxins found in grains such as rye, wheat or oats. Thus, the fast and cost-effective detection of OTA is of great importance, to ensure that the toxin concentration is below the legal limits. Currently, the mycotoxin detection in mill operations is typically performed by means of the antibody-based ELISA method, which requires extensive laboratory equipment and specialized personnel. It was the aim of this study to develop an ELISA-inspired sensor method enabling the on-site quantification of OTA. Based on a classical competitive ELISA, an electrochemical detection system was developed. Anti-OTA-antibodies were captured on magnetic beads on which the competitive affinity reaction between OTA and an OTA- horseradish peroxidase (HRP) tracer was performed. Here the OTA concentration is inversely proportional to the amount of the bound OTA-HRP tracer, which was electrochemically quantified. For this purpose, oxidized tetramethylbenzidine (TMB), which is enzymatically produced by the reduction of H2O2 by the OTA-HRP tracer, is quantified by amperometry with screen-printed electrodes in a flow system. With this method a detection limit of 250 ng L-1 could be achieved which meets the current requirements for the detection of OTA in food and feed.
Toxic secondary metabolites produced by fungi (aka mycotoxins) are often
identified as contaminants in food and pose a severe health risk. Ochratoxin A
(OTA) is one of the most abundant mycotoxins found in grains such as wheat, rye
or oats. Thus, the fast and cost-effective detection of OTA is of great
importance, to ensure that the toxin concentration is below the legal limits.
Currently, mycotoxin detection in mill operations is typically performed by means
of the antibody-based ELISA (Enzyme-linked Immunosorbent Assay) method,
which requires extensive laboratory equipment and specialized personnel. The
aim of this project is to establish a more user-friendly detection method. Thus,
we developed a magnetic bead-based assay enabling the quantification of OTA
with a miniaturized potentiostat connected to a smartphone.
Pharmacologically active compounds are often detected in wastewater and surface waters. The nonsteroidal anti-inflammatory drug diclofenac (DCF) was included in the European watch list of substances that requires its environmental monitoring in the member states. DCF may harmfully influence the ecosystem already at concentrations ≤ 1 μg L−1. The fast and easy quantification of DCF is becoming a subject of global importance. Fluorescence polarization immunoassay (FPIA) is a homogeneous mix-and-read method which does not require the immobilization of reagents. FPIA can be performed in one phase within 20–30 min, making it possible to analyse wastewater without any complicated pre-treatment. In this study, new tracermolecules with different structures, linking fluorophores to derivatives of the analyte, were synthesized, three homologous tracers based on DCF, two including a C6 spacer, and one heterologous tracer derived from 5-hydroxy-DCF. The tracer molecules were thoroughly assessed for performance. Regarding sensitivity of the FPIA, the lowest limit of detection reached was 2.0 μg L−1 with a working range up to 870 μg L−1. The method was validated for real wastewater samples against LC-MS/MS as reference method with good agreement of both methods.
Sensors are the scientific and technological extension of human senses and enormously expand human capabilities. Despite the fact that scientific and technological advances are usually seen in a positive light, the name of this conference, Sensors for Good, put me in a bit of a trouble, because in general science does not operate in ethical categories, but instead it just tells how far from the truth one is. In this respect, sensors help us in recognizing states and events beyond our immediate reach. Fortunately, sensors are used for many applications, such as environmental monitoring, food control, and alike, which unequivocally benefit society.
I will focus on a particular type of sensors, those that rely on microfluidics for operation and which are typically realized in lab-on-a-chip (LOC) devices. In this domain, where at least one of the dimensions through which a fluid flows is submillimetric, our natural senses fail, because the phenomena are too small to be detected either by eye, smell, touch, and even the common sense explanation that we learn for many years in school is not applicable, because the phenomena are dominated by different parameters. To give one simple example, in general the direction of flow in microfluidic channels does not depend on the up-down direction of the channel, because gravitational force or the weight of the fluid is negligible compared to the viscous forces present on the chip.
This presentation consists of three parts: initially, two sensors produced in our lab are presented, followed by a simulation oriented discussion on microfluidics and biosensors, and finally a project in progress that we are involved in is presented, concluding with a list of open issues raised during the presentation.
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P216, was coordinated by the Chinese National Institute of Metrology (NIM), National Research Council of Canada (NRC) and the Bureau International des Poids et Mesures (BIPM). Eleven Metrology Institutes or Designated Institutes and the BIPM participated in the first phase of the pilot study (Part 1). The purpose of this pilot study was to develop measurement capabilities for larger proteins using a recombinant humanized IgG monoclonal antibody against Spike glycoprotein of SARS-CoV-2 (Anti-S IgG mAb) in solution. The first phase of the study was designed to employ established methods that had been previously studies by the CCQM Protein Analysis Working Group, involving the digestion of protein down to the peptide or amino acid level. The global coronavirus pandemic has also led to increased focus on antibody quantitation methods. IgG are among the immunoglobulins produced by the immune system to provide protection against SARS-CoV-2. Anti-SARS-CoV-2 IgG can therefore be detected in samples from affected patients. Antibody tests can show whether a person has been exposed to the SARS-CoV-2, and whether or not they potentially show lasting immunity to the disease. With the constant spread of the virus and the high pressure of re-opening economies, antibody testing plays a critical role in the fight against COVID-19 by helping healthcare professionals to identify individuals who have developed an immune response, either via vaccination or exposure to the virus. Many countries have launched large-scale antibody testing for COVID-19. The development of measurement standards for the antibody detection of SARS-CoV-2 is critically important to deal with the challenges of the COVID-19 pandemic. In this study, the SARS-CoV-2 monoclonal antibody is being used as a model system to build capacity in methods that can be used in antibody quantification. Amino acid reference values with corresponding expanded uncertainty of 36.10 ± 1.55 mg/kg, 38.75 ± 1.45 mg/kg, 18.46 ± 0.78 mg/kg, 16.20 ± 0.67 mg/kg and 30.61 ± 1.30 mg/kg have been established for leucine, valine, phenylalanine, isoleucine and proline, respectively. Agreement between nearly all laboratories was achieved for the amino acid analysis within 2 to 2.5 %, with one participant achieving markedly higher results due to a technical issue found in their procedure; this result was thus excluded from the reference value calculations. The relatively good agreement within a laboratory between different amino acids was not dissimilar to previous results for peptides or small proteins, indicating that factors such as hydrolysis conditions and calibration procedures could be the largest sources of variability. Peptide reference values with corresponding expanded uncertainty of 4.99 ± 0.28 mg/kg and 6.83 ± 0.65 mg/kg have been established for ALPAPIEK and GPSVFPLAPSSK, respectively. Not surprisingly due to prior knowledge from previous studies on peptide quantitation, agreement between laboratories for the peptide-based analysis was slightly poorer at 3 to 5 %, with one laboratory's result excluded for the peptide GPSVFPLAPSSK. Again, this level of agreement was not significantly poorer than that achieved in previous studies with smaller or less complex proteins. To reach the main text of this paper, click on Final Report.
Vergleichende Darstellung SARS-CoV-2-spezifischer Nanobodys aus unterschiedlichen Wirtsorganismen
(2021)
Aufgrund der anhaltenden COVID-19-Pandemie werden neutralisierende Therapeutika benötigt. Eine Möglichkeit zur Behandlung stellt die Verwendung monoklonaler Anti-SARS-CoV-2-Immun-globuline dar. Ihre Produktion in Säugetierzellen ist jedoch schwer skalierbar, um den weltweiten Bedarf zu decken. VHH-Antikörper, auch Nanobodys genannt, bieten hierfür eine Alternative, da sie eine hohe Temperaturstabilität aufweisen und eine kostengünstige Produktion in prokaryotischen Wirtsorganismen ermöglichen.
Warfarin ist seit den 1950er Jahren einer der bekanntesten Gerinnungshemmer. Beim Menschen wird es bis heute zur Vorbeugung von Thrombose und der Behandlung von Vorhofflimmern und Arrhythmie eingesetzt. Doch schon einige Jahre vor der FDA Zulassung (U. S. Food and Drug Administration) als Medikament wurde es zur Bekämpfung von Nagetieren eingesetzt. Bis heute wurde es nur teilweise durch weitaus wirksamere antikoagulante Rodentizide (ARs) der zweiten Generation, sogenannte Superwarfarine, ersetzt. In der Fachliteratur finden sich zahlreiche Beispiele für sekundäre und tertiäre Vergiftung mit ARs bei Wildtieren und anderen Nichtzieltieren. Bisher ist relativ wenig über die Bioakkumulation, Persistenz und Toxizität von ARs und deren Transformationsprodukten (TPs) in der terrestrischen und aquatischen Umwelt, sowie der Nahrungskette bekannt.
Um Einblicke in mögliche Transformations- und Abbauprozesse von Warfarin unter umweltrelevanten Bedingungen zu erhalten und um diese Einflüsse zu simulieren, wurde hierzu eine elektrochemische Reaktorzelle in Kopplung mit einem Massenspektrometer verwendet. So können mögliche Phase-I-Metabolite und sogenannte „oxidation products“ vorausgesagt werden. Hinsichtlich des Verhaltens während der Wasseraufbereitung in Kläranlagen wurden technisch relevante Prozesse wie Chlorung, UV-Bestrahlung und Ozonung in Modellen simuliert, um hier potenzielle Abbauwege und -prozesse aufzuklären. Gebildete Transformationsprodukte wurden daher mittels unterschiedlicher chromatografischer Verfahren getrennt und massenspektrometrisch identifiziert, charakterisiert und verglichen.
Increasing contamination of environmental waters with pharmaceuticals represents an emerging threat for the drinking water quality and safety. In this regard, fast and reliable analytical methods are required to allow quick countermeasures in case of contamination. Here, we report the development of a magnetic bead-based immunoassay (MBBA) for the fast and cost-effective determination of the analgesic diclofenac (DCF) in water samples, based on diclofenac-coupled magnetic beads and a robust monoclonal anti-DCF antibody. A novel synthetic strategy for preparation of the beads resulted in an assay that enabled for the determination of diclofenac with a significantly lower limit of detection (400 ng/L) than the respective enzyme-linked immunosorbent assay (ELISA). With shorter incubation times and only one manual washing step required, the assay demands for remarkably shorter time to result (< 45 min) and less equipment than ELISA. Evaluation of assay precision and accuracy with a series of spiked water samples yielded results with low to moderate intra- and inter-assay variations and in good agreement with LC–MS/MS reference analysis. The assay principle can be transferred to other, e.g., microfluidic, formats, as well as applied to other analytes and may replace ELISA as the standard immunochemical method.
Mit dem Testsystem zur Probe
(2021)
In this work, we report an electrochemical immunosensor to detect ethinylestradiol in water samples, using electrochemical impedance spectroscopy (EIS) as a detection technique. For the development of this immunosensor, the direct modification of the working electrode of a screen-printed carbon electrode was carried out. First, to reduce the resistance of the electrode, electroreduced graphene was incorporated on the surface.
Second, a porous gold structure was electrodeposited on reduced graphene by electrodeposition and the dynamic hydrogen bubble template assisted method. Thus, a marked increase in surface area was obtained for anti-EE2 antibodies immobilization. Subsequently, the specific anti-EE2 antibodies were covalently immobilized using α-lipoic acid for attaching them to the gold surface.
The electrode modified with the antibodies was incubated for 30 min in the samples containing EE2, producing the specific Antigen antibody binding. As the charge transfer resistance of a redox probe in the electrode surface is governed by the surface blocking effects, the charge transfer resistance was related to the amount of EE2 captured to realize a quantitative determination. For this, the EIS measurements were performed in a 4 mM [Fe(CN)6]4−/3− solution in 0.1 M KCl. The obtained Nyquist diagrams were adjusted using the Randles circuit as an equivalent circuit to obtain the corresponding resistances. The developed methodology showed good selectivity, precision, and sensitivity; although the LOD obtained was higher than those presented in other published articles, it turned out to be an alternative that allows the determination of ethinylestradiol using a simple disposable electrode.
One of the most important chemicals used in the production of polymer plastics and coatings is bisphenol A. However, despite the large number of studies on the toxicity and hormonal activity of BPA, there are still open questions and thus considerable media attention regarding BPA toxicity. Hence, it is necessary to develop a sensitive, simple, cost-efficient, specific, portable, and rapid method for monitoring bisphenol A and for high sample throughput and on-site screening analysis. Lateral flow immunoassays have potential as rapid tests for on-site screening. To meet sensitivity criteria, they must be carefully optimized. A latex microparticle-based LFIA for detection of BPA was developed. The sensitivity of the assay was improved by non-contact printing of spot grids as the control and test lines with careful parameter optimization. Results of the test could be visually evaluated within 10 min with a visual cut-off of 10 µg/L (vLOD). Alternatively, photographs were taken, and image analysis performed to set up a calibration, which allowed for a calculated limit of detection (cLOD) of 0.14 µg/L. The method was validated for thermal paper samples against ELISA and LC–MS/MS as reference methods, showing good agreement with both methods
Portable, antikörperbasierte Analysenverfahren für die Schadstofferfassung im Wasserkreislauf
(2021)
Die Wasseranalytik wird bestimmt von zwei Hauptbedarfen, einerseits der Erfassung der Gewässergüte und Grundwassergüte als Basis für die Bereitstellung einwandfreien Trinkwassers und zum anderen des Monitorings der Wasserqualität in den Prozessen der Wasseraufbereitung und der Abwasserreinigung. Für beide Anwendungsbereiche ist eine laborbasierte Analytik eher hinderlich, werden die Analysenergebnisse doch eigentlich vor Ort benötigt, um etwa Beprobungskampagnen rasch anpassen zu können. Des Weiteren werden die Daten auch schnell benötigt, um zeitnah in die technischen Prozesse einzugreifen. Organische Kontaminanten werden meist über chromatographische Verfahren, häufig gekoppelt mit einer massenspektrometrischen Detektion, in instrumentellen Labormethoden erfasst, und die hochauflösende Massenspektrometrie und die Non-target-Analytik haben viel zum Wissen über das Vorkommen, insbesondere von sogenannten „Emerging Contaminants“, beigetragen, sowie zum Verständnis der beteiligten Eintragspfade und Abbauwege. Moderne, portable Analysenmethoden und insbesondere Sensoren werden zukünftig aber ihren Platz in der Schadstofferfassung im Wasserkreislauf einnehmen. Dies gilt insbesondere für antikörperbasierte Analysenverfahren, da erst diese oft die nötige Selektivität und Sensitivität in die Detektionsmethoden einbringen.
Portable, antikörperbasierte Analysenverfahren für die Schadstofferfassung im Wasserkreislauf
(2021)
Die Wasseranalytik wird bestimmt von zwei Hauptbedarfen, einerseits der Erfassung der Gewässergüte und Grundwassergüte als Basis für die Bereitstellung einwandfrei-en Trinkwassers und zum anderen des Monitorings der Wasserqualität in den Prozes-sen der Wasseraufbereitung und der Abwasserreinigung. Für beide Anwendungsbe-reiche ist eine laborbasierte Analytik eher hinderlich, werden die Analysenergebnisse doch eigentlich vor Ort benötigt, um etwa Beprobungskampagnen rasch anpassen zu können. Desweiteren werden die Daten auch schnell benötigt, um zeitnah in die technischen Prozesse einzugreifen. Organische Kontaminanten werden meist über chromatographische Verfahren, häufig gekoppelt mit einer massenspektrometrischen Detektion, in instrumentelle Labormethoden erfasst und die hochauflösende Massen-spektrometrie und die Non-target-Analytik haben viel zum Wissen über das Vorkom-men, insbesondere von sog. „emerging contaminants“, beigetragen, sowie zum Ver-ständnis der beteiligten Eintragspfade und Abbauwege. Moderne, portable Analy-senmethoden und insbesondere Sensoren werden zukünftig aber ihren Platz in der Schadstofferfassung im Wasserkreislauf einnehmen. Dies gilt insbesondere für anti-körperbasierte Analysenverfahren, da erst diese oft die nötige Selektivität und Sensitivität in die Detektionsmethoden einbringen.