Analytische Chemie
Filtern
Erscheinungsjahr
- 2016 (2)
Dokumenttyp
- Vortrag (1)
- Posterpräsentation (1)
Sprache
- Englisch (2)
Referierte Publikation
- nein (2)
Schlagworte
- chemical sensing (2) (entfernen)
Eingeladener Vortrag
- nein (1)
Lanthanide-doped photon upconversion nanoparticles (UCNPs) exhibit many advantages compared to Stokes-shifted luminescent probes (organic dyes, quantum dots). Due to the upconversion process, the limitations of photobleaching, autofluorescence and low penetration depths in tissue shown by classical fluorescent probes are avoided. This makes UCNPs particularly useful for applications in complex biological samples. Sensing of intracellular pH is of particular interest in biomedical research since structure and function of biomolecules strongly depend on the concentration of protons in their environment.
Lanthanide-doped photon upconversion nanoparticles (UCNPs) exhibit many advantages compared to conventional Stokes-shifted luminescent probes such as organic dyes and quantum dots. Due to the upconversion (UC) process, which describes the conversion of NIR light into shorter wavelength radiation, the limitations of photobleaching, autofluorescence and low penetration depths in tissue shown by classical fluorescent probes absorbing in the UV/vis range are avoided. This makes UCNPs particularly useful for applications in complex samples occurring in bioanalysis, biomedicine and imaging.
Sensing of intracellular pH is of particular interest in biomedical research since structure and function of biomolecules strongly depend on the concentration of protons in their environment. We described previously a UCNP nanosensor for pH based on a resonance energy transfer from hexagonal nanocrystals of NaYF4: Yb3+,Er3+ to a pH-sensitive fluorophore (pHrodoTM Red).[1] The nanocrystals were coated with a thin shell of aminosilane with several nanometer layer thickness for coupling of the pH indicator.
In this contribution we present a new generation of UC nanoprobes that are coated with a layer of highly branched polyethylenimine (PEI). The PEI coating enables a higher coupling of indicator molecules on the particle surface, better signal to reference ratios in ratiometric readout and an improved cellular uptake compared to the aminosilane coated particles due to a more positive zeta potential. Again, pHrodoTM Red is used as pH indicator, sensitized by the 550 nm emission of the UCNPs. The nanoprobes are calibrated by ratiometric dual wavelength readout at 550 nm (reference signal) and 590 nm (sensor signal) and visualized using a scanning confocal fluorescence microscope with 980 nm excitation wavelength. We studied the cellular uptake efficacy of the nanoprobes and determined to which type of compartment, lysosomes, endosomes or cytosol, the probes are targeted to by measuring the pH of their microenvironment. An in situ control was performed in live cells by a treatment with nigericin, whereby the pH of all intracellular compartments is set at extracellular level. Our results suggest that the PEI coating facilitated endosomal escape of the nanoprobes.