Photoluminescence techniques are amongst the most widely used tools in the material and life sciences, with new and exciting applications continuously emerging, due to their many advantages like comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. Drawbacks are , however, signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are time-dependent due to the aging of instrument components, and difficulties to measure absolute fluorescence intensities. Thus, there is a considerable need for standards for intensity, spectral, and temporal fluorescence quantities to meet the increasing need for instrument performance validation and global trends to harmonize physicochemical measurements. In this respect, instrument calibration strategies together with different types of fluorescence standards are presented as well as design concepts for robust, easy-to-use, and format-adaptable fluorescence standards useable for the determination of different fluorescence parameters and a broad variety of fluorescence techniques.
Fluorophore labeled proteins and antibodies, referred to also as targeted optical probes, present a promising strategy for a variety of applications from fundamental cell-based biological studies to in vivo diagnostics and image guided surgeries in humans. In this respect, design strategies for the preparation of such conjugates from different dyes including analyte-responsive fluorophores are presented as well as their analytical and spectroscopic characterization employing Absorption spectroscopy and steady state and time-resolved fluorometry. Special emphasis is dedicated to the influence of dye hydrophilicity and labeling density on the optical properties and binding behavior of these dye-bioconjugates including their performance in in vitro and in vivo bioimaging studies.
Sealing and strengthening of the subsoil by grout injection is a major issue in the field of geotechnical engineering. One commonly applied method is jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty linked with this method is in predicting the resulting column diameter and its material strength. In this paper, we illustrate the application of a newly developed non-destructive quality assurance tool used to determine the diameter of jet grout columns. This approach incorporates standard crosshole and downhole seismic measurements. To demonstrate its effectiveness, we tested the new approach within two-dimensional finite-difference numerical simulations. Additional field tests showed that this tool is also applicable in real site conditions. For this purpose, three jet grout columns were produced with different process parameters in a depth between 3 and 10 m. The evaluated diameters were within 1 and 1.5 m, slightly deviating from the previously predicted range by the jet grouting contractor. Moreover, we were able to detect the base of the columns at a 10-m depth with no significant difficulties. On the other hand, unsaturated, less compacted sands between the groundwater level and surface considerably affected the seismic data, hence complicating the detection of the top of the columns.
Innovative seismic and resistivity tools for determining the diameter of jet grouting columns
(2016)
Jet grouting is used for soil improvement, foundation support and groundwater low control all over the world. It is well accepted and subject of standardization in many countries. However, some issues with the method remain. As the grout columns are produced in the subsurface without visual control in an often inhomogeneous soil, the prediction of the column’s diameter is still a challenge. All methods applied so far have their limitations.
The approach presented in this study is twofold. At Colorado School of Mines a resistivity probe has been developed, which is pushed into the fresh grout directly after production. ERT sections are measured and inverted. Given some background information is available, the diameter of the columns can be evaluated.
At BAM the focus has been on post-production investigations using seismic borehole methods. After hardening of the concrete seismic waves are sent through the column downhole (sensors placed in a casing in the column’s axis, source on top) and crosshole (source and sensor in boreholes on opposite sides of the column). We have developed a scheme to evaluate the diameter of the column based on travel time measurements without calibration. As this method is eventually more time and cost intensive we assume its application mainly for test columns. These are casted and dug out for visual inspection to determine appropriate grouting parameters. Our method would replace the often very cost intensive visual inspection.
Both approaches have been tested at three test columns produced at BAM’s test site at Horstwalde, Germany and on an actual constructions site. Both methods have been in good agreement with the diameters predicted by the jet grouting contractors, which were confirmed in one case by mechanical measurements.
Comparison of fluorescence measurements performed on different fluorescence instruments, analyte quantification from fluorescence intensities as well as the determination of fluorescence quantum yields require instrument calibration and consideration of the wavelength-dependent instrument-specific quantities spectral photon flux reaching the sample and spectral responsivity. Here, we present guidelines and recommendations for the qualification of fluorescence instruments and introduce suitable chromophore-based reference materials. Moreover, the design concepts of the different BAM fluorescence standards are discussed.
Mandatory for the comparison of different emitter classes and the rational design of the next generation of molecular and nanoscale reporters are reliable and quantitative photoluminescence measurements. This is of special relevance for all fluorescence applications in the life and material sciences. In the following, procedures for the determination of this spectroscopic key parameter are presented including pitfalls and achievable uncertainties and material-specific effects related to certain emitter classes are addressed.
The rational synthesis and use of nanomaterials require the characterization of many different properties, ranging from particle size and size distribution over surface chemistry to more applicationrelevant features like optical, electrochemical, and magnetic properties. In the following, several methods for the characterization of functional groups on nanomaterials, like polymer and silica nanoparticles, semiconductor quantum dots, and lanthanide-based upconversion nanocrystals are presented. Additionally, procedures for the measurement of the key spectroscopic performance parameters of nanomaterials with linear and nonlinear photoluminescence, such as the photoluminescence quantum yield, are presented for the UV/vis/NIR/SWIR.
The process of ensuring reliability of NDT applications contains various aspects, such as determining the performance and probability of success, the uncertainty in measurement, the provision of clear and functional procedures and ensuring the correct application accordingly. Test specimens have become powerful elements in supporting many of these aspects. Within the committee for NDT in Civil Engineering (NDT-CE) of the German Society for Nondestructive Testing (DGZfP), the subcommittee on Quality Assurance (UA-QS) therefore addresses the design and the integration of test specimens in the quality assurance process. Depending on the specific purpose, the requirements on test specimens can vary significantly based on the defined simulated scenario. The most prominent purposes of test specimens might be seen in providing references for inspection systems in regard to function control, calibration and validation. Further aspects can be parametric studies, basic investigation of physical principles related to NDT or a simplified and therefore comprehensive demonstration of inspection concepts (e.g. for teaching purposes). The specific purpose of a test specimen dictates the requirements regarding its conception, including the exact design, the material or the fabrication accuracy and the conditioning. In the development of a general guideline by the UA-QS for application-specific procedures and their validation, the use of test specimens is addressed and specific concepts for the design of test specimens are made. This includes the analysis of the measurement process regarding any given application, deriving an adequate calibration approach for it and designing test specimens (calibration specimens) accordingly. Furthermore, it includes the validation of the procedure taking into account all conditions related to the specific application in the field. The validation requires a statistically sufficient number of trials. Thorough evaluation of each trial can only be established if the ground-truth is known. Therefore, test specimens providing a realistic but controlled simulation of the inspection problem are valuable and indispensable elements in the validation process. The requirement of being fully realistic will often not be possible to fulfill due to practical restrictions. Any aspect that cannot be included in the simulation realistically needs to be simulated conservatively. This again, requires a sufficient understanding of the inspection principle and technique to ensure conservativeness. Among other quality-assurance-related aspects, the UA-QS establishes concepts and guidelines regarding sound and efficient approaches for the specific purposes of test specimens. This subcommittee brings together representatives of different Groups along the entire value chain of NDT-CE, including researchers, practitioners, manufacturers and clients. They all work together in establishing a common understanding and level of quality assurance in the industry.
The field of non-destructive testing of civil structures (NDT-CE) has been continuously growing. Due to the complexity and diversity of civil constructions as well as the heterogeneity of concrete, specific standards or guidelines for the application of modern NDT-CE are still missing. The development of individual solutions is the current approach, which is just as challenging as it is common for NDT-CE.
With the increasing development and commercialization of NDT-CE technology, the group of practitioners is growing. To ensure a good level of quality in the industry, it appears necessary to establish adequate means.
Naturally, the performance of NDT-CE methods regarding a specific application is strongly dependent on choosing the most suitable inspection technique and applying it correctly, generally referred to as the inspection procedure in the field of NDT. There are well-defined guidelines regarding procedure documentation and handling in many fields of NDT (e.g. nuclear, aerospace or automotive) according to the high importance of procedures in assuring a successful and reliable application. For a long time, this has not always been the case with NDT-CE, which is still considered a unique discipline of NDT. Part of the reason for that might be the young development state of NDTCE, the heterogeneity of building materials like concrete, timber or masonry as a material and the diversity of civil structures. In consequence, NDT-CE procedure development is considered challenging.
Among other aspects, addressed in the subcommittee on Quality Assurance (UA-QS) within the committee for NDT-CE of the German Society for Nondestructive Testing (DGZfP), part of its work aims at establishing an adequate basis for NDT-CE procedure development. While some of the highly developed approaches from other industries are taken into consideration, they need to be analyzed regarding their suitability for NDT-CE and adapted accordingly. For a procedure to be as defined as possible, it needs to contain sufficient information, such as the scope and limitations regarding material, geometry and condition of the test object, inspection parameters, calibration, data acquisition, analysis criteria as well as requirements regarding the inspection personnel.
For a successful implementation in the field, it is important to define the specific procedure as precisely as possible. Despite the necessity of a great amount of information to be included, the procedure needs to be suitable for efficient field application.
The UA-QS is developing a guideline for NDT-CE procedures suitable for application in this field of NDT to ensure correct and reproducible application. To demonstrate and evaluate this concept, specific examples of procedures are also produced. In particular, the UA-QS has developed a procedure for the detection and positioning of tendon ducts using Ground Penetrating Radar (GPR). This procedure is tested regarding the practical applicability in a roundrobin on a defined type of reference test block.
We present here the design and characterization of a set of spectral calibration beads. These calibration beads are intended for the determination and regular control of the spectral characteristics of fluorescence microscopes and other fluorescence measuring devices for the readout of bead-based assays. This set consists of micrometer-sized polymer beads loaded with dyes from the liquid Calibration Kit Spectral Fluorescence Standards developed and certified by BAM for the wavelength-dependent Determination of the spectral responsivity of fluorescencemeasuring devices like spectrofluorometers. To cover the wavelength Region from 400 to 800 nm, two new near-infrared emissive dyes were included, which were spectroscopically characterized in solution and encapsulated in the beads. The resulting set of beads presents the first step towards a new platform of spectral calibration beads for the determination of the spectral characteristics of fluorescence instruments like fluorescence microscopes, FCM setups, and microtiter plate readers, thereby meeting the increasing demand for reliable and comparable fluorescence data especially in strongly regulated areas, e.g., medical diagnostics. This will eventually provide the basis for standardized calibration procedures for imaging systems as an alternative to microchannel slides containing dye solutions previously reported by us.