Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (10)
- Zeitschriftenartikel (9)
- Beitrag zu einem Tagungsband (7)
- Forschungsdatensatz (3)
- Dissertation (2)
- Sonstiges (2)
Schlagworte
- Nondestructive testing (33) (entfernen)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (27)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (17)
- 8.0 Abteilungsleitung und andere (8)
- 8.4 Akustische und elektromagnetische Verfahren (3)
- 7 Bauwerkssicherheit (2)
- 7.6 Korrosion und Korrosionsschutz (2)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.5 Sicherheit von Gasspeichern (1)
Eingeladener Vortrag
- nein (10)
Geophysical methods have been used in civil engineering for decades. The main field of application is - to no surprise – in geotechnical projects from site characterization to foundation quality assurance. For more than 25 years, ground penetrating radar (GPR) and seismic methods have found applications in structural engineering. Recently introduced geophysical methods have been adopted to ultrasonic investigations in various fields. They help to improve the quality of structural imaging and to detect small changes in concrete. An overview of the history and current use of geophysics in civil engineering is given. Selected examples of new concepts include advances in wave based imaging, quality assurance for foundations, detecting small changes in concrete as well as moisture and corrosion detection are discussed.
Comparison of quantitative defect characterization using pulse-phase and lock-in thermography
(2016)
Using optical excitation sources for active thermography enables a contactless, remote, and non-destructive testing of materials and structures. Currently, two kinds of temporal excitation techniques have been established: pulse or flash excitation, usingmostly flash lamps; and periodic or lock-in excitation, using halogen lamps, LED, or laser arrays. From the experimental point of view, both techniques have their advantages and disadvantages. Concerning the comparison of the testing results of both techniques, only very few studies have been performed in the past. In this contribution, the phase values obtained at flat bottom holes in steel and CFRP and the spatial resolution measured at crossed notches in steel using flash and lock-in excitation are compared quantitatively.
This article focuses on the fusion of flaw indications from multi-sensor nondestructive materials testing. Because each testing method makes use of a different physical principle, a multi-method approach has the potential of effectively differentiating actual defect indications from the many false alarms, thus enhancing detection reliability. In this study, we propose a new technique for aggregating scattered two- or three-dimensional sensory data. Using a density-based approach, the proposed method explicitly addresses localization uncertainties such as registration errors. This feature marks one of the major of advantages of this approach over pixel-based image fusion techniques. We provide guidelines on how to set all the key parameters and demonstrate the technique's robustness. Finally, we apply our fusion approach to experimental data and demonstrate its capability to locate small defects by substantially reducing false alarms under conditions where no single-sensor method is adequate.
Non-Destructive Testing (NDT) is routinely used in aerospace, nuclear, railway and automotive industries. The most common use of NDT is to find flaws in components. In dynamically loaded components, flaws grow, and if they are not detected in time and no corrective measures are taken they can reach critical sizes. When a flaw reaches a critical size, it endangers the structural integrity of the component and will likely cause the component to fail. To detect flaws before they reach a critical size, components are inspected in fixed time intervals with non-destructive testing systems. In order to determine the amount of time between inspections, three variables are necessary: the critical size of the flaw, the flaw propagation speed and the size of the flaw that can be reliably detected by NDT. All three variables are, to a certain extent, stochastic. The critical size of the flaw and flaw propagation speed are questions of fracture mechanics. The size of the flaw that can be reliably detected by NDT is predicted by POD curves. The POD is determined for a given inspection scenario. The inspection scenario includes the NDT system, the component geometry and the type of the flaw. If one of these changes, the POD will also change and needs to be recalculated. As a result, the design of a dynamically loaded safety-relevant components is an iterative process in which a geometry is sought that provides an optimum between structural integrity and inspectability. A model that describes the iterative process for the design of the safe components with examples from praxis will be presented.
Active thermography
(2017)
Active thermography is introduced as tool for diagnostics in civil engineering structures. Aside from basic information, examples for applications of active thermography in different types of structures was presented. Active thermography was applied in historic structures to reveal former components or even ancient openings. Other examples present active thermography as a tool for nondestructive detection of debonding in CFRP strengthened structures. The way is explained, how the system was optimized for different materials.
Contactless temperature sensing is state of the art and essential part of countless applications in the field of process control and automation. This contribution presents the case of a nondestructive thickness measurement method for polymeric coatings on concrete ground. Two pyrometers and a low-cost infrared camera were taken into account. The particular measurement results were compared with those of a more sophisticated infrared camera. It was found that the low-cost infrared camera has a lower noise level than the pyrometers, even for a single pixel. The opportunity to average over a large number of pixels and to establish a bias correction enables a further noise reduction by almost factor of 10.
Furthermore, the temporal resolution of the infrared camera was investigated by means of a well-defined thermal oscillation. It could be demonstrated that the averaged time stamps are correct and the requirement of a Minimum framerate of 50 Hz is met. Finally, the temperature transient on a polymer coated concrete block during and after a 10 s heating period was recorded with a pyrometer and the infrared camera. This experiment confirmed the suitability of the camera for the intended measurement method.
Post-tensioning systems provide safe and efficient construction solutions for long span bridges. Despite the improved grouting practices over the past decade, existing post-tensioning systems may have significant amount of grout defects, which could lead to corrosion of the strands. Condition assessment of post-tensioning systems is necessary to allow bridge owners to take timely, proactive actions to mitigate or prevent further Deterioration and unanticipated tendon failures. A detailed experimental study conducted to assess the performance of nondestructive evaluation techniques in detecting grout defects within internal tendons is presented herein.
Nondestructive evaluation techniques that include Ground Penetrating Radar, Impact Echo, Ultrasonic Tomography, and Ultrasonic Echo are evaluated in terms of detecting the location and severity of fabricated grout defects in a full-scale post-tensioned U-girder mock-up specimen. While Ground Penetrating Radar can identify the location and profile of the internal tendons, particularly metal ducts due to strong reflections, this method did not provide any information about the defect conditions within the tendon. Both Impact Echo and Ultrasonic Echo techniques are effective in identifying the Location of grout defects, but could not differentiate between water, void, or compromised grout conditions. The study clearly demonstrates the need for NDE techniques that are applicable to anchorage regions, and that are capable of estimating the severity and nature of grout defects in internal tendons.
Austenitic stainless steel welds as well as dissimilar metal welds with nickel alloy filler material, used in safety relevant parts of nuclear power plants, still challenge the ultrasonic inspection. The weld material forms large oriented grains which lead on the one hand to high sound scattering and on the other hand – to inhomogeneity and to the acoustic anisotropy of the weld structure. The ultrasonic wave fronts propagate not linearly, as in ferritic weld joints, but along the curves, which depend on the specific grain structure of the weld. Due the influence of these phenomena, it is difficult to analyze the inspection results and to classify the ultrasonic indications, which could be both from the weld geometry and from the material defects. A correct flaw sizing is not possible.
In an ongoing research project, different techniques to improve the reliability of ultrasonic testing at these kinds of welds are investigated. In a first step (in the previous research project) two ultrasonic inspection techniques were developed and validated on plane test specimens with artificial and realistic flaws. In the ongoing project, these techniques are applied to circumferential pipe welds with longitudinal and transverse flaws.
The technique developed at the Federal Institute for Materials Research and Testing (BAM) in Germany uses a combination of ray tracing and synthetic aperture focusing technique (SAFT). To investigate the unknown grain structure, the velocity distribution of weld-transmitting ultrasound waves is measured and used to model the weld by ray tracing.
The second technique, developed at the Fraunhofer Institute for Nondestructive Testing (IZFP) in Germany, uses Sampling Phased Array (Full Matrix Capture) combined with the reverse phase matching (RPM) and the gradient elastic constant descent algorithm (GECDM). This inspection method is able to estimate the elastic constants of the columnar grains in the weld and offers an improvement of the reliability of ultrasonic testing through the correction of the sound field distortion. The unknown inhomogeneity and anisotropy are investigated using a reference indication and the special optimization algorithm.
Both reconstruction techniques give quantitative inspection results and allow the defect sizing. They have been compared to conventional ultrasonic testing with techniques, which are state of the art for components in nuclear power plants. The improvement will be quantified by the comparison of the probability of detection (POD) of each technique.
Validation of artificial defects for non-destructive testing measurements on a reference structure
(2018)
Non-destructive testing was established over the last decades as an important tool for assessing damages, material characterization and quality assurance in civil engineering. For example, Ground Penetrating Radar (GPR) can be used to scan large areas of concrete structures to determine the spatial position of the reinforcement. With the ultrasonic echo method, the thickness of concrete structures can be easily determined even if a high density of reinforcement is given. Various methods and processes have been developed for the validation of NDT procedures aiming at ensuring the quality of measurements in practical use. The Probability of Detection (POD) for example, is an available method to compare different technical devices with each other quantitatively regarding their performance. With this method, the best suited testing device for a specific inspection task under defined boundary conditions can be selected. By using the Guide to the Expression of Uncertainty in Measurement (GUM), it is possible to quantify the measurement uncertainty of an inspection procedure for a specific task. Another important aspect to improve the acceptance of Non-destructive testing methods is the development of reference specimens.
Reference specimens serve for the calibration and further development of NDT methods under realistic conditions in different laboratories under the same conditions. A particular challenge here is the most realistic representation of a damage that can occur at building sites. Possible damages include for example horizontal and vertical cracks or honeycombs in concrete. Such a reference structure was built for the development of a new design of power plant constructions. Comparative studies on the manufacturing of realistic honeycombs and delaminations were carried out in advance on a test specimen. The results of this study are presented here.