Analytische Chemie
Filtern
Dokumenttyp
- Zeitschriftenartikel (3)
- Vortrag (2)
- Posterpräsentation (2)
- Beitrag zu einem Sammelband (1)
- Sonstiges (1)
Sprache
- Englisch (9)
Schlagworte
- Method development (9) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (7)
- 1.2 Biophotonik (3)
- 1.1 Anorganische Spurenanalytik (2)
- 1.8 Umweltanalytik (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 4 Material und Umwelt (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 6 Materialchemie (1)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
- 7 Bauwerkssicherheit (1)
Eingeladener Vortrag
- nein (2)
The project addresses chemical and topographical metrology at surfaces. The new methodologies of measurements at surfaces will be developed as good practice guides and new work item proposals for industrial ISO standards. The objectives of the Joint research project (JRP) are to provide measurement standards and methods with traceability wherever it is practicable to do so for quantitative surface chemical analysis for industrial applications.
Comparing Nontargeted LC-MS Methods by Co-visualizing Linear Dynamic Range and Chemical Coverage
(2019)
INTRODUCTION
Biological and environmental samples contain thousands of small molecule species that all vary in chemical properties and concentration range. Identifying and quantifying all these chemical entities remains a long-term goal in metabolomics and related systems approaches. Due to its broad selectivity, nontargeted LC-MS is usually the method of choice for broad chemical screening. Optimizing nontargeted LC-MS methods, however, is less straightforward than for targeted methods where sensitivity, specificity, linearity etc. serve as well-established performance criteria. We therefore investigated linear dynamic range (LDR) and chemical classification as alternative performance criteria to guide nontargeted method development.
EXPERIMENTAL METHODS
LDR was defined as the linear portion of a feature’s response curve over multiple concentration levels. Comparing the LDR of features across methods can be expected to be significantly more robust than comparing signal intensities for a single concentration. To determine LDR for all features, a computational workflow was implemented in the R programming language. For estimating the linear portion of a curve, several mathematical approaches including linear, non-linear and piecewise linear regression were evaluated. Chemical classification was based on ClassyFire, which computes chemical classes for a given structure. To avoid false classifications for incorrectly annotated compounds, we took the following statistical approach. For each compound, multiple likely annotation hypotheses were derived using a recently described workflow[2]. All annotation hypotheses were submitted to ClassyFire and obtained classifications were ranked by frequency. The most frequently suggested class was kept for further analysis. Finally, LDR and chemical classes were visualized together on a molecular network, which was constructed using the well-established MS/MS similarity approach.
RESULTS AND DISCUSSION
For technical validation of the workflow, several hundred curve fits obtained from the different regression models were reviewed visually. Piecewise linear regression performed the most reliably with respect to the heterogeneous curve shapes of ‘real-life’ features. Validation of chemical classification was performed against a compound library, which showed that 90% of ~450 library compounds were correctly classified using the described approach. Two liquid chromatography methods (HILIC, RPC) as well as two electrospray ionization variants (low/high-temperature ESI) applied to urinary metabolomics were exemplarily studied to test the workflow. Molecular network visualization indicated that of all analytical setups, HILIC/high temperature ESI performed best in terms of high LDR achieved over a wide range of compound classes. Despite one order of magnitude lower sensitivity, HILIC/low temperature ESI showed similar chemical coverage, except for organic nitrogen compounds that were underrepresented compared to high-temperature ESI. Both RPC setups were inferior to the HILIC setups in terms of high-LDR features, supporting previous findings for the given matrix. The higher relative representation of benzenoids and lipids in RPC demonstrated that the workflow successfully captured expected selectivity differences between chromatographies.
CONCLUSION
When comparing nontargeted LC-MS methods for optimization purposes, ideally all available quantitative and qualitative information should be integrated. The present workflow follows this idea. Visualizing LDR and chemical classes of all features on a molecular network quickly indicated differences in method selectivity that were otherwise difficult to spot. As an automated approach, it is easily applied to repeated optimization steps, enabling effective optimization strategies.
Tricalcium aluminate (C3A) is found with less than 10% wt. of the total composition; however, during hydration, C3A plays an important role in the early hydration of cement in the presence of gypsum as a set retarder.
The aim of this investigation is to assess the suitability of optical spectroscopy and a dye-based optical probe to monitor early hydration of C3A in the presence of gypsum and hemihydrate. Optical evaluation was performed using steady-state fluorescence and diffuses reflectance spectroscopy (UV-VisDR). Phase characterization during hydration was done with in-situ X-ray diffraction. UV-VisDR with a cyanine dye probe was used to monitor the formation of metastable phases and was employed together with fluorescence spectroscopy, to follow the Aggregation and disaggregation of the dye during hydration. In conclusion, for the first time, a cyanine dye was identified as a feasible and stable probe to monitor C3A hydration changes in the presence of calcium sulfate.
Research of division Biophotonics at the Federal Institute for Materials Research and Testing (BAM) covers several topics including photophysics of molecular and nanocrystalline emitters, the development of signal enhancement, multiplexing, and barcoding strategies, surface group quantification, the rational design of different types of stimuli-responsive optical probes, and concepts and reference materials for the validation of optical-spectroscopic measurements. In the following representative examples for each of these topics are given. Also, current developments like single particle spectroscopy and flow cytometry with lifetime detection and newly certified fluorescence quantum yield standards are presented.
Conclusions and perspectives
(2020)
This chapter briefly summarizes the methods selected within this book for the characterization of nanoparticles with regard to commonly accessible properties: nanoparticle size and size distribution, shape, surface area, surface charge, aggregation state, structure, chemical composition, surface chemistry, and nanoparticle number concentration. Current progress of measurement and analysis, as far as possible according to standard operation procedures, has been the focus of this work. A number of new and less commonly used methods have not been covered, and we outline some of these in this chapter. Future challenges such as automated measurement and analysis, read-across approaches for the prediction of properties, knowledge of measurement uncertainties, the need for certified reference materials, and the necessity to complement measurements methods to obtain more reliable results are covered, and the unmet measurement requirements for real-world nanoparticles are described.
Towards Unbiased Evaluation of Ionization Performance in LC-HRMS Metabolomics Method Development
(2022)
As metabolomics increasingly finds its way from basic science into applied and regulatory environments, analytical demands on nontargeted mass spectrometric detection methods continue to rise. In addition to improved chemical comprehensiveness, current developments aim at enhanced robustness and repeatability to allow long-term, inter-study, and meta-analyses. Comprehensive metabolomics relies on electrospray ionization (ESI) as the most versatile ionization technique, and recent liquid chromatography-high resolution mass spectrometry (LC-HRMS) instrumentation continues to overcome technical limitations that have hindered the adoption of ESI for applications in the past. Still, developing and standardizing nontargeted ESI methods and instrumental setups remains costly in terms of time and required chemicals, as large panels of metabolite standards are needed to reflect biochemical diversity. In this paper, we investigated in how far a nontargeted pilot experiment, consisting only of a few measurements of a test sample dilution series and comprehensive statistical analysis, can replace conventional targeted evaluation procedures. To examine this potential, two instrumental ESI ion source setups were compared, reflecting a common scenario in practical method development. Two types of feature evaluations were performed, (a) summary statistics solely involving feature intensity values, and (b) analyses additionally including chemical interpretation.
Results were compared in detail to a targeted evaluation of a large metabolite standard panel. We reflect on the advantages and shortcomings of both strategies in the context of current harmonization initiatives in the metabolomics field.
Deciphering microbiological influenced corrosion processes on steel with single cell-ICP-ToF-MS
(2022)
Microbiologically influenced corrosion (MIC) is a highly unpredictable process dictated by the environment, microorganisms, and the respective electron source. Interaction pathways between cells and the metal surface remain unclear. The development of this novel single cell-inductively coupled plasma-time of flight-mass spectrometry analytical method and a MIC-specific staining procedure facilitate the investigation of steel-MIC interactions. With this it is possible to analyze the multi-elemental fingerprint of individual cells. The detection method revealed elemental selectivity for the corrosive methanogenic archaeal strain Methanobacterium-affiliated IM1. The interface between material and environmental analysis thus receives special attention, e.g., when considering MIC on solid steel. Hence, the possible uptake of individual elements from different steel samples is investigated. Results showed the cells responded at a single-cell level to the different types of supplemented elements and displayed the abilities to interact with chromium, vanadium, titanium, cobalt, and molybdenum from solid metal surfaces. The information obtained will be used in the future to elucidate underlying mechanisms and develop possible material protection concepts, thus combining modern methods of analytical sciences with materials research.
References.
Inductively coupled plasma-time of flight-mass spectrometry (ICP-ToF-MS) enables the analysis of the multi-element fingerprint of individual cells due to a (quasi-)simultaneous detection of about 70 elements of the periodic table. The interface between material and environmental analysis thus receives special attention, e.g., when considering corrosion processes. Microbiologically influenced corrosion (MIC) is a highly unpredictable phenomenon due to the influence of the environment, microbial communities involved and the respective electron source. However, the interaction pathway between cells and the metal surface remains unclear. The development of the MIC-specific ICP-ToF-MS analytical method presented here, in combination with the investigation of steel-MIC interactions, contributes significantly to progress in instrumental MIC analysis and will enable clarification of the processes taking place. For this, a MIC-specific staining procedure was developed which ensures the analysis of intact cells. It allows the studies of archaea at a single cell level which is extremely scarce compared to other well characterized organisms. Additionally, the single cell ICP-ToF-MS is used for the analysis of archaea involved in MIC of steel. Hence, the possible uptake of individual elements from different steel samples is investigated - the information obtained will be used in the future to elucidate underlying mechanisms and develop possible material protection concepts, thus combining modern methods of analytical sciences with materials research.
The frequency-domain (FD) method provides an alternative to the commonly used time-domain (TD) approach in characterizing the luminescence kinetics of luminophores, with its own strengths, e.g., the capability to decouple multiple lifetime components with higher reliability and accuracy. While extensively explored for characterizing luminophores with down-shifted emission, this method has not been investigated for studying nonlinear luminescent materials such as lanthanide-doped upconversion nanoparticles (UCNPs), featuring more complicated kinetics. In this work, employing a simplified rate-equation model representing a standard two-photon energy-transfer upconversion process, we thoroughly analyzed the response of the luminescence of UCNPs in the FD method. We found that the FD method can potentially obtain from a single experiment the effective decay rates of three critical energy states of the sensitizer/activator ions involved in the upconversion process. The validity of the FD method is demonstrated by experimental data, agreeing reasonably well with the results obtained by TD methods.