Analytische Chemie
Filtern
Dokumenttyp
- Zeitschriftenartikel (2)
- Vortrag (1)
Sprache
- Englisch (3)
Schlagworte
- Lateral flow assay (3) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
Antibody-gated indicator delivery (gAID) systems based on mesoporous silica nano- and microparticle scaffolds are a promising class of materials for the sensitive chemical detection of small-molecule analytes in simple test formats such as lateral flow assays (LFAs) or microfluidic chips. Their architecture is reminiscent of drug delivery systems, only that reporter molecules instead of drugs are stored in the voids of a porous host particle. In addition, the pores are closed with macromolecular “caps” through a tailored “gatekeeping” recognition chemistry so that the caps are opened when an analyte has reacted with a “gatekeeper”. The subsequent uncapping leads to a release of a large number of indicator molecules, endowing the system with signal amplification features. Particular benefits of such systems are their modularity and adaptability. With the example of the immunochemical detection of type-I pyrethroids by fluorescent dye-releasing gAID systems, the influence of several tuning modes on the optimisation of such hybrid sensory materials is introduced here. In particular, different mesoporous silica supports (from nano- and microparticles to platelets and short fibres), different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in the absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material's pore opening, the better the closing/opening mechanism can be controlled. Because such materials are well-suited for LFAs, performance assessment included a test-strip format besides conventional assays in suspension. In combination with dyes as indicators and smartphones for read-out, simple analytical tests for use by untrained personnel directly at a point-of-need such as an aeroplane cabin can be devised, allowing for sensitivities down to the μg kg−1 range in <5 min with case-required selectivities.
Type-I pyrethroids are frequently used for disinfection purposes on airplanes from and to tropical areas. The WHO (Word Health Organization) defines “disinfection” as the procedure whereby health measures are taken to control or kill the insect vectors of human diseases including dengue, yellow fever and malaria.1 Due to this, a new effective and rapid method for pyrethroids analysis directly in the plane is needed.
To detect type-I pyrethroids, gated materials are constructed for the purpose of finely tuning the movement of a cargo from voids of a mesoporous inorganic support to a solution, in response to a predefined stimulus.2 Antibodies are bound to specific functional groups grafted on the support’s surface with the two-fold aim of closing the mesopores and working as biological receptors for the target compounds.2 A specific opening mechanism, activated selectively in presence of pyrethroids as analytes, is able to control the release of an indicator dye previously loaded inside the inorganic support. As only few molecules of pyrethroids are necessary to open a pore and release a large amount of dyes, the system shows an intrinsic signal amplification quantified as a fluorescence emission intensity.3
Different mesoporous silica supports (from nano- and microparticles to platelets and short fibers) were synthetized, characterized and functionalized following different capping strategies. In this contribution, we will compare the temporal response behaviour of the optimized gated materials to verify if the respective delivery systems are properly closed and how fast they can be opened in presence of the analytes. Our results indicate that the trends of the kinetics observed in solution show a better control of the closing/opening mechanism when the epitope region of the antibody (around 10 nm) properly fits the pore size of the carriers.
Because the incorporation of an antibody-gated dye-delivery system with a conventional test-strip-based lateral-flow assay allows for the detection of analytes down to the ppb level in an easy-to-operate manner and an overall assay time of 2–5 min, which is fast for a biochemical test,3 we carried out first model studies for a lateral flow test assay on membranes, using a smartphone setup for read-out.
The use of gamma-hydroxybutyric acid (GHB) in drug-facilitated sexual assault has increased due to its availability and high solubility in aqueous solutions and alcoholic beverages, necessitating the development of rapid methods for GHB detection. In this respect, portable testing methods for use in the field, based on lateral flow assays (LFAs) and capable of detecting trace concentrations of target analytes, are particularly attractive and hold enormous potential for the detection of illicit drugs. Using this strategy, here we report a rapid, low cost, easy-to-handle strip-based LFA for GHB analysis employing a smartphone for fluorescence readout. At molecular signalling level, the ensemble is based on a Cu2+ complex with a tetradentate ligand and the fluorescent dye coumarin 343, which indicate GHB through an indicator displacement assay (IDA) in aqueous solution. When incorporated in a LFA-based strip test this system shows a detection limit as low as 0.03 μM for GHB in MES buffer solution and is able to detect GHB at concentrations of 0.1 μM in soft drinks and alcoholic beverages in only 1 min.