Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (25)
- Zeitschriftenartikel (12)
- Posterpräsentation (9)
- Buchkapitel (1)
Sprache
- Englisch (47)
Schlagworte
- Laser induced plasma (47) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (25)
Only a few years after the invention of the laser, the concept of laser microprobe mass spectrometry (LMMS), a technique which employed intense laser radiation for ion generation, was introduced. In these early studies at excessive irradiation microplasma formation could be observed to be an effective channel for ion formation. However, this plasma generation in vacuum led to undesired distortions of the mass analyzers and, thus, was discarded as an analytical ion source.
Under ambient conditions, the surrounding air effectively cools the plasma cloud, making the plasma more controllable. The resulting laser induced plasma is nowadays commonly used in laser induced breakdown spectroscopy (LIBS) applications as excitation source for optical emission spectroscopy experiments. However, little effort has been made to introduce a LIBS plasma as a promising ion source for ambient mass spectrometry. The main hindrance is the transient character of laser induced plasmas that typically only has a lifetime on the order of several microseconds. This drastically reduces the duty cycle of these plasma sources. After these microseconds, the generated ions recombinate to uncharged
atoms and even newly bound molecules, making them inaccessible to mass-to-charge analyzers. The advent of high repetition lasers together with the ever growing knowledge about manipulation of charged species at atmospheric pressures allow overcoming these obstacles. This presentation will introduce an ionization scheme using a laser induced plasma as the primary ion source. We believe that this novel ionization strategy will pave the way for future applications in ambient mass spectrometry.
Tomography of a laser-induced plasma in air is performed by inverse Radon transform of angle-resolved plasma images. Plasmas were induced by single laser pulses (SP), double pulses (DP) in collinear geometry, and by a combination of single laser pulses with pulsed arc discharges (SP-AD). Images of plasmas on metallurgical steel slags were taken at delay times suitable for calibration-free laser-induced breakdown spectroscopy (CFLIBS). Delays ranged from few microseconds for SP and DP up to tens of microseconds for SP-AD excitation. The white-light and the spectrally resolved emissivity ε(x,y,z) was reconstructed for the three plasma excitation schemes. The electron number density Ne(x,y,z) and plasma temperature Te(x,y,z) were determined from Mg and Mn emission lines in reconstructed spectra employing the Saha-Boltzmann plot method. The SP plasma revealed strongly inhomogeneous emissivity and plasma temperature. Re-excitation of plasma by a second laser pulse (DP) and by an arc discharge (SP-AD) homogenized the plasma and reduced the spatial variation of ε and Te. The homogenization of a plasma is a promising approach to increase the accuracy of calibration-free LIBS analysis of complex materials.
Two topics will be addressed: (1) calibration-free LIBS based on Monte Carlo spectral optimization and (2) insight into the possibility of simultaneous elemental and molecular analysis by LIBS. Both topics heavily rely on modeling of laser induced plasma and are closely connected to experiment. In Monte Carlo LIBS (MC LIBS), concentrations are found by fitting model-generated synthetic spectra to experimental spectra. The model of a static uniform isothermal plasma in local thermodynamic equilibrium is employed. Many configurations of plasma parameters and their corresponding spectra are simultaneously generated using a graphic processing unit (GPU). Using the GPU allows for the reduction of computational time down to several minutes for one experimental spectrum that presents the significant progress in comparison with earlier versions of MC LIBS. The method is tested by analyzing industrial oxides containing various concentrations of CaO, Fe2O3, MgO, and TiO2. The agreement within several percent between found and certified concentrations is achieved. Next, a newly developed collisional-dominated model of a laser induced plasma is introduced. The model includes the coupled Navier-Stokes, state, radiative transfer, and material transport equations and incorporates plasma chemistry through the equilibrium approach based on the use of atomic and molecular partition functions. Simple chemical systems are modeled including ablation of Si and C in N2 and Ar atmospheres.The model is used to study evolution of number densities of atomic and molecular species in the expanding plasma plume. The distribution is compared to experimental observations obtained by optical imaging and tomography. To further verify the model, dynamic plasma
Recently, a novel ionization scheme for ambient MS has been introduced. It is based on a quasi-continuous laser induced plasma (LIP), ignited in front of the MS inlet. This setup comprises the advantages of an ambient probe, electro neutrality, a sufficient duty cycle, a ubiquitous plasma medium, low power consumption, the absence of solvents and high sensitivity. To assess its future applicability for the detection of volatile organic compounds, plasma properties and operating conditions are investigated to understand the processes, that lead to the unexpected formation of intact molecular ions. Comprehensive studies include optical Emission spectroscopy, shadowgraphic shockwave visualization and time-of-flight mass spectrometry.
Kinetic model of stimulated emission created by resonance pumping of aluminum laser-induced plasma
(2017)
Stimulated emission observed experimentally in an aluminum laser induced plasma is modeled via a kinetic approach. The simulated emission at several cascade transitions is created by a pump laser guided through the plasma at several microseconds after its creation and tuned in resonance with the strong 3s²3p-3s²4s transition at 266 nm. A two-dimensional space-time collisional radiative plasma model explains the creation of the Population inversion and lasing at wavelengths of 2100 nm and 396.1 nm. The population inversion for lasing at 2100 nm is created by depopulation of the ground 3s²3p state and population of the 3s²5s state via the absorption of the resonant radiation at 266 nm. The population inversion for lasing at 396.1 nm occurs during the laser pulse via the decay of the population of the pumped 3s²5s state to the excited 3s²4s state via cascade transitions driven optically and by collisions. In particular, efficient are the mixing transitions between neighboring states separated by small gaps on the order of kT at Plasma temperatures of 5000–10 000 K. The model predicts that the population inversion and corresponding gain may reach high values even at very moderate pump energy of several lJ per pulse. The efficiency of lasing at 2100 nm and 396.1 nm is estimated to be ~3% and 0.05%, correspondingly with respect to the pump laser intensity. The gain for lasing at 396.1 nm can reach as high as ~40 cm⁻¹.
The polarization effect that the pump radiation at 266 nm imposes on the stimulated emission at 396.1 nm is discussed. The calculated results are favorably compared to experimental data.
An airborne laser plasma is suggested as an ambient ion source for mass spectrometry. Its fundamental physical properties, such as an excellent spatial and temporal definition, high electron and ion densities and a high effective cross section in maintaining the plasma, make it a promising candidate for future applications. For deeper insights into the plasma properties, the optical plasma emission is examined and compared to mass spectra. The results show a seemingly contradictory behavior, since the emitted light reports the plasma to almost entirely consist of hot elemental ions, while the corresponding mass spectra exhibit the formation of intact molecular species. Further experiments, including time- resolved shadowgraphy, spatially resolved mass spectrometry, as well as flow-dependent emission spectroscopy and mass spectrometry, suggest the analyte molecules to be formed in the cold plasma vicinity upon interaction with reactive species formed inside the hot plasma center. Spatial separation is maintained by concentrically expanding pressure waves, inducing a strong unidirectional diffusion. The accompanying rarefaction inside the plasma center can be compensated by a gas stream application. This replenishing results in a strong increase in emission brightness, in local reactive species concentration, and eventually in direct mass spectrometric sensitivity. To determine the analytical performance of the new technique, a comparison with an atmospheric pressure chemical ionization (APCI) source was conducted. Two kitchen herbs, namely, spearmint and basil, were analyzed without any sample pretreatment. The presented results demonstrate a considerably higher sensitivity of the presented laser-spark ionization technique.