Today X-ray tomography and Ultrasound Synthetic Aperture Focusing Techniques are representative examples for defect imaging in the field of nondestructive testing. THz time domain spectroscopy (TDS) operates with short electromagnetic pulses. The sensitivity of the pulses to optical material property changes makes THz-TDS attractive for the detection of flaws in dielectric materials. Unfortunately, the X-ray computed tomography (CT) model holds only for THz-TDS reconstruction if minor refraction index differences between the inhomogeneities and the surrounding material matrix exist. A Time Domain SAFT algorithm has been developed to overcome the restrictions. THz time domain measurement on representative sample sets with inherent artefacts were performed to use them for the Image reconstructions. The results will be presented and compared with optical surface images of the used test objects to evaluate the SAFT algorithm in relation to the econstruction quality.
THz applications for NDT
(2017)
Electromagnetic waves in the frequency range between 0.1 and 10 THz are described as THz-radiation (T-ray). The ability to penetrate dielectric materials, to operate contactless and to be non-ionizing as well as be-ing insensitive to ambient temperatures makes THz technologies for NDT applications attractive especially where other techniques are not available or less suitable. Today T-rays are applied in non-destructive testing for quality control and condition monitoring issues. The operation is based on the combination of both transmission and/or reflection measurements and specially developed reconstruction procedures. Firstly, THz-TDS measurements will be presented to demonstrate the opportunities for spectroscopy and imaging of polymer materials. A SAFT algorithm and an Optical Layer-Model will be presented and discussed in more detail to demonstrate the opportunities of image reconstruction for visualization of the inner structures of op-tically and far infra-red opaque polymer composites.
Up to now THz-TDS-systems aren’t considered to be nondestructive testing facilities for large scale industrial applications, despite it was proven that they provide a comprehensive set of quality parameters. A practical approach to bring THz-TDS in addition to already existing testing systems into the industrial mainstream is systematic development of future test procedures and test facilities for dielectrics. For this purpose polyeth-ylene test specimen with introduced artefacts were designed, to evaluate the detection sensitivity of Time of Flight measurements based on dielectrics. SAFT reconstructed tomograms are presented which visualize the sizes and location of artificially introduced flaws.
X-ray imaging methods are used in many fields of research, as they allow a non-destructive Investigation of the elemental content of various samples. As for every imaging method, for X-ray imaging the optics are of crucial importance. However, these optics can be very expensive and laborious to build, as the requirements on surface roughness and precision are extremely high. Angles of reflection and refraction are often in the range of a few mrad, making a compact design hard to achieve. In this work we present a possibility to simplify X-ray imaging. We have adapted the coded aperture method, a high energy radiation imaging method that has its origins in astrophysics, to full field X-ray fluorescence imaging. In coded aperture imaging, an object is projected through a known mask, the coded aperture, onto an area sensitive detector. The resulting image consists of overlapping projections of the object and a reconstruction step is necessary to obtain the information from the recorded image. We recorded fluorescence images of different samples with an energy-dispersive 2D detector (pnCCD) and investigated different reconstruction methods. With a small coded aperture with 12 holes we could significantly increase the count rate compared to measurements with a straight polycapillary optic. We show that the reconstruction of two different samples is possible with a deconvolution approach, an iterative algorithm and a neural network. These results demonstrate that X-ray fluorescence imaging with coded apertures has the potential to deliver good results without scanning and with an improved count rate, so that measurement times can be shortened compared to established methods.
Thermographic reconstruction of defects that lie in the bulk of a sample is a difficult task because entropy production during heat diffusion leads to information loss. To reconstruct defects one has to solve an inverse heat conduction problem. The quality of the reconstruction is closely related to the information content of the observed data set that is reflected by the decreasing ability to spatially resolve a defect with growing defect depth. In this work we show a 2D reconstruction of rectangular slots with different width-to-depth ratios in a metallic sample. For this purpose, we apply the virtual wave concept and incorporate positivity and sparsity as prior information to overcome the diffusion-based information loss partially. The reconstruction is based on simulated and experimental pulse thermography data. In the first reconstruction step, we compute a virtual wave field from the surface temperature data. This allows us, in the second step, to use ultrasonic backpropagation methods for image reconstruction.