Nondestructive testing (NDT) methods are applicable in many ways for defect detection as well as optimization of packaging production processes. The visual inspection method is the technique which is mostly used, although neither the customer nor a skilled inspector may be aware of this.
Techniques like ultrasound for wall thickness measurement, the application of x-ray techniques or the use of dye penetrant techniques for crack detection are rather well known to the NDT family. However, acoustic emission techniques can also be helpful for the characterization of packaging materials. In this paper the employment of x-ray computer tomography (CT) for measurement of wall thickness in plastic jerrycans, especially on the edges, and its possible optimization of production processes will be discussed.
A comparison of the CT and ultrasonic examinations of wall thickness and the reliability of this measured data are also important points for the discussion, especially if some safety factors can be derived from the results.
The leakage test is also good for jerrycans, IBCs or other kinds of drums for the transportation and storage of dangerous goods. The disadvantage of this kind of test is that a lack of quality, e.g. wall thickness deterioration, cannot be detected if the wall thickness withstands the internal pressure. Therefore, especially for Quality assurance, the other, previously mentioned techniques are better for a statistical assessment of a batch. This paper is focused on the comparison of different NDT results with special emphasis on the large range of material mechanical properties.
Applications of X-ray refraction to non-destructive characterization of ceramics and composites
(2013)
X-ray refraction is analogous to visible light deflection by matter, with two main differences: 1- convex objects cause divergence (i.e., the refraction index n is smaller than 1), and 2- deflection angles are very small, from a few seconds to a few minutes of arc (i.e., n is near to 1). Trivially but importantly, deflection of X-rays is also sensitive to the orientation of the object boundaries. These features make X-ray refraction techniques extremely suitable to a) detect defects such as pores and microcracks, and quantify their densities in bulk (light) materials, and b) evaluate porosity and particle properties such as orientation, size, and spatial distribution (by mapping). While X-ray refraction techniques cannot in general image single defects, their detectability is simply limited by the wavelength of the radiation.
We will thereby show the application of X-ray refraction 2D mapping (topography) and tomography to different sorts of problems in ceramic science and technology: 1) Sintering of SiC green bodies; 2) Porosity analysis in diesel particulate filter silicates; 3) fiber de-bonding in metal and polymer matrix composites; 4) micro-cracking of glass-precursor -eucryptite. We will see that the use of X-ray refraction analysis yields quantitative results, also directly usable in available models.
In this paper we present the results of imaging studies of ancient Egyptian metallic artifacts using micro-Computed Tomography (micro-CT). Micro-CT is a non-destructive imaging method with high spatial resolution, which enables the examination of the internal structure of objects. It is thus especially suitable for the investigation of cultural heritage and archaeological findings, when it is not possible to sample or difficult to manipulate the object. Using specialized software for 3D visualization and segmentation, data sets of two objects were analyzed. We gained a clear view of the inner structure of a metallic archaeological artifact from the necropolis of Abusir el-Meleq, which is believed to be very ancient in the Egyptian archaeological context (from the Predynastic Era), and were able to distinguish its different omponents under the thick layers of external concretions. These components give hints about the production technology of the object. We also investigated the contents of a closed metal box found near Abusir dated to the Late/Greco-Roman Period. The identified Content corresponds either to sediments or to mineral remains of the original content of the box. Both artifacts are from excavations conducted in Egypt and are part of the archeological collection of the Ägyptisches Museum und Papyrussammlung in Berlin.
Since the advent of industrial computed tomography (CT), this new analysis method has been used also for the investigation of objects of cultural heritage and art. CT provides the possibility to determine the inner and outer surfaces and to investigate the material structure without causing damage to the valuable objects.
In this talk I will present examples of measurements performed at BAM, which demonstrate what CT can do for objects of diverse materials and for different objectives.
Ein kurzes Blick in die Computertomographie (CT) im Rahmen des RT3 Kurs der DGZfP ist gegeben.
Die Radontransformation ist bildlich erklärt, und die Grundlagen der Technik mit Vergleich zu der Radiographie sind auch erwähnt. Die typische Rekonstruktionsfehler und deren Beseitigung sind behandelt. Am Ende Beispiele der Anwendungen der CT sind gegeben, aus der zerstörungsfreie Prüfung, der Materialwissenschaft und der Metrologie.
Numerical measurement uncertainty determination for dimensional measurements of microparts with CT
(2016)
Up to now, the only standardized method to determine the measurement uncertainty for computed tomography (CT) is to use calibrated workpieces as specified in the Guideline VDI/VDE 2630 Part 2.1. This paper discusses a promising numerical method for uncertainty determination with help of a virtual metrological CT (VMCT). It gives an explanation of the adjustments, the input parameters and the execution of the simulation. Furthermore, it discusses the first results of uncertainty determination compared to the method of using calibrated workpieces with the aid of two example cases.
Ein kurzes Blick in die Computertomographie (CT) im Rahmen des RT3 Kurs der DGZfP ist gegeben.
Die Radontransformation ist bildlich erklärt, und die Grundlagen der Technik mit Vergleich zu der Radiographie sind auch erwähnt. Die typische Rekonstruktionsfehler und deren Beseitigung sind behandelt. Am Ende Beispiele der Anwendungen der CT sind gegeben, aus der zerstörungsfreie Prüfung, der Materialwissenschaft und der Metrologie.
Mit Hilfe der Computertomographie können zerstörungsfrei Bilder des Bodengefüges gewonnen werden. Sowohl die verschiedene Dichte des Bodens als auch Hohlräume und Poren sowie Wurzeln und anderes organisches Material können dargestellt werden. Die Wurzeln werden dabei lagerichtig wiedergegeben. Begrenzt wird dieses durch die Ortsauflösung des jeweiligen Tomogramms.
Ist die Methode für eine Fragestellung aus der landwirtschaftlichen Praxis – Einfluss der Bodenbearbeitung auf das Wurzelbild von Raps – geeignet?