The intention of this compilation of articles was to introduce brand-new developments in the field of chemical imaging which have not been discussed in previous review articles. These include the design of new sensor nanomaterials based on photon uponversion crystals which convert near-infrared excitation light into sensor signals in the visible wavelength range highlighted by Christ and Schäferling. Sun, Ungerböck and Mayr describe the state of the art in oxygen imaging in microreactors and microfluidic devices. Miniaturized sensors for the imaging of oxygen, pH and temperature in microchips, microfluidic platforms and microbioreactors are reviewed by Pfeiffer and Nagl. Furthermore, Dmitriev and Papkovsky present a critical assessment of the applicability of probes for intracellular oxygen sensing.
I hope these articles provide an interesting insight into advanced luminescent sensor materials and the applications of optical micro- and nanosensors in fluorescence imaging today and will be inspiring for the reader. Finally, I would like to thank all authors and referees for spending their time to enable this collection of articles.
Molecularly imprinted polymers (MIPs) are potent and established recognition phases in separation and enrichment applications. Because of their robustness, versatility and format adaptability, they also constitute very promising sensing phases, especially when the active sensing element is directly integrated into the MIP. Fluorescent MIPs incorporating fluorescent monomers are perhaps the best developed and most successful approach here. This article reviews the state of the art in this field, discussing the pros and cons of the use of fluorescent dye and probe derivatives as such monomers, the different molecular interaction forces for template complexation, signalling modes and a variety of related approaches that have been realized over the years, including Förster resonance energy transfer processes, covalent imprinting, postmodification attachment of fluorescent units and conjugated polymers as MIPs; other measurement schemes and sensing chemistries that use MIPs and fluorescence interrogation to solve analytical problems (fluorescent competitive assays, fluorescent analytes, etc.) are not covered here. Throughout the article, photophysical processes are discussed to facilitate understanding of the effects that can occur when one is planning for a fluorescence response to happen in a constrained polymer matrix. The article concludes with a concise assessment of the suitability of the different formats for sensor realization.
Trace humidity was measured by using miniaturized planar coulometric sensors in technical gases such as hydrogen, nitrogen, helium, nitrous oxide, and synthetic air. Frost point temperatures tf in the gases ranged from −60 °C to −30 °C, which is equivalent to a vapour mole fraction xv from 10 μmol mol−1 to 376 μmol mol−1. In addition, the generated humidity was determined by using a precision dew point hygrometer as reference. Nonlinear calibration functions were calculated that correlated electric current (sensor signal) and reference humidity. Parameters of functions were tested with one-way analysis of variances (ANOVA) to prove if all used sensors had a similar behavior in the same gas during experiments. Results of ANOVA confirmed that averaged functions can be applied for trace humidity measurement in nitrogen, helium, nitrous oxide, and synthetic air. The calculated functions were negligibly different for nitrogen, helium, and synthetic air. In humidified nitrous oxide, a minor change of parameters was observed due to lower electrical currents. In total contrast to that, the measured sensor signals were significantly higher in humidified hydrogen and each sensor required its own calibration function. The reason was a recombination effect that favoured multiple measurements of water molecules. Nevertheless, it was possible to measure continuously trace humidity in all tested gases by using coulometric sensors with an expanded uncertainty below 2 K (k = 2).