The growing need to implement sensors such as NIR or Raman spectroscopy for the in-situ monitoring of bioprocesses which follows the standards of Quality by Design is either restricted by the impact of the huge water signal or by a disturbing fluorescence background originating from compounds in the culture media. Furthermore, the characterization of the bioprocess samples is challenging due to changing conditions in course of cultivation.
Here we evaluate two different process-suitable Raman spectroscopic approaches, namely time-gated Raman which bears the potential to extract the Raman signal from the fluorescence background, and cw- Raman with NIR excitation in combination with Surface Enhanced Raman Spectroscopy- (SERS) to investigate cell-free supernatants of Escherichia coli sampled over the course of a cultivation. A confocal Raman microscope was used as a reference for the process devices. The concentration of the analytes, glucose, acetate as well as metabolites such as cAMP, AMP and amino-acids were determined by offline by High-Performance Liquid Chromatography (HPLC) to serve as reference for the calibration of the Raman and SERS spectral data.
Multivariate evaluation of the Raman and SERS spectra by Partial Least Squares Regression (PLSR) yielded for most of the analytes robust correlations at each sampling point. Repeated investigation of the off-line samples over a larger experimental period suggested not only a high reliability of the Raman data in general but also a high repeatability of the SERS experiments. Similar spectral features in different quality and signal/noise ratios were measured with all three set-ups. Major results of the comparison of the different Raman spectroscopic approaches and their combination with SERS are summarized and conclusions are drawn on which approach provides the most accurate concentration data among the target analytes.
Acknowledgement
The authors kindly thank Mario Birkholz (IHP, Frankfurt (Oder), Germany) for the opportunity to use a confocal Raman microscope, Alex Bunker and Tapani Viitala (Division of Pharmaceutical Biosciences, Centre for Drug Research, University of Helsinki, Finland).
Spectroscopic methods possess important advantages for the observation of bioprocesses: they are robust, gain many data within a short time scale, and allow for the measurement of multiple relevant information at the same time. Next to Near-infrared spectroscopy, Raman spectroscopy is increasingly applied as a powerful online tool to monitor bioprocesses. However, Raman spectra may be obscured by straylight, cosmic rays and fluorescence. To achieve the best performance, optimal conditions for spectral quality and stability should be pursued. This comprises not only the choice of highly-sensitive equipment, but also the way of implementation into the process. Here we compared the potential of introducing a sterilized fiber optical Raman probe, and a flow-through cell into the bypass of a stirred tank reactor to monitor an autotrophic cultivation of Ralstonia eutropha where gasses are the energy and carbon sources. Raman spectra were continuously recorded over seven days and 22 samples were taken for the reference analytics of biomass, optical density, and protein. In addition, data for of phosphate and ammonium were available. The quantitative Evaluation of Raman spectra by Partial Least Squares Regression (PLSR) yielded comparable results for both approaches, however, there was a general trend of lower prediction errors with the immersion probe.
The better performance of the non-contact optic may be either related to a more representative interaction of the measurement optics with the probe or simply to the absence of probe-fouling, which was observed with the immersion optic in the interstice between window and metal frame.