Analytische Chemie
Filtern
Dokumenttyp
Sprache
- Englisch (3)
Schlagworte
- Laser Doppler vibrometer (3) (entfernen)
Organisationseinheit der BAM
AbstractAir‐coupled ultrasonic testing (ACU) is a pioneering technique in non‐destructive testing (NDT). While contact testing and fluid immersion testing are standard methods in many applications, the adoption of ACU is progressing slowly, especially in the low ultrasonic frequency range. A main reason for this development is the difficulty of generating high amplitude ultrasonic bursts with equipment that is robust enough to be applied outside a laboratory environment. This paper presents the fluidic ultrasonic transducer as a solution to this challenge. This novel aeroacoustic source uses the flow instability of a sonic jet in a bistable fluidic switch to generate ultrasonic bursts up to 60 kHz with a mean peak pressure of 320 Pa. The robust design allows operation in adverse environments, independent of the operating fluid. Non‐contact through‐transmission experiments are conducted on four materials and compared with the results of conventional transducers. For the first time, it is shown that the novel fluidic ultrasonic transducer provides a suitable acoustic signal for NDT tasks and has potential of furthering the implementation of ACU in industrial applications.This article is protected by copyright. All rights reserved
This paper presents an automatic damage imaging technique by employing a signal processing approach based on applying hierarchically clustered filters across different domains. The technique involves time-frequency-wavenumber filter banks which are applied sequentially to ultrasonic guided wave (UGW) data. The study is conducted for a single lap joint composite specimen with a special focus on small voids which were formed due to manual adhesive component mixing. UGW data are acquired with a 3D Scanning Laser Doppler Vibrometer (LDV) over the scan area of the bonded plate. UGWs are excited at the central frequency of 100 kHz by a single piezoelectric transducer mounted on the surface of the single plate. Within each domain of time, frequency, and wavenumber, four filters are designed which results in 64 distinct filtered wavefields. From each filtered wavefield, an image is obtained by using root-mean-square (RMS) calculation of the signals. The obtained results are then combined to create a final, improved-resolution image of the scan area. The final image is compared to the image obtained through RMS calculation of full wavefield with interpolation through Delaunay triangulation and the image obtained by X-ray radiography. The results show that the smallest void that could be detected has a diameter of 2.14 mm.
Development of an Accurate and Robust Air-Coupled Ultrasonic Time-of-Flight Measurement Technique
(2022)
Ultrasonic time-of-flight (ToF) measurements enable the non-destructive characterization of material parameters as well as the reconstruction of scatterers inside a specimen. The time-consuming and potentially damaging procedure of applying a liquid couplant between specimen and transducer can be avoided by using air-coupled ultrasound. However, to obtain accurate ToF results, the waveform and travel time of the acoustic signal through the air, which are influenced by the ambient conditions, need to be considered. The placement of microphones as signal receivers is restricted to locations where they do not affect the sound field. This study presents a novel method for in-air ranging and ToF determination that is non-invasive and robust to changing ambient conditions or waveform variations. The in-air travel time was determined by utilizing the azimuthal directivity of a laser Doppler vibrometer operated in refracto-vibrometry (RV) mode. The time of entry of the acoustic signal was determined using the autocorrelation of the RV signal. The same signal was further used as a reference for determining the ToF through the specimen in transmission mode via cross-correlation. The derived signal processing procedure was verified in experiments on a polyamide specimen. Here, a ranging accuracy of <0.1 mm and a transmission ToF accuracy of 0.3μs were achieved. Thus, the proposed method enables fast and accurate non-invasive ToF measurements that do not require knowledge about transducer characteristics or ambient conditions.