Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (2213) (entfernen)
Sprache
- Englisch (1681)
- Deutsch (514)
- Mehrsprachig (8)
- Spanisch (5)
- Französisch (3)
- Russisch (2)
Referierte Publikation
- nein (2213) (entfernen)
Schlagworte
- Fluorescence (65)
- Nanoparticles (65)
- Concrete (64)
- LIBS (62)
- Synchrotron (48)
- NDT (47)
- Zerstörungsfreie Prüfung (46)
- Ultrasound (39)
- XRF (39)
- Nanoparticle (38)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (531)
- 1 Analytische Chemie; Referenzmaterialien (498)
- 6 Materialchemie (404)
- 8.0 Abteilungsleitung und andere (148)
- 6.1 Oberflächen- und Dünnschichtanalyse (137)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (126)
- 1.4 Prozessanalytik (122)
- 8.4 Akustische und elektromagnetische Verfahren (115)
- 1.1 Anorganische Spurenanalytik (113)
- 6.3 Strukturanalytik (98)
Der Vortrag stellt die Arbeiten der BAM in der Initiative QI-Digital vor, in deren Rahmen Lösungen für eine moderne und digitale Qualitätsinfrastruktur entwickelt werden. Schwerpunkt liegt auf dem zentralen Werkzeug Quality-X sowie dem Pilotprojekt "Moderne Qualitätssicherung in der Additiven Fertigung".
Defects are still common in metal components built with Additive Manufacturing (AM). Process monitoring methods for laser powder bed fusion (PBF-LB/M) are used in industry, but relationships between monitoring data and defect formation are not fully understood yet. Additionally, defects and deformations may develop with a time delay to the laser energy input. Thus, currently, the component quality is only determinable after the finished process.
Here, active laser thermography, a non-destructive testing method, is adapted to PBF-LB/M, using the defocused process laser as heat source. The testing can be performed layer by layer throughout the manufacturing process. The results of the defect detection using infrared cameras are presented for a custom research PBF-LB/M machine. Our work enables a shift from post-process testing of components towards in-situ testing during the AM process. The actual component quality is evaluated in the process chamber and defects can be detected between layers.
The presentation provides an overview and introduction to the need and drivers for the digital transformation of the quality infrastructure (QI). It illustrates the tools and processes that are the fundation of a digital QI and how the initiatve QI-Digital aims at developing accordant solutions. Special emphasis is given to the pilot projects at BAM.
Current decontamination strategies of PFAS-burdened soils mainly consist of adsorption methods using adsorbents for fixation of PFAS in the ground. A second option is the utilization of a “pump and treat” process, cycling polluted soils through a washing plant leading to the concentration of the pollutants in the fine fraction. Only a subsequent, high-energy consuming pyrolysis process guarantees the total destruction of all fluorinated organic contaminants. These approaches are cost-intensive and not intended for the direct decomposition of all PFAS contaminants. Hence, there is a great demand for innovative developments and chemical treatment technologies, dealing with new strategies of tackling the PFAS problem. Thus, we investigated mechanochemical treatment of PFAS contaminated soils with various additives in a ball mill and analyzed the PFAS defluorination with gas chromatography mass spectrometry (GC-MS) and liquid chromatography tandem mass spectrometry (LC-MS/MS), respectively, as well as the fluoride mineralization by ion chromatography (IC) and fluorine K-edge X-ray absorption near-edge structure (XANES) spectroscopy.
The focus of the presentation focus will be on 3D imaging by means of X-ray Computed Tomography (XCT) at the lab and at synchrotron, and the non-destructive residual stress (RS) characterization by diffraction of additively manufactured (AM) materials in BAM (Berlin, Germany). The manufacturing defects and high RS are inherent of AM techniques and affect structural integrity of the components. Using XCT the defects size and shape distribution as well as geometrical deviations can be characterized, allowing the further optimization of the manufacturing process. Diffraction-based RS analysis methods using neutron and synchrotron X-rays at large scale facilities offer the possibility to non-destructively spatially resolve both surface and bulk RS in complex components and track their changes following applied thermal or mechanical loads.
In recent years, additive manufacturing technologies have gained in importance. Laser powder bed fusion can be used for complex functional components or the production of workpieces in small quantities. High safety requirements, e.g. in aerospace, demand comprehensive quality control. Therefore, non-destructive offline inspection methods such as computed tomography are used after production. Recently, online non-destructive testing methods such as optical tomography have been developed to improve profitability and practicality. In this presentation, the applicability of eddy current inspection using GMR sensors for online inspection of PBF-LB/M parts is demonstrated. Eddy current testing is performed for each layer during the production process at frequencies uo to 1.2 MHz. Despite the use of high-resolution arrays with 128 elements, the testing time is kept low by an adapted hardware. Thus, the measurement can be performed during the manufacturing process without significantly slowing down the production process. In addition to the approach, the results of an online eddy current test of a step-shaped test specimen made of Haynes282 are presented.
In recent years, the demand for reliable, versatile, fluorescent pH and oxygen sensors has increased rapidly in many biomedical applications since these analytes are important indicators of cell function or certain diseases. Therefore, sensor particles are needed that are small enough to penetrate cells, non-toxic, and allow for close-up optical monitoring. When developing such sensor systems, one must consider the pH and oxygen range detectable by the sensor dye and the matrix material of the used carrier particles. Here, we present the development of pH- and oxygen-responsive polymeric beads functionalized with fluorescent dyad molecules that consist of an analyte-responsive fluorophore and an analyte-inert dye.
Optical pH sensors utilizing colorimetric or fluorescent indicator dyes are highly promising in many biomedical and life science applications where electrochemical sensors fail. For instance, optical sensors are not prone to electrical interferences, they are noninvasive and enable remote measurements. Moreover, fluorescence detection is very fast, highly sensitive, and provides several readout parameters ideal for multiplexing with nanometer resolution using simple, inexpensive, and miniaturizable instrumentation. Here, we present the design of a dyad sensor molecule, consisting of an analyte-responsive and an analyte inert reference fluorophore.