9.6 Additive Fertigung metallischer Komponenten
Filtern
Dokumenttyp
- Vortrag (78)
- Zeitschriftenartikel (38)
- Beitrag zu einem Tagungsband (32)
- Posterpräsentation (13)
- Forschungsdatensatz (3)
Sprache
- Englisch (126)
- Deutsch (37)
- Mehrsprachig (1)
Schlagworte
- Additive manufacturing (33)
- Additive Manufacturing (26)
- Laser powder bed fusion (25)
- Additive Fertigung (16)
- Thermography (12)
- Laser Powder Bed Fusion (10)
- Heat accumulation (8)
- Laser beam welding (8)
- AISI 316L (7)
- Electromagnetic forces (7)
Organisationseinheit der BAM
- 9 Komponentensicherheit (164)
- 9.6 Additive Fertigung metallischer Komponenten (164)
- 8 Zerstörungsfreie Prüfung (58)
- 8.5 Röntgenbildgebung (31)
- 5 Werkstofftechnik (26)
- 8.0 Abteilungsleitung und andere (24)
- 9.4 Integrität von Schweißverbindungen (22)
- 5.2 Metallische Hochtemperaturwerkstoffe (19)
- 5.1 Mikrostruktur Design und Degradation (17)
- 2 Prozess- und Anlagensicherheit (14)
Acoustic emission testing
(2018)
The monitoring of oil and gas pipelines by means of distributed fibre optic sensors is becoming common. The most recent development in the field of fibre optic sensing is the distributed acoustic sensing (DAS), which allows to detect and to localize third party threats to pipelines. For this purpose, fibre optic telecommunication cables located close to the pipelines are usually used. However, DAS carries a far greater potential for continuous condition monitoring of pipelines.
The interdisciplinary research project AGIFAMOR (Ageing Infrastructures – Fibre Optic Monitoring of Pipes) at BAM investigates a new technical approach to extend the application field of DAS towards the detection and localization of acoustic signals that indicate critical alterations and certain damage scenarios originated from within the pipeline or the pipe wall. Therefore, the optical fibre sensors are applied onto the pipe itself and the application procedure towards an optimal acoustic signal transduction is optimized.
A number of laboratory scale experiments were performed focusing on the signal transmission of acoustic signals as well as the detection of damages in the pipe wall by means of DAS. Furthermore, real-scale tests on a pipeline DN100 of 38m length have been carried out at the BAM test site for technical safety (BAM-TTS) to study the detection and localization of leaks and of changing flow profiles due to corrosion or sedimentation processes.
The monitoring of oil and gas pipelines by means of distributed fibre optic sensors is becoming common. The most recent development in the field of fibre optic sensing is the distributed acoustic sensing (DAS), which allows to detect and to localize third party threats to pipelines. For this purpose, fibre optic telecommunication cables located close to the pipelines are usually used. However, DAS carries a far greater potential for continuous condition monitoring of pipelines.
The interdisciplinary research project AGIFAMOR (Ageing Infrastructures – Fibre Optic Monitoring of Pipes) at BAM investigates a new technical approach to extend the application field of DAS towards the detection and localization of acoustic signals that indicate critical alterations and certain damage scenarios originated from within the pipeline or the pipe wall. Therefore, the optical fibre sensors are applied onto the pipe itself and the application procedure towards an optimal acoustic signal transduction is optimized.
A number of laboratory scale experiments were performed focusing on the signal transmission of acoustic signals as well as the detection of damage in the pipe wall by means of DAS. Furthermore, real-scale tests on a pipeline DN100 of 38 m length have been carried out at the BAM test site for technical safety (BAM-TTS) to study the detection and localization of leaks and of changing flow profiles due to corrosion or sedimentation processes.
Schäden an Rohrleitungen können zu hohen Umweltbelastungen und wirtschaftlichen Schäden führen. Um die dauerhafte Verfügbarkeit der Infrastruktur zu gewährleisten, wird im Rahmen des Projekts AGIFAMOR an der Bundesanstalt für Materialforschung und -prüfung (BAM) erprobt, inwiefern das Verfahren der verteilten akustischen faseroptischen Sensorik (Distributed acoustic sensing – DAS) zur kontinuierlichen Überwachung von Rohrleitungen eingesetzt werden kann. Neben der DAS werden erprobte Verfahren der zerstörungsfreien Prüfung wie Schallemissionsanalyse (SEA) und Beschleunigungssensoren eingesetzt. An dieser Stelle soll detailliert auf die Hauptschadensursachen an Rohrleitungen, den Versuchsstand zur mechanischen Belastung von Rohren sowie die Möglichkeiten zu Untersuchungen im Realmaßstab eingegangen werden.