Forschungsdatensätze der BAM
Filtern
Dokumenttyp
- Forschungsdatensatz (15)
Sprache
- Englisch (15)
Referierte Publikation
- nein (15)
Schlagworte
- SAXS (15) (entfernen)
Organisationseinheit der BAM
- 6 Materialchemie (15) (entfernen)
SASfit 0.94.12
(2023)
Small-angle scattering is an increasingly common method for characterizing particle ensembles in a wide variety of sample types and for diverse areas of application. SASfit has been one of the most comprehensive and flexible curve-fitting programs for decades, with many specialized tools for various fields.
## Summary:
This notebook and associated datasets (including VASP details) accompany a manuscript available on the ArXiv (https://doi.org/10.48550/arXiv.2303.13435) and hopefully soon in a journal as short communication as well. Most of the details needed to understand this notebook are explained in that paper with the same title as above. For convenience, the abstract is repeated here:
## Paper abstract:
We demonstrate a strategy for simulating wide-range X-ray scattering patterns, which spans the small- and wide scattering angles as well as the scattering angles typically used for Pair Distribution Function (PDF) analysis. Such simulated patterns can be used to test holistic analysis models, and, since the diffraction intensity is presented coupled to the scattering intensity, may offer a novel pathway for determining the degree of crystallinity.
The ``Ultima Ratio'' strategy is demonstrated on a 64-nm Metal Organic Framework (MOF) particle, calculated from $Q<0.01$\,$\mathrm{nm}^{-1}$ up to $Q\approx150$\,$\mathrm{nm}^{-1}$, with a resolution of 0.16\,\AA. The computations exploit a modified 3D Fast Fourier Transform (3D-FFT), whose modifications enable the transformations of matrices at least up to $8000^3$ voxels in size. Multiple of these modified 3D-FFTs are combined to improve the low-$Q$ behaviour.
The resulting curve is compared to a wide-range scattering pattern measured on a polydisperse MOF powder.
While computationally intensive, the approach is expected to be useful for simulating scattering from a wide range of realistic, complex structures, from (poly-)crystalline particles to hierarchical, multicomponent structures such as viruses and catalysts.
X-ray scattering datasets for samples described in the 2022 publication "Side chain length dependent dynamics and conductivity in self assembled ion channels". This dataset includes both raw and processed X-ray scattering data for samples ILC8, ILC10, ILC12, ILC14 and ILC16 alongside background measurement files (BKG).
X-ray scattering datasets for samples described in the 2022 publication "Molecular Mobility of Polynorbornenes with Trimethylsiloxysilyl side groups: Influence of the Polymerization Mechanism". This dataset includes both raw and processed X-ray scattering data for samples APTCN and MPTCN, alongside background measurements files (BKG).
X-ray scattering datasets for samples described in the 2020 publication "Molecular Dynamics of Janus Polynorbornenes: Glass Transitions and Nanophase Separation". This dataset includes both raw and processed X-ray scattering data for samples PTCHSiO-Pr, Bu, Hx, Oc and De, alongside background measurements files (BKG). This data was collected using the MOUSE project (instrument and methodology).
X-ray scattering and sorption data associated with the publication "Antiaromatic Covalent Organic Frameworks Based on Dibenzopentalenes". X-ray scattering data is provided for COF and POP materials, including data from stability tests, as three-column ascii files with columns q (nm-1), I (m-1) and uncertainty on I, as well as being provided in 2θ.
This dataset contains the processed and analysed small-angle X-ray scattering data associated with all samples from the publications "Bio-SAXS of Single-Stranded DNA-Binding Proteins: Radiation Protection by the Compatible Solute Ectoine" (https://doi.org/10.1039/D2CP05053F).
Files associated with McSAS3 analyses are included, alongside the relevant SAXS data, with datasets labelled in accordance to the protein (G5P), its concentration (1, 2 or 4 mg/mL), and if Ectoine is present (Ect) or absent (Pure). PEPSIsaxs simulations of the GVP monomer (PDB structure: 1GV5 ) and dimer are also included.
TOPAS-bioSAXS-dosimetry extension for TOPAS-nBio based particle scattering simulations can be obtained from https://github.com/MarcBHahn/TOPAS-bioSAXS-dosimetry which is further described in https://doi.org/10.26272/opus4-55751.
This work was funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under grant number 442240902 (HA 8528/2-1 and SE 2999/2-1). We acknowledge Diamond Light Source for time on Beamline B21 under Proposal SM29806. This work has been supported by iNEXT-Discovery, grant number 871037, funded by the Horizon 2020 program of the European Commission.
These are four datasets that were made available to the participants of the Small-angle Scattering data analysis round robin. The intent was to find out how comparable results from different researchers are, who analyse exactly the same processed, corrected dataset.
In this repository, there are:
1) a PDF document with more details for the study,
2) the datasets for people to try and fit
3) an Excel spreadsheet to document the results.
Datasets 1 and 2 were modified from: Deumer, Jerome, & Gollwitzer, Christian. (2022). npSize_SAXS_data_PTB (Version 5) [Data set]. Zenodo. https://doi.org/10.5281/zenodo.5886834
Datasets 3 and 4 were collected in-house on the MOUSE instrument.
Technical drawings and documents for building a compact, heated, vacuum compatible flow-through sample holder. This holder is in use at the BAM MOUSE instrument as well as at the I22 beamline at the Diamond Light Source (see references for instrument details).
This holder has several features:
- The holder can be used in vacuum environments as well as in atmosphere
- It has two G 1/4" UNF fittings to attach HPLC tubing for (optionally) flowing a medium through the sample cell
- There are two additional (unflowed) sample positions for backgrounds and calibrants, held at the same temperature
- The low-mass design coupled with a 250W heating element can achieve heating rates of 1 degree C per second, when coupled (for example) with an Omron E5CC PID controller.
- The sample holder insert can be made from various materials depending on the application. Sealing the sample from the vacuum can be achieved using kapton, teflon or Magic tape, depending on the temperature requirements. The inlet and outlet holes will need to be punctured with a needle to enable flow.
- Large exit cones ensure a clear exit angle of at least 45 degrees two theta.
- It has been tested with temperatures up to 400 degrees C.
- Compression area has been raised and polished to ensure a good vacuum seal.
OpenSCAD, STL and technical drawings for the solid sample rack designed primarily for use with The MOUSE instruments.
This solid sample rack can be used in conjunction with:
- Laser-cut sample holder (10.5281/zenodo.7499437)
- Modular sample holder (10.5281/zenodo.7499416)
- Capillary flow-cell for liquid samples (10.5281/zenodo.7499421)