8.0 Abteilungsleitung und andere
Filtern
Dokumenttyp
- Posterpräsentation (62) (entfernen)
Referierte Publikation
- nein (62) (entfernen)
Schlagworte
- Thermography (13)
- NMR (7)
- Super resolution (6)
- Additive manufacturing (5)
- Feuchte (5)
- Laser thermography (5)
- NDT (5)
- Human Factors (4)
- Joint sparsity (4)
- LIBS (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (62)
- 8.0 Abteilungsleitung und andere (62)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (9)
- 9 Komponentensicherheit (9)
- 9.3 Schweißtechnische Fertigungsverfahren (9)
- 8.5 Röntgenbildgebung (4)
- 1 Analytische Chemie; Referenzmaterialien (3)
- 1.9 Chemische und optische Sensorik (3)
- 4 Material und Umwelt (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
Thermographic non-destructive testing is based on the interaction of thermal waves with inhomogeneities. The propagation of thermal waves from the heat source to the inhomogeneity and to the detection surface according to the thermal diffusion equation leads to the fact that two closely spaced defects can be incorrectly detected as one defect in the measured thermogram. In order to break this spatial resolution limit (super resolution), the combination of spatially structured heating and numerical methods of compressed sensing can be used. The improvement of the spatial resolution for defect detection then depends in the classical sense directly on the number of measurements. Current practical implementations of this super resolution detection still suffer from long measurement times, since not only the achievable resolution depends on performing multiple measurements, but due to the use of single spot laser sources or laser arrays with low pixel count, also the scanning process itself is quite slow. With the application of most recent high-power digital micromirror device (DMD) based laser projector technology this issue can now be overcome.
Im Rahmen des EMPIR-Projektes NanoXSpot (Nanometre X-Ray Focal Spot Measurement) werden rückführbare Messverfahren zur Bestimmung der Brennfleckgröße und -form von Röntgenröhren mit Submikrometerauflösung (100 nm – 20 µm) entwickelt, die die Grundlage für die Erarbeitung eines Standardentwurfes bilden. Der Standardentwurf wird bei CEN TC 138 (Non-destructive testing) WG 1 (Radiographic testing) eingereicht und mit ISO und ASTM harmonisiert. Zur Untersuchung der entwickelten Methoden (Brennfleck-CT, Fit-Prozedur für Strichgruppenkörper) und des im Projekt NanoXSpot neu entworfenen Testkörpers, NxS, wurde ein Ringversuch durchgeführt. Dabei wurde sowohl der angestrebte Überlappungsbereich mit EN 12543 Teil 5 (Messung der effektiven Brennfleckgröße von Mini- und Mikrofokus-Röntgenröhren) und ASTM E 2903 (Standard Test Method for Measurement of the Effective Focal Spot Size of Mini and Micro Focus X-ray Tubes) für Brennflecke >5 µm als auch Brennflecke <5 µm untersucht. Im Mittelpunkt standen dabei Stabilität und Wiederholbarkeit der entwickelten Methoden zur Bestimmung der Brennfleckgröße. In diesem Beitrag werden die Ergebnisse des durchgeführten Ringversuches vorgestellt und diskutiert, um Schlussfolgerungen und Empfehlungen für die Vorbereitung eines erweiterten Ringversuchs mit Partnern und Stakeholdern abzuleiten.
Mit dem zerstörungsfreien Verfahren der nuklear magnetischen Resonanz (NMR) mit Fokus auf 1H-Protonen lässt sich der Feuchtegehalt in porösen Materialien bestimmen und bei einem vollgesättigten Medium eine Porengrößenverteilung ableiten. Für die Ermittlung der Porengrößenverteilung muss die gemessene T2-Relaxationszeitenverteilung mit dem Parameter Oberflächenrelaxivität (OR) umgerechnet werden. Ist dieser Parameter für das zu untersuchende Medium unbekannt, kann dieser mithilfe von Vergleichsverfahren abgeschätzt werden. Dabei kommen z. B. Gassorption, Quecksilberporosimetrie (MIP), Dünnschliff-Mikroskopie oder µ-Computer-Tomographie (µ-CT) zum Einsatz. Da die verschiedenen Verfahren allerdings unterschiedliche Auflösungsgrenzen aufweisen und auf verschiedenen physikalischen Prinzipien beruhen, können die ermittelten ORs für ein Medium stark variieren. Um ein besseres Verständnis für die OR und die Einflüsse der Vergleichsverfahren zu bekommen, wurden 19 verschiedene Sandsteintypen untersucht. Die OR wurde zum einen basierend auf der spezifischen inneren Oberfläche aus der dynamischen Dampfsorption (DVS) und der Gassorption abgeleitet. Zum anderen wurden die Relaxationszeitenverteilungen durch manuelles Anpassen der OR derart in Porengrößenverteilungen umgerechnet, sodass es eine Übereinstimmung mit den Porengrößenverteilungen aus MIP und/oder µ-CT gibt. Die Umrechnung von Relaxationszeitverteilungen in eine Porengrößenverteilung berücksichtigt dabei sowohl fast- als auch slow-diffusion. Insgesamt ergab sich für die Sandsteine ein breites Spektrum an ORs, bei dem die über die innere spezifische Oberfläche ermittelten ORs andere Größenordnungen aufwiesen (< 10 µm/s), als bei dem Vergleich mit MIP oder µ-CT (bis 600 µm/s). Die mit MIP und µ-CT ermittelten Werten lagen dabei um einen Faktor von 1 bis 30 auseinander. Dieser umfangreiche Datensatz, der vier verschiedene Vergleichsverfahren einbezieht, soll neue Erkenntnisse in der Charakterisierung von porösen Materialien (z. B. bezüglich der Oberflächenrauigkeit) und in der Ursache für die starke Variation der OR ermöglichen. Durch das Berücksichtigen von fast- als auch slow-diffusion, können dabei sogar Daten in eine Porengrößenverteilung umgerechnet werden, bei denen das fast-diffusion-Kriterium nach Brownstein und Tarr nicht erfüllt ist. Außerdem ergibt sich aus der Berücksichtigung des slow-diffusion-Regimes ein neues Verständnis für die obere Auflösungsgrenze von NMR.
Häufig stellt sich die Frage, ob eine Materialinhomogenität kritisch für die strukturelle Integrität eines Bauteils ist. Dies ist häufig abhängig von der Größe und der Geometrie dieser Materialinhomogenität. Während die korrekte Bestimmung einer Defektgröße zweifelsfrei eine Messaufgabe darstellt, ist die Detektion eines Materialdefekts die Hauptaufgabe eines Prüfsystems. Allerdings sind manche Defekte zu klein, um detektiert zu werden. Es ist jedoch schwierig, etwas zu bemessen, was nur schwer gefunden werden kann, stellen sowohl die Detektion als auch die Fähigkeit den Defekt zu bemaßen, Teile der der Bewertung eines Prüfsystems dar. Die vorliegende Publikation beschäftigt sich zum einen mit der Notwendigkeit, die Auffindwahrscheinlichkeit von Prüfverfahren zu bewerten, und zum anderen mit den Schritten, mit denen das Konzept der Prüfunsicherheitsbewertung national und international vorangetrieben wird. Final werden die Methoden evaluiert, die den Schulterschluss zwischen Prüf- und Messunsicherheitsbestimmung ermöglichen. Ergänzt wird der Artikel mit Beispielen aus der Industrie, welche die aktuelle Relevanz des Themas untermauern.
The manufacturing of metal parts for the use in safety-relevant applications by Laser Powder Bed Fusion (L-PBF) demands a quality assurance of both part and process. Thermography is a nondestructive testing method that allows the in-situ determination of the thermal history of the produced part which is connected to the mechanical properties and the formation of defects [1]. A wide range of commercial thermographic camera systems working in different spectral ranges is available on the market. The understanding of the applicability of these cameras for qualitative and quantitative in-situ measurements in L-PBF is of vital importance [2]. In this study, the building process of a cylindrical specimen (Inconel 718) is monitored by three camera systems simultaniously. These camera systems are sensitive in various spectral bandwidths providing information in different temperature ranges. The performance of each camera system is explored in the context of the extraction of image features for the detection of defects. It is shown that the high temporal and thermal process dynamics are limiting factors on this matter. The combination of different spectral camera systems promises the potential of an improved defect detection by data fusion.
Environmentally friendly alternatives to cement are created through the synthesis of numerous base materials. The variation of their proportions alone leads to millions of materials candidates. Identifying suitable materials is very laborious; traditional systematic research in the laboratory consumes a lot of time and effort.
Sequential learning (SL) potentially speeds up the materials research process despite limited but highly complex available information. SL does not make direct predictions of material properties but ranks possible experiments according to their utility. The most promising experiments are prioritized over dead-end experiments and experiments whose outcome is already known.
Our work has shown that SL seems to be promising for cement research. So far, research has mainly focused on materials whose synthesis is faster and whose material properties require less time for development or characterization (allowing many successive experiments). Contrarily, in the case of binders, SL is only useful if few experiments lead to the desired goal, as for example, the determination of the compressive strength alone typically requires 28 days.
In research practice, experimental designs and the availability of resources often determine which data can be used - for example, when some laboratory resources are not available or deemed irrelevant to a task. As a result, new research scenarios are constantly emerging, each of which requires to demonstrate SL’s performance.
We are presenting the SLAMD app to facilitate the exploration of SL methods in numerous research scenarios. The app provides flexible and low-threshold access to AI methods via intuitive and interactive user interfaces. We deliberately pursue a software-based research approach (as opposed to code-, or script-based). On the one hand, the results are more comprehensible since we refer to a common (code) basis (’reproducible science’). On the other hand, the methods are easily accessible to all which accelerates the knowledge transfer into laboratory practice.
Seit 1999 existiert das MIL-HDBK 1823, die us-amerikanische Leitfaden zur Erstellung einer Probability of Detection (POD; Fehlerdetektionswahrscheinlichkeit). Obwohl das Dokument als internationaler Stand der Technik angesehen wird, ist die allgemeine Anwendung in der ZfP-Praxis von einigen Nachteilen begleitet:
1. Die beschriebenen POD‘s bilden ausschließlich die Grundlagen-POD ab, jeweils mit nur einem Fehlerparameter und einem Signalparameter. Modernere Ansätze werden hier nicht adressiert.
2. Die aktuelle Version verzichtet fast vollständig auf konkrete mathematische Formulierungen.
3. Die Richtlinie richtet sich hauptsächlich an die militärische Luftfahrt.
4. Das Dokument ist nur in englischer Sprache verfügbar.
Mit Hilfe eines BMWi-Förderprojekts wird ein weiterführendes Regelwerk auf Basis der MIL-HDBK 1823 unter deutscher Federführung erarbeitet, welches die Anwendung der POD-Berechnung auf eine breitere Basis stellt und die oben genannten Nachteile der MIL-HDBK 1823 behebt.
Das vorgestellte Projekt „normPOD“ wird eine normative, branchenübergreifend einsetzbare Beschreibung des Vorgehens bei der Berechnung einer POD zur Zuverlässigkeitsbewertung zerstörungsfreier Prüfungen entwickeln. Hierbei wird Klarheit über unterschiedliche POD-Ansätze geschaffen und anhand praktischer Beispiele aus Maschinenbau und Bauwesen ein Leitfaden für den Praxiseinsatz erarbeitet.
Das Poster gibt einen Überblick über die geplanten Arbeiten innerhalb des Projekts und lädt die Beteiligten der DGZfP-Jahrestagung zur Diskussion ein, um eine breite Basis und Akzeptanz für die entwickelten Berechnungsverfahren zu schaffen, insbesondere in Hinblick auf ZfP 4.0 und Digitalisierung.
A joint project of partners from industry and research institutions for the research and construction of an analysis system for an automated, sensor-supported sorting of construction and demolition waste will be presented. This is intended to supplement or replace the previously practiced manual sorting, which harbors many risks and dangers for the staff and only enables obvious, visually detectable differences for separation. The method of laser-induced breakdown spectroscopy is to be used in combination with hyperspectral sensors. Due to the jointly processed information (data fusion), this should lead to a significant improvement in the separation of types. In addition to the sorting of different materials (concrete, main masonry building materials, organic components, glass, etc.), impurities such as SO3-containing building materials (gypsum, aerated concrete, etc.) could also be detected and separated.
The subsequent recycling and sales opportunities are examined, such as the use of recycled aggregates in concrete, the recycling of building materials containing sulphate as a gypsum substitute for the cement industry or the agglomeration of synthetic lightweight aggregates for lightweight concrete or as a substrate for green roofs. At the same time, it is investigated whether soluble components (sulfates, heavy metals, etc.) can be detected by LIBS without a wet chemical analysis and what impact the recycling materials have on the environment.
The entire value chain is examined using the example of the Berlin location in order to minimize economic / technological barriers and obstacles on a cluster level and to sustainably increase the recovery and recycling rates.
Die thermografische ZfP basiert auf der Wechselwirkung von thermischen Wellen mit Inhomogenitäten. Die Ausbreitung von thermischen Wellen von der Wärmequelle zur Inhomogenität und zur Detektionsoberfläche entsprechend der thermischen Diffusionsgleichung führt dazu, dass zwei eng beieinander liegende Defekte fälschlicherweise als ein Defekt im gemessenen Thermogramm erkannt werden können. Um diese räumliche Auflösungsgrenze zu durchbrechen, also eine Super Resolution zu realisieren, kann die Kombination von räumlich strukturierter Erwärmung und numerischen Verfahren des Compressed Sensings verwendet werden.
Für unsere Arbeiten benutzen wir Hochleistungs-Laser im Kilowatt-Bereich um die Probe entweder hochaufgelöst entlang einer Linie (1D) abzurastern oder strukturiert zu erwärmen. Die Verbesserung des räumlichen Auflösungsvermögens zur Defekterkennung hängt dann im klassischen Sinne direkt von der Anzahl der Messungen ab. Mithilfe des Compressed Sensings und Vorkenntnissen über das System ist es jedoch möglich die Anzahl der Messungen zu reduzieren und trotzdem Super Resolution zu erzielen. Wie viele Messungen notwendig sind und wie groß der Auflösungsgewinn gegenüber der konventionellen thermografischen Prüfung mit flächiger Erwärmung ist, hängt von einer Reihe von Messparametern, der Messstrategie, Probeneigenschaften und den verwendeten Rekonstruktionsalgorithmen ab.
Unsere Studien befassen sich mit dem Einfluss der experimentellen Parameter, wie z.B. der Pulslänge der Laserbeleuchtung und der Größe des Laserspots. Weiterhin haben wir uns mit der Wahl der Parameter in der Rekonstruktion auseinandergesetzt, die einen Einfluss auf das im Compressed Sensing zugrundeliegende Minimierungsproblem haben. Für jeden getesteten Parametersatz wurde eine Rekonstruktionsqualität berechnet. Schließlich wurden die Defektrekonstruktionen basierend auf den Parameternsätzen verglichen, sodass eine Parameterwahl für hohe Rekonstruktionsqualitäten mit thermografischer Super Resolution empfohlen werden kann.
Im Europäischen EMPIR-Projekt „NanoXSpot“ (Measurement of the focal spot size of Xray tubes with spot sizes down to 100 nm) werden neue Messmethoden für Brennflecke von Röntgenröhren entwickelt. Teil des Projektes ist die Entwicklung eines zur Lochkameramethode äquivalenten Messverfahrens für kleine Brennflecke. ASTM E 1165-20, Annex A, beschreibt die Bestimmung von Brennfleckgrößen aus Kantenprofilen von Lochaufnahmen für Röntgenröhren mit Brennflecken > 50 μm. Es wurde bereits vorgeschlagen über die Analyse der richtungsabhängigen Kantenunschärfe einer Lochblende und anschließender CT-Rekonstruktion die Intensitätsverteilung des Brennflecks äquivalent zur Lochkameraaufnahme zu berechnen. Die Lochkameramethode, wie in EN 12543-2 und ASTM E 1165-20 beschrieben, ist im unteren Größenbereich für Mikrofokusröhren nicht geeignet, da Pinholes < 10 μm schwer zu fertigen sind und lange Belichtungszeiten erwartet werden. Mit Hilfe exakt gefertigter Lochblenden sowie strukturierter Targets mit konvergierenden Strukturen wird der Bereich mit der Single-Shot-CT-Methode auf die Messung von Mikrofokusröhren, alternativ zur Vermessung von Kanten oder Strichgruppenkörpern, erweitert. Die rekonstruierten Brennfleckformen werden mit Kanten und Lochkameraaufnahmen quantitativ verglichen, um die Messgenauigkeit zu bewerten. Außerdem werden CNR und Messzeit bestimmt, um die Wirtschaftlichkeit der Verfahren zu bewerten.