The separation of two closely located defects in fields of Thermographic NDE is very challenging. The diffusive nature of thermal waves leads to a fundamental limitation in spatial resolution. Therefore, super resolution image reconstruction can be used. A new concerted ansatz based on spatially structured heating and joint sparsity of the signal ensemble allows an improved reconstruction of closely located defects. This new technique has also been studied using 1D laser arrays in active thermography.
The post-processing can be roughly described by two steps: 1. Finding a sparse basis representation using a reconstruction algorithm such as the Fourier transform, 2. Application of an iterative joint sparsity (IJOSP) method to the firstly reconstructed data. For this reason, different methods in post-processing can be compared using the same measured data set.
The focus in this work was the variation of reconstruction algorithms in step 1 and its influence on the results from step 2. More precise, the measured thermal waves can be transformed to virtual (ultrasound) waves that can be processed by applying ultrasound reconstruction algorithms and finally the super resolution algorithm. Otherwise, it is also possible to make use of a Fourier transform with a subsequent super resolution routine. These super resolution thermographic image reconstruction techniques in post-processing are discussed and evaluated regarding performance, accuracy and repeatability.
Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden.
Responsible treatment of the environment and resources is a key element of sustainability. The building and construction industry is one of the largest consumers of natural resources. Consequently, there is a particular need for regulations and technologies that help to create closed material cycles. From the technological point of view, such efforts are complicated by the growing material diversity and the amount of composites contained in present and future construction and demolition waste (CDW). Nowadays, simple but proven techniques like manual sorting are mainly used. However, this practice not only poses health risks and dangers to the staff performing the work, but also relies on merely obvious, visually striking differences. Automated, sensor-based sorting of these building materials could complement or replace this practice to improve processing speed, recycling rates, sorting quality, and prevailing health conditions. The preliminary results for the identification of a wide variety of building materials with LIBS are presented.
Optical lock-in thermography is a completely contactless and very sensitive NDE technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive, do not need any work safety measures and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Altogether using lasers considerably increases the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in testing [1, 2]. We report on the mentioned benefits of using such high-power lasers and analyze the range of materials to be tested using lock-in thermography in dependence on the laser irradiance, the modulation frequency, the infrared camera as well as the optical and thermal material parameters. In this context, we also address a number of systematic errors caused by the use of ideal and non-ideal heat sources. For example, the measured phase angle in lock-in thermography depends on the irradiance and the modulation bandwidth of the source. This in turn has a decisive influence on the uncertainty in the quantification of, e.g. layer thicknesses.
Additive manufacturing (AM) offers a range of novel applications. However, the manufacturing process is complex and the production of defect-free parts with a high reliability is still a challenge. Thermography is a valuable tool for process surveillance, especially in metal AM processes. The high process temperatures allow one to use cameras usually operating in the visible spectral range. Here, we compare the results of first measurements during the manufacturing process of a commercial laser metal deposition (LMD) setup using a MWIR camera with those from a VIS high-speed camera with band pass filter in the NIR range.
BAM ensures and represents high standards for safety in technology and chemistry. Additive manufacturing (AM) changes the requirements for conventional non-destructive testing (NDT) as new processes of defect creation occur. Especially in safety critical areas, such as aerospace and automotive, new manufacturing processes and materials always require reliability tests and new standards which is a big challenge for NDT.
As a part of ProMoAM project, we are optimizing a prototype X-ray backscatter to reach NDT requirements, and thereafter to apply it for process monitoring. Moreover, we studied the capability of a radiography approach to detect artificial defects in AM components made by laser powder bed fusion (L-PBF).
19th and 20th centuries glass paint layers consist of a colour body and a colourless lead silicate flux, in which borax or boric acid was added as further component to improve the paint ability and to reduce the firing temperature for multiple layers of paint. Model glasses were used in laboratory tests to investigate the stability of glass paints with additions of boron oxide. To determine boron in paint layers, a LIBS-system with pulsed NdYAG-laser was used.
Seit 1999 existiert das MIL-HDBK 1823, die us-amerikanische Leitfaden zur Erstellung einer Probability of Detection (POD; Fehlerdetektionswahrscheinlichkeit). Obwohl das Dokument als internationaler Stand der Technik angesehen wird, ist die allgemeine Anwendung in der ZfP-Praxis von einigen Nachteilen begleitet:
1. Die beschriebenen POD‘s bilden ausschließlich die Grundlagen-POD ab, jeweils mit nur einem Fehlerparameter und einem Signalparameter. Modernere Ansätze werden hier nicht adressiert.
2. Die aktuelle Version verzichtet fast vollständig auf konkrete mathematische Formulierungen.
3. Die Richtlinie richtet sich hauptsächlich an die militärische Luftfahrt.
4. Das Dokument ist nur in englischer Sprache verfügbar.
Mit Hilfe eines BMWi-Förderprojekts wird ein weiterführendes Regelwerk auf Basis der MIL-HDBK 1823 unter deutscher Federführung erarbeitet, welches die Anwendung der POD-Berechnung auf eine breitere Basis stellt und die oben genannten Nachteile der MIL-HDBK 1823 behebt.
Das vorgestellte Projekt „normPOD“ wird eine normative, branchenübergreifend einsetzbare Beschreibung des Vorgehens bei der Berechnung einer POD zur Zuverlässigkeitsbewertung zerstörungsfreier Prüfungen entwickeln. Hierbei wird Klarheit über unterschiedliche POD-Ansätze geschaffen und anhand praktischer Beispiele aus Maschinenbau und Bauwesen ein Leitfaden für den Praxiseinsatz erarbeitet.
Das Poster gibt einen Überblick über die geplanten Arbeiten innerhalb des Projekts und lädt die Beteiligten der DGZfP-Jahrestagung zur Diskussion ein, um eine breite Basis und Akzeptanz für die entwickelten Berechnungsverfahren zu schaffen, insbesondere in Hinblick auf ZfP 4.0 und Digitalisierung.
EMPIR Project NanoXSpot
(2019)
The overall objective of project NanoXSpot (Nanometre X-ray Focal Spot Measurement) is to develop traceable measurement methods for determining the focal spot size, shape, and position of nanometre resolution X-ray tubes. The impact of the technical results will be ensured by preparing prenormative documents for submission to CEN TC 138 (Non-destructive testing) WG 1 (Radiographic testing), which directly addresses the research needs of CEN, currently revising standards in the series 12543 for focal spot measurements below 5 µm spot size to harmonise standards and measurement method between ASTM and CEN.