Arbeitspapiere der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Sonstiges (48)
Sprache
- Deutsch (30)
- Englisch (17)
- Mehrsprachig (1)
Referierte Publikation
- nein (48)
Schlagworte
- Boden (8)
- Eignungsprüfung (8)
- Gefahrgutunfälle (8)
- MKW (8)
- Unfallstatistik (8)
- Wassergefährdende Stoffe (8)
- Gesamtcyanid (7)
- PAK (7)
- Spurenelemente (7)
- PAH (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 1.5 Proteinanalytik (2)
- 9 Komponentensicherheit (2)
- 9.2 Versuchsanlagen und Prüftechnik (2)
- 9.4 Integrität von Schweißverbindungen (2)
- 1.4 Prozessanalytik (1)
- 1.6 Anorganische Referenzmaterialien (1)
- 1.8 Umweltanalytik (1)
- 6 Materialchemie (1)
- 6.0 Abteilungsleitung und andere (1)
- 7 Bauwerkssicherheit (1)
- 7.2 Ingenieurbau (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- S Qualitätsinfrastruktur (1)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (1)
- VP Vizepräsident (1)
- VP.1 eScience (1)
The impact of magnetism on chemical ordering in face-centered cubic CrCoNi medium entropy alloy is studied by a combination of ab initio simulations, machine learning potentials, and Monte Carlo simulations. Large magnetic energies are revealed for some mixed L12 /L10 type ordered configurations, which are rooted in strong nearest-neighbor magnetic exchange interactions and chemical bonding among the constituent elements. There is a delicate interplay between magnetism and stability of MoPt2 and L12 /L10 type of ordering which may explain opposing experimental and theoretical findings.
Die Verwendung hochfester Feinkornbaustähle hat für viele Anwendungen des Stahlbaus ein großes Potenzial für gewichtsoptimierte, effiziente Strukturen mit ho-her mechanischer Beanspruchbarkeit. Weitere Zugewinne an Effizienz sind durch generative Fertigungsschritte sowie bionische Bauweisen erzielbar. Hierzu stehen bereits kommerzielle hochfeste drahtförmige Zusatzwerkstoffe für formgebendes MSG-Schweißen zur Verfügung. Dem Einsatz stehen noch fehlende quantitative Aussagen zu den fertigungsbedingten Beanspruchungen und der Bauteilsicherheit während Herstellung und Betrieb im Wege. Dies betrifft insbesondere prozess- sowie materialbedingte Einflüsse und die konstruktive Schrumpfbehinderung verbunden mit der Ausbildung hoher Zugeigenspannungen und damit zusammenhängenden Kaltrissbildung.
Hierfür wurden im Projekt detaillierte und anwenderbezogene Kenntnisse zu den komplexen Wechselwirkungen zwischen Schweißprozess und Wärmeführung während der Fertigung, der metallurgischen Vorgänge und insbesondere der vorliegenden konstruktiven Einflüsse auf die entstehenden Eigenspannungen erarbeitet, um ein frühzeitiges Bauteilversagen aufgrund eines hohen fertigungsbedingten Beanspruchungsniveaus bis hin zu einer Rissbildung während der Fertigung sicher zu vermeiden. Gleichzeitig wurden die Einflüsse auf die mechanisch-technologischen Gütewerte systematisch analysiert. Zudem wurden die Auswirkungen trennender Verfahren durch Entfernen der Substratplatte sowie durch die spanende Bearbeitung der Vorformlinge zu Endbauteilgeometrien geklärt, da diese unmittelbar den Eigenspannungszustand beeinflussen und deutlichen Verzug der Bauteile auslösen.
Für das generative Schweißen konnten Verarbeitungsempfehlungen sowie Normenvorgaben erarbeitet werden. Dies hilft insbesondere KMU eine wirtschaftliche, beanspruchungsgerechte und risssichere generative Fertigung von Bauteilen aus hochfesten Feinkornbaustählen zu ermöglichen.
In den Zeiten der Globalisierung und der beschleunigten technologischen Entwicklungen lassen sich in den Industrieländern nur mit einer entsprechenden Innovationsdynamik und -dichte die Herausforderungen im Hinblick auf Wachstum, Beschäftigung und Strukturwandel erfüllen. Grundvoraussetzung hierfür ist eine leistungsfähige Forschung. Um die Forschungsinfrastruktur in der Bundesrepublik zu erhalten und global wettbewerbsfähig zu bleiben, sind verstärkte Investitionen des Staates und der Wirtschaft notwendig. Mit den Investitionen im Rahmen der Hightech-Strategie hat die Bundesregierung einen wichtigen Schritt zur Förderung des wissenschaftlich-technischen Fortschritts in Deutschland getan. Die Investitionen in die Forschungsinfrastruktur des Landes sind nun von den Forschungseinrichtungen und Universitäten effektiv und effizient zu nutzen.
Für einen möglichst wirksamen Einsatz der Forschungsetats sind Forschungsprogramme sowohl für die Forschungseinrichtung als auch für die Mittelgeber ein wichtiges Instrument im Hinblick auf die Darstellung der Aktivitäten. Dies gilt insbesondere für die Ressortforschungseinrichtungen des Bundes, zu denen die Bundesanstalt für Materialforschung und -prüfung (BAM) zählt. Diese Einrichtungen verfügen über einen klaren Auftrag und ihre Forschung ist mit der Wahrnehmung öffentlicher Aufgaben verbunden. Forschungsprogramme dienen daher besonders in diesen Einrichtungen dazu, Perspektiven im Bereich ihres Aufgabenfeldes sowie ihre Forschungsaktivitäten transparent darzustellen und politisch vertretbar zu machen.
Das vorliegende Forschungsprogramm der BAM gibt einen Überblick über die in den nächsten Jahren aktuellen Forschungsthemen und die hierfür erforderlichen Ressourcen und Rahmenbedingungen.
Die voranschreitende Digitalisierung, die Globalisierung sowie die daraus resultierende beschleunigte technologische Entwicklung bringen heute für die Industrieländer Herausforderungen im Hinblick auf Wachstum, Beschäftigung und Strukturwandel mit sich, denen nur mit einer entsprechenden Innovationsdynamik und -dichte begegnet werden kann. Grundvoraussetzung hierfür ist eine leistungsfähige Forschung und Entwicklung ebenso wie Wissens- und Technologietransfer zur Umsetzung von Forschungsergebnissen in marktfähige Produkte und Dienstleistungen. Europa hat sich im Rahmen des Lissabon-Prozesses zum Ziel gesetzt, den Anteil der Forschungsausgaben am Bruttoinlandsprodukt auf 3 % zu steigern. Um die Forschungsinfrastruktur in der Bundesrepublik zu stärken und global wettbewerbsfähig zu bleiben, hat die Bundesregierung mit der Hightech-Strategie 2025 einen weiteren wichtigen Schritt zur Förderung des wissenschaftlich-technischen Fortschritts in Deutschland getan.
Forschungsprogramme sind sowohl für Forschungseinrichtungen als auch für Mittelgeber ein wichtiges Instrument für die Darstellung und Steuerung ihrer Aktivitäten. Dies gilt auch für die Bundeseinrichtungen mit Forschungs- und Entwicklungsaufgaben, zu denen die Bundesanstalt für Materialforschung und -prüfung (BAM) zählt. Die BAM verfügt über einen klaren gesetzlichen Auftrag für die Sicherheit in Technik und Chemie. Ihre Forschung ist mit der Wahrnehmung öffentlicher Aufgaben verbunden. Das Forschungsprogramm zeigt Perspektiven im Bereich ihres Aufgabenfeldes sowie ihrer damit verbundenen Forschungsaktivitäten transparent und politisch nutzbar auf und dient darüber hinaus der Koordinierung der Ressortforschung. Das Forschungsprogramm der BAM wird alle zwei Jahre aktualisiert. Es gibt einen Überblick über die aktuellen und zukünftigen Forschungsthemen und die hierfür erforderlichen Rahmenbedingungen.
Der Koalitionsvertrag der Bundesregierung betont in seiner Präambel zur Zukunft Deutschlands in Bezug auf die notwendige Modernisierung, dass „dieser Fortschritt auch mit einem Sicherheitsversprechen einhergehen muss“. Die Bundesanstalt für Materialforschung und -prüfung (BAM) stellt mit ihrem Auftrag „Sicherheit in Technik und Chemie“ und ihrer über 150-jährigen Kompetenz sicher, dass ein nachhaltiger technischer Fortschritt von einem Sicherheitsversprechen für die Bürger*innen begleitet ist.
Durch ihre Interdisziplinarität, die thematische Breite, die langjährige Erfahrung und die unabhängige Rolle als Ressortforschungseinrichtung ist die BAM in einer herausragenden Lage, als zentraler Akteur die Entwicklung unterschiedlichster Technologien unter Berücksichtigung sicherheitstechnischer Aspekte voranzubringen, das Vertrauen der Gesellschaft in diese Technologien sicherzustellen und dadurch die Basis für erfolgreiche Innovationen zu schaffen.
Der Fokus ihrer Arbeit liegt auf den fünf Themenfeldern Energie, Infrastruktur, Umwelt, Material und Analytical Sciences. Wichtige Themen betreffen dabei sowohl die Energiewende (Wasserstoff, elektrische Energiespeicher, Windenergie) als auch Bereiche der Technologiesouveränität wie die additive Fertigung, zuverlässige Materialdaten, Zustandsüberwachung und Kreislaufwirtschaft.
Die Digitalisierung und den digitalen Wandel unterstützt die BAM in Bezug auf technologieübergreifende Rahmenbedingungen besonders in der Initiative Qualitätsinfrastruktur-Digital (QI-Digital), in der gemeinsam mit weiteren zentralen Akteuren der deutschen QI Lösungen für die Qualitätssicherung in einer digitalisierten Welt entwickelt werden.
Grundvoraussetzung für sichere Technologien und Innovationen ist eine leistungsfähige Forschung und Entwicklung ebenso wie Wissens- und Technologietransfer zur Umsetzung von Forschungsergebnissen in marktfähige Produkte und Dienstleistungen. Dafür bildet die Arbeit der BAM eine wichtige Basis.
Ihre Forschung ist mit der Wahrnehmung öffentlicher Aufgaben verbunden. Das Forschungsprogramm zeigt Perspektiven im Bereich ihres Aufgabenfeldes sowie ihrer damit verbundenen Forschungsaktivitäten transparent und politisch nutzbar auf und dient darüber hinaus der Koordinierung der Ressortforschung.
Das Forschungsprogramm der BAM wird alle zwei Jahre aktualisiert. Es gibt einen Überblick über die aktuellen und zukünftigen Forschungsthemen und die hierfür erforderlichen Rahmenbedingungen.
„Getränkekühler optimal einsetzen“: So sparen Sie die Energiekosten und schonen das Klima.
Wussten Sie, dass Sie durch den Einsatz eines effizienten Getränkekühlers (Energieeffizienzklasse B) ca. 114 € pro Jahr sparen im Vergleich zu einem weniger effizienten Gerät (Energieeffizienzklasse D)? Aber nicht immer gibt es die Möglichkeit ein Neugerät anzuschaffen. Oft werden die Kühlgeräte von Getränkeherstellern zur Präsentation ihrer Waren zur Verfügung gestellt. Trotzdem tragen am Ende die Betreiber:innen die Betriebskosten der Geräte.
Aber auch beim Einsatz Ihres weniger effizienten Getränkekühler gibt es verschiedene Möglichkeiten, die Energiekosten zu senken. Beispielsweise kann schon der Einsatz einer Zeitschaltuhr zu einer Stromreduzierung von bis zu 50 Prozent oder auch die richtige Platzierung der Geräte an kühlen Orten ohne Zugluft zu einem geringeren Strombedarf von bis zu 30% führen.
In unserer Checkliste für die Aufstellung und das Betreiben von Getränkekühlgeräten zeigen wir Ihnen einfache Schritte, um den Energieverbrauch schnell zu senken.
Bei der Montage von Stahlkonstruktionen kommt es trotz anforderungsgerechter schweißtechnischer Fertigung vereinzelt zur Detektion von unzulässigen Unregelmäßigkeiten im Schweißbereich.
In einem Forschungsprojekt (FOSTA P1311) wurden Untersuchungen durchgeführt und Kenntnisse erarbeitet, um mittelfristig vor allem KMU beanspruchungsgerechte Reparaturkonzepte zur Verfügung zu stellen. Damit können letztlich Schäden und zumeist teure Nacharbeiten verhindert und eine verbesserte Ausnutzung des hohen Festigkeitspotentials hochfester Stähle erreicht werden. Gerade KMU können mit Blick auf die Kosten für Fertigung, Schweißarbeit und Material von den Erkenntnissen beim Einsatz hochfester Stähle, die für eine effiziente Realisierung der Energiewende in Deutschland notwendig sind, profitieren.
Protein immobilization for the functionalization of particles is used in various applications, including biosensors, lateral-flow immunoassays (LFIA), bead-based assays, and others. Common methods for the quantification of bound protein are measuring protein in the supernatant before and after coating and calculating the difference. This popular approach has the potential for a significant overestimation of the amount of immobilized protein since layers not directly bound to the surface (soft protein corona) are usually lost during washing and handling. Only the layer directly bound to the surface (hard corona) can be used in subsequent assays. A simplified amino acid analysis method based on acidic hydrolysis and RP-HPLC-FLD of tyrosine and phenylalanine (aromatic amino acid analysis, AAAA) is proposed to directly quantify protein bound to the surface of gold nano- and latex microparticles. The results are compared with indirect methods such as colorimetric protein assays, such as Bradford, bicinchoninic acid (BCA), as well as AAAA of the supernatant. For both particle types, these indirect quantification techniques show a protein overestimation of up to 1700% compared to the direct AAAA measurements. In addition, protein coating on latex particles was performed both passively through adsorption and covalently through EDC/sulfo-NHS chemistry. Our results showed no difference between the immobilization methodologies. This finding suggests that usual protein determination methods are no unambiguous proof of a covalent conjugation on particles or beads.
MALDI-TOF-MS-based identification of monoclonal murine anti-SARS-CoV-2 antibodies within one hour
(2022)
During the SARS-CoV-2 pandemic, many virus-binding monoclonal antibodies have been developed for clinical and diagnostic purposes. This underlines the importance of antibodies as universal bioanalytical reagents. However, little attention is given to the reproducibility crisis that scientific studies are still facing to date. In a recent study, not even half of all research antibodies mentioned in publications could be identified at all. This should spark more efforts in the search for practical solutions for the traceability of antibodies. For this purpose, we used thirty-five monoclonal antibodies against SARS-CoV-2 to demonstrate how sequence-independent antibody identification can be achieved by simple means applied onto the protein. First, we examined the intact and light chain masses of the antibodies relative to the reference material NIST-mAb 8671. Already half of the antibodies could be identified based solely on these two parameters. In addition, we developed two complementary peptide mass fingerprinting methods with MALDI-TOF-MS that can be performed in 45 minutes and had a combined sequence coverage of over 80%. One method is based on the partial acidic hydrolysis of the protein by 5 mM of sulfuric acid at 99 °C. Furthermore, we established a fast way for a tryptic digest without an alkylation step. We were able to show that the distinction of clones is possible simply by a brief visual comparison of the mass spectra. In this work, two clones originating from the same immunization gave the same fingerprints. Later, a hybridoma sequencing confirmed the sequence identity of these sister clones. In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0 (https://gets.shinyapps.io/ABID/). This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
T cells need to adapt their cellular metabolism for effector cell differentiation. This relies on alterations in mitochondrial physiology. Which signals and molecules regulate those alterations remains unclear. We recently reported, that the mitochondrial protein TCAIM inhibits activation-induced changes in mitochondrial morphology and function and thus, CD effector T cell formation. Using conditional TCAIM knock-in (KI) and knockout (KO) mice, w now show that it also applies to CD8+ T cells and more importantly, delineate the molecular processes in mitochondria by which TCAIM controls effector cell differentiation. TCAIM KI resulted in reduced activation-induced HIF1α protein expression. Metabolomics and transcriptional data in combination with mathematical flux modeling revealed an impaired induction of anabolic pathways, especially of the mevalonate pathway and cholesterol biosynthesis in TCAIM KI CD8+ T cells. Addition of cholesterol completely rescued HIF1α protein expression, activation and proliferation of TCAIM KI CD8+ T cells. At the molecular level, TCAIM delayed activation-induced mitochondria-ER contact (MERC) formation by binding to MERC promoting proteins such as RMD3 and VDAC2. In summary, we demonstrate that TCAIM suppresses effector cell differentiation by inhibiting MERC formation, which induce HIF1α-mediated increase in cellular metabolism and cholesterol biosynthesis.
This document presents the specification for the execution and evaluation of high-speed tensile tests on reinforcement bar coupler systems. This specification was developed at BAM - Bundesanstalt für Materialforschung und -prüfung (Federal Institute for Materials Research and Testing, Germany) - following test principles from related international standards.
The present document represents the latest status of the test specification. It is noted that until 2010 the test procedure was characterised on a test velocity based on L0. In an improved test conception and after intensive investigations in cooperation with industry partners, this procedure has been updated to consider instead a test velocity based on Lr, since this warrants more comparable and meaningful results.
Das gegenwärtige globale Wirtschaftsmodell basiert auf dem Prinzip linearen Wachstums. Aufgrund der Endlichkeit natürlicher Ressourcen wird dieser Wachstumsgedanke in Zukunft jedoch an Grenzen stoßen. Schon in den 1960er Jahren haben Ökonomen das Modell einer Kreislaufwirtschaft, einer Circular Economy, entwickelt. Es zielt darauf ab, den Gebrauchswert von Ressourcen entlang der gesamten Wertschöpfungskette zu optimieren und Materialkreisläufe zu schließen.
2019 hat die Europäische Kommission ihren Aktionsplan zur Circular Economy aus dem Jahr 2015 bekräftigt und aktualisiert. Auch die deutsche Bundesregierung unterstützt diese internationalen Bemühungen seit langem mit ihrer Nachhaltigkeitsstrategie und ihrem Ressourceneffizienzprogramm.
Die Bundesanstalt für Materialforschung und -prüfung (BAM) ist in vielfältiger Weise in diese Aktivitäten involviert. Unter dem Motto „Sicherheit in Technik und Chemie“ arbeiten wir gemeinsam mit Partnern aus Wirtschaft und Forschung im Bereich der Prozess- und Produktsicherheit sowie der Umweltsicherheit. Dabei legen wir besonderes Augenmerk auf Ressourceneffizienz, indem wir neue Verfahren zur Extraktion wertvoller Ressourcen aus Abfällen und zur Wiederverwertung von Massenreststoffen entwickeln. Wir analysieren die Beständigkeit und das Alterungsverhalten von Kunststoffen und untersuchen die Umweltverträglichkeit und Dauerhaftigkeit innovativer Bauprodukte aus Abfällen.
Zudem ist die BAM in nationalen und internationalen Gremien bei der Normung und Regelsetzung im Bereich Kreislaufwirtschaft tätig und fördert den Wissensaustausch zwischen Forschung und Industrie. So leisten wir einen wichtigen Beitrag zur Transformation der deutschen und europäischen Wirtschaft hin zu einer Circular Economy.
In the last years, the Process Analytical Technology (PAT) research field has become of great importance due to its connection with the industrial world. This industry related research, along with the evolutionary progress that technology has seen lately, has allowed that key analytical techniques in an industrial environment have undergone a radical development. One of these techniques has been the near-infrared spectroscopy (NIRS). This technique, currently common in "online" industrial analysis, has seen a remarkable revolution, especially since the introduction of the microelectromechanical systems technology (MEMS) in the spectroscopy field. Nowadays it is possible to find compact spectrometers no bigger than a wristwatch in the market. Although there is an unavoidable question: can these compact spectrometers actually compete against the traditional spectrometers?
In this project different calibration parameters of two compact NIR spectrometers ("Spectral Engines Oy NIR-One Sensor NM2.0", with 1550 to 1950 nm range; and "NeoSpectra Si-ware", with 1300 to 2550 nm range) were evaluated, and the obtained results were compared with a reference spectrometer ("Bruker Optik GmbH Matrix-F", with 15000 to 4000 cm–1 range). In order to obtain the different calibration parameters, a sequence of quality performance tests were conducted. The results obtained after the different experiments carried out with both compact spectrometers prove that their performance is more than acceptable for routine analysis.
Afterward, model samples of different microplastics in soil at different known concentration were analyzed with all three spectrometers. Chemometric models capable to identify and classify microplastics in soil were established. For this analysis five of the most used plastics worldwide were used: polyethylene (PE), polyethylene terephthalate (PET), polypropylene (PP), polystyrene (PS), and polyvinyl chloride (PVC). After the Principal component analysis (PCA), it can be seen that only the NIR-One NM2.0 is capable to differentiate all types of microplastics in soil at concentrations of 1–2 %, while the NeoSpectra Si-ware is unable to identify the PET sample.
Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik: Polyzyklische aromatische Kohlenwasserstoffe (PAK) in Boden, Mineralölkohlenwasserstoffe (MKW) in Boden, Elemente in Sediment und Gesamtcyanid in Boden.
Four cement-based and four calcium-sulphate-based screed types are investigated. The samples have a diameter of 300 mm and a height of 35 or 70 mm. Up to ten humidity sensors are embedded directly during the concreting of the screed samples. Thus, the humidity over the sample height is monitored during hardening, hydration, evaporation, and oven drying. Furthermore, the screed samples are weighted during every measurement to determine the total mass and the corresponding moisture loss.
To define the pore system precisely, mercury intrusion porosimetry as well as gas adsorption is performed. According to the data, the entire pore volume distribution is known. The measured pore diameters range from 0.8 nm to 100 μm and the total porosity of the examined screeds ranges between 11 % and 22 %.
Based on these measurement data, moisture transport, pore saturation as well as sorption isotherms and their hysteresis may be calculated quantitatively as described by Strangfeld et al.
Globalisierung und die beschleunigte technologische Entwicklung bringen heute für die Industrieländer Herausforderungen im Hinblick auf Wachstum, Beschäftigung und Strukturwandel mit sich, denen nur mit einer entsprechenden Innovationsdynamik und -dichte begegnet werden kann. Grundvoraussetzung hierfür ist eine leistungsfähige Forschung und Entwicklung ebenso wie Wissens- und Technologietransfer zur Umsetzung von Forschungsergebnissen in marktfähige Produkte und Dienstleistungen. Europa hat sich im Rahmen des Lissabon-Prozesses zum Ziel gesetzt, den Anteil der Forschungsausgaben am Bruttoinlandsprodukt auf 3 % zu steigern. Um die Forschungsinfrastruktur in der Bundesrepublik zu stärken und global wettbewerbsfähig zu bleiben, hat die Bundesregierung mit der Hightech-Strategie einen weiteren wichtigen Schritt zur Förderung des wissenschaftlich-technischen Fortschritts in Deutschland getan.
Forschungsprogramme sind sowohl für Forschungseinrichtungen als auch für Mittelgeber ein wichtiges Instrument für die Darstellung und Steuerung ihrer Aktivitäten. Dies gilt auch für die Bundeseinrichtungen mit Forschungs- und Entwicklungsaufgaben, zu denen die Bundesanstalt für Materialforschung und -prüfung (BAM) zählt. Die BAM verfügt über einen klaren gesetzlichen Auftrag für die Sicherheit in Technik und Chemie. Ihre Forschung ist mit der Wahrnehmung öffentlicher Aufgaben verbunden. Das Forschungsprogramm zeigt Perspektiven im Bereich ihres Aufgabenfeldes sowie ihrer damit verbundenen Forschungsaktivitäten transparent und politisch nutzbar auf und dient darüber hinaus der Koordinierung der Ressortforschung. Das Forschungsprogramm der BAM wird alle zwei Jahre aktualisiert. Es gibt einen Überblick über die aktuellen und zukünftigen Forschungsthemen und die hierfür erforderlichen Rahmenbedingungen.
ISO 10156:2010 contains a test method and a calculation method for flammability of gases and gas mixtures for the selection of cylinder valve outlets. The calculation method is used also to classify gas mixtures according to the national and international dangerous goods and dangerous substances regulations, e.g. according to the UN Recommendations on the Transport of Dangerous Goods (UN TDG) and the Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS). The calculation method for gas mixtures requires substance parameters of the single components. These are the coefficients for the fire potential (Tci) and for inerting ability, the so-called nitrogen equivalence (Kk), which have been estimated conservatively by means of flammability data.
BAM checked Tci and Kk values of ISO 10156:1996 using three-component diagrams (Flammable gas-Inert-Air) of the CHEMSAFE® database. The experimental fundamentals and the principles of the calculation method are summarized in this paper. The revised data for Tci and Kk values were adopted in the tables of ISO 10156:2010.
Furthermore, subcategorization of flammable gases has been proposed by a UN working group and shall be implemented in the GHS in the meantime. The subcategorization requires the lower flammability limit (LFL) as an additional indicator. Therefore, a test method and a calculation method for LFL were proposed by BAM and have been implemented in the new draft of ISO/CD 10156:2016.
The calculation method for gas mixtures is based on Le Chatelier’s rule and was extended by using the Kk values for inert components in the mixture. The calculated LFLs of methane-inert gas mixtures were compared with experimental values for different types of inert gases. It could be shown that calculated LFLs are in good agreement with experimental values if the Kk values derived from three-component flammability diagrams are used. Although using the Kk values of ISO 10156:2010 leads to higher deviations, the results are still on the safe side.
Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik: Polyzyklische aromatische Kohlenwasserstoffe (PAK) in Boden, Mineralölkohlenwasserstoffe (MKW) in Boden, Elemente in Sediment und Gesamtcyanid in Boden.
The SUSAN-project aimed at developing a sustainable and safe strategy for nutrient recovery from sewage sludges using thermal treatment. Mono-incineration of the sludges completely destructs the organic pollutants in a first step. The incineration residues are ashes with a high phosphorus content that still contain heavy metal compounds above the limits for agricultural use. Furthermore, phosphorus in the ashes exhibits low bioavailability - a disadvantage in farming. Therefore, in a second thermochemical step heavy metals are removed and phosphorus transferred into mineral phases available for plants. The principle of the SUSAN-project is the separation of the small heavy metals fraction from the ashes to receive a phosphorus rich product suited as raw material for fertilisers that also contains SiO2, CaO, Al2O3, Fe2O3, MgO and K2O.
The thermochemical process is based on evaporation of volatile heavy metal chlorides at 850 - 1000 °C. The sewage sludge ashes are mixed with chlorine donors such as MgCl2 or KCl, grained and treated in a thermal aggregate e.g. a rotary furnace. At the same time a transfer of non soluble P-compounds into Mineral phases available for plants takes place.
Besides technological development of the thermochemical process, the products fertilisation performance, the product design, the market for the products and the sustainability of the whole process chain are emphasised in the SUSAN-project.