BAM Präsentationen
Filtern
Erscheinungsjahr
- 2021 (12) (entfernen)
Dokumenttyp
- Posterpräsentation (8)
- Vortrag (4)
Referierte Publikation
- nein (12)
Schlagworte
- Knowledge Readiness Level (3)
- Data (2)
- Acceptance (1)
- Acoustic emission (1)
- Al-Si alloys (1)
- AlSi12CuMgNi (1)
- Bridge Monitoring (1)
- Charakterisierung von Brennflecken (1)
- Coda Wave Interferometry (1)
- Data Management (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (9)
- 8.0 Abteilungsleitung und andere (6)
- 6 Materialchemie (3)
- 6.1 Oberflächen- und Dünnschichtanalyse (3)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (1)
- 8.4 Akustische und elektromagnetische Verfahren (1)
- 8.5 Röntgenbildgebung (1)
Eingeladener Vortrag
- nein (4)
Typically, the near-eutectic Al-Si alloys consist of highly interconnected three-dimensional network of the eutectic Silicon (Si) and intermetallics embedded into Aluminium (Al) matrix. For further improvement of the mechanical properties of such alloys, often, one single ceramic reinforcement phase, e.g. silicon carbide (SiC) or aluminium oxide (Al2O3) in the form of fibres or particles is added. However, hybrid reinforcements (fibres and particles) can further improve wear resistance and fracture toughness, and additionally, reduce anisotropy of the material. The engineering of metal matrix composites (MMC) for specific application requirements benefits from a comprehensive knowledge of the failure behaviour. Therefore, damage evolution under compression was investigated on:
- pure near-eutectic AlSi12CuMgNi matrix alloy
- type I: matrix reinforced with random-planar oriented Al2O3 short fibres (15 vol.%)
- type II: matrix reinforced with random-planar oriented Al2O3 short fibres (7 vol.%) and additional SiC particles (15 vol.%)
The analysis of damage mechanism was carried out in two rather independent but complementary studies. First, selected sister samples of every material were exposed to quasi-static compression (traverse control). The compression tests were interrupted at different strain levels. Miniature cylinders with a diameter of 1mm were extracted from the pre-strained samples and investigated by synchrotron computed tomography (SX-µCT) with a spatial resolution of about 0.7 µm. For the pure matrix alloy, microcracks are confined to the intermetallic particles and to the eutectic Si, hence no damage was observed in the Aluminium. The composite type II revealed a more effective strain accumulation (less damage) than type I at low plastic strain (up to 5 %), but a more catastrophic damage development due to cracking of the SiC clusters at higher strain levels.
The second approach to study the damage initiation and accumulation in the materials subjected to compressive load was Acoustic Emission (AE) analysis. In this case the in-situ monitoring of the acoustic emission signal was performed during compression tests on specimens with dimension of several mm. For all three material types, AE activity set at 2% strain. Differences in AE behaviour of the three materials was proven based on AE hitrate, signal peak amplitudes as well as weighted peak frequencies (WPF). Future work focuses on combination of AE and SX-µCT aiming for more detailed knowledge on damage mechanism of metal matrix composites.
Nanomaterials bring various benefits and have become a part of our daily lives. However, the risks emerging from nanotechnology need to be minimized and controlled at the regulatory level and therefore, there is a need for nanorisk governance. One of the prerequisites for successful nanorisk governance is the availability of high-quality data on nanomaterials and their impact with the human body and the environment. In recent decades, a countless number of publications and studies on nanomaterials and their properties have been produced due to the fast development of nanotechnology. Despite such a vast amount of data and information, there are certain knowledge gaps hindering an efficient nanorisk governance process. Knowing the state of the available data and information is an important requirement for any decision maker in dealing with risks. In the specific case of nanotechnology, where most of the risks are complex, ambiguous, and uncertain in nature, it is essential to obtain complete data and metadata, to fill knowledge gaps, and to transform the available knowledge into functional knowledge. This can become possible using a novel approach developed within the NANORIGO project (Grant agreement No. 814530) – the Knowledge Readiness Level (KaRL). In analogy to NASA’s Technology Readiness Levels (TRLs), we define KaRLs as a categorization system of data, information, and knowledge which enables transformation of data and information into functional knowledge for nanorisk governance. Our approach goes beyond the technical curation of data and metadata and involves quality and completeness filters, regulatory compliance requirements, nanorisk-related tools, and most importantly, human input (inclusion of all stakeholder groups). With the KaRL approach we also address key issues in nanotechnology such as societal and ethical concerns, circular economies and sustainability, the Green Deal, and the traceability of data, knowledge, and decisions. The KaRL approach could be used for nanorisk governance by a nanorisk governance council (NRGC), which is currently under development by three EU projects (NANORIGO, GOV4NANO, and RISKGONE).
Nach Auftreten eines Feuchteschadens in Fußbodenaufbauten sind sowohl die zeitnahe Feststellung als auch Eingrenzung betroffener Bereiche von besonderer Bedeutung. So können erforderliche Renovierungsmaßnahmen effizient geplant und mögliche Folgeschäden vermieden werden. Zur messtechnischen Beantwortung dieser Fragestellungen werden bereits seit vielen Jahren Neutronensonden eingesetzt, welche allerdings keine Tiefenzuordnung des schadensträchtigen Flüssigwassers zulassen. Hierzu müssen mit hohem zeitlichem und finanziellem Aufwand zerstörende Sondierungsbohrungen vorgenommen werden, welche zukünftig durch den parallelen Einsatz des Radarverfahrens vermieden werden könnten. In systematischen Laborstudien wurden gängige Feuchteschäden an häufig anzutreffenden Fußbodenaufbauten simuliert und deren Einfluss auf das Messsignal untersucht. Hierbei kamen Zementund Anhydritestriche, sowie die Dämmmaterialen Styropor, Styrodur, Glaswolle und Perlite-Schüttung mit variierenden Schichtdicken zum Einsatz, um die vielfältigen Konfigurationen der Praxis abzubilden. Für den gewonnenen Datensatz konnten geeignete Signalmerkmale extrahiert werden, welche mithilfe multivariater Datenauswertung eine Klassifizierung des vorliegenden Schadenfalls zulassen. Zum Ende des Forschungsvorhabens steht besonders die Anwendbarkeit der entwickelten Methoden für die Praxis im Fokus. Hierzu wurden Messungen an realen Schadensfällen durchgeführt und deren Ergebnisse mit den Laboruntersuchungen verglichen. Hierbei stellten sich variierende Schichtdicken, sowie vorkommende Fußbodenheizungen und Armierungsgitter als mögliche Fehlerquellen für eine vollständig automatisierte Auswertung heraus.
Nanomaterials bring various benefits and have become a part of our daily lives. However, the risks emerging from nanotechnology need to be minimized and controlled at the regulatory level and therefore, there is a need for nanorisk governance. One of the prerequisites for successful nanorisk governance is the availability of high-quality data on nanomaterials and their impact with the human body and the environment. In recent decades, a countless number of publications and studies on nanomaterials and their properties have been produced due to the fast development of nanotechnology. Despite such a vast amount of data and information, there are certain knowledge gaps hindering an efficient nanorisk governance process. Knowing the state of the available data and information is an important requirement for any decision maker in dealing with risks. In the specific case of nanotechnology, where most of the risks are complex, ambiguous, and uncertain in nature, it is essential to obtain complete data and metadata, to fill knowledge gaps, and to transform the available knowledge into functional knowledge. This can become possible using a novel approach developed within the NANORIGO project (Grant agreement No. 814530) – the Knowledge Readiness Level (KaRL). In analogy to NASA’s Technology Readiness Levels (TRLs), we define KaRLs as a categorization system of data, information, and knowledge which enables transformation of data and information into functional knowledge for nanorisk governance. Our approach goes beyond the technical curation of data and metadata and involves quality and completeness filters, regulatory compliance requirements, nanorisk-related tools, and most importantly, human input (inclusion of all stakeholder groups). With the KaRL approach we also address key issues in nanotechnology such as societal and ethical concerns, circular economies and sustainability, the Green Deal, and the traceability of data, knowledge, and decisions. The KaRL approach could be used for nanorisk governance by a nanorisk governance council (NRGC), which is currently under development by three EU projects (NANORIGO, GOV4NANO, and RISKGONE).
Regulatory decisions require reliable data and knowledge derived from this. Among stakeholders in nanotechnology, however, there is often uncertainty about the quality of data for regulatory purposes. In addition, the general public often finds itself excluded from nanoregulation and policy decisions. This creates uncertainty in the nanotechnology field and also in other branches of technology and leads to concerns among the society.
To address these issues, NANORIGO elaborates a framework to support decision making as well as data, information and knowledge sharing and use. We refer to “reliability” of data and knowledge as a degree of readiness or maturity. According to these criteria we worked out a 9-level scale in analogy to TRL (technology readiness level), the KaRL system (Knowledge, Data and Information Readiness Level). KaRL allows assessment of knowledge readiness for decision making by applying defined quality criteria for each level. It also provides guidance on how to enhance the readiness level by the help of available tools and procedures. KaRL addresses SEIN[1] principles, circular economy and thus involves the public concerns in regulation. A specialized nanorisk governance council (being under development in NANORIGO) is suggested to perform quality check of an actionable document, thus, aiding in consensus on the reliability (maturity) of knowledge for decision making. Moreover, KaRL facilitates traceability of knowledge before its use in decision making. This enables the transparency demanded by all stakeholders.
Die luftgekoppelte Ultraschallprüfung (ACUT) ist ein vielfach bewährtes zerstörungsfreies Prüfverfahren, welches von vielen Anwendern jedoch nur am Rande oder gar nicht wahrgenommen wird. Insbesondere, die nach wie vor in der Ultraschallausbildung gelehrten Theorien zur wellenlängenabhängigen minimalen detektierbaren Fehlergröße und die vermeintliche Notwendigkeit der Verwendung von Koppelmittel schrecken viele potentielle Anwender davon ab für ihr
Prüfproblem ACUT in Betracht zu ziehen. Des Weiteren wird ACUT häufig nicht als eigenständiges Prüfverfahren erkannt, sodass versucht wird, flüssigkeitsgekoppelte Ultraschallprüfungen ohne Beachtung der Besonderheiten zu ersetzen.
Monitoring of reinforced concrete structures to ensure their stability and increase their service-life is a crucial element of a modern infrastructural concept. With classical methods of non-destructive testing and inspection, repeated measurements under comparable conditions are difficult to conduct. Therefore, DFG research unit FOR 2825 CoDA researches the assessment of concrete damage using ultrasound coda wave interferometry and embedded sensors. Embedding the sensors into the monitoring target reduces human and non-human factors influencing repeatability. Using Coda Wave Interferometry (CWI), small velocity changes in the material can be detected by comparison of repeated measurements. The technique is sensitive to damaging changes like cracking as well as to reversible influences like material temperature. The understanding of these different influences on the signal is crucial for the analysis of long-term monitoring data to make an educated assessment of the structure and its integrity. With several laboratory experiments in a climate chamber and a long-term experiment recording an annual cycle in a large model on an outdoor test site in Horstwalde close to Berlin, we try to understand the influence of temperature on the CWI results. The results show that the velocity change calculated by CWI does closely follow the trend of concrete temperature. After one year of data recording with the large model being exposed to environmental variations only, the calculated velocity change resembles the annual temperature curve. The data shows a linear dependency between velocity and temperature change in a range of -0.03 percent per °K to -0.06 percent per °K - regardless of specimen size. An approach to remove temperature influence from the yearly cycle recorded in the large-scale experiment using this linear relation is unable to remove high-frequency variations - especially daily influences. Low-pass filtering the data can eliminate these variations while preserving permanent shifts caused by damages. Although we have shown that the influence of temperature on long term monitoring can be removed to a significant extent, there is still an influence of environmental changes remaining in the data. Possible nonlinear effects and influences not related to temperature need to be investigated in the future.
Die zerstörungsfreie Ermittlung der Materialfeuchte in Baustoffen ist für das Bauwesen von großer Bedeutung, denn ein erhöhter Feuchteeintrag kann zu Schimmelbildung, Alkali-Kieselsäure-Reaktionen, Korrosion etc. führen und somit ein hohes Schadenspotential mit sich bringen. Auch wenn zur qualitativen Lokalisierung möglicher Schad- und Risikostellen bereits zahlreiche zerstörungsfreie Verfahren in der Praxis Anwendung finden, besteht ein Mangel an quantitativen Verfahren, die auch bei niedrigen Feuchtegehalten sensitiv sind. Eine Methode zur zerstörungsfreien und quantitativen Bestimmung des Feuchtegehaltes und der effektiven Porosität ist die 1H-Kernspinresonzanzmethode (NMR). Da NMR sensitiv für die molekulare Beweglichkeit von Wasserstoffprotonen ist, lassen sich Informationen über die Bindungsform und -stärke sowie der Umgebung (Porengröße und Mineralzusammensetzung) der Wasserstoffprotonen gewinnen. Obwohl es bereits seit über 20 Jahren mobile NMR-Messeräte gibt, wird NMR heutzutage immer noch weitestgehend im Labor eingesetzt. Dies liegt daran, dass sie aufgrund der verwendeten Permanentmagnete schwer sind und nur äußerst geringe Eindringtiefen ermöglichen. In einer derzeit laufenden Forschungsarbeit wird deshalb ein speziell für Bohrkerne entworfener NMR-Tomograph eingesetzt. Mit seiner minimalen Echozeit von 50 µs lässt sich (abhängig von der Oberflächenrelaxivität) Wasser bis in nanometergroßen Poren erfassen. Um die Sensitivität von NMR bei Teilsättigung zu untersuchen, wurden verschiedene Sandsteinproben in Exsikkatoren mit relativen Luftfeuchten im Bereich von 33 % bis 96 % gelagert. Als Referenzen dienen zum einen das NMR-Signal bei Vollsättigung und zum anderen die Porengrößenverteilung aus Quecksilberporosimetriemessungen (MIP). Um die NMR-Sensitivität zu bewerten, wird die Korrelation der NMR-Amplitude mit den gravimetrisch ermittelten Feuchtegehalten sowie ein Vergleich der Porosität aus NMR und MIP betrachtet. Zu beachten ist in diesem Zusammenhang, dass sowohl die Reduzierung der Wasserfilmdicke als auch die Verkleinerung von Porengrößen zu einer ähnlichen Verkürzung der T2-Relaxationszeit führt. Als Ausblick wird ein Lösungsansatz vorgestellt, bei dem die NMR-Signale mit der Wasserfilmdickenberechnung basierend auf der relativen Luftfeuchte im Material korreliert werden.
The successful shift to NDE 4.0 will not only require developing and embracing new technologies associated with the fourth industrial revolution or becoming an integral part of the overall Industry 4.0, but also developing and adopting new ways of working. It is undoubtful that people will remain in charge of the inspections. However, it is arguable if the current “procedure-following” “level I-III” paradigm can withstand the changes that come along NDE 4.0. With the increased autonomy and interconnectedness expected with NDT 4.0, the majority of traditional NDE tasks will no longer be needed. Instead, different skills, such as that of programming and adapting systems, as well as problem solving, will become vital for the inspections. Therefore, we suggest that a new paradigm is needed—one in which inspector roles and, thus, also the requirements will have to be reinvented. We expect the inspectors to be relieved from the tedious and error prone aspects of the current system and to take responsibility for increasingly complex automated systems and work in closer collaboration with other experts. Thus, we propose that the traditional inspector roles will be transformed into that of the system developer, caretaker and problem solver, each requiring a specific set of skills and assuming different responsibilities. In this talk, we will present the new roles and discuss the challenges that may arise with them.
Die thermografische ZfP basiert auf der Wechselwirkung von thermischen Wellen mit Inhomogenitäten. Die Ausbreitung von thermischen Wellen von der Wärmequelle zur Inhomogenität und zur Detektionsoberfläche entsprechend der thermischen Diffusionsgleichung führt dazu, dass zwei eng beieinander liegende Defekte fälschlicherweise als ein Defekt im gemessenen Thermogramm erkannt werden können. Um diese räumliche Auflösungsgrenze zu durchbrechen, also eine Super Resolution zu realisieren, kann die Kombination von räumlich strukturierter Erwärmung und numerischen Verfahren des Compressed Sensings verwendet werden.
Für unsere Arbeiten benutzen wir Hochleistungs-Laser im Kilowatt-Bereich um die Probe entweder hochaufgelöst entlang einer Linie (1D) abzurastern oder strukturiert zu erwärmen. Die Verbesserung des räumlichen Auflösungsvermögens zur Defekterkennung hängt dann im klassischen Sinne direkt von der Anzahl der Messungen ab. Mithilfe des Compressed Sensings und Vorkenntnissen über das System ist es jedoch möglich die Anzahl der Messungen zu reduzieren und trotzdem Super Resolution zu erzielen. Wie viele Messungen notwendig sind und wie groß der Auflösungsgewinn gegenüber der konventionellen thermografischen Prüfung mit flächiger Erwärmung ist, hängt von einer Reihe von Messparametern, der Messstrategie, Probeneigenschaften und den verwendeten Rekonstruktionsalgorithmen ab.
Unsere Studien befassen sich mit dem Einfluss der experimentellen Parameter, wie z.B. der Pulslänge der Laserbeleuchtung und der Größe des Laserspots. Weiterhin haben wir uns mit der Wahl der Parameter in der Rekonstruktion auseinandergesetzt, die einen Einfluss auf das im Compressed Sensing zugrundeliegende Minimierungsproblem haben. Für jeden getesteten Parametersatz wurde eine Rekonstruktionsqualität berechnet. Schließlich wurden die Defektrekonstruktionen basierend auf den Parameternsätzen verglichen, sodass eine Parameterwahl für hohe Rekonstruktionsqualitäten mit thermografischer Super Resolution empfohlen werden kann.