BAM Präsentationen
Filtern
Erscheinungsjahr
Dokumenttyp
- Posterpräsentation (41)
- Vortrag (36)
- Beitrag zu einem Tagungsband (7)
Referierte Publikation
- nein (84)
Schlagworte
- CONSENS (16)
- Online NMR Spectroscopy (14)
- Online NMR spectroscopy (13)
- Process Monitoring (12)
- Indirect Hard Modeling (10)
- Industrie 4.0 (8)
- Prozessanalytik (7)
- Smart Sensors (7)
- Process analytical technology (6)
- Process Analytical Technology (5)
- Process control (5)
- Beton (4)
- Feuchte (4)
- NMR (4)
- Prozess-Sensoren 4.0 (4)
- Reaction monitoring (4)
- Zerstörungsfreie Prüfung (4)
- Automated data evaluation (3)
- Indirect hard modeling (3)
- Knowledge Readiness Level (3)
- Process Control (3)
- Radar (3)
- Reaction Monitoring (3)
- SMASH (3)
- Thermografie (3)
- ZfP (3)
- Continuous Manufacturing (2)
- Data (2)
- Fußboden (2)
- LIBS (2)
- NDT (2)
- Neutronensonde (2)
- Oberflächenrelaxivität (2)
- Online NMR Spektroskopie (2)
- Online-NMR-Spektroskopie (2)
- Sandsteine (2)
- Schallemissionsprüfung (2)
- Spectral Modeling (2)
- Spectral modeling (2)
- Super resolution (2)
- Thermography (2)
- qNMR (2)
- AKR (1)
- Abbruchstatik (1)
- Acceptance (1)
- Acoustic emission (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Airport security (1)
- Aktive Thermografie (1)
- Al-Si alloys (1)
- AlSi12CuMgNi (1)
- Alkali-Kieselsäure-Reaktion (1)
- Alkalien (1)
- Amorphous phases (1)
- Aqueous solution (1)
- Austenitische Schweißnähte (1)
- Automation (1)
- Basic Statistics (1)
- Baustoffe (1)
- Bauwerkssicherheit (1)
- Betonfahrbahndecken (1)
- Betonstahlkorrosion (1)
- Brandverhalten (1)
- Bridge Monitoring (1)
- Brückenbauwerke (1)
- Charakterisierung von Brennflecken (1)
- Chemometrics (1)
- Chlorid (1)
- Coda Wave Interferometry (1)
- Compatible solute (1)
- Concrete (1)
- Cracks (1)
- DLP (1)
- DMD (1)
- Data Analysis (1)
- Data Management (1)
- Data analysis (1)
- Digitalization (1)
- Direct loop control (1)
- Dosimetry (1)
- Druckbehälter (1)
- Ectoin (1)
- Ectoine (1)
- Ectoine radiation protection (1)
- Ectoine radical scavenger (1)
- Eingeschlossene Defekte (1)
- Embedded spectroscopy (1)
- Ermüdungsverhalten (1)
- Estrich (1)
- Eurosensors (1)
- Explosion Safety (1)
- Explosives (1)
- Faserkunststoffverbund (1)
- Feuchtegehalt (1)
- Field Integration (1)
- Flow Cell (1)
- Flow cell (1)
- Flüssigwasser (1)
- GPS (1)
- Geant4 (1)
- Gold surface (1)
- High-speed biosensor (1)
- Human Factors (1)
- Human-Centered Approach (1)
- Human-Machine Interaction (1)
- Hydratation (1)
- Hydrogenation (1)
- Hydroxyectoine (1)
- Hydroxyl radical (1)
- Hygrometrie (1)
- Image resolution (1)
- Immunosensor (1)
- Industry 4.0 (1)
- Inhibition assay (1)
- Inspection (1)
- Inspection Personnel (1)
- Ionizing radiation (1)
- Kalziumsilikat (1)
- Keramikdurchflusszelle (1)
- Klassifikation (1)
- Klimawechsellagerung (1)
- Knowledge (1)
- Korrosion (1)
- Laser Thermography (1)
- Limit of Detection (1)
- Line prediction (1)
- Linear Regression (1)
- Lithiation (1)
- Low energy electrons (1)
- Low field NMR spectroscopy (1)
- Low-Field NMR spectroscopy (1)
- Luftgekoppelte Ultraschallprüfung (1)
- MRFA (1)
- Mesoporosity (1)
- Messung (1)
- Messunsicherheit (1)
- Metrology (1)
- Modular Production (1)
- Modular production plants (1)
- Modular production units (1)
- Modularised production (1)
- NDE 4.0 (1)
- NMR Spectroscopy (1)
- NMR Validation (1)
- NMR sensor (1)
- NMR spectroscopy (1)
- Nachrechnung (1)
- Nachrechnungsrichtlinie (1)
- Nanomaterials (1)
- Nanorisk (1)
- Nanorisk Governance (1)
- Nasschemie (1)
- Niederfeld-NMR (1)
- Niederfeld-NMR-Spektroskopie (1)
- Non-Destructive Evaluation (1)
- Numerical methods (1)
- OH-radical (1)
- OPC UA (1)
- Oberflächenschutzsysteme (1)
- Online monitoring (1)
- Online reaction monitoring (1)
- Online-NMR (1)
- Onotology (1)
- Ontologien (1)
- Ontology (1)
- Open data (1)
- Open science (1)
- Osmolyte (1)
- PEG (1)
- Participatory Approach (1)
- Pharmaceutical Production (1)
- Phosphates (1)
- Photothermisch (1)
- Polyethylene glycol (1)
- Porengrößen (1)
- Porengrößenverteilung (1)
- Porosität (1)
- Potentialfeldmessung (1)
- Process sensors (1)
- Projektor (1)
- Prozessindustrie (1)
- Quantitative NMR Spectroscopy (1)
- Quantitative NMR spectroscopy (1)
- Radiation damage (1)
- Radiation protection (1)
- Radical scavenger (1)
- Radiographic testing (1)
- Radiographie (1)
- Reaktionsmonitoring (1)
- Relaxometrie (1)
- Reproducible Science (1)
- Reproduzierbare Wissenschaft (1)
- Research data management (1)
- Reversibility (1)
- Risk Governance (1)
- Roadmap (1)
- Röntgenrefraktionsmessung (1)
- Röntgenröhren (1)
- Röntgenrückstreuradiographie (1)
- SAFT (1)
- Schichtdickenbestimmung (1)
- Schlitzblendenkamera (1)
- Schädigung (1)
- Selectivity (1)
- Self-assembled monolayer (1)
- Semantic Data Management (1)
- Semantisches Datenmanagement (1)
- Sensitivity (1)
- Signalmerkmale (1)
- Smart sensors (1)
- Smarte Sensoren (1)
- Spannbetonbrücke (1)
- Spannbetonschwelle (1)
- Structural health monitoring (1)
- Strukturiert (1)
- Struvite (1)
- Sulfat (1)
- Super-resolution (1)
- Sustainability (1)
- TNT (1)
- Tausalzeintrag (1)
- Tension (1)
- Thermische Simulation (1)
- Thermischer Kontakt (1)
- Tomographie (1)
- Transition metals (1)
- Trinitrotoluene (1)
- Ultraschall (1)
- Ultraschallprüfung (1)
- Ultraschallverfahren (1)
- Ultrasound (1)
- Varibale Einstrahlgeometrie (1)
- Verortung (1)
- Welding (1)
- X-ray back scattering (1)
- Zerstörungfreie Analytik (1)
- Zustandsermittlung (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (27)
- 8.0 Abteilungsleitung und andere (18)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (10)
- 6 Materialchemie (5)
- 1 Analytische Chemie; Referenzmaterialien (4)
- 1.4 Prozessanalytik (4)
- 6.1 Oberflächen- und Dünnschichtanalyse (3)
- 6.3 Strukturanalytik (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
- 7 Bauwerkssicherheit (1)
Eingeladener Vortrag
- nein (36)
Machbarkeitsstudie zur Zustandserfassung von Spannbetonschwellen mit dem Ultraschallverfahren
(2024)
Das niederfrequente Ultraschallverfahren zur zerstörungsfreien Zustandserfassung von Stahlbetonkomponenten findet im Bauwesen umfangreiche Anwendung. Multistatische Arrays sind am Markt verfügbar und ausgelegt für die Prüfung großflächiger Betonstrukturen. In einer Machbarkeitsstudie wird überprüft, ob eine Zustandserfassung an schlanken Spannbetonschwellen möglich ist. B70-Schwellen und B90-Weichenschwellen wurden hierfür im Labor, im Schienennetz und während der Wiederaufbereitung mit dem Ultraschallverfahren untersucht. Fokus ist die Detektion von Sickenrisse, Kopfrissen und Treibrissen im Bereich des Schwellenkopfes.
Die rekonstruierten Ultraschalldaten zeigen für intakt-klassifizierte Schwellen ein reproduzierbares Rückwandecho und weitere Reflexionen an den Schwellenaußenkanten. Die Ausprägung der Amplitude variiert je nach Degradation durch Belastung und Verwitterung. Defekt-klassifizierte Schwellen mit z. B. Kopfrissen oder unterseitigen Abplatzungen unterscheiden sich im Signalbild deutlich durch oberflächennahe Reflexionen bzw. verschobene Rückwandechos. Basierend auf den untersuchten Schwellen zeigt die Machbarkeitsstudie, dass eine zerstörungsfreie Zustandserfassung mit Hilfe des Ultraschallverfahrens grundsätzlich möglich ist.
Für die aktive Thermografie als zerstörungsfreie Prüfmethode galt lange Zeit die Faustformel, dass die Auflösung interner Defekte/Inhomogenitäten auf ein Verhältnis von Defekttiefe/Defektgröße ≤ 1 beschränkt ist. Die Ursache hierfür liegt in der diffusiven Natur der Wärmeleitung in Festkörpern. Sogenannte Super-Resolution-Ansätze erlauben seit Kurzem die Überwindung dieser physikalischen Grenze um ein Vielfaches. Damit ergibt sich die attraktive Möglichkeit die Thermografie von einem rein oberflächensensitiven Prüfverfahren hin zu einem Verfahren mit verbesserter Tiefenreichweite zu entwickeln. Wie weit diese Entwicklung getrieben werden kann, ist Gegenstand aktueller Forschung. Wir konnten bereits zeigen, dass diese klassische Einschränkung für ein- und zweidimensionale Defektgeometrien überwunden werden kann, indem das Prüfobjekt mit einzelnen Laserspots sequenziell strukturiert beleuchtet wird und damit anschließend aus den resultierenden Messdaten durch Anwendung photothermischer Super-ResolutionRekonstruktion eine Defektkarte berechnet werden kann, welche eine deutlich verbesserte Trennung einzelner naheliegender Defekte erlaubt. Dieses Verfahren profitiert dabei im Ergebnis stark von der Kombination von sequenzieller räumlich strukturierter Beleuchtung und modernen numerischen Optimierungsverfahren, was jedoch in Summe stark auf Kosten der experimentellen Komplexität geht. Dies führt im Gegensatz zur Anwendung von etablierten thermografischen Standardverfahren mit vollflächiger Beleuchtung zu langen Messzeiten, großen Datensätzen und langwieriger numerischer Auswertung. In dieser Arbeit berichten wir über die Anwendung vollflächig räumlichstrukturierter zweidimensionaler Beleuchtungsmuster, welche es durch den Einsatz modernster Laserprojektortechnik in Verbindung mit einem Hochleistungslaser überhaupt erst erlaubt, eine effiziente Umsetzung von photothermischer Super-ResolutionRekonstruktion auch für größere Prüfflächen zu erreichen.
Der Einsatz von Simulationen mit FEM (Finite Element Method) ermöglicht die die quantitative Beschreibung von Wärmeleitungsprozessen in komplexen Geometrien, bei denen analytische Ansätze nicht angewandt werden können, weil die zugrunde liegenden Vereinfachungen nicht gelten. Bei der genauen Modellierung eines kompletten thermografischen Experiments sieht sich der Modellierer einer ganzen Reihe von technischen und physikalischen Parametern gegenüber, die nicht immer bekannt sind und daher geschätzt werden müssen. Im konkreten Fall wurde ein relativ einfaches Experiment mit einfachen Geometrien betrachtet: ein durch Additive Manufacturing gefertigter Metallblock wurde mit einem Laserpuls homogen erwärmt. Aus dem Zeitverlauf der Oberflächentemperatur an der nicht erwärmten Rückseite des gleichmäßig dicken Blocks sollte die thermische Diffusivität des Volumenmaterials ermittelt werden. Bei dem Versuch, die experimentellen Daten durch eine passende Simulation zu beschreiben, ergab sich zunächst eine deutliche Abweichung: die gemessenen Temperaturen waren generell zu niedrig, was auf einen zusätzlichen Wärmeverlustmechanismus hinwies. Es erwies sich, dass die freie Auflage des Materialblocks auf einem flachen Bolzen zur Probenfixierung bei der Simulation des Experiments zu berücksichtigen ist, um eine gute Übereinstimmung zwischen Experiment und thermischer Simulation zu erzielen. Der Beitrag illustriert damit die Möglichkeiten und Potentiale von FEM-Simulationen bei der quantitativen Bewertung von thermografischen Inspektionen zur zerstörungsfreien Prüfung.
Trash to treasure: recovery of transition metal phosphates for (electro-)catalytical applications
(2022)
Wastewaters containing high concentrations of NH4+, PO43- and transition metals are environmentally harmful and toxic pollutants. At the same time phosphorous and transition metals constitute valuable resources. Here, we report the synthesis routes for Co- and Ni-struvites (NH4MPO4∙6H2O, M = Ni2+, Co2+) out of aqueous solutions resembling synthetic/industrial waste water compositions, and allowing for P, ammonia and metal co-precipitation. Furthermore, the as-obtained struvites were further up-cycled. When heated, these transition metal phosphates (TMPs) demonstrate significant changes in the degree of crystallinity/coordination environment involving a high amount of amorphous phases and importantly develop mesoporosity (Figure 1). In this regard, amorphous and mesoporous TMPs are known to be highly promising (electro-)catalysts.
Amorphous phases do not represent a simple “disordered” crystal but more a complex system with a broad range of compositions and physicochemical properties, which remain mostly unknown. Consequently, we investigated the recrystallization and amorphization process during thermal treatment and a resolved the complex amorphous/crystalline structures (Figure 2). As a proof-of-principle for their applicational use, the as-obtained TMPs demonstrate significant proton conductivity properties similar to apatite-like structures from room to high temperatures (>800°C).
Hence, we have developed a promising recycling route in which environmental harmful contaminants like PO43-, NH4+ and 3d metals would be extracted out of waste waters in the form of precursor raw materials. These raw materials can be then further up-cycled through a simple thermal treatment for their specific application in electrocatalysis.
Mit dem zerstörungsfreien Verfahren der nuklear magnetischen Resonanz (NMR) mit Fokus auf 1H-Protonen lässt sich der Feuchtegehalt in porösen Materialien bestimmen und bei einem vollgesättigten Medium eine Porengrößenverteilung ableiten. Für die Ermittlung der Porengrößenverteilung muss die gemessene T2-Relaxationszeitenverteilung mit dem Parameter Oberflächenrelaxivität (OR) umgerechnet werden. Ist dieser Parameter für das zu untersuchende Medium unbekannt, kann dieser mithilfe von Vergleichsverfahren abgeschätzt werden. Dabei kommen z. B. Gassorption, Quecksilberporosimetrie (MIP), Dünnschliff-Mikroskopie oder µ-Computer-Tomographie (µ-CT) zum Einsatz. Da die verschiedenen Verfahren allerdings unterschiedliche Auflösungsgrenzen aufweisen und auf verschiedenen physikalischen Prinzipien beruhen, können die ermittelten ORs für ein Medium stark variieren. Um ein besseres Verständnis für die OR und die Einflüsse der Vergleichsverfahren zu bekommen, wurden 19 verschiedene Sandsteintypen untersucht. Die OR wurde zum einen basierend auf der spezifischen inneren Oberfläche aus der dynamischen Dampfsorption (DVS) und der Gassorption abgeleitet. Zum anderen wurden die Relaxationszeitenverteilungen durch manuelles Anpassen der OR derart in Porengrößenverteilungen umgerechnet, sodass es eine Übereinstimmung mit den Porengrößenverteilungen aus MIP und/oder µ-CT gibt. Die Umrechnung von Relaxationszeitverteilungen in eine Porengrößenverteilung berücksichtigt dabei sowohl fast- als auch slow-diffusion. Insgesamt ergab sich für die Sandsteine ein breites Spektrum an ORs, bei dem die über die innere spezifische Oberfläche ermittelten ORs andere Größenordnungen aufwiesen (< 10 µm/s), als bei dem Vergleich mit MIP oder µ-CT (bis 600 µm/s). Die mit MIP und µ-CT ermittelten Werten lagen dabei um einen Faktor von 1 bis 30 auseinander. Dieser umfangreiche Datensatz, der vier verschiedene Vergleichsverfahren einbezieht, soll neue Erkenntnisse in der Charakterisierung von porösen Materialien (z. B. bezüglich der Oberflächenrauigkeit) und in der Ursache für die starke Variation der OR ermöglichen. Durch das Berücksichtigen von fast- als auch slow-diffusion, können dabei sogar Daten in eine Porengrößenverteilung umgerechnet werden, bei denen das fast-diffusion-Kriterium nach Brownstein und Tarr nicht erfüllt ist. Außerdem ergibt sich aus der Berücksichtigung des slow-diffusion-Regimes ein neues Verständnis für die obere Auflösungsgrenze von NMR.
The successful shift to NDE 4.0 will not only require developing and embracing new technologies associated with the fourth industrial revolution or becoming an integral part of the overall Industry 4.0, but also developing and adopting new ways of working. It is undoubtful that people will remain in charge of the inspections. However, it is arguable if the current “procedure-following” “level I-III” paradigm can withstand the changes that come along NDE 4.0. With the increased autonomy and interconnectedness expected with NDT 4.0, the majority of traditional NDE tasks will no longer be needed. Instead, different skills, such as that of programming and adapting systems, as well as problem solving, will become vital for the inspections. Therefore, we suggest that a new paradigm is needed—one in which inspector roles and, thus, also the requirements will have to be reinvented. We expect the inspectors to be relieved from the tedious and error prone aspects of the current system and to take responsibility for increasingly complex automated systems and work in closer collaboration with other experts. Thus, we propose that the traditional inspector roles will be transformed into that of the system developer, caretaker and problem solver, each requiring a specific set of skills and assuming different responsibilities. In this talk, we will present the new roles and discuss the challenges that may arise with them.
Typically, the near-eutectic Al-Si alloys consist of highly interconnected three-dimensional network of the eutectic Silicon (Si) and intermetallics embedded into Aluminium (Al) matrix. For further improvement of the mechanical properties of such alloys, often, one single ceramic reinforcement phase, e.g. silicon carbide (SiC) or aluminium oxide (Al2O3) in the form of fibres or particles is added. However, hybrid reinforcements (fibres and particles) can further improve wear resistance and fracture toughness, and additionally, reduce anisotropy of the material. The engineering of metal matrix composites (MMC) for specific application requirements benefits from a comprehensive knowledge of the failure behaviour. Therefore, damage evolution under compression was investigated on:
- pure near-eutectic AlSi12CuMgNi matrix alloy
- type I: matrix reinforced with random-planar oriented Al2O3 short fibres (15 vol.%)
- type II: matrix reinforced with random-planar oriented Al2O3 short fibres (7 vol.%) and additional SiC particles (15 vol.%)
The analysis of damage mechanism was carried out in two rather independent but complementary studies. First, selected sister samples of every material were exposed to quasi-static compression (traverse control). The compression tests were interrupted at different strain levels. Miniature cylinders with a diameter of 1mm were extracted from the pre-strained samples and investigated by synchrotron computed tomography (SX-µCT) with a spatial resolution of about 0.7 µm. For the pure matrix alloy, microcracks are confined to the intermetallic particles and to the eutectic Si, hence no damage was observed in the Aluminium. The composite type II revealed a more effective strain accumulation (less damage) than type I at low plastic strain (up to 5 %), but a more catastrophic damage development due to cracking of the SiC clusters at higher strain levels.
The second approach to study the damage initiation and accumulation in the materials subjected to compressive load was Acoustic Emission (AE) analysis. In this case the in-situ monitoring of the acoustic emission signal was performed during compression tests on specimens with dimension of several mm. For all three material types, AE activity set at 2% strain. Differences in AE behaviour of the three materials was proven based on AE hitrate, signal peak amplitudes as well as weighted peak frequencies (WPF). Future work focuses on combination of AE and SX-µCT aiming for more detailed knowledge on damage mechanism of metal matrix composites.
Nanomaterials bring various benefits and have become a part of our daily lives. However, the risks emerging from nanotechnology need to be minimized and controlled at the regulatory level and therefore, there is a need for nanorisk governance. One of the prerequisites for successful nanorisk governance is the availability of high-quality data on nanomaterials and their impact with the human body and the environment. In recent decades, a countless number of publications and studies on nanomaterials and their properties have been produced due to the fast development of nanotechnology. Despite such a vast amount of data and information, there are certain knowledge gaps hindering an efficient nanorisk governance process. Knowing the state of the available data and information is an important requirement for any decision maker in dealing with risks. In the specific case of nanotechnology, where most of the risks are complex, ambiguous, and uncertain in nature, it is essential to obtain complete data and metadata, to fill knowledge gaps, and to transform the available knowledge into functional knowledge. This can become possible using a novel approach developed within the NANORIGO project (Grant agreement No. 814530) – the Knowledge Readiness Level (KaRL). In analogy to NASA’s Technology Readiness Levels (TRLs), we define KaRLs as a categorization system of data, information, and knowledge which enables transformation of data and information into functional knowledge for nanorisk governance. Our approach goes beyond the technical curation of data and metadata and involves quality and completeness filters, regulatory compliance requirements, nanorisk-related tools, and most importantly, human input (inclusion of all stakeholder groups). With the KaRL approach we also address key issues in nanotechnology such as societal and ethical concerns, circular economies and sustainability, the Green Deal, and the traceability of data, knowledge, and decisions. The KaRL approach could be used for nanorisk governance by a nanorisk governance council (NRGC), which is currently under development by three EU projects (NANORIGO, GOV4NANO, and RISKGONE).
Nanomaterials bring various benefits and have become a part of our daily lives. However, the risks emerging from nanotechnology need to be minimized and controlled at the regulatory level and therefore, there is a need for nanorisk governance. One of the prerequisites for successful nanorisk governance is the availability of high-quality data on nanomaterials and their impact with the human body and the environment. In recent decades, a countless number of publications and studies on nanomaterials and their properties have been produced due to the fast development of nanotechnology. Despite such a vast amount of data and information, there are certain knowledge gaps hindering an efficient nanorisk governance process. Knowing the state of the available data and information is an important requirement for any decision maker in dealing with risks. In the specific case of nanotechnology, where most of the risks are complex, ambiguous, and uncertain in nature, it is essential to obtain complete data and metadata, to fill knowledge gaps, and to transform the available knowledge into functional knowledge. This can become possible using a novel approach developed within the NANORIGO project (Grant agreement No. 814530) – the Knowledge Readiness Level (KaRL). In analogy to NASA’s Technology Readiness Levels (TRLs), we define KaRLs as a categorization system of data, information, and knowledge which enables transformation of data and information into functional knowledge for nanorisk governance. Our approach goes beyond the technical curation of data and metadata and involves quality and completeness filters, regulatory compliance requirements, nanorisk-related tools, and most importantly, human input (inclusion of all stakeholder groups). With the KaRL approach we also address key issues in nanotechnology such as societal and ethical concerns, circular economies and sustainability, the Green Deal, and the traceability of data, knowledge, and decisions. The KaRL approach could be used for nanorisk governance by a nanorisk governance council (NRGC), which is currently under development by three EU projects (NANORIGO, GOV4NANO, and RISKGONE).
Die thermografische ZfP basiert auf der Wechselwirkung von thermischen Wellen mit Inhomogenitäten. Die Ausbreitung von thermischen Wellen von der Wärmequelle zur Inhomogenität und zur Detektionsoberfläche entsprechend der thermischen Diffusionsgleichung führt dazu, dass zwei eng beieinander liegende Defekte fälschlicherweise als ein Defekt im gemessenen Thermogramm erkannt werden können. Um diese räumliche Auflösungsgrenze zu durchbrechen, also eine Super Resolution zu realisieren, kann die Kombination von räumlich strukturierter Erwärmung und numerischen Verfahren des Compressed Sensings verwendet werden.
Für unsere Arbeiten benutzen wir Hochleistungs-Laser im Kilowatt-Bereich um die Probe entweder hochaufgelöst entlang einer Linie (1D) abzurastern oder strukturiert zu erwärmen. Die Verbesserung des räumlichen Auflösungsvermögens zur Defekterkennung hängt dann im klassischen Sinne direkt von der Anzahl der Messungen ab. Mithilfe des Compressed Sensings und Vorkenntnissen über das System ist es jedoch möglich die Anzahl der Messungen zu reduzieren und trotzdem Super Resolution zu erzielen. Wie viele Messungen notwendig sind und wie groß der Auflösungsgewinn gegenüber der konventionellen thermografischen Prüfung mit flächiger Erwärmung ist, hängt von einer Reihe von Messparametern, der Messstrategie, Probeneigenschaften und den verwendeten Rekonstruktionsalgorithmen ab.
Unsere Studien befassen sich mit dem Einfluss der experimentellen Parameter, wie z.B. der Pulslänge der Laserbeleuchtung und der Größe des Laserspots. Weiterhin haben wir uns mit der Wahl der Parameter in der Rekonstruktion auseinandergesetzt, die einen Einfluss auf das im Compressed Sensing zugrundeliegende Minimierungsproblem haben. Für jeden getesteten Parametersatz wurde eine Rekonstruktionsqualität berechnet. Schließlich wurden die Defektrekonstruktionen basierend auf den Parameternsätzen verglichen, sodass eine Parameterwahl für hohe Rekonstruktionsqualitäten mit thermografischer Super Resolution empfohlen werden kann.
Im Europäischen EMPIR-Projekt „NanoXSpot“ (Measurement of the focal spot size of Xray tubes with spot sizes down to 100 nm) werden neue Messmethoden für Brennflecke von Röntgenröhren entwickelt. Teil des Projektes ist die Entwicklung eines zur Lochkameramethode äquivalenten Messverfahrens für kleine Brennflecke. ASTM E 1165-20, Annex A, beschreibt die Bestimmung von Brennfleckgrößen aus Kantenprofilen von Lochaufnahmen für Röntgenröhren mit Brennflecken > 50 μm. Es wurde bereits vorgeschlagen über die Analyse der richtungsabhängigen Kantenunschärfe einer Lochblende und anschließender CT-Rekonstruktion die Intensitätsverteilung des Brennflecks äquivalent zur Lochkameraaufnahme zu berechnen. Die Lochkameramethode, wie in EN 12543-2 und ASTM E 1165-20 beschrieben, ist im unteren Größenbereich für Mikrofokusröhren nicht geeignet, da Pinholes < 10 μm schwer zu fertigen sind und lange Belichtungszeiten erwartet werden. Mit Hilfe exakt gefertigter Lochblenden sowie strukturierter Targets mit konvergierenden Strukturen wird der Bereich mit der Single-Shot-CT-Methode auf die Messung von Mikrofokusröhren, alternativ zur Vermessung von Kanten oder Strichgruppenkörpern, erweitert. Die rekonstruierten Brennfleckformen werden mit Kanten und Lochkameraaufnahmen quantitativ verglichen, um die Messgenauigkeit zu bewerten. Außerdem werden CNR und Messzeit bestimmt, um die Wirtschaftlichkeit der Verfahren zu bewerten.
Thermografische Super Resolution ermöglicht die Auflösung von Defekten/Inhomogenitäten unterhalb des klassischen Limits, welches durch die Diffusionseigenschaften der thermischen Wellenausbreitung bestimmt wird. Basierend auf einer Kombination aus der Anwendung spezieller Abtaststrategien und einer anschließenden numerischen Optimierungsschritt bei der Datenauswertung hat sich die thermografische Super Resolution bereits bei der Detektion von 1D-Defekten gegenüber den Standard-Thermografieverfahren als überlegen erwiesen. In unserer Arbeit erweitern wir die Möglichkeiten der Methode zur effizienten Detektion und Auflösung von Defektquerschnitten mit einer vollständig 2D-strukturierten Erwärmung.
Der experimentelle Ansatz basiert auf einer wiederholten räumlich strukturierten Erwärmung durch einen Hochleistungslaser. In einem zweiten Nachbearbeitungsschritt werden mehrere kohärente Messungen mittels mathematischer Optimierung und unter Ausnutzung der (Joint-) Sparsity der Defekte innerhalb des Prüfkörpers kombiniert. Als Ergebnis kann eine 2D-sparse Defekt-/ Inhomogenitätskarte erhalten werden. Da die Kombination von räumlich strukturierter Erwärmung und anschließender numerischer Kombination mehrerer kohärenter Messungen nicht nur die Auflösung verbessert, sondern auch die Messkomplexität drastisch erhöht, werden verschiedene Scanstrategien untersucht. Abschließend werden die erhaltenen Ergebnisse mit denen konventioneller thermografischer Prüfverfahren verglichen.
Die luftgekoppelte Ultraschallprüfung (ACUT) ist ein vielfach bewährtes zerstörungsfreies Prüfverfahren, welches von vielen Anwendern jedoch nur am Rande oder gar nicht wahrgenommen wird. Insbesondere, die nach wie vor in der Ultraschallausbildung gelehrten Theorien zur wellenlängenabhängigen minimalen detektierbaren Fehlergröße und die vermeintliche Notwendigkeit der Verwendung von Koppelmittel schrecken viele potentielle Anwender davon ab für ihr
Prüfproblem ACUT in Betracht zu ziehen. Des Weiteren wird ACUT häufig nicht als eigenständiges Prüfverfahren erkannt, sodass versucht wird, flüssigkeitsgekoppelte Ultraschallprüfungen ohne Beachtung der Besonderheiten zu ersetzen.
Regulatory decisions require reliable data and knowledge derived from this. Among stakeholders in nanotechnology, however, there is often uncertainty about the quality of data for regulatory purposes. In addition, the general public often finds itself excluded from nanoregulation and policy decisions. This creates uncertainty in the nanotechnology field and also in other branches of technology and leads to concerns among the society.
To address these issues, NANORIGO elaborates a framework to support decision making as well as data, information and knowledge sharing and use. We refer to “reliability” of data and knowledge as a degree of readiness or maturity. According to these criteria we worked out a 9-level scale in analogy to TRL (technology readiness level), the KaRL system (Knowledge, Data and Information Readiness Level). KaRL allows assessment of knowledge readiness for decision making by applying defined quality criteria for each level. It also provides guidance on how to enhance the readiness level by the help of available tools and procedures. KaRL addresses SEIN[1] principles, circular economy and thus involves the public concerns in regulation. A specialized nanorisk governance council (being under development in NANORIGO) is suggested to perform quality check of an actionable document, thus, aiding in consensus on the reliability (maturity) of knowledge for decision making. Moreover, KaRL facilitates traceability of knowledge before its use in decision making. This enables the transparency demanded by all stakeholders.
Monitoring of reinforced concrete structures to ensure their stability and increase their service-life is a crucial element of a modern infrastructural concept. With classical methods of non-destructive testing and inspection, repeated measurements under comparable conditions are difficult to conduct. Therefore, DFG research unit FOR 2825 CoDA researches the assessment of concrete damage using ultrasound coda wave interferometry and embedded sensors. Embedding the sensors into the monitoring target reduces human and non-human factors influencing repeatability. Using Coda Wave Interferometry (CWI), small velocity changes in the material can be detected by comparison of repeated measurements. The technique is sensitive to damaging changes like cracking as well as to reversible influences like material temperature. The understanding of these different influences on the signal is crucial for the analysis of long-term monitoring data to make an educated assessment of the structure and its integrity. With several laboratory experiments in a climate chamber and a long-term experiment recording an annual cycle in a large model on an outdoor test site in Horstwalde close to Berlin, we try to understand the influence of temperature on the CWI results. The results show that the velocity change calculated by CWI does closely follow the trend of concrete temperature. After one year of data recording with the large model being exposed to environmental variations only, the calculated velocity change resembles the annual temperature curve. The data shows a linear dependency between velocity and temperature change in a range of -0.03 percent per °K to -0.06 percent per °K - regardless of specimen size. An approach to remove temperature influence from the yearly cycle recorded in the large-scale experiment using this linear relation is unable to remove high-frequency variations - especially daily influences. Low-pass filtering the data can eliminate these variations while preserving permanent shifts caused by damages. Although we have shown that the influence of temperature on long term monitoring can be removed to a significant extent, there is still an influence of environmental changes remaining in the data. Possible nonlinear effects and influences not related to temperature need to be investigated in the future.
Die zerstörungsfreie Ermittlung der Materialfeuchte in Baustoffen ist für das Bauwesen von großer Bedeutung, denn ein erhöhter Feuchteeintrag kann zu Schimmelbildung, Alkali-Kieselsäure-Reaktionen, Korrosion etc. führen und somit ein hohes Schadenspotential mit sich bringen. Auch wenn zur qualitativen Lokalisierung möglicher Schad- und Risikostellen bereits zahlreiche zerstörungsfreie Verfahren in der Praxis Anwendung finden, besteht ein Mangel an quantitativen Verfahren, die auch bei niedrigen Feuchtegehalten sensitiv sind. Eine Methode zur zerstörungsfreien und quantitativen Bestimmung des Feuchtegehaltes und der effektiven Porosität ist die 1H-Kernspinresonzanzmethode (NMR). Da NMR sensitiv für die molekulare Beweglichkeit von Wasserstoffprotonen ist, lassen sich Informationen über die Bindungsform und -stärke sowie der Umgebung (Porengröße und Mineralzusammensetzung) der Wasserstoffprotonen gewinnen. Obwohl es bereits seit über 20 Jahren mobile NMR-Messeräte gibt, wird NMR heutzutage immer noch weitestgehend im Labor eingesetzt. Dies liegt daran, dass sie aufgrund der verwendeten Permanentmagnete schwer sind und nur äußerst geringe Eindringtiefen ermöglichen. In einer derzeit laufenden Forschungsarbeit wird deshalb ein speziell für Bohrkerne entworfener NMR-Tomograph eingesetzt. Mit seiner minimalen Echozeit von 50 µs lässt sich (abhängig von der Oberflächenrelaxivität) Wasser bis in nanometergroßen Poren erfassen. Um die Sensitivität von NMR bei Teilsättigung zu untersuchen, wurden verschiedene Sandsteinproben in Exsikkatoren mit relativen Luftfeuchten im Bereich von 33 % bis 96 % gelagert. Als Referenzen dienen zum einen das NMR-Signal bei Vollsättigung und zum anderen die Porengrößenverteilung aus Quecksilberporosimetriemessungen (MIP). Um die NMR-Sensitivität zu bewerten, wird die Korrelation der NMR-Amplitude mit den gravimetrisch ermittelten Feuchtegehalten sowie ein Vergleich der Porosität aus NMR und MIP betrachtet. Zu beachten ist in diesem Zusammenhang, dass sowohl die Reduzierung der Wasserfilmdicke als auch die Verkleinerung von Porengrößen zu einer ähnlichen Verkürzung der T2-Relaxationszeit führt. Als Ausblick wird ein Lösungsansatz vorgestellt, bei dem die NMR-Signale mit der Wasserfilmdickenberechnung basierend auf der relativen Luftfeuchte im Material korreliert werden.
Nach Auftreten eines Feuchteschadens in Fußbodenaufbauten sind sowohl die zeitnahe Feststellung als auch Eingrenzung betroffener Bereiche von besonderer Bedeutung. So können erforderliche Renovierungsmaßnahmen effizient geplant und mögliche Folgeschäden vermieden werden. Zur messtechnischen Beantwortung dieser Fragestellungen werden bereits seit vielen Jahren Neutronensonden eingesetzt, welche allerdings keine Tiefenzuordnung des schadensträchtigen Flüssigwassers zulassen. Hierzu müssen mit hohem zeitlichem und finanziellem Aufwand zerstörende Sondierungsbohrungen vorgenommen werden, welche zukünftig durch den parallelen Einsatz des Radarverfahrens vermieden werden könnten. In systematischen Laborstudien wurden gängige Feuchteschäden an häufig anzutreffenden Fußbodenaufbauten simuliert und deren Einfluss auf das Messsignal untersucht. Hierbei kamen Zementund Anhydritestriche, sowie die Dämmmaterialen Styropor, Styrodur, Glaswolle und Perlite-Schüttung mit variierenden Schichtdicken zum Einsatz, um die vielfältigen Konfigurationen der Praxis abzubilden. Für den gewonnenen Datensatz konnten geeignete Signalmerkmale extrahiert werden, welche mithilfe multivariater Datenauswertung eine Klassifizierung des vorliegenden Schadenfalls zulassen. Zum Ende des Forschungsvorhabens steht besonders die Anwendbarkeit der entwickelten Methoden für die Praxis im Fokus. Hierzu wurden Messungen an realen Schadensfällen durchgeführt und deren Ergebnisse mit den Laboruntersuchungen verglichen. Hierbei stellten sich variierende Schichtdicken, sowie vorkommende Fußbodenheizungen und Armierungsgitter als mögliche Fehlerquellen für eine vollständig automatisierte Auswertung heraus.
Im Bereich der Zerstörungsfreien Prüfung (ZfP) im Bauwesen werden eine Vielzahl von Messdaten erfasst. Obwohl Sie als Grundlage für wissenschaftliche Analysen dienen, gibt es noch keine einheitliche Repräsentation der Daten. Eine Analyse verschiedener verteilter Datensätze über unterschiedliche Prüfobjekte hinweg ist daher kaum möglich.
Wir stellen einen Ansatz für ein integriertes Datenmanagement verteilter Datensätze auf Basis von Semantic-Web Technologien vor. Der Ansatz basiert im Kern auf einem mathematischen Modell – der sogenannten Ontologie – welches das Wissen unserer Domäne ZfPBau repräsentiert. Die von uns entwickelte ZfPBau Ontologie wird mit Datenquellen verknüpft und beschreibt so die semantische Bedeutung der Daten. Darüber hinaus fungiert die Ontologie als zentrales Konzept für den Datenbankzugriff. Domänen-fremde Datenquellen können durch die Verknüpfung mit der ZfPBau Ontologie einfach integriert werden und stehen zur generischen Nutzung im Sinne der Digitalisierung direkt zur Verfügung. Basierend auf einer umfangreichen Literaturrecherche, skizzieren wir die Möglichkeiten die sich daraus für die ZfP im Bauwesen ergeben, wie zum Beispiel Messdaten computergestützt zu sortieren, zu analysieren, Zusammenhänge zu erkennen und zu erklären.
Der erwartete Nutzen dieses Ansatzes der Wissensrepräsentation und des Datenzugriffs für die ZfP-Community ist eine Erweiterung des Wissens durch Datenaustausch in der Forschung (Interoperabilität), die wissenschaftliche Verwertung großer existierender Datenquellen mit datenbasierten Verfahren (wie Bilderkennung, Messunsicherheitsberechnungen, Faktoranaylsen, Materialcharackterisierung) und letztlich ein vereinfachter Transfer von ZFP-Daten in Ingenieurmodelle und somit in die Baupraxis.
Ontologien sind bereits Kern vielzähliger intelligenter Systeme wie Building-Information-Modeling oder Forschungsdatenbanken. Der Beitrag gibt einen Überblick über die Werkzeuge die wir derzeit für die Kommunikation mit ihnen schaffen.
In the field of non-destructive testing (NDT) in civil engineering, a large number of measurement data are collected. Although they serve as a basis for scientific analyses, there is still no uniform representation of the data. An analysis of various distributed data sets across different test objects is therefore only possible with high manual effort.
We present a system architecture for an integrated data management of distributed data sets based on Semantic Web technologies. The approach is essentially based on a mathematical model - the so-called ontology - which represents the knowledge of our domain NDT. The ontology developed by us is linked to data sources and thus describes the semantic meaning of the data. Furthermore, the ontology acts as a central concept for database access. Non-domain data sources can be easily integrated by linking them to the NDT construction ontology and are directly available for generic use in the sense of digitization. Based on an extensive literature research, we outline the possibilities that this offers for NDT in civil engineering, such as computer-aided sorting, analysis, recognition and explanation of relationships (explainable AI) for several million measurement data.
The expected benefits of this approach of knowledge representation and data access for the NDT community are an expansion of knowledge through data exchange in research (interoperability), the scientific exploitation of large existing data sources with data-based methods (such as image recognition, measurement uncertainty calculations, factor analysis, material characterization) and finally a simplified exchange of NDT data with engineering models and thus with the construction industry.
Ontologies are already the core of numerous intelligent systems such as building information modeling or research databases. This contribution gives an overview of the range of tools we are currently creating to communicate with them.
X-ray back scatter imaging is rarely applied compared to classical X-ray projection imaging. 20 years ago the company Philips developed “COMSCAN”, a first application case in the aircraft industry, which allowed even a depth resolution using back scatter imaging. The company AS&E in Boston offers back scatter imaging solutions for the security market. Their principle is to scan the object with a highly collimated X-ray needle beam from one side only and detect the backscattered radiation by a large area detector side by side with the collimation wheel. A new prototype is investigated at BAM for application and optimization in non-destructive testing. As modern industrial application field in-situ testing in additive manufacturing is targeted. The accessibility of the printed part during the production process is very limited. This prevent the application of a two sided X-ray inspection or Computed Tomography, were an rotation of the object is required to acquire projections from 360 degrees. An important advantage for the X-ray back scatter technique are also the materials used in additive manufacturing (polymers, ceramics, light metals like Aluminum or Titanium). These materials with lower density and lower Z values give better scatter signals than metals with higher densities and Z values. The back scatter intensity decreases with increasing density and Z value of the material. But the requirements on spatial resolution and contrast sensitivity are more stringent for non-destructive testing of additive manufactured parts compared to the security area. In NDT sizes of indications smaller than 1 mm have to be detected clearly. The investigation of these limits on a stateof-the-art prototype for X-ray back scattering using rotating collimated X-ray needle beams is a part of the BAM project “ProMoAM”. The contribution shows first results of the optimization for NDT and the achieved application limits for several example cases.