BAM Präsentationen
Filtern
Dokumenttyp
- Posterpräsentation (41) (entfernen)
Referierte Publikation
- nein (41)
Schlagworte
- CONSENS (10)
- Online NMR spectroscopy (10)
- Process Monitoring (7)
- Process analytical technology (6)
- Online NMR Spectroscopy (5)
- Feuchte (4)
- Indirect Hard Modeling (4)
- NMR (4)
- Indirect hard modeling (3)
- Process control (3)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (15)
- 8.0 Abteilungsleitung und andere (11)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (6)
- 6 Materialchemie (3)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 6.1 Oberflächen- und Dünnschichtanalyse (1)
- 6.3 Strukturanalytik (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
- 8.4 Akustische und elektromagnetische Verfahren (1)
A robust and sensitive method for the detection of the explosive trinitrotoluene (TNT) was developed. The detection limit was determined to be around 0.5 µg/L. The fast signal response of less than 1 minute shows that this approach is suitable for security and other time-critcal applications. In addition, the very low cross-reactivity highly reduces the number of false-positives in relation to competing techniques, including sniffer dogs. Due to the multianalyte ability of the SAW system, several explosives might be detected in parallel.
Assessment and validation of various flow cell designs for quantitative online NMR spectroscopy
(2017)
Compact nuclear magnetic resonance (NMR) instruments make NMR spectroscopy and relaxometry accessible in industrial and harsh environments for reaction and process control. Robust field integration of NMR systems have to face explosion protection or integration into process control systems with short set-up times. This paves the way for industrial automation in real process environments.
The design of failsafe, temperature and pressure resistant flow through cells along with their NMR-specific requirements is an essential cornerstone to enter industrial production plants and fulfill explosion safety requirements. NMR-specific requirements aim at full quantitative pre-magnetization and acquisition with maximum sensitivity while reducing sample transfer times and dwell-times. All parameters are individually dependent on the applied NMR instrument. Luckily, an increasing number of applications are reported together with an increasing variety of commercial equipment. However, these contributions have to be reviewed thoroughly.
The performance of sample flow cells commonly used in online analytics and especially for low-field NMR spectroscopy was experimentally and theoretically investigated by 1H-NMR experiments and numerical simulations. Here, we demonstrate and discuss an automated test method to determine the critical parameters of flow through cells for quantitative online NMR spectroscopy. The setup is based on randomized setpoints of flow rates in order to reduce temperature related effects. Five flow cells and tubings were assessed and compared for high-field as well as low-field NMR spectrometers.
For reaction monitoring using NMR instruments, in particular, after acquisition of the FID the data needs to be corrected in real-time for common effects using automated methods. When it comes to NMR data evaluation under industrial process conditions, the shape of signals can change drastically due to nonlinear effects. However, the structural and quantitative information is still present but needs to be extracted by applying predictive models. Acquired raw spectra were processed with the following tools:
· Phase correction using the Entropy minimization method
· Baseline correction using a low-order Polynomial fit
· Alignment (icoshift) Pure component models based on Pseudo-Voigt functions can be derived via peak fitting of measured pure components or by the use of spin calculations.
Keramikdurchflusszellen für das industrielle Reaktionsmonitoring mit Niederfeld-NMR-Spektroskopie
(2017)
Derzeit verfügbare Niederfeld-NMR-Spektrometer sind oft für Laborapplikationen konzipiert. Für den Einsatz im industriellen Prozessmonitoring müssen deshalb Anpassungen vorgenommen werden. Ein wichtiger Aspekt ist die Gestaltung der Messzelle. Sie muss über eine hohe thermische-, chemische und vor allem mechanische Beständigkeit verfügen. Hinzu kommt die Besonderheit des NMR-Experiments, das auf die Durchlässigkeit von Radiofrequenzen angewiesen ist. Keramik ist ein in der Hochfeld-NMR-Spektroskopie bewährtes Material das diese Eigenschaften vereint. Um im Prozessmonitoring die Interessen kleiner Bypass-Volumina, großer Durchflussgeschwindigkeit und großes Signal-zu-Rausch-Verhältnis mit der nötigen Vormagnetisierungszeit in Einklang zu bringen, ist eine im Messbereich aufgeweitete Zellgeometrie vorteilhaft. Die Fertigung einer Keramikmesszelle für die Niederfeld-NMR-Spektroskopie für Drücke bis 7 MPa mit dieser besonderen Geometrie wurde mit Hilfe eines modernen additiven Fertigungsverfahrens realisiert.
Quantitative NMR-Messungen an konstant durch das Spektrometer strömenden Flüssigkeiten werden durch eine maximale Durchflussgeschwindigkeit limitiert. Diese wird von vielen Einflussgrößen bestimmt und sollte vor jeder quantitativen Messreihe experimentell für das individuelle System ermittelt werden. Zu diesem Zweck wurde eine automatisierte Laboranordnung konzipiert. Der Vergleich der neuen NMR-Keramikzelle mit bestehenden Messzellen u. a. anhand dieses Parameters untermauert ihre Eignung für das industrielle Prozessmonitoring.
Mit dem zerstörungsfreien Verfahren der nuklear magnetischen Resonanz (NMR) mit Fokus auf 1H-Protonen lässt sich der Feuchtegehalt in porösen Materialien bestimmen und bei einem vollgesättigten Medium eine Porengrößenverteilung ableiten. Für die Ermittlung der Porengrößenverteilung muss die gemessene T2-Relaxationszeitenverteilung mit dem Parameter Oberflächenrelaxivität (OR) umgerechnet werden. Ist dieser Parameter für das zu untersuchende Medium unbekannt, kann dieser mithilfe von Vergleichsverfahren abgeschätzt werden. Dabei kommen z. B. Gassorption, Quecksilberporosimetrie (MIP), Dünnschliff-Mikroskopie oder µ-Computer-Tomographie (µ-CT) zum Einsatz. Da die verschiedenen Verfahren allerdings unterschiedliche Auflösungsgrenzen aufweisen und auf verschiedenen physikalischen Prinzipien beruhen, können die ermittelten ORs für ein Medium stark variieren. Um ein besseres Verständnis für die OR und die Einflüsse der Vergleichsverfahren zu bekommen, wurden 19 verschiedene Sandsteintypen untersucht. Die OR wurde zum einen basierend auf der spezifischen inneren Oberfläche aus der dynamischen Dampfsorption (DVS) und der Gassorption abgeleitet. Zum anderen wurden die Relaxationszeitenverteilungen durch manuelles Anpassen der OR derart in Porengrößenverteilungen umgerechnet, sodass es eine Übereinstimmung mit den Porengrößenverteilungen aus MIP und/oder µ-CT gibt. Die Umrechnung von Relaxationszeitverteilungen in eine Porengrößenverteilung berücksichtigt dabei sowohl fast- als auch slow-diffusion. Insgesamt ergab sich für die Sandsteine ein breites Spektrum an ORs, bei dem die über die innere spezifische Oberfläche ermittelten ORs andere Größenordnungen aufwiesen (< 10 µm/s), als bei dem Vergleich mit MIP oder µ-CT (bis 600 µm/s). Die mit MIP und µ-CT ermittelten Werten lagen dabei um einen Faktor von 1 bis 30 auseinander. Dieser umfangreiche Datensatz, der vier verschiedene Vergleichsverfahren einbezieht, soll neue Erkenntnisse in der Charakterisierung von porösen Materialien (z. B. bezüglich der Oberflächenrauigkeit) und in der Ursache für die starke Variation der OR ermöglichen. Durch das Berücksichtigen von fast- als auch slow-diffusion, können dabei sogar Daten in eine Porengrößenverteilung umgerechnet werden, bei denen das fast-diffusion-Kriterium nach Brownstein und Tarr nicht erfüllt ist. Außerdem ergibt sich aus der Berücksichtigung des slow-diffusion-Regimes ein neues Verständnis für die obere Auflösungsgrenze von NMR.
Die zerstörungsfreie Ermittlung der Materialfeuchte in Baustoffen ist für das Bauwesen von großer Bedeutung, denn ein erhöhter Feuchteeintrag kann zu Schimmelbildung, Alkali-Kieselsäure-Reaktionen, Korrosion etc. führen und somit ein hohes Schadenspotential mit sich bringen. Auch wenn zur qualitativen Lokalisierung möglicher Schad- und Risikostellen bereits zahlreiche zerstörungsfreie Verfahren in der Praxis Anwendung finden, besteht ein Mangel an quantitativen Verfahren, die auch bei niedrigen Feuchtegehalten sensitiv sind. Eine Methode zur zerstörungsfreien und quantitativen Bestimmung des Feuchtegehaltes und der effektiven Porosität ist die 1H-Kernspinresonzanzmethode (NMR). Da NMR sensitiv für die molekulare Beweglichkeit von Wasserstoffprotonen ist, lassen sich Informationen über die Bindungsform und -stärke sowie der Umgebung (Porengröße und Mineralzusammensetzung) der Wasserstoffprotonen gewinnen. Obwohl es bereits seit über 20 Jahren mobile NMR-Messeräte gibt, wird NMR heutzutage immer noch weitestgehend im Labor eingesetzt. Dies liegt daran, dass sie aufgrund der verwendeten Permanentmagnete schwer sind und nur äußerst geringe Eindringtiefen ermöglichen. In einer derzeit laufenden Forschungsarbeit wird deshalb ein speziell für Bohrkerne entworfener NMR-Tomograph eingesetzt. Mit seiner minimalen Echozeit von 50 µs lässt sich (abhängig von der Oberflächenrelaxivität) Wasser bis in nanometergroßen Poren erfassen. Um die Sensitivität von NMR bei Teilsättigung zu untersuchen, wurden verschiedene Sandsteinproben in Exsikkatoren mit relativen Luftfeuchten im Bereich von 33 % bis 96 % gelagert. Als Referenzen dienen zum einen das NMR-Signal bei Vollsättigung und zum anderen die Porengrößenverteilung aus Quecksilberporosimetriemessungen (MIP). Um die NMR-Sensitivität zu bewerten, wird die Korrelation der NMR-Amplitude mit den gravimetrisch ermittelten Feuchtegehalten sowie ein Vergleich der Porosität aus NMR und MIP betrachtet. Zu beachten ist in diesem Zusammenhang, dass sowohl die Reduzierung der Wasserfilmdicke als auch die Verkleinerung von Porengrößen zu einer ähnlichen Verkürzung der T2-Relaxationszeit führt. Als Ausblick wird ein Lösungsansatz vorgestellt, bei dem die NMR-Signale mit der Wasserfilmdickenberechnung basierend auf der relativen Luftfeuchte im Material korreliert werden.
Nuklear magnetische Resonanz (NMR) etabliert sich zunehmend im Bauingenieurwesen als eine alternative Methode zur zerstörungsfreien Feuchtebestimmung in Baustoffen. Schäden, die durch einen zu hohen Anteil an Flüssigwasser auftreten können, sind Ablösungen, Korrosion, Frostschäden, Induktion von Salzkristallisationen, etc. Aufgrund der Sensitivität für 1H-Protonen, ist NMR eine geeignete Methode zur Feuchtedetektion. Dabei kann laut Theorie zwischen frei, chemisch oder physikalisch gebundenem Wasser differenziert werden, während in der Praxis abhängig von der Messtechnik und Probengröße größtenteils nur das freie Wasser detektierbar ist. Mithilfe der NMR Relaxometrie lassen sich nicht nur Relaxationsabklingkurven ermitteln, sondern auch Relaxationszeitenverteilungen, sowie bei Vollsättigung ggf. eine Porengrößenverteilung ableiten. Darüber hinaus lassen sich erste Annahmen über die Entwicklung der Porensättigung bei Teilsättigung der Probe treffen.
Ziel dieser Arbeit war die Untersuchung der zeitlichen Entwicklung der Porensättigung während des natürlichen Trocknungsprozesses (Teilsättigung) sowie die Ermittlung der Porengrößenverteilung an Beispiel von zementgebundenen Estrichen. Für den Versuch wurden zwei zementgebundene Estrichproben nach abgeschlossener Hydratation wieder aufgesättigt. Während des anschließenden natürlichen Trocknungsprozesses wurden regelmäßig NMR-Messungen durchgeführt sowie die Massenentwicklung observiert. Hauptfokus lag auf der zeitlichen und tiefenabhängigen Entwicklung der Relaxationszeitenverteilungen. Bei fortschreitender Trocknung der Proben konnte eine Verschiebung des Maximums der Relaxationszeitenverteilung zu kleineren Zeiten beobachtet werden. Die Ursache liegt zum einen in dem abnehmenden Anteil an freiem Wasser in größeren Poren und zum anderen in dem verhältnismäßig zunehmenden Signalanteil durch Wasser in kleineren Poren.
Durch den Vergleich mit Quecksilberporosimetrie und Gas-Adsorptions-Ergebnissen, konnte aus den NMR-Daten eine unimodale Porengrößenverteilung mit einer dominanten Porengröße von 0,08 bis 0,1 µm und eine effektive Oberflächenrelaxivität von ca. 10 bis 30 µm/s abgeleitet werden.
Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectroscopy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory.
Within the project CONSENS, the continuous production of high-value products in small production scale is advanced by introducing benchtop NMR spectroscopy. CONSENS is a research and innovation project on integrated control and sensing for sustainable operation of flexible intensified processes.
This poster will present the first steps of the process integration of a benchtop NMR instrument for a lithiation process and outlines further fields of activity and potential challenges. Hereby, the following issues are going to be addressed: explosion-proof housing for the spectrometer, automation of signal processing (data pretreatment, evaluation and communication to the control system), flow cells and measuring conditions. Furthermore, first online spectra of the lithiation reaction in batch mode were acquired in lab scale. The reaction was performed in a 25 mL glass reactor with thermal jackets for temperature control of the reaction mixture. The Li-HMDS was dosed stepwise by using a glass syringe. First spectra in the proton and fluorine domain were recorded online using a flowrate of 3.5 mL min–1 and a simple 5 mm polytetrafluoroethylene tube (PTFE) as a flow cell.
Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied. NMR spectroscopy has a high potential for direct loop process control. Compact NMR instruments based on permanent magnets are robust and inexpensive analysers, which feature advantages like low maintenance, ease of use, and cryogen-free operation. Instruments for online NMR measurements equipped with a flow-through cell, possessing a good signal-to-noise-ratio, robustness, and meeting the requirements for integration into industrial plants (i.e., explosion safety and fully automated data analysis) are currently not available off the rack.
Intensified continuous processes are in focus of current research. Flexible (modular) chemical plants can produce different products using the same equipment with short down-times between campaigns and quick introduction of new products to the market. In continuous flow processes online sensor data and tight closed-loop control of the product quality are mandatory. Otherwise there is a huge risk of producing large amounts of out-of-spec (OOS) products. This is addressed in the European Union’s Research Project CONSENS by development and integration of smart sensor modules for process monitoring and control within such modular plant setups.
The presented NMR module is provided in an explosion proof housing with a module size of 57 x 57 x 85 cm and involves a compact 43.5 MHz NMR spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction) and evaluation. Indirect Hard Modeling (IHM) was selected for data analysis of the low-field NMR spectra. A set-up for monitoring continuous reactions in a thermostated 1/8” tubular reactor using automated syringe pumps was used to validate the IHM models by using high-field NMR spectroscopy as analytical reference method.
The departure from the current automation landscape to next generation automation concepts for the process industry has already begun. Smart functions of sensors simplify their use and enable plug-and-play integration, even though they may appear to be more complex at first sight. Monitoring specific information (i.e., “chemical” such as physico-chemical properties, chemical reactions, etc.) is the key to “chemical” process control. Here we introduce our smart online NMR sensor module provided in an explosion proof housing as example.
Due to NMR spectroscopy as an “absolute analytical comparison method”, independent of the matrix, it runs with extremely short set-up times in combination with “modular” spectral models. Such models can simply be built upon pure component NMR spectra within a few hours (i.e., assignment of the NMR signals to the components) instead of tedious calibrations runs. We present a range of approaches for the automated spectra analysis moving from statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations).
Based on concentration measurements of reagents and products by the NMR analyzer a continuous production and direct loop process control were successfully realized for several validation runs in a modular industrial pilot plant and compared to conventional analytical methods (HPLC, near infrared spectroscopy). The NMR analyser was developed for an intensified industrial process funded by the EU’s Horizon 2020 research and innovation programme (“Integrated CONtrol and SENsing”, www.consens-spire.eu).
Monitoring chemical reactions is the key to process control. Today, mainly optical online methods are applied, which are calibration intensive. NMR spectroscopy has a high potential for direct loop process control while cutting the calibration and validation needs to an minimum and thus exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environments for advanced process monitoring and control.
Intensified continuous processes are in focus of current research. Flexible (modular) chemical plants can produce different products using the same equipment with short down-times between campaigns and quick introduction of new products to the market. In continuous flow processes online sensor data and tight closed-loop control of the product quality are mandatory. Data analysis techniques are available but currently mostly used for off-line data analysis to detect the causes of variations in the product quality.
This is addressed within the EU’s Research Project CONSENS by the development and integration of a smart NMR module for process monitoring. The presented NMR module is provided in a mobile explosion proof housing and involves a compact spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction), and evaluation. Such “smart sensors” provide the basis for the future project “Industrie 4.0”, and Industrial Internet of Things (IIoT), along with current requirements to process control, model based control, or soft sensing. The module transforms the acquired online spectra of various technically relevant reactions to either conventional 4‒20 mA signals as well as WiFi based OPC-UA communication protocols, which enables NMR-based advanced process control and funny discussions with plant managers along with automation and safety engineers.
Ultraschall-Echoverfahren an Betonbauteilen mit geneigten Rückwänden - Entwicklung von Testkörpern
(2019)
Mit dem Ultraschall-Echoverfahren können geometrische Abmessungen von Betonbauteilen bestimmt werden. Es hat sich gezeigt, dass die Bauteilrückwand bei der Messung an Massivbrücken häufig nicht planparallel zur Messfläche ausgeführt ist. Es wird erwartet, dass der Einfluss einer Neigung der Rückwand gegenüber der Messfläche auf die Messunsicherheit bei der Dickenbestimmung nicht vernachlässigbar ist. In diesem Beitrag werden die fünf konzipierten Betonprobekörper und ausgewählte Messergebnisse zur Bestimmung dieses Einflusses gezeigt.
Thermografische Super Resolution ermöglicht die Auflösung von Defekten/Inhomogenitäten unterhalb des klassischen Limits, welches durch die Diffusionseigenschaften der thermischen Wellenausbreitung bestimmt wird. Basierend auf einer Kombination aus der Anwendung spezieller Abtaststrategien und einer anschließenden numerischen Optimierungsschritt bei der Datenauswertung hat sich die thermografische Super Resolution bereits bei der Detektion von 1D-Defekten gegenüber den Standard-Thermografieverfahren als überlegen erwiesen. In unserer Arbeit erweitern wir die Möglichkeiten der Methode zur effizienten Detektion und Auflösung von Defektquerschnitten mit einer vollständig 2D-strukturierten Erwärmung.
Der experimentelle Ansatz basiert auf einer wiederholten räumlich strukturierten Erwärmung durch einen Hochleistungslaser. In einem zweiten Nachbearbeitungsschritt werden mehrere kohärente Messungen mittels mathematischer Optimierung und unter Ausnutzung der (Joint-) Sparsity der Defekte innerhalb des Prüfkörpers kombiniert. Als Ergebnis kann eine 2D-sparse Defekt-/ Inhomogenitätskarte erhalten werden. Da die Kombination von räumlich strukturierter Erwärmung und anschließender numerischer Kombination mehrerer kohärenter Messungen nicht nur die Auflösung verbessert, sondern auch die Messkomplexität drastisch erhöht, werden verschiedene Scanstrategien untersucht. Abschließend werden die erhaltenen Ergebnisse mit denen konventioneller thermografischer Prüfverfahren verglichen.
Fortwährend besteht ein wesentlicher Bedarf an Nachrechnungen von bestehenden Brückenbauwerken. Die Zuverlässigkeit der Berechnungsergebnisse hängt insbesondere von der Anzahl und von der Qualität der einbezogenen Informationen ab. Durch die Anwendung von zerstörungsfreien Prüfmethoden können quantitative Informationen gesammelt werden, die für die Beurteilung der Tragwerke sowohl relevant als auch ausreichend genau sind. Die gemessenen Daten können explizit in probabilistische Berechnungsmodelle für die Nachrechnung einer Brücke einfließen. Dadurch wird das Modell sukzessive an die Realität angenähert — in anderen Worten: "zugeschärft". Die Zuverlässigkeit der Ergebnisse der Nachrechnung steigt.
In diesem Posterbeitrag wird ein entwickeltes Konzept für die Verwendung von Messergebnissen (anstelle von deterministischen Informationen und Annahmen) im statischen Nachweis zusammengefasst. Am Fallbeispiel einer Spannbetonbrücke werden die Vorteile des dargestellten Ansatzes aufgezeigt. Die Messgrößen (hier die Positionen der Längsspannglieder) und die Messstrategien können anhand von Sensitivitätsanalysen definiert und die Anforderungen an die Messergebnisse aus der statischen Berechnung spezifiziert werden. Die Auswirkungen
a) der Messunsicherheit auf die Tragwerkszuverlässigkeit sowie
b) von gegenüber den vor den Messungen verfügbaren Informationen abweichenden Messwerten sind am Beispiel der Lokalisierung der Längsspannglieder durch Ultraschall- und Radarmessungen dargestellt.
Feuchte, insbesondere in Form von Flüssigwasser, stellt in Baustoffen ein hohes Schadenspotential dar. Um mit zerstörungsfreier Prüfung mögliche Risikostellen zu lokalisieren und Präventionsmaßnahmen zu ergreifen, sind Kenntnisse über das Porengefüge und Feuchtetransportmechanismen im Baustoff erforderlich. Eine wesentliche Problematik besteht derzeit in der Erfassung und Quantifizierung von Feuchteverteilungen bei Teilsättigung.
Wir verfolgen derzeit einen Ansatz, mittels Nuklear Magnetischer Resonanz (NMR) in Korrelation mit relativen Luftfeuchtmessungen den Flüssigwasseranteil bei Teilsättigung zu ermitteln. Mit Protonen-NMR lassen sich Relaxationszeiten von Wasserstoffprotonen in Abhängigkeit von ihrer Bindungsart und ihrer Umgebung - z. B. Porenstruktur und -größe - erfassen. Allerdings lässt sich bei Materialien mit sehr breiten Porengrößenverteilungen nicht klar differenzieren, ob kurze Relaxationszeiten durch größere teilgesättigte oder kleinere vollgesättigte Poren verursacht werden. Für die Korrelation mit der relativen Luftfeuchte im Baustoff erfolgt zunächst eine künstliche Regulierung im Klimaschrank. Durch einen neuentwickelten Ansatz von Hillerborg lassen sich dann bei jeder Luftfeuchte die adsorbierten Wasserschichtdicken und der Porensättigungsgrad für die vorhandenen Porengrößen berechnen. Mithilfe des berechneten Porensättigungsgrades lässt sich eine genauere Analyse der zeitlichen Entwicklung von Relaxationszeitenverteilungen (insbesondere bei Trocknungs- und Aufsättigungsprozessen) vornehmen. Somit sollen erstmals Aussagen zu kürzeren Relaxationszeiten bei teilgesättigten Porensystemen, die beispielsweise auch eine multimodale Porengrößenverteilung aufweisen, getroffen werden können.
In dieser Arbeit wird die Kombination aus NMR und der relativen Luftfeuchte an sehr porösen Dämmplatten aus Kalziumsilikat, die zur Wärmedämmung sowie der Entgegenwirkung von Schimmelbildung eingesetzt werden, angewendet. Untersucht werden 28 Proben à 6 Gruppen, die von unterschiedlichen Herstellern stammen bzw. unterschiedlich hergestellt wurden.
Nach Auftreten eines Feuchteschadens in Fußbodenaufbauten sind sowohl die zeitnahe Feststellung als auch Eingrenzung betroffener Bereiche von besonderer Bedeutung. So können erforderliche Renovierungsmaßnahmen effizient geplant und mögliche Folgeschäden vermieden werden. Zur messtechnischen Beantwortung dieser Fragestellungen werden bereits seit vielen Jahren Neutronensonden eingesetzt, welche allerdings keine Tiefenzuordnung des schadensträchtigen Flüssigwassers zulassen. Hierzu müssen mit hohem zeitlichem und finanziellem Aufwand zerstörende Sondierungsbohrungen vorgenommen werden, welche zukünftig durch den parallelen Einsatz des Radarverfahrens vermieden werden könnten. In systematischen Laborstudien wurden gängige Feuchteschäden an häufig anzutreffenden Fußbodenaufbauten simuliert und deren Einfluss auf das Messsignal untersucht. Hierbei kamen Zementund Anhydritestriche, sowie die Dämmmaterialen Styropor, Styrodur, Glaswolle und Perlite-Schüttung mit variierenden Schichtdicken zum Einsatz, um die vielfältigen Konfigurationen der Praxis abzubilden. Für den gewonnenen Datensatz konnten geeignete Signalmerkmale extrahiert werden, welche mithilfe multivariater Datenauswertung eine Klassifizierung des vorliegenden Schadenfalls zulassen. Zum Ende des Forschungsvorhabens steht besonders die Anwendbarkeit der entwickelten Methoden für die Praxis im Fokus. Hierzu wurden Messungen an realen Schadensfällen durchgeführt und deren Ergebnisse mit den Laboruntersuchungen verglichen. Hierbei stellten sich variierende Schichtdicken, sowie vorkommende Fußbodenheizungen und Armierungsgitter als mögliche Fehlerquellen für eine vollständig automatisierte Auswertung heraus.
Da derzeit keine zerstörungsfreie Alternative zur Lokalisierung von Leitungswasserschäden in Fußböden existiert, werden in der Regel unter hohem zeitlichen und finanziellen Aufwand Sondierungsbohrungen vorgenommen, um das entnommene Material im Labor thermo-gravimetrisch zu untersuchen. Dabei nehmen Leitungswasserschäden mit rd. 2,6 Milliarden Euro jährlich den deutlich größten Posten bei Gebäudeversicherungen ein. Für derartige Fragestellungen werden seit einigen Jahren Neutronensonden eingesetzt. Mit diesem Verfahren ist es möglich, sich einen Überblick über die Gesamtwassermenge in einem definierten Baustoffvolumen zu verschaffen, jedoch kann flüssiges und chemisch gebundenes Wasser nicht unterschieden werden. Daher werden die Messdaten mit den Ergebnissen der Sondierungsbohrungen kalibriert. So können auch große Flächen wie Industriefußböden in relativ kurzer Zeit größtenteils zerstörungsfrei untersucht werden. Da die integrale Messweise der Neutronensonde allerdings keine Tiefenzuordnung eines gefundenen Feuchteschadens zulässt, muss auch diese Information über die Bohrkerne generiert werden. Die Idee des Projekts ist, durch den parallelen Einsatz des Radarverfahrens in Zukunft auf Sondierungsbohrungen verzichten zu können. Nach der Abgrenzung trockener von feuchten Bereichen über die Neutronensonde, wird das Radarverfahren herangezogen, um typische Schadensfälle zerstörungsfrei zu unterscheiden. In systematischen Laborstudien an modular aufgebauten Referenzprobekörpern untersuchen wir die Nachweisgrenzen und Detektionswahrscheinlichkeiten der beiden Verfahren für verschiedene, häufig anzutreffende Fußbodenaufbauten. Anschließend sollen über Datenfusion und Signalverarbeitung innovative Auswertungsansätze entwickelt werden, welche die Messergebnisse von Neutronensonde und Radar automatisiert zur Gewinnung eines höheren Informationsgehalts und zur Klassifizierung der Schadensfälle kombinieren. Im Rahmen des Projekts wird die erarbeitete Vorgehensweise an real geschädigten Objekten getestet, um die Methode zu etablieren sowie Akzeptanz bei Anwendern und Eigentümern zu schaffen. Könnten durch genauere Schadenseingrenzung die Sanierungskosten um nur 4% gesenkt werden, ergäbe sich in Deutschland eine Kostenreduzierung von ca. 100 Million Euro jährlich.
Signalmerkmale des Radarverfahrens zur Klassifizierung von Feuchteschäden in Fußbodenaufbauten
(2020)
Zur Eingrenzung und Klassifizierung auftretender Feuchteschäden in geschichteten Fußbodenaufbauten wird bereits seit vielen Jahren das Neutronensondenverfahren eingesetzt. Während eine Eingrenzung des Schadens bereits durch die zerstörungsfrei aufgenommenen Messdaten möglich ist, erfordert die Klassifizierung zeit- und kostenintensive Sondierungsbohrungen. Die somit gewonnenen Tiefeninformationen zur Lage des Flüssigwassers tragen maßgeblich zur Planung der erforderlichen Reparaturarbeiten bei, was die Frage nach einer zerstörungsfreien Alternative zur vertikalen Lokalisierung von Feuchte in Fußböden stellt. Das Radarverfahren ist mit seiner hohen Sensitivität für Wasser besonders geeignet und soll künftig zur automatisierten Klassifizierung typischer Schadensfälle beitragen.
In einem laufenden Forschungsvorhaben werden in systematischen Laborstudien gängige Schadensfälle an häufig anzutreffenden Fußbodenaufbauten simuliert und deren Einfluss auf die genannten Verfahren untersucht. Hierbei kommen Zement- und Anhydritestriche, sowie unterschiedliche Dämmmaterialen mit variierenden Schichtdicken zum Einsatz.
Wesentlicher Bestandteil der Auswertung ist die Extraktion signifikanter Signalmerkmale des Radarverfahrens, welche Rückschlüsse auf den Schadensfall und ggf. die Wassermenge zulassen. Die Robustheit gegenüber unterschiedlichsten Aufbauten mit wechselnden Schichtdicken und Materialien steht hierbei besonders im Fokus. Erste Ergebnisse empfehlen die Betrachtung der örtlichen Verteilung bestimmter Signalmerkmale im Radargramm (B-Scan), um eine Klassifizierung der Schadensfälle vornehmen zu können.
Compact nuclear magnetic resonance (NMR) instruments make NMR spectroscopy and relaxometry accessible in industrial and harsh environments for reaction characterization and process control. Robust field integration of NMR systems have to face explosion protection or integration into process control systems with short set-up times. This paves the way for industrial automation in real process environments.
The design of failsafe, temperature and pressure resistant flow through cells along with their NMR-specific requirements is an essential cornerstone to enter industrial production plants and fulfill explosion safety requirements. Additionally, if fast reactions are monitored, suitable mixing devices need to be placed in close vicinity to the measuring volume to mix the reactants properly.
NMR-specific requirements aim at full quantitative pre-magnetization and acquisition with maximum sensitivity while reducing sample transfer times and dwell-times. All parameters are individually dependent on the applied NMR instrument.
Luckily, an increasing number of applications are reported together with an increasing variety of commercial equipment. However, these contributions have to be reviewed thoroughly.
The performance of sample flow cells commonly used in online analytics and especially for low-field NMR spectroscopy was experimentally and theoretically investigated by 1H-NMR experiments and numerical simulations. Especially, the applicability of 3D printed zirconium dioxide for innovative flow cell designs was of interest. Here, we demonstrate and discuss an automated test method to determine the critical parameters of flow through cells for quantitative online NMR spectroscopy. The setup is based on randomized setpoints of flow rates in order to reduce temperature related effects. Five flow cells and tubing were assessed and compared for high-field as well as low-field NMR spectrometers.
For reaction monitoring and process control using NMR instruments, in particular, after acquisition of the FID the data needs to be corrected in real-time for common effects using fast interfaces and automated methods. When it comes to NMR data evaluation under industrial process conditions, the shape of signals can change drastically due to nonlinear effects. Additionally, the multiplet structure becomes more dominant because of the comparably low-field strengths which results in overlapping of multiple signals. However, the structural and quantitative information is still present but needs to be extracted by applying predictive models.
We present a range of approaches for the automated spectra analysis moving from statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modeling). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants, or derivatives and robust automation schemes.