BAM Präsentationen
Filtern
Erscheinungsjahr
Dokumenttyp
- Posterpräsentation (41)
- Vortrag (36)
- Beitrag zu einem Tagungsband (7)
Referierte Publikation
- nein (84)
Schlagworte
- CONSENS (16)
- Online NMR Spectroscopy (14)
- Online NMR spectroscopy (13)
- Process Monitoring (12)
- Indirect Hard Modeling (10)
- Industrie 4.0 (8)
- Prozessanalytik (7)
- Smart Sensors (7)
- Process analytical technology (6)
- Process Analytical Technology (5)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (27)
- 8.0 Abteilungsleitung und andere (18)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (10)
- 6 Materialchemie (5)
- 1 Analytische Chemie; Referenzmaterialien (4)
- 1.4 Prozessanalytik (4)
- 6.1 Oberflächen- und Dünnschichtanalyse (3)
- 6.3 Strukturanalytik (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
- 7 Bauwerkssicherheit (1)
Eingeladener Vortrag
- nein (36)
The departure from the current automation landscape to next generation automation concepts for the process industry has already begun. Smart functions of sensors simplify their use and enable plug-and-play integration, even though they may appear to be more complex at first sight. Monitoring specific information (i.e., “chemical” such as physico-chemical properties, chemical reactions, etc.) is the key to “chemical” process control. Here we introduce our smart online NMR sensor module provided in an explosion proof housing as example, which was developed for an intensified industrial process funded by the EU’s Horizon 2020 research and innovation programme (www.consens-spire.eu). Due to NMR spectroscopy as an “absolute analytical comparison method”, independent of the matrix, it runs with extremely short set-up times in combination with “modular” spectral models. Such models can simply be built upon pure component NMR spectra within a few hours (i.e., assignment of the NMR signals to the components) instead of tedious calibrations runs.
Prozess-Sensoren 4.0 vereinfachen ihre Einbindung über Plug and Play, obwohl sie komplexer werden. Sie bieten Selbstdiagnose, Selbstkalibrierung und erleichterte Parametrierung. Über die Konnektivität ermöglichen die Prozess-Sensoren den Austausch ihrer Informationen als Cyber-physische Systeme mit anderen Prozess-Sensoren und im Netzwerk.
Der Wandel von der aktuellen Automation zum smarten Sensor ist im vollen Gange. Automatisierungstechnik und Informations- und Kommunikationstechnik (IKT) verschmelzen zunehmend. Eine Topologie für smarte Sensoren, die das Zusammenwirken mit daten- und modellbasierte Steuerungen bis hin zur Softsensorik beschreibt gibt es heute jedoch noch nicht. Wir müssen jetzt schnell die Weichen für eine smarte und sichere Kommunikationsarchitektur stellen, um zu einer störungsfreien Kommunikation aller Komponenten auf Basis eines einheitlichen Protokolls zu kommen. Unnötiges Schnickschnack ist nicht erwünscht. Wenn die Prozessindustrie dieses nicht definiert, tun es andere.
Für die weitere Entwicklung von der Ist‐Situation zu einer Industrie-4.0-Welt in der Prozessindustrie werden mehrere Szenarien diskutiert. Diese reichen vom erleichterten Abruf sensorbezogener Daten über zusätzliche Kommunikationskanäle zwischen Sensor und mobilen Endgeräten über vollständig bidirektionale Kommunikation bis hin zur Einbindung der Cloud und des Internets in virtualisierte Umgebungen.
Um zu einer störungsfreien Kommunikation aller Komponenten untereinander zu kommen, muss mindestens ein einheitliches Protokoll her, das alle sprechen und verstehen. Der derzeit greifbarste offengelegte Standard, der moderne Kommunikationsanforderungen erfüllt, ist OPC Unified Architecture (OPC-UA). Viele halten das Sortieren der Kommunikationsstandards für eines der wesentlichen Errungenschaften von Industrie 4.0.
Der Vortrag greift die Anforderungen der Technologie-Roadmap „Prozess-Sensoren 4.0“ auf und zeigt Möglichkeiten zu ihrer Realisierung am Beispiel eines Online-NMR-Analysators, der im Rahmen des EU-Projekts „CONSENS“ (www.consens-spire.eu) entwickelt wurde.
Aktuelle und zukünftige öffentliche Förderung von Industrie 4.0-Projekten sind eine gute Investition. Wegen der hohen Komplexität und Interdisziplinarität gelingt die Umsetzung nur gemeinsam zwischen Anwendern aus der Prozessindustrie, Software- und Geräteherstellern sowie Forschungsgruppen. Anwender sind gefragt, diese neue Technologie durch eine beschleunigte Validierung und Akzeptanz umzusetzen. Sie erhalten die einzigartige Chance, ihre Prozesse und Anlagen wettbewerbsfähig zu halten. Kooperativ betriebenen F&E-Zentren und gemeinsam anerkannten Applikationslaboren kommt dafür eine hohe Bedeutung zu.
Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which are calibration intensive. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environments for advanced process monitoring and control.
Within the European Union’s Research Project CONSENS (Integrated CONtrol and SENsing, www.consens-spire.eu) by development and integration of a smart NMR module for process monitoring was designed and delivers online spectra of various reactions. The presented NMR module is provided in an explosion proof housing of 57 x 57 x 85 cm module size and involves a compact spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction), and evaluation.
For reaction monitoring and process control using NMR instruments after acquisition of the FID the data needs to be corrected in real-time for common effects using fast interfaces and automated methods.
When it comes to NMR data evaluation under industrial process conditions, the shape of signals can change drastically due to nonlinear effects. Additionally, the multiplet structure becomes more dominant because of the comparably low-field strengths which results in overlapping of multiple signals. However, the structural and quantitative information is still present but needs to be extracted by applying predictive models.
We present a range of approaches for the automated spectra analysis moving from statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants, or derivatives and robust automation schemes.
Die Generierung und Erweiterung von Prozessverständnis ist eine Grundvoraussetzung für die Anwendung moderner Konzepte im Kontext von Industrie 4.0, wie z.B. modularisierter und intensivierter Prozesse und Anlagen. Insbesondere die direkte Anbindung von Methoden der Online-Prozessanalytik ermöglicht tiefgehende Einblicke in die tatsächlich ablaufenden Vorgänge innerhalb chemischer und pharmazeutischer Produktionsschritte und der damit einhergehenden Regelungskonzepte.
Während die industrielle Anwendung der Online-Raman-Spektroskopie bereits erfolgreich gezeigt wurde, ist die Niederfeld-NMR-Spektroskopie als Online-Methode für die Prozessindustrie bislang noch nicht zugänglich. Der hohe Informationsgehalt verbunden mit einem Wegfall des Kalibrationsaufwands macht die NMR-Spektroskopie zu einer vielversprechenden Methode für die moderne Prozessautomation mit äußerst kurzen Rüstzeiten und geringem Validierungsbedarf. Diese Vorteile zahlen sich insbesondere für Multi-Purpose-Anlagen sowie für Prozesse mit stark schwankender Rohstoffqualität aus.
Im Rahmen des EU-Projekts CONSENS wurde ein industrietauglicher NMR-Analysator basierend auf einem kommerziell verfügbaren Laborgerät entwickelt. Dies umfasst neben der Anbindung an den Prozess vor allem die Erfüllung von Randbedingungen wie zuverlässige Automatisierung und Explosionsschutz, sowie die Integration in sowohl klassische als auch moderne Kommunikationsstrukturen.
Das Konzept wurde an zwei Beispielen aus den Bereichen der pharmazeutischen sowie der großtechnischen Prozessindustrie erprobt. Als eine Beispielreaktion wurde ein Teilschritt einer kontinuierlichen pharmazeutischen Synthese gewählt (Kopplung der zwei aromatischen Systeme Anilin und o-Fluornitrobenzol unter Verwendung eines Lithiumorganyls). Die Reaktion stellt hohe Anforderungen an die automatisierte Auswertung der erhaltenen Prozess-Spektren, die mit physikalisch motivierter Analyse der NMR-Spektraldaten gelöst wurde. Daneben wurde die Synthese des technisch relevanten Lösungsmittels Tetrahydrofuran mit dem Teilschritt der katalytischen Hydrierung von 2-Butin-1,4-diol als Beispielreaktion ausgewählt, die über ein Zwischenprodukt verläuft und Konkurrenzreaktionen aufweist. Dieses System bietet die Möglichkeit der Kombination unterschiedlicher spektroskopischer und klassischer Prozessinformationen von beispielsweise Druck-, Temperatur- und Durchfluss-Messstellen für die Entwicklung innovativer Regelungskonzepte.
Simple calibration concept of an online NMR module demonstrated in a modularised production plant
(2017)
Monitoring specific information (such as physico-chemical properties, chemical re-actions, etc.) is the key to chemical process control. Within the CONSENS Project, the challenge to adapt a commercially available benchtop NMR spectrometer to the full requirements of an automated chemical production environment was tack-led. The developed online NMR module was provided in an explosion proof housing and involves a compact 43.5 MHz NMR spectrometer together with an acquisition unit, a programmable logic controller for automated triggering, flow con-trol, as well as data communication.
First results of an aromatic coupling reaction in lab scale showed a general feasibil-ity according to the signal information in the acquired NMR spectra even though with a considerable overlap. Due to the comparatively low field strength of the NMR spectrometer multivariate methods had to be considered for the prediction of con-centration profiles based on spectral data. Typically, for industrial application of those methods, e.g. Partial Least Squares Regression (PLS-R) as well as Indirect Hard Modeling, large amount of calibration data is demanded, which must be ac-quired in time consuming lab-scale experiments and offline analytics. When it comes to changes in raw materials (e.g., varying functional groups, additional stabi-lizing agents) calibration experiments and data evaluation models are developed again. Here we present an approach of automated data analysis tools for low field NMR spectra with minimal calibration effort. The algorithms are based on Indirect Hard Modeling, whereby each component in each mixture spectra can be rep-resented by several flexible peak functions (pure component models). This means, that only pure component NMR spectra are needed to generate a first evaluation model. The flexibility of peak functions in the spectral model can be adjusted via constraints of peak parameters. The area of any pure component model can either be converted to concentrations based on a one-point calibration on raw material concentration or even neat solvent signals. In several cases it has been shown, the IHM works almost independently of the matrix of the real samples. Such a calibration can be repeated daily in the beginning of each process run with minimal time effort. Moreover, additional pure components can be added to the model or even substitut-ed while keeping the previously adjusted peak function constraints. The proposed method exhibited good agreement of resulting concentration data from low field NMR spectra, when compared to an online high field NMR spectrometer as refer-ence instrument.
Keramikdurchflusszellen für das industrielle Reaktionsmonitoring mit Niederfeld-NMR-Spektroskopie
(2017)
Derzeit verfügbare Niederfeld-NMR-Spektrometer sind oft für Laborapplikationen konzipiert. Für den Einsatz im industriellen Prozessmonitoring müssen deshalb Anpassungen vorgenommen werden. Ein wichtiger Aspekt ist die Gestaltung der Messzelle. Sie muss über eine hohe thermische-, chemische und vor allem mechanische Beständigkeit verfügen. Hinzu kommt die Besonderheit des NMR-Experiments, das auf die Durchlässigkeit von Radiofrequenzen angewiesen ist. Keramik ist ein in der Hochfeld-NMR-Spektroskopie bewährtes Material das diese Eigenschaften vereint. Um im Prozessmonitoring die Interessen kleiner Bypass-Volumina, großer Durchflussgeschwindigkeit und großes Signal-zu-Rausch-Verhältnis mit der nötigen Vormagnetisierungszeit in Einklang zu bringen, ist eine im Messbereich aufgeweitete Zellgeometrie vorteilhaft. Die Fertigung einer Keramikmesszelle für die Niederfeld-NMR-Spektroskopie für Drücke bis 7 MPa mit dieser besonderen Geometrie wurde mit Hilfe eines modernen additiven Fertigungsverfahrens realisiert.
Quantitative NMR-Messungen an konstant durch das Spektrometer strömenden Flüssigkeiten werden durch eine maximale Durchflussgeschwindigkeit limitiert. Diese wird von vielen Einflussgrößen bestimmt und sollte vor jeder quantitativen Messreihe experimentell für das individuelle System ermittelt werden. Zu diesem Zweck wurde eine automatisierte Laboranordnung konzipiert. Der Vergleich der neuen NMR-Keramikzelle mit bestehenden Messzellen u. a. anhand dieses Parameters untermauert ihre Eignung für das industrielle Prozessmonitoring.
Monitoring chemical reactions is the key to process control. Today, mainly optical online methods are applied, which are calibration intensive. NMR spectroscopy has a high potential for direct loop process control while cutting the calibration and validation needs to an minimum and thus exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environments for advanced process monitoring and control.
Intensified continuous processes are in focus of current research. Flexible (modular) chemical plants can produce different products using the same equipment with short down-times between campaigns and quick introduction of new products to the market. In continuous flow processes online sensor data and tight closed-loop control of the product quality are mandatory. Data analysis techniques are available but currently mostly used for off-line data analysis to detect the causes of variations in the product quality.
This is addressed within the EU’s Research Project CONSENS by the development and integration of a smart NMR module for process monitoring. The presented NMR module is provided in a mobile explosion proof housing and involves a compact spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction), and evaluation. Such “smart sensors” provide the basis for the future project “Industrie 4.0”, and Industrial Internet of Things (IIoT), along with current requirements to process control, model based control, or soft sensing. The module transforms the acquired online spectra of various technically relevant reactions to either conventional 4‒20 mA signals as well as WiFi based OPC-UA communication protocols, which enables NMR-based advanced process control and funny discussions with plant managers along with automation and safety engineers.
Assessment and validation of various flow cell designs for quantitative online NMR spectroscopy
(2017)
Compact nuclear magnetic resonance (NMR) instruments make NMR spectroscopy and relaxometry accessible in industrial and harsh environments for reaction and process control. Robust field integration of NMR systems have to face explosion protection or integration into process control systems with short set-up times. This paves the way for industrial automation in real process environments.
The design of failsafe, temperature and pressure resistant flow through cells along with their NMR-specific requirements is an essential cornerstone to enter industrial production plants and fulfill explosion safety requirements. NMR-specific requirements aim at full quantitative pre-magnetization and acquisition with maximum sensitivity while reducing sample transfer times and dwell-times. All parameters are individually dependent on the applied NMR instrument. Luckily, an increasing number of applications are reported together with an increasing variety of commercial equipment. However, these contributions have to be reviewed thoroughly.
The performance of sample flow cells commonly used in online analytics and especially for low-field NMR spectroscopy was experimentally and theoretically investigated by 1H-NMR experiments and numerical simulations. Here, we demonstrate and discuss an automated test method to determine the critical parameters of flow through cells for quantitative online NMR spectroscopy. The setup is based on randomized setpoints of flow rates in order to reduce temperature related effects. Five flow cells and tubings were assessed and compared for high-field as well as low-field NMR spectrometers.
For reaction monitoring and process control using NMR instruments, in particular, after acquisition of the FID the data needs to be corrected in real-time for common effects using fast interfaces and automated methods. When it comes to NMR data evaluation under industrial process conditions, the shape of signals can change drastically due to nonlinear effects. Additionally, the multiplet structure becomes more dominant because of the comparably low-field strengths which results in overlapping of multiple signals. However, the structural and quantitative information is still present but needs to be extracted by applying predictive models.
We present a range of approaches for the automated spectra analysis moving from statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modeling). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants, or derivatives and robust automation schemes.
The departure from the current automation landscape to next generation automation concepts for the process industry has already begun. Smart functions of sensors will simplify their use and enable plug-and-play integration, even though they may appear to be more complex at first sight. This is particularly important for concepts like self-diagnostics, self-calibration and self-configuration/parameterization. Intelligent field devices as parts of digital field networks, Inter-net Protocol (IP)-based connectivity and web interfaces, as well as advanced data analysis soft-ware will provide the basis for future projects like Industrie 4.0, Factory of the Future, or Industrial Internet of Things (IIoT). The talk summarizes the currently discussed general requirements for process sensors 4.0 and introduces an online NMR sensor as example. This sensor was developed to provide integrated control and sensing for sustainable operation of flexible intensified processes (CONSENS) funded by the European Union’s Horizon 2020 research and innovation programme.