Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (2145)
- Beitrag zu einem Tagungsband (390)
- Forschungsbericht (19)
- Beitrag zu einem Sammelband (10)
- Buchkapitel (9)
- Sonstiges (8)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Corrigendum (2)
- Dissertation (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (2350)
- Deutsch (233)
- Mehrsprachig (3)
- Portugiesisch (1)
Schlagworte
- Additive manufacturing (73)
- Fluorescence (58)
- Concrete (48)
- Nanoparticles (48)
- SAXS (46)
- Ultrasound (38)
- Corrosion (37)
- MALDI-TOF MS (37)
- Quantum yield (36)
- Non-destructive testing (34)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (462)
- 6 Materialchemie (459)
- 1 Analytische Chemie; Referenzmaterialien (367)
- 7 Bauwerkssicherheit (237)
- 5 Werkstofftechnik (226)
- 9 Komponentensicherheit (220)
- 4 Material und Umwelt (202)
- 6.3 Strukturanalytik (180)
- 8.5 Röntgenbildgebung (142)
- 6.1 Oberflächen- und Dünnschichtanalyse (104)
Paper des Monats
- ja (72)
In this work, we present a novel approach to photothermal super resolution based thermographic resolution of internal defects using two-dimensional pixel pattern-based active photothermal laser heating in conjunction with subsequent numerical reconstruction to achieve a high-resolution reconstruction of internal defect structures. With the proposed adoption of pixelated patterns generated using laser coupled high-power DLP projector technology the complexity for achieving true two-dimensional super resolution can be dramatically reduced taking a crucial step forward towards widespread practical viability. Furthermore, based on the latest developments in high-power DLP projectors, we present their first application for structured pulsed thermographic inspection of macroscopic metal samples. In addition, a forward solution to the underlying inverse problem is proposed along with an appropriate heuristic to find the regularization parameters necessary for the numerical inversion in a laboratory setting. This allows the generation of synthetic measurement data, opening the door for the application of machine learning based methods for future improvements towards full automation of the method. Finally, the proposed method is experimentally validated and shown to outperform several established conventional thermographic testing techniques while conservatively improving the required measurement times by a factor of 8 compared to currently available photothermal super resolution techniques.
Episodic failures of ice-dammed lakes have produced some of the largest floods in history, with disastrous consequences for communities in high mountains. Yet, estimating changes in the activity of ice-dam failures through time remains controversial because of inconsistent regional flood databases. Here, by collating 1,569 ice-dam failures in six major mountain regions, we systematically assess trends in peak discharge, volume, annual timing and source elevation between 1900 and 2021. We show that extreme peak flows and volumes (10 per cent highest) have declined by about an order of magnitude over this period in five of the six regions, whereas median flood discharges have fallen less or have remained unchanged.
Ice-dam floods worldwide today originate at higher elevations and happen about six weeks earlier in the year than in 1900. Individual ice-dammed lakes with repeated outbursts show similar negative trends in magnitude and earlier occurrence, although with only moderate correlation to glacier thinning8. We anticipate that ice dams will continue to fail in the near future, even as glaciers thin and recede. Yet widespread deglaciation, projected for nearly all regions by the end of the twenty-first century9, may bring most outburst activity to a halt.
Energy efficient products often have a higher purchase price than less efficient alternatives. However, the life cycle costs are often lower due to the lower operating costs. From a purely economic point of view, efficient appliances are not only more ecological but often also more economical and, accordingly, should be purchased more frequently than less efficient appliances. However, this is not always the case. Information deficits are one of the major reasons of this discrepancy: the purchase price is visible during the purchasing process, but the follow-up costs are not, at least not in their exact amount. The EU Energy Label can be considered as a solution to close this gap. During the past decades, there has been a discussion on whether it would be better to communicate the monetary costs associated with energy consumption, since their calculation by the consumer is difficult or needs a high level of cognitive effort.
In this study, experiments and field studies on a total of 19 product groups were evaluated with regard to the question of whether the indication of costs instead of physical units affects the decision-making process of the consumer. It has been assessed under which circumstances it might positively influence the purchase decision of the customer, i.e. helping him or her to arrive at a more “energy efficient” decision. Overall, the results indicate that monetary claims possibly exceed the effect of claims on a physical basis when the costs or the differences between the alternatives available seem “relevant” to the consumer.
Recently, the photothermal determination of the thermophysical properties of concrete under lab conditions was reported. Their values are mainly needed to look at the energy consumption of buildings. Additionally, changes in their values in relation to the initial state might also be a good indicator for material quality or for moisture. The present contribution explains the photothermal method in a more general way to indicate the potential for on-site application. Secondly, a special application case is regarded: the detection of moisture in concrete. Two concrete samples were soaked with water, followed by a drying period, to obtain different levels of water penetration. The water contents were determined by weighing, and the photothermal response was measured. The results show a large influence on the measured temperature transients, which is larger than expected from the original simple model. They clearly provide two points: the photothermal method is suited to detect moisture in concrete, but the magnitude of the actual measurement effect is not yet understood.
Comprehensive evaluation of peptide de novo sequencing tools for monoclonal antibody assembly
(2023)
Monoclonal antibodies are biotechnologically produced proteins with various applications in research, therapeutics and diagnostics. Their ability to recognize and bind to specific molecule structures makes them essential research tools and therapeutic agents. Sequence information of antibodies is helpful for understanding antibody–antigen interactions and ensuring their affinity and specificity. De novo protein sequencing based on mass spectrometry is a valuable method to obtain the amino acid sequence of peptides and proteins without a priori knowledge. In this study, we evaluated six recently developed de novo peptide sequencing algorithms (Novor, pNovo 3, DeepNovo, SMSNet, PointNovo and Casanovo), which were not specifically designed for antibody data. We validated their ability to identify and assemble antibody sequences on three multi-enzymatic data sets. The deep learning-based tools Casanovo and PointNovo showed an increased peptide recall across different enzymes and data sets compared with spectrum-graph-based approaches. We evaluated different error types of de novo peptide sequencing tools and their performance for different numbers of missing cleavage sites, noisy spectra and peptides of various lengths. We achieved a sequence coverage of 97.69–99.53% on the light chains of three different antibody data sets using the de Bruijn assembler ALPS and the predictions from Casanovo. However, low sequence coverage and accuracy on the heavy chains demonstrate that complete de novo protein sequencing remains a challenging issue in proteomics that requires improved de novo error correction, alternative digestion strategies and hybrid approaches such as homology search to achieve high accuracy on long protein sequences.
What is meant by ‘Micro Non-Destructive Testing and Evaluation’? This was the central subject of debate in this Special Issue.
At present, sub-millimeter-size components or even assemblies are pervading the industrial and scientific world. Classic examples are electronic devices and watches (as well as parts thereof), but recent examples encompass additively manufactured lattice structures, stents, or other microparts. Moreover, most assemblies contain micro-components. Testing such components or their miniaturized parts would fit well within the topic of micro non-destructive testing and evaluation.
In all cases, performance and integrity testing, quality control, and dimensional tolerances need to be measured at the sub-millimeter level (ideally with a spatial resolution of about a micron); most of the time, such features and components are embedded in much larger assemblies, which also need to be taken into account. The solution to this dilemma (i.e. measuring large parts with high resolution) depends on the part and on the problem under consideration.
Another possible definition of micro non-destructive testing and evaluation can relate to the characterization of micro-features (e.g., the microstructure) in much larger specimens, such as damage in concrete cores or porosity in additively manufactured components. A further aspect is the use of microscopic probes to evaluate macroscopic properties. This is the case, for instance but not at all exclusively, in the use of diffraction techniques to determine macroscopic stress.
The splits between testing and characterization at the micro-level (or of micro parts) from one side and handling of macroscopic assemblies on the other represent a great challenge for many fields of materials characterization. On top of that, including the use of microscopic methods to test integrity would add a further level of complexity.
Imaging, mechanical testing, non-destructive testing, measurement of properties, structural health monitoring, and dimensional metrology all need to be re-defined if we want to cope with the multi-faceted topic of micro non-destructive testing and evaluation.
The challenge has already been accepted by the scientific and engineering communities for a while but is still far from being universally tackled. This Special Issue yields an interesting answer to the questions posed above. It presents the progress made and the different aspects of the challenge as well as at indicates the paths for the future of NDT&E.
A phase-sensitive optical time domain reflectometer based on coherent heterodyne detection of geometric phase in the beat signal of light, is reported for the first time to our knowledge. The use of the geometric phase to extract strain makes it immune to polarisation diversity fading. This is because a polarisation mismatch between the interfering beams is not a hindrance to its measurement. The geometric phase is calculated using the amplitude of the beat signal and individual beam intensities without any need for phase unwrapping. It is measured per beat period and can be equated with the traditionally measured dynamic phase with appropriate scaling. The results show that the system based on the geometric phase successfully measures strain, free from polarisation mismatch fading and phase unwrapping errors, providing a completely novel solution to these problems.
Melting is well understood in terms of the Lindemann criterion, which
essentially states that crystalline materials melt when the thermal vibrationsof their atoms become so vigorous that they shake themselves free of the binding forces. This picture does not necessarily have to hold for glasses, where the nature of the solid–liquid cross-over is highly debated. The Lindemann criterion implies that the thermal expansion coefficients of crystals are inversely proportional to their melting temperatures. Here we find that, in contrast, the thermal expansion coefficient of glasses decreases more strongly with increasing glass temperature, which marks the liquid–solid cross-over in this material class. However, this proportionality returns when the thermal expansion coefficient is scaled by the fragility, a measure of particle cooperativity. Therefore, for a glass to become liquid, it is not sufficient to simply overcome the interparticle binding energies.
Instead, more energy must be invested to break up the typical cooperative particle network that is common to glassy materials. The thermal expansion coefficient of the liquid phase reveals similar anomalous behaviour and is universally enhanced by a constant factor of approximately 3. These universalities allow the estimation of glass temperatures from thermal expansion and vice versa.
Pseudomonas aeruginosa is an opportunistic pathogen of considerable medical importance, owing to its pronounced antibiotic tolerance and association with cystic fibrosis and other life-threatening diseases. The aim of this study was to highlight the genes responsible for P. aeruginosa biofilm tolerance to antibiotics and thereby identify potential new targets for the development of drugs against biofilm-related infections. By developing a novel screening approach and utilizing a public P. aeruginosa transposon insertion library, several biofilm-relevant genes were identified. The Pf phage gene (PA0720) and flagellin gene (fliC) conferred biofilm-specific tolerance to gentamicin. Compared with the reference biofilms, the biofilms formed by PA0720 and fliC mutants were completely eliminated with a 4-fold-lower gentamicin concentration. Furthermore, the mreC, pprB, coxC, and PA3785 genes were demonstrated to play major roles in enhancing biofilm tolerance to gentamicin. The analysis of biofilm-relevant genes performed in this study provides important novel insights into the understanding of P. aeruginosa antibiotic tolerance, which will facilitate the detection of antibiotic resistance and the development of antibiofilm strategies against P. aeruginosa.
Chemical modification by peroxynitrite enhances TLR4 activation of the grass pollen allergen Phl p 5
(2023)
The chemical modification of aeroallergens by reactive oxygen and nitrogen species (ROS/RNS) may contribute to the growing prevalence of respiratory allergies in industrialized countries. Post-translational modifications can alter the immunological properties of proteins, but the underlying mechanisms and effects are not well understood. In this study, we investigate the Toll-like receptor 4 (TLR4) activation of the major birch and grass pollen allergens Bet v 1 and Phl p 5, and how the physiological oxidant peroxynitrite (ONOO–) changes the TLR4 activation through protein nitration and the formation of protein dimers and higher oligomers. Of the two allergens, Bet v 1 exhibited no TLR4 activation, but we found TLR4 activation of Phl p 5, which increased after modification with ONOO– and may play a role in the sensitization against this grass pollen allergen. We attribute the TLR4 activation mainly to the two-domain structure of Phl p 5 which may promote TLR4 dimerization and activation. The enhanced TLR4 signaling of the modified allergen indicates that the ONOO–-induced modifications affect relevant protein-receptor interactions. This may lead to increased sensitization to the grass pollen allergen and thus contribute to the increasing prevalence of allergies in the Anthropocene, the present era of globally pervasive anthropogenic influence on the environment.