Wissenschaftliche Artikel der BAM
Filtern
Dokumenttyp
- Zeitschriftenartikel (346)
- Sonstiges (3)
- Beitrag zu einem Tagungsband (1)
- Corrigendum (1)
Sprache
- Englisch (351) (entfernen)
Schlagworte
- Fluorescence (53)
- Quantum yield (35)
- Sensor (25)
- Lifetime (21)
- Quality assurance (20)
- Dye (18)
- Photophysics (18)
- Nano (16)
- Synthesis (13)
- Cancer (12)
- Magnetic resonance imaging (12)
- NIR (12)
- Photoluminescence (12)
- Imaging (11)
- Immunoassay (10)
- Lanthanide (10)
- Method (10)
- Nanomaterial (10)
- Nanoparticle (10)
- Particle (9)
- Quantum dots (9)
- Electrochemistry (8)
- ICP-MS (8)
- Mass spectrometry (8)
- Mechanism (8)
- Molecularly imprinted polymers (8)
- Nanoparticles (8)
- Reference material (8)
- ELISA (7)
- Energy transfer (7)
- Raman spectroscopy (7)
- Soil (7)
- Affinity chromatography (6)
- Contrast agent (6)
- Gadolinium (6)
- Luminescence (6)
- MRI (6)
- Mass Spectrometry (6)
- Multiplexing (6)
- Mycotoxins (6)
- Optical probe (6)
- PH (6)
- Surface chemistry (6)
- Traceability (6)
- Upconversion nanoparticle (6)
- Core-shell particles (5)
- Cr(III) (5)
- Flow cytometry (5)
- Laser ablation (5)
- Ligand (5)
- Microscopy (5)
- Raman microspectroscopy (5)
- Single particle (5)
- Aggregation (4)
- Analytical Chemistry (4)
- Brightness (4)
- Calibration (4)
- Cement (4)
- Industry 4.0 (4)
- Interlaboratory comparison (4)
- LA-ICP-MS (4)
- LC-MS/MS (4)
- LIBS (4)
- Lab-on-a-chip (4)
- Metabolomics (4)
- Nitrotyrosine (4)
- Polymer (4)
- Quantitative spectroscopy (4)
- Reproducibility (4)
- SWIR (4)
- Signal enhancement (4)
- XPS (4)
- XRF (4)
- Air pollution (3)
- Allergy (3)
- Antibiotics (3)
- BODIPY (3)
- Bead (3)
- Biosensing (3)
- Biosensor (3)
- Bisphenol A (3)
- Brain (3)
- Coating (3)
- Complex (3)
- Copper (3)
- Corrosion (3)
- Crystal (3)
- DNA origami (3)
- Ergot alkaloids (3)
- Excitation power density (3)
- Extracellular matrix (3)
- Food (3)
- Food analysis (3)
- Gadofosveset (3)
- Gas chromatography (3)
- General Medicine (3)
- HRMS (3)
- High-resolution mass spectrometry (3)
- Human serum (3)
- Hybridoma (3)
- Hydrolysis (3)
- Immunosensor (3)
- Iron oxide (3)
- Isotope dilution (3)
- Isotope ratio (3)
- MOF (3)
- Mass Spectroscopy (3)
- Mechanochemistry (3)
- Metrology (3)
- Microfluidics (3)
- Molecular imaging (3)
- Molecular imprinting (3)
- Monoclonal antibody (3)
- Mycotoxin (3)
- NMR (3)
- Nitration (3)
- Optical spectroscopy (3)
- PFAS (3)
- Pollution (3)
- Probe (3)
- Process Industry (3)
- Quantification (3)
- Raman (3)
- Reference materials (3)
- Screening (3)
- Sensitization (3)
- Spectroscopy (3)
- Switch (3)
- Transformation products (3)
- Tyrosine (3)
- Uncertainty (3)
- Upconversion (3)
- AAS (2)
- Absolute isotope ratio (2)
- Adsorption (2)
- Aggregation induced emission (2)
- Amorphous carbon (2)
- Amperometry (2)
- Antibodies (2)
- Antibody (2)
- Antikörper (2)
- Aromatic amino acid analysis (2)
- Atherosclerosis (2)
- Bacteria (2)
- Barcoding (2)
- Bead-based assay (2)
- Benz[a]anthracene (BaA) (2)
- Benzo[a]pyrene (BaP) (2)
- Biochemistry (2)
- Biocides (2)
- Bioconjugation (2)
- CONSENS (2)
- Cell proliferation (2)
- Certified reference material (2)
- Charge transfer (2)
- Chromatography (2)
- Comparability (2)
- Core−shell particles (2)
- Cuprorivaite (2)
- Cytotoxicity (2)
- Degradation (2)
- Delta scale (2)
- Derivatization (2)
- Diagnosis (2)
- Diagnostics (2)
- Digitalisation (2)
- Dimerization (2)
- Dityrosine (2)
- Documentation (2)
- Egyptian blue (2)
- Electron microscopy (2)
- Emission spectroscopy (2)
- Endocrine disruptor (2)
- Endokrine Disruptoren (2)
- Enhancement (2)
- Environmental Chemistry (2)
- Exocytosis (2)
- Fatty acid metabolism (2)
- Fertilizer (2)
- Ferumoxytol (2)
- Fluoride (2)
- Gas chromatography (GC) (2)
- General Earth and Planetary Sciences (2)
- Glyphosate (2)
- Gold nanoparticles (2)
- HPLC (2)
- HPLC-MS/MS (2)
- HTS (2)
- Health, Toxicology and Mutagenesis (2)
- Heart failure (2)
- Hydrazinolysis (2)
- ICP-OES (2)
- IgG (2)
- Immunoaffinity extraction (2)
- Immunocapture (2)
- Immunoglobulins (2)
- Indium phosphide (2)
- Indoor air (2)
- Inflammation (2)
- Iron (2)
- Isotope (2)
- Isotope dilution (ID) (2)
- Isotope ratios (2)
- LIF (2)
- Label (2)
- Lanthanides (2)
- Lateral flow assay (2)
- Life sciences (2)
- Limit of detection (2)
- Lipidomic profile (2)
- Liquid chromatography (LC) (2)
- Lithium (2)
- MALDI (2)
- MALDI-TOF MS (2)
- MC-ICP-MS (2)
- Magnetic beads (2)
- Mass spectrometry (MS) (2)
- Measurement uncertainty (2)
- Mercury (2)
- Mesoporous materials (2)
- Metabolic stress (2)
- Method development (2)
- Microbeads (2)
- Mikroplastik (2)
- Modelling (2)
- Modular Production (2)
- Molecularly Imprinted Polymers (2)
- Monoclonal Antibodies (2)
- Monolithic column (2)
- Nanomaterials (2)
- Nickel (2)
- Nitrogen oxides (2)
- Nontarget analysis (2)
- Open Science (2)
- Optical detection (2)
- Origami (2)
- Oxygen (2)
- Ozone (2)
- Passivation (2)
- Peptide (2)
- Peptide library (2)
- Ph (2)
- Phenylalanine (2)
- Phosphorylated peptides (2)
- Photodegradation (2)
- Polycyclic aromatic hydrocarbon (PAH) (2)
- Process Analytical Technology (2)
- Production (2)
- Prostate cancer (2)
- Protein (2)
- Protein A (2)
- Protein nitration (2)
- Quality Control (2)
- Quality control (2)
- Quantum dot (2)
- Real-time process monitoring (2)
- Regeneration (2)
- SPR (2)
- Sapphire (2)
- Self-assembly (2)
- Sensors (2)
- Sequence coverage (2)
- Sewage sludge (2)
- Shell (2)
- Sialic acid (2)
- Single molecule (2)
- Software (2)
- Solid state NMR (2)
- Sr isotopes (2)
- Standardization (2)
- Standards (2)
- Surface (2)
- Synthetic peptides (2)
- Sythesis (2)
- Test strips (2)
- Teststreifen (2)
- Theory (2)
- Thermal anhydrite (2)
- Thermal desorption (2)
- Toxicity (2)
- Transformation product (2)
- Triple isotope fractionation (2)
- Triplet-triplet annihilation (2)
- Tumor (2)
- Tumor metabolism (2)
- Ultrafine particles (2)
- Upconversion nanoparticles (2)
- Uptake studies (2)
- Validation (2)
- Water analysis (2)
- Yb(III) complex (2)
- ZIF (2)
- ZIF-8 (2)
- 1-indanol (1)
- 150th anniversary (1)
- 150th anniversary of BAM (1)
- 2,5-dihydroxyacetophenone (1)
- 280 nm (1)
- 2D chromatography (1)
- 6xHis (1)
- AAA (1)
- AAAA (1)
- ABC (1)
- ABID (1)
- AF4 (1)
- AIE (1)
- AIS (1)
- ATCUN (1)
- Aautomatisation (1)
- Absorption (1)
- Abwasser (1)
- Acoustic (1)
- Acoustic resonance (1)
- Acrylamide (1)
- Acute myocardial infarction (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Adsorbable organically bound fluorine (AOF) (1)
- Adulteration (1)
- Advanced Materials (1)
- Advanced material (1)
- Advanced materials (1)
- Advanced nanomaterials (1)
- Affinity (1)
- Affinity Chromatography (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Affinity extraction (1)
- AgInS (1)
- Aggregates (1)
- Aggregation-induced emission (1)
- Aging (1)
- Agriculture (1)
- Air filter samples (1)
- Air particulate matter (1)
- Air sampling (1)
- Airport (1)
- AlCl (1)
- Alanine scan (1)
- Algorithms (1)
- Altenuene (1)
- Alternaria mycotoxins (1)
- Aluminum (1)
- Aluminum oxide (1)
- Alzheimer’s disease (1)
- Amino acid analysis (1)
- Amoxicillin (1)
- Amplification (1)
- Amyloid-beta (1)
- Analysis (1)
- Analytical methods (1)
- Analytical sciences (1)
- Aneurysm (1)
- Angiography (1)
- Angiotensin II (1)
- Anhydrite (1)
- Aniline (1)
- Animal slurry (1)
- Anion recognition (1)
- Antagonists (1)
- Anthropocene (1)
- Antibody Purification (1)
- Antibody antigen complex (1)
- Antibody coating (1)
- Antibody identification (1)
- Antibody quality (1)
- Antibody-gated indicator delivery (1)
- Antifouling surface (1)
- Antigens (1)
- Antimicrobial resistance (1)
- App (1)
- Application (1)
- Aqueous quantum dot (1)
- Aqueous synthesis (1)
- Arabidopsis (1)
- Argon (1)
- Array (1)
- Arsenite (1)
- Artificial Neural Networks (1)
- Artificial intelligence (1)
- Artificial neural networks (1)
- Artificial weathering (1)
- Ash content (1)
- Aspergillus (1)
- Assay (1)
- Atherosclerotic plaques (1)
- Atmospheric aerosol (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Atomic and molecular physics, and optics (1)
- Atomic force microscopy (1)
- Atomic weight (1)
- Augenbohne (1)
- Autoantibodies (1)
- Automated Purification (1)
- Automated image analysis (1)
- Automation (1)
- Autophagy (1)
- Aviation (1)
- Aza-BODIPY (1)
- BAM (1)
- BCA test (1)
- BODIPY dyes (1)
- BODIPY probe (1)
- BODIPYs (1)
- BPA removal (1)
- Back-side integration (1)
- Bacterial lipopolysaccharides (1)
- Bacterial lysates (1)
- Ball milling (1)
- Bassanite (1)
- Bead injections (1)
- Benchmarking study (1)
- Benchtop NMR (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Benzin (1)
- Benzothiadiazole (1)
- Benzoxadiazole dyes (1)
- Beschichtung (1)
- Bet v 1 (1)
- Betula pendula (1)
- Binary gas mixture (1)
- Binder (1)
- Binding molecule (1)
- Binding strength (1)
- Bio-interaction (1)
- Bioanalysis (1)
- Biochip (1)
- Biodiesel (1)
- Biodiesel fuel (1)
- Biofilm (1)
- Bioimaging (1)
- Bioinformatics (1)
- Biokorrosion (1)
- Biology (1)
- Biomarker (1)
- Biomarkers (1)
- Biomimicry (1)
- Biosensoren (1)
- Biosensors (1)
- Bioseparation (1)
- Biosilicification (1)
- Biosynthesis (1)
- Biotechnology (1)
- Biotests (1)
- Birch pollen allergen (1)
- Bismuth (1)
- Boden (1)
- Boltzmann plot (1)
- Bombs (1)
- Border surveillance (1)
- Boron compound (1)
- Borosilicate Glass (1)
- Bovine serum albumin (BSA) (1)
- Bradford (1)
- Building material (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- Byproducts (1)
- C-C coupling (1)
- CCQM (1)
- CE/MC-ICP-MS (1)
- CEA (1)
- CO2 + n-alkanes (1)
- COVID-19 (1)
- CRM (1)
- CRP (1)
- CUINS2 nanocrystals (1)
- CaCl emission bands (1)
- Cadmium (1)
- Calcite (1)
- Calcium (1)
- Calcium carbonate (1)
- Calcium carbonates (1)
- Calibrated fluorescence measurements (1)
- Calibration-free analysis (1)
- Cancer awareness measure (1)
- Cancer cells (1)
- Cancer risk (1)
- Canine olfactometry (1)
- Carbamazepine (1)
- Cardiac troponin (1)
- Cardiolipins (1)
- Cardiovascular (1)
- Carrier (1)
- Carrier protein (1)
- Carriers (1)
- Cconventional method (1)
- Cell (1)
- Cell studies (1)
- Cellular substructure (1)
- Cellulose (1)
- Cement clinker remnants (1)
- Cerium oxide (1)
- Charged dyes (1)
- Chelate (1)
- Chemical Process Control (1)
- Chemical Safety (1)
- Chemical evolution (1)
- Chemical protein modification (1)
- Chemiluminescence (1)
- Chemodosimeter (1)
- Chemometrics (1)
- Chicken antibodies (1)
- Chirality (1)
- Chlorides (1)
- Chlorine (1)
- Chlorine determination (1)
- Chloroanilines (1)
- Ciaaw.org (1)
- Citation (1)
- Citizen Science (1)
- Citrullinated (1)
- Classical primary measurement method (CPM) (1)
- Classification (1)
- Cleaning (1)
- Cleavage (1)
- Climate (1)
- Clinical Biochemistry (1)
- Clone M2 (1)
- Clones (1)
- Cmos (1)
- Cobaloxime complex (1)
- Cocoa (1)
- Collaborative trial (1)
- Collagen (1)
- Collection (1)
- Colloidal semiconductor nanocrystals (1)
- Color (1)
- Column holder (1)
- Combinatorial chemistry (1)
- Combinatorial peptide library (1)
- Combustion (1)
- Combustion ion chromatography (1)
- Combustion ion chromatography (CIC) (1)
- Commercial metal-organic frameworks (1)
- Commercialization (1)
- Compartmentalization (1)
- Competitive Immunoassay (1)
- Competitive immunoassay (1)
- Complexation (1)
- Compound-independent calibration (1)
- Concentration step (1)
- Concrete (1)
- Confiscation (1)
- Conformation (1)
- Conjugate (1)
- Construction (1)
- Construction products (1)
- Consumer Products (1)
- Continuous Processes (1)
- Continuous Sensor (1)
- Continuous processes (1)
- Conventional isotope ratio (1)
- Converter material (1)
- Coordination polymer (1)
- Core-shell (1)
- Core–shell particles (1)
- Corona virus (1)
- Corophium volutator (1)
- Corundum (1)
- Cr(III) complex (1)
- Cross section (1)
- Cross-sectioning (1)
- Cryoadsorption (1)
- Cucurbituril (1)
- Customs (1)
- Cyanide in soil (1)
- Cyber-Physical Systems (1)
- Cyber-physical system (1)
- Cyclic voltammetry (1)
- Cyclometalated iridium (III) complexes (1)
- Cytoplasm (1)
- DFA (1)
- DFT (1)
- DHAP (1)
- DNA (1)
- DNA radiation damage (1)
- DNA strand breaks (1)
- DPA (1)
- Damage-associated molecular patterns (DAMPs) (1)
- Data (1)
- Data Fusion (1)
- Data infrastructures (1)
- Data processing (1)
- De novo peptide sequencing (1)
- Deep learning-based tools (1)
- Degradation of refrigerants (1)
- Delta isotope standard (1)
- Delta value (1)
- Dendrimer (1)
- Density data (1)
- Design of experiment (1)
- Detection (1)
- Deterioration (1)
- Development (1)
- Diagnostic Antibodies (1)
- Diastolic dysfunction (1)
- Diatomic molecule (1)
- Diclofenac (1)
- Diesel exhaust (1)
- Diffusion (1)
- Digestion (1)
- Digital Transformation (1)
- Digital Twins (1)
- Digital holographic cytometry (1)
- Digital immunoassay (1)
- Digital representations (1)
- Digital transformation (1)
- Digital twins (1)
- Digital workflows (1)
- Dip-stick assay (1)
- Disinfection (1)
- Dissociation constant (1)
- Dissolution (1)
- Dityrosine crosslinking (1)
- Docking (1)
- Down Stream Processing (1)
- Downstream processing (1)
- Drug Discovery (1)
- Drug search (1)
- Drug trafficking (1)
- Dual sensing (1)
- Dual-color labeling glycan (1)
- Duplex stainless steels (1)
- Dyad (1)
- Dye loading optimisation (1)
- Dye monomers (1)
- Dye release (1)
- Dyes (1)
- Dyes/pigments (1)
- Dynamic calibration gas mixtures (1)
- EC/MS (1)
- ECR (1)
- EDTAD (1)
- EP-3533 (1)
- ESMA (1)
- EU-WFD (1)
- EXAFS (1)
- Early Earth (1)
- Ecotoxicity (1)
- Editorial (1)
- Elastin (1)
- Elastin-specific contrast agent ESMA (1)
- Elastin-specific molecular agent (1)
- Electrochemical (1)
- Electrochemical titration (1)
- Electron transfer (1)
- Elektrochemie (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Emergency (1)
- Emission testing (1)
- Enantiomeric excess ee (1)
- Encapsulation (1)
- Encoding (1)
- Endokriner Disruptor (1)
- Enhancement strategy (1)
- Environment (1)
- Environmental Engineering (1)
- Environmental pollutants (1)
- Environmental simulations (1)
- Environmental speciation (1)
- Enzyme (1)
- Enzyme-Linked Immunosorbent Assay (1)
- Equation of state (1)
- Equations of state (1)
- Equilibrium constant (1)
- Error correction (1)
- Escherichia coli (1)
- Esterification (1)
- Estrogens (1)
- Ethylenediaminetetraacetic acid (1)
- Etofenprox (1)
- European Reference Material (1)
- Evanescent wave (1)
- Ex vivo (1)
- Excimers (1)
- Excitation (1)
- Exhaust (1)
- Experiment (1)
- Explosives detection (1)
- Exposure (1)
- Extractable organically bound fluorine (EOF) (1)
- Extraction (1)
- FFF-3D printer (1)
- FFF-3D printing (1)
- FLAG peptide (1)
- FPLC (1)
- FRET (1)
- False Positives (1)
- Feature selection (1)
- Fenton (1)
- Fenton’s reagent (1)
- Finow Canal (1)
- Flexible crystals (1)
- Flourescence (1)
- Flourescin (1)
- Flow injection immunoassay (1)
- Fluorescein (1)
- Fluorescence Polarization (1)
- Fluorescence label (1)
- Fluorescence life time (1)
- Fluorescence spectroscopy (1)
- Fluorescence standard (1)
- Fluorescent dyes (1)
- Fluorescent probes (1)
- Fluorescent sensors (1)
- Fluoreszenz (1)
- Fluorides (1)
- Fluorination (1)
- Fluoroacetic acid (1)
- Fluorophilic interactions (1)
- Folding chirality (1)
- Food fermentation (1)
- Food safety (1)
- Forsterite (1)
- Fourier transform spectroscopy (1)
- Fow injection analysis (1)
- Fragmentation pathway (1)
- Freisetzung (1)
- Fully aromatic frameworks (1)
- Functional group quantification (1)
- Functional monomers (1)
- Fungicide (1)
- Funtional Groups (1)
- Fusarium (1)
- Fusarium mycotoxin (1)
- GC/MS (1)
- GC/MS-MS (1)
- GF-MAS (1)
- GMAW (1)
- Gadolinium-based contrast agent (1)
- Gadovist (1)
- Galvanic anodes (1)
- Gamma-hydroxybutyric acid (1)
- Gas analysis (1)
- Gas sensing (1)
- Gasoline (1)
- Gated materials (1)
- Gd-DOTA (1)
- General Chemistry (1)
- Genotoxicity testing (1)
- Geological material (1)
- Germanium chlorides (1)
- Ggadolinium (1)
- Github (1)
- Glass Support (1)
- Gold (1)
- Gold nanocluster (1)
- Grafting (1)
- Graphene (1)
- Graphite furnace (1)
- Grass pollen (1)
- Green light excitation (1)
- Ground water (1)
- Groundwater (1)
- Group profile (1)
- Guanidinium receptors (1)
- Gypsum (1)
- Gypsum dehydration (1)
- HAXPES (1)
- HF free Digestion (1)
- HPLC-DAD/FLD (1)
- HPSEC (1)
- HR-CS-MAS (1)
- Hafnium (1)
- Hapten Immunoassay (1)
- Hay fever (1)
- Heart attack (1)
- Heat accumulation (1)
- Heat flow (1)
- Heat-transfer Measurements (1)
- Heavy chains (1)
- Hemihydrate (1)
- Hepatocellular carcinoma (1)
- HexaHis-Tag (1)
- High entropy alloy (1)
- High pH (1)
- High pressure experiments (1)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (1)
- High-Speed (1)
- High-Speed Separations (1)
- High-fired gypsum (1)
- High-fired gypsum mortar (1)
- High-fired medieval gypsum mortars (1)
- High-frequency arc discharge (1)
- High-pressure density (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- High-resolution continuum source molecular absorption spectrometry (1)
- High-throughput (1)
- His6 (1)
- His8 (1)
- Histidine (1)
- Hot-electrons (1)
- Human Plasma (1)
- Human leukocyte antigen (HLA) (1)
- Human papillomavirus (1)
- Human serum albumin (1)
- Humic matter (1)
- Hydrated silicate melts (1)
- Hydration (1)
- Hydrochloric acid (1)
- Hydrodynamic chromatography (HDC) (1)
- Hydrodynamic model (1)
- Hydrogen Storage (1)
- Hydrogen adsorption (1)
- Hydrogen adsorption storage (1)
- Hydrogen reduction (1)
- Hydrogen uptake reproducibility (1)
- Hydrogen-containing gas mixture (1)
- Hydrogen-enriched natural gas (1)
- Hydrogenasen (1)
- Hydrothermal fluid (1)
- Hydroxy warfarin (1)
- IC50 (1)
- ICP-MS/MS (1)
- ICP-TOFMS (1)
- ICP-ToF-MS (1)
- ID-MS (1)
- ILC (1)
- IMAC purification (1)
- IR spectroscopy; conductometry (1)
- ISO REMCO (1)
- Identity (1)
- IgE (1)
- IgG determination (1)
- IgY (1)
- Illicit drug (1)
- Image analysis (1)
- Image segmentation (1)
- Imaging Technique (1)
- Imidazole (1)
- Immunassay (1)
- Immunoassays (1)
- Immunoglobulin E (1)
- Immunohistochemistry (1)
- Immunology (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunoprecipitation (1)
- Impact (1)
- Imprinting (1)
- Impurites (1)
- In situ (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In situ measurement (1)
- In vivo (1)
- In-house calibration solution (1)
- In-situ analysis (1)
- In-situ process monitoring (1)
- In-vivo (1)
- Indicator displacement assay (1)
- Indoor air quality (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inductively coupled plasma mass spectroscopy (1)
- Inductively‑coupled mass spectrometry (1)
- Industrial gypsum (1)
- Inert gases (1)
- Infrared thermography (1)
- Inhibition (1)
- Inline Analytics (1)
- Inorganic chemical analysis (1)
- Inorganic impurities (1)
- Instrumental isotope fractionation (1)
- Inter layer time (1)
- Interferometric spectroscopy (1)
- Intermixing (1)
- Internal standard (1)
- International drug trade (1)
- Ion mobility spectrometry (1)
- Ionophore (1)
- Ionophore antibiotics (1)
- Iposomes (1)
- Iridium (1)
- Isotope Dilution (1)
- Isotope Labelling (1)
- Isotope amount ratio (1)
- Isotope delta value (1)
- Isotope dilution mass spectrometry (1)
- Isotope reference material (1)
- Isotope-labeled (1)
- Isotopic analysis (1)
- Isotopic fractionation (1)
- Isotopologue Distribution (1)
- Iterative real-time optimization (1)
- Jahrestag (1)
- Job plot (1)
- Kjeldahl (1)
- Knowledge graphs (1)
- Kompost (1)
- LA/ICP-MS Imaging (1)
- LC-MS (1)
- LC-UV absorbance (1)
- LC/HRMS (1)
- LC/MS-MS (1)
- LFIA (1)
- LSVEC (1)
- Lab on a chip (1)
- Lab-on-a-Chip (1)
- Laboratory 4.0 (1)
- Lacunary Keggin ion (1)
- Ladder sequencing (1)
- Lasalocid (1)
- Laser Ablation (1)
- Laser ablation-inductively coupled plasma-mass spectrometry (1)
- Laser ablation-inductively coupled plasma-mass spectroscopy (1)
- Laser induced breakdown Spectrocopy (LIBS) (1)
- Laser induced breakdown spectroscopy (1)
- Laser induced plasma (1)
- Laser induced plasma deposition (1)
- Laser powder bed fusion (1)
- Laser-induced breakdown spectroscopy (1)
- Laser-induced dielectric breakdown (LIDB) (1)
- Laser-induced fluorescence (1)
- Layer-by-Layer (1)
- Layers (1)
- Leaching (1)
- Lead (1)
- Legacy pollution (1)
- LiYF4 (1)
- Library (1)
- Life science (1)
- Lifetime encoding (1)
- Lifetime-encoded beads (1)
- Light chain (1)
- Light chains (1)
- Light harvesting (1)
- Lipidomics (1)
- Lipids (1)
- Liquid chromatography (1)
- Liver X receptor (1)
- Lluminescence (1)
- Longst luminescence lifetime (1)
- Low-cost (1)
- Low-energy electrons (1)
- Luminescent lifetime (1)
- Luminol (1)
- Lymnaea stagnalis (1)
- Lysergic acid hydrazide (1)
- Lysosome (1)
- MALDI-TOF-MS (1)
- MC-TIMS (1)
- MCR (1)
- MIC (1)
- MICAP-MS (1)
- MLCT (1)
- MOF´s (1)
- MOSH/MOAH (1)
- MR Angiography (1)
- MR imaging (1)
- MST (1)
- MW-AES (1)
- MYCN (1)
- Machine learning (1)
- Macrophages (1)
- Magnesium (1)
- Magnesium carbonates (1)
- Magnetic (1)
- Magnetic nanocatalyst (1)
- Mass-Spectrometry (1)
- Massenspektrometrie (1)
- Material sciences (1)
- Materials informatics (1)
- Mechanical properties (1)
- Medical diagnostics (1)
- Medicinal application (1)
- Medicine (1)
- Medium entropy alloy (1)
- MefHySto (1)
- Mercury speciation (1)
- Meso Portland cement (1)
- Mesofluidics (1)
- Mesoporous particles (1)
- Metabolic Flux (1)
- Metabolization (1)
- Metal cluster (1)
- Metal toxicity (1)
- Metal uptake (1)
- Metalloprotein (1)
- Metals (1)
- Metal−organic frameworks (1)
- Methanol oxidation (1)
- Methylanilines (1)
- Methylmercury (1)
- Metrology in chemistry (1)
- Microarray (1)
- Microbe interactions (1)
- Microbially Induced Corrosion (1)
- Microfluidic (1)
- Microfluidic mixing (1)
- Microfluidic system (1)
- Microfluids (1)
- Micrometeorites (1)
- Microorganism (1)
- Microplastic-induced effects (1)
- Microplatic (1)
- Microscope slides (1)
- Microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) (1)
- Microwave-assisted synthesis (1)
- Mikrofluidik (1)
- Miller and Urey (1)
- Mineral identification (1)
- Mineral oil hydrocarobons (1)
- Mineral paragenesis (1)
- Miniaturization (1)
- Missing fragmentation sites (1)
- Mixed surface (1)
- Mixture toxicity (1)
- Mobile analytics (1)
- Mobile phase (1)
- Model (1)
- Model Predictive Control (1)
- Modeling (1)
- Modified mycotoxins (1)
- Modifier adaptation (1)
- Molecular Biology (1)
- Molecular MRI (1)
- Molecular Organic Frameworks (1)
- Molecular imprinted polymers (1)
- Molecular marker (1)
- Molecular spectra (1)
- Molecular-MRI (1)
- Molecule (1)
- Monensin (1)
- Monoclonal Antibody (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Monomer (1)
- Monte Carlo algorithm (1)
- Mounting media (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multi-element analysis (1)
- Multi-prinicpal element alloys (MPEAs) (1)
- Multiple sclerosis (1)
- Multiple-injection sample-standard bracketing (1)
- Multiplex (1)
- Multiplexed assay (1)
- Multivariat (1)
- Multivariate (1)
- Multivariate data analysis (1)
- Multivariate methods (1)
- Murchison meteorite (1)
- NIR Spectroscopy (1)
- NIR dyes (1)
- NIR-I (1)
- NIR-II fluorescence (1)
- NIST (1)
- NIST-mAb 8671 (1)
- NMR Spectroscopy (1)
- NSE (1)
- Nanaoparticle (1)
- Nanaoparticles (1)
- Nano-carrier (1)
- Nanocarrier (1)
- Nanolenses (1)
- Nanomaterial design (1)
- Nanoparticle characterization (1)
- Nanoparticle dimers (1)
- Nanopartikel (1)
- Nanopowder (1)
- Nanosafety (Safe-by-design) (1)
- Nanoscience (1)
- Nanosciences (1)
- Nanostructures (1)
- Naphthalene (Nap) (1)
- Narcotics (1)
- Neoallergen (1)
- Neoepitopes (1)
- Neural networks (1)
- Neutral dyes (1)
- Nickel chelate (1)
- Nile Red (1)
- Nitrogen dioxide (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Nitrogen monoxide (1)
- Nitrogen plasma (1)
- Non-targeted analysis (1)
- Nonspecific binding (NSB) (1)
- Nuclear Magnetic Resonance Spectroscopy (1)
- Nuclear receptor (1)
- Nucleocapsid (1)
- OBOC library (1)
- Ochratoxin A (1)
- Oil spills (1)
- Oligomerization (1)
- Oligonucleotides (1)
- On-chip screening (1)
- On-line CE/MC-ICP-MS (1)
- On-site detection (1)
- One-bead-one-compound library (1)
- Online NMR Spectroscopy (1)
- Online NMR spectroscopy (1)
- Online biosensor (1)
- Online detection (1)
- Ontologies (1)
- Open science (1)
- Optical assay (1)
- Optical imaging (1)
- Optically active surfaces (1)
- Orbitrap (1)
- Organic Synthesis (1)
- Organic calibration solution (1)
- Organic contaminants (1)
- Organic-inorganic hybrid composites (1)
- Organic–inorganic nanostructures (1)
- Oriented immobilization (1)
- Osmotic minipumps (1)
- Oxidative metabolism (1)
- Oxygen evolution reaction (1)
- Oxygen isotope ratios (1)
- Oxygen sensitive (1)
- PAHs (1)
- PCA (1)
- PDT (1)
- PIC technology (1)
- PLSR (1)
- PSA (1)
- Packing density (1)
- Pants (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Particle architecture (1)
- Particle synthesis (1)
- Pattern recognition receptor (1)
- Pd(II) (1)
- Peer review (1)
- Peptide aptamers (1)
- Peptide binder (1)
- Peptide folding (1)
- Peptide mass fingerprinting (1)
- Peptide probe (1)
- Peptides (1)
- Peptides and Proteins (1)
- Per- and polyfluorinated alkyl substances (PFASs) (1)
- Per- and polyfluoroalkyl substances (PFAS) (1)
- Perfluorooctanoic Acid (PFOA) (1)
- Permethrin (1)
- Peroxidase (1)
- Perturbed-Chain Statistical Association Fluid Theory (1)
- Pesticide (1)
- Petroleum (1)
- Pflanzenvirus (1)
- Pflanzenwachstum (1)
- Pharmaceutical (1)
- Pharmaceutical Science (1)
- Phase Imaging (1)
- Phenanthrene (1)
- Phenothrin (1)
- Phenylketonuria (1)
- Phl p 5 (1)
- Phleum pratense (1)
- Phosphinine (1)
- Phospholipids (1)
- Phosphor (1)
- Phosphorescence (1)
- Phosphorus elimination (1)
- Phosphorus recovery (1)
- Photocatalysis (1)
- Photocatalytic reduction (1)
- Photochemistry (1)
- Photoinduced Electron Transfer (1)
- Photoinduced electron transfer (1)
- Photonic biosensor (1)
- Photosensitization (1)
- Photostability (1)
- Physical and theoretical chemistry (1)
- Physical twin (1)
- Physico-chemical characterisation of minerals (1)
- Phytoliths (1)
- Planck function (1)
- Plant virus (1)
- Plant-model mismatch (1)
- Plasma chemistry (1)
- Plasmonic heating (1)
- Plastic deformation (1)
- Point of inflection (1)
- Polarised light microscopy (1)
- Polarity (1)
- Polishing (1)
- Pollen (1)
- Pollen extract (1)
- Pollutant (1)
- Polyclonal Antibodies (1)
- Polycyclic aromatic hydrocarbons (1)
- Polyelektrolyt (1)
- Polyglycerol (1)
- Polymer particles (1)
- Polymer-based products (1)
- Polymere (1)
- Polymerization (1)
- Polymers (1)
- Polyoxometalates (1)
- Polystyrene microparticles (1)
- Pore fluids (1)
- Porous rock (1)
- Porphyrin (1)
- Portable (1)
- Portland clinker (1)
- Potash (1)
- Powder X-ray diffraction (1)
- Power density (1)
- Pphotophysics (1)
- Prebiotic chemistry (1)
- Precision agriculture (1)
- Precision farming (1)
- Preprocessing (1)
- Primary difference measurement method (PDM) (1)
- Primary transfer standards (PTSs) (1)
- Primordial soup (1)
- Principal component analysis (PCA) (1)
- Priority effect (1)
- Process Analytical Tecnology (1)
- Process Control (1)
- Process analytical technology (1)
- Process industry (1)
- Process intelligence (1)
- Process monitoring (1)
- Programmed cell death (1)
- Proinflammatory cytokines (1)
- Protein G (1)
- Protein Purification (1)
- Protein content (1)
- Protein degradation (1)
- Protein folding (1)
- Protein hydrolysis (1)
- Protein oligomerization (1)
- Protein oligomers (1)
- Protein quantification (1)
- Protein test (1)
- Protein-modification (1)
- Proteinoid (1)
- Provenance (1)
- Provenancing (1)
- Proximal soil sensing (1)
- Proximity-enhanced reaction (1)
- Pseudomonas aeruginosa (1)
- Pt(111) (1)
- Pt(II) (1)
- PtNP (1)
- Public Health, Environmental and Occupational Health (1)
- Purification (1)
- Purity (1)
- Quality assurancemechanism (1)
- Quantitative Analysis (1)
- Quantitative determination (1)
- Quantitative protein analysis (1)
- Quantum chemistry (1)
- Quartz (1)
- R package (1)
- RBD (1)
- REMPI (1)
- Racemate (1)
- Rainwater (1)
- Raman band width (1)
- Raman microscopy (1)
- Raman-spectroscopy (1)
- Rapid test (1)
- Rapid tests (1)
- Rat/human liver microsomes (1)
- Ratiometric (1)
- Reactor control (1)
- Real-time imaging (1)
- Real-time quality control (1)
- Recombinant Antibody (1)
- Recombinant antibody (1)
- Recombinant protein (1)
- Redox (1)
- Redox switch (1)
- Reference (1)
- Reference Material (1)
- Reference Materials (1)
- Reference data (1)
- References (1)
- Reliability (1)
- Remediation (1)
- Renal disease (1)
- Renewable copolymers (1)
- Replication (1)
- Replication crisis (1)
- Reporter (1)
- Reproducibility crisis (1)
- Resistance (1)
- Resonance wavelength shift (1)
- Reverse microemulsion (1)
- Reversible covalent hydrazine chemistry (RCHC) (1)
- Rheumatoid arthritis (1)
- Rhizopus (1)
- Rhizopus and Aspergillus oryzae (1)
- Rhodamine (1)
- Ring resonator (1)
- River water sulfate (1)
- Robustness (1)
- Rosamine (1)
- Roughness (1)
- Ruthenium(II) complexes (1)
- SA conjugates (1)
- SAXS (1)
- SBA-15 (1)
- SBA-16 (1)
- SEC (1)
- SEM (1)
- SERDS (1)
- SERS (1)
- SI Traceability (1)
- SIDA-LC-MS/MS (1)
- SKPFM (1)
- SOM-SM (1)
- SVOC (1)
- Safe by design (1)
- Salicylic acid (1)
- Salinomycin (1)
- Salts (1)
- Sample preparation (1)
- Scale anchor (1)
- Scale conversion (1)
- Scattering (1)
- Schlangenbohne (1)
- Schlieren Imaging (1)
- Schnelltest (1)
- Scientific publication (1)
- Seawater (1)
- Security (1)
- Sediment (1)
- Segregation (1)
- Selenium (1)
- Self-absorption (1)
- Self-assembled monolayers (SAM) (1)
- Semiconductor (1)
- Semiconductor nanocrystals (1)
- Semiconductor quantum dot (1)
- Sensor Materials (1)
- Sensory particles (1)
- Sequence dependence (1)
- Sequencing (1)
- Sequencing algorithm (1)
- Serum (1)
- Shadowgraphy (1)
- Silanization (1)
- Silica and polystyrene nanoparticles (1)
- Silica coating (1)
- Silica diagenesis (1)
- Silicon (1)
- Silicon chlorides (1)
- Silicon isotopes (1)
- Simulation (1)
- Single Cell (1)
- Single enhancement (1)
- Single particle ICP-MS (1)
- Single-cell analysis (1)
- Single-sinker densimeter (1)
- Singlet oxygen (1)
- Sintered Material (1)
- Small-angle scattering (1)
- Smart sensors (1)
- Smart test laboratories (1)
- Smarter Sensor (1)
- Smartphone readout (1)
- Soil contact (1)
- Soil heterogeneity (1)
- Sol-gel process (1)
- Solar cells (1)
- Solar concentrator (1)
- Solar energy (1)
- Solid (1)
- Solid state (1)
- Solid state emission (1)
- Solid-phase extraction (SPE) (1)
- Sorghum (1)
- Spark plasma sintering (1)
- Spatial heterodyne spectrometer (1)
- Special issue (1)
- Specific probe (1)
- Spectoscopic imaging (1)
- Spectrometer (1)
- Spectrometry (1)
- Spectroscopic imaging (1)
- Spectroscopy / Instrumentation (1)
- Spectroscopy / Theory (1)
- Speed of sound (1)
- Spike protein (1)
- Sr isotope analysis (1)
- SsNMR (1)
- Stability (1)
- Stable isotopes (1)
- Standard atomic weight (1)
- Statistics (1)
- Steel (1)
- Stepwise growth (1)
- Stranski–Krastanow growth (1)
- Strontium isotope (1)
- Structural Biology (1)
- Structure-property relationship (1)
- Sub-4nm particles (1)
- Substance release (1)
- Sulfide sensing (1)
- Sulfur (1)
- Sulfur isotopes (1)
- Sulphur isotope (1)
- Sum Parameter (1)
- Sum Parameter Method (1)
- Sum parameter method (1)
- Supported catalyst (1)
- Supramolecular Chemistry (1)
- Surface Chemistry (1)
- Surface coating (1)
- Surface derivatization (1)
- Surface ligand (1)
- Surface plasmon resonance (1)
- Surface waters (1)
- Surface-enhanced Raman scattering (1)
- Surface-plasmon resonance (1)
- Surrogate citations (1)
- Sustainable Production (1)
- Suzuki coupling (1)
- Suzuki-Miyaura coupling (1)
- Swell-capture (1)
- Synchrotron FTIR (1)
- TEM (1)
- TFA (1)
- TLR4 activation (1)
- Tantalum oxyfluorides (1)
- Target (1)
- Tau (1)
- Temperature (1)
- Temperature Control (1)
- Terephthalic acid (1)
- Terrorism (1)
- Test midpoint (1)
- Test strip (1)
- Tetracyclin (1)
- Tetramethylammonium hydroxide (1)
- Theranostic (1)
- Therapeutic Antibodies (1)
- Thermal Process Engineering (1)
- Thermocouple (1)
- Thermodynamic analysis (1)
- Thermography (1)
- Thick shells (1)
- Thickness (1)
- Thin films (1)
- Tholins (1)
- Tissue (1)
- Titanium dioxide (1)
- ToF-SIMS (1)
- Toll-like receptor 4 (1)
- Tomography (1)
- Topical collection: Analytical Methods and Applications in the Materials and Life Sciences (1)
- Total cyanide (1)
- Total element determination (1)
- Toxicity testing (1)
- Toys (1)
- Trace Analysis (1)
- Transferrin (1)
- Transformation (1)
- Transient signal (1)
- Transpassive dissolution (1)
- Truffle (1)
- Truffle Aroma (1)
- Trust (1)
- Tryptic digest (1)
- Tryptophan (1)
- Tuber melanosporum (1)
- Tutzing Symposion (1)
- Type-I pyrethroids (1)
- UV Vis (1)
- UV radiation (1)
- UV–Vis spectroscopy (1)
- Ultrasensitive (1)
- Umweltschadstoffe (1)
- Upconverion (1)
- Upconverstion (1)
- Upscaling (1)
- VO (1)
- VVOC (1)
- Validate method (1)
- Validation trial (1)
- Vanadium (1)
- Vanadium oxide catalysts (1)
- Vegetable edible oil (1)
- Veterinary drugs (1)
- Vigna unguiculata (1)
- Virial coefficients (1)
- Visualization (1)
- Vocabulary providers (1)
- Volatile organic compounds (1)
- Volatile organic compounds; (1)
- Volumetric uptake (1)
- Vor-Ort-Analytik (1)
- WD-XRF (1)
- WWTP (1)
- Warfarin (1)
- Wasser (1)
- Wastewater (1)
- Water (1)
- Water contact (1)
- Whole water samples (1)
- Wipe test (1)
- Wood chips (1)
- Work function (1)
- Workflow (1)
- X-Ray analysis (1)
- X-Ray fluorescence (1)
- X-ray (1)
- X-ray diffraction (1)
- X-ray spectroscopy (1)
- XANES (1)
- YES assay (1)
- Yerba mate tea (1)
- Ytterbium (1)
- Zearalenone (1)
- Zearalenone sulfate (1)
- Zellulose (1)
- Zenodo (1)
- Zeolithe (1)
- Zinc (1)
- Zinc oxide (1)
- a-zearalenol (1)
- calibration (1)
- compost (1)
- dye (1)
- lank characterization (1)
- magnetic nanocatalysts (1)
- pH probe (1)
- photoluminescence (1)
- research landscape (1)
- self-replication (1)
- spICP-MS (1)
- species-specific isotope information (1)
- tandard addition (1)
- temperature (1)
- thermophysical properties (1)
- transmission mode (1)
- β-Lactam (1)
- γ-H2AX assay (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (351) (entfernen)
Paper des Monats
- ja (12)
We report an analytical methodology for the quantification of sulfur in biological molecules via a speciesunspecific postcolumn isotope dilution (online ID) approach using capillary electrophoresis (CE) coupled online with inductively coupled plasma−mass spectrometry (online ID CE/ICP−MS).
The method was optimized using a mixture of standard compounds including sulfate, methionine, cysteine, cystine, and albumin, yielding compound recoveries between 98 and 105%. The quantity of sulfur is further converted to the quantity of the compounds owing to the prior knowledge of the sulfur content in the molecules. The limit of detection and limit of quantification of sulfur in the compounds were 1.3−2.6 and 4.1−8.4 mg L−1, respectively, with a correlation coefficient of 0.99 within the concentration range of sulfur of 5−100 mg L−1. The capability of the method was extended to quantify albumin in its native matrix (i.e., in serum) using experimentally prepared serum spiked with a pure albumin standard for validation. The relative expanded uncertainty of the method for the quantification of albumin was 6.7% (k = 2). Finally, we tested the applicability of the method on real samples by the analysis of albumin in bovine and human sera. For automated data assessment, a software application (IsoCor) which was developed by us in a previous work was developed further for handling of online ID data. The method has several improvements compared to previously published setups: (i) reduced adsorption of proteins onto the capillary wall owing to a special capillary-coating procedure, (ii) baseline separation of the compounds in less than 30 min via CE, (iii) quantification of several sulfur species within one run by means of the online setup, (iv) SI traceability of the quantification results through online ID, and (v) facilitated data processing of the transient signals using the IsoCor application. Our method can be used as an accurate approach for quantification of proteins and other biological molecules via sulfur analysis in complex matrices for various fields, such as environmental, biological, and pharmaceutical studies as well as clinical diagnosis.
Sulfur is an essential element in living organisms, where it plays important roles in various biological processes, such as protein synthesis, enzyme activity, and antioxidant defense. However, the biological effects of different sulfur species can vary widely, and imbalances in sulfur speciation have been observed in a range of diseases, including cancer, Alzheimer’s disease, and diabetes.1−3 The accurate quantification of sulfur and its species in biological samples requires sensitive and selective analytical techniques. In recent years, separation techniques coupled online with inductively coupled plasma−mass spectrometry (ICP−MS) have emerged as powerful online analytical tools complementary to molecular spectrometric methods for speciation analysis of biological compounds.
External calibration4−9 and isotope dilution (ID)10−15 are common calibration approaches applied for online quantification of sulfur species in complex samples. The ID analysis is advantageous over.
This work reports new experimental data on densities and viscosities of (CO2 + n-pentane) and (CO2 + n-hexane) mixtures at high pressures and temperatures. The densities were measured by a vibrating-tube densimeter with an expanded uncertainty (k = 2) smaller than 1.8 kg/m3 at six isotherms (from 273.15 K to 373.15 K), twelve pressures starting at 5 MPa up to 100 MPa, and at six CO2 molar compositions (from 0 to 0.6). The viscosities were measured by a vibrating-wire viscometer with the corresponding relative expanded uncertainty (k = 2) smaller than 0.016 at five isotherms (from 273.15 K to 373.15 K), twelve pressures (from 5 MPa up to 100 MPa), and at two CO2 molar compositions (0.1 and 0.3). The densities were fitted by the semiempirical Tammann-Tait equation for density data and the Vogel-Fulcher-Tammann (VFT) equation for viscosity data, respectively. The Groupe Européen de Recherches Gazières (GERG-2008) equation of state was also applied for modelling the densities. Over-all robustness and reliability of the Perturbed-Chain Statistical Association Fluid Theory (PC-SAFT) and its critical point-based modification (CP-PC-SAFT) were examined. Accuracies of the Modified Yarranton-Satyro (MYS) coupled with CP-PC-SAFT and the NIST Reference Fluid Thermodynamic and Transport Properties Database (REFPROP 10) in predicting the viscosities were evaluated.
Bifunctional fluorescent molecular oxoanion probes based on the benzoxadiazole (BD) chromophore are described which integrate a thiourea binding motif and a polymerizable 2-aminoethyl methacrylate unit in the 4,7-positions of the BD core. Concerted charge transfer in this electron donor-acceptor-donor architecture endows the dyes with strongly Stokes shifted (up to >250 nm) absorption and fluorescence. Binding of electron-rich carboxylate guests at the thiourea receptor leads to further analyte-induced red-shifts of the emission, shifting the fluorescence maximum of the complexes to ≥700 nm. Association constants for acetate are ranging from 1–5×105 M−1 in acetonitrile. Integration of one of the fluorescent probes through its polymerizable moiety into molecularly imprinted polymers (MIPs) grafted from the surface of submicron silica cores yielded fluorescent MIP-coated particle probes for the selective detection of antibiotics containing aliphatic carboxylate groups such as enoxacin (ENOX) at micromolar concentrations in highly polar solvents like acetonitrile.
The deposition of titanium oxides during titanium laser ablation in air has been experimentally and numerically investigated. A titanium sample was irradiated by nanosecond pulses from an Yb-fber laser with a beam scanned across the sample surface for its texturing. As a result, the hierarchical structure was observed consisting of a microrelief formed by the laser ablation and a nanoporous coating formed by the reverse deposition from the laser induced plasma plume. The chemical and phase composition of the nanoporous coating, as well as the morphology and structure of the surface, were studied using scanning electron microscopy, atomic force microscopy, and X-ray microanalysis. It was found that the deposit consists mostly of porous TiO2 with 26% porosity and inclusions of TiO, Ti2O3, and Ti2O3N. Optical emission spectroscopy was used to control the plasma composition and estimate the effective temperature of plasma plume. The chemical-hydrodynamic model of laser induced plasma was developed to get a deeper insight into the deposition process. The model predicts that condensed titanium oxides, formed in peripheral plasma
zones, gradually accumulate on the surface during the plasma plume evolution. A satisfactory agreement between the experimental and calculated chemical composition of the plasma plume as well as between the experimental and calculated composition and thickness of the deposited film was demonstrated. This allows a cautious conclusion that the formation of condensed oxides in the plasma and their consequent deposition onto the ablation surface are among the key mechanisms of formation of porous surface films.
Storage is still limiting the implementation of hydrogen as an energy carrier to integrate the intermittent operation of renewable energy sources. Among different solutions to the currently used compressed or liquified hydrogen systems, physical adsorption at cryogenic temperature in porous materials is an attractive alternative due to its fast and reversible operation and the resulting reduction in storage pressure. The feasibility of cryoadsorption for hydrogen storage depends mainly on the performance of the used materials for the specific application, where metal-organic frameworks or MOFs are remarkable candidates. In this work, gravimetric and volumetric hydrogen uptakes at 77 K and up to 100 bar of commercially available MOFs were measured since these materials are made from relatively cheap and accessible building blocks. These materials also show relatively high porous properties and are currently near to large-scale production. The measuring device was calibrated at different room temperatures to calculate an average correction factor and standard deviation so that the correction deviation is included in the measurement error for better comparability with different measurements. The influence of measurement conditions was also studied, concluding that the available adsorbing area of material and the occupied volume of the sample are the most critical factors for a reproducible measurement, apart from the samples’ preparation before measurement. Finally, the actual volumetric storage density of the used powders was calculated by directly measuring their volume in the analysis cell, comparing that value with the maximum volumetric uptake considering the measured density of crystals. From this selection of commercial MOFs, the materials HKUST-1, PCN-250(Fe), MOF-177, and MOF-5 show true potential to fulfill a volumetric requirement of 40 g·L−1 on a material basis for hydrogen storage systems without further packing of the powders.
Establishing ZIF‐8 as a reference material for hydrogen cryoadsorption: An interlaboratory study
(2024)
AbstractHydrogen storage by cryoadsorption on porous materials has the advantages of low material cost, safety, fast kinetics, and high cyclic stability. The further development of this technology requires reliable data on the H2 uptake of the adsorbents, however, even for activated carbons the values between different laboratories show sometimes large discrepancies. So far no reference material for hydrogen cryoadsorption is available. The metal‐organic framework ZIF‐8 is an ideal material possessing high thermal, chemical, and mechanical stability that reduces degradation during handling and activation. Here, we distributed ZIF‐8 pellets synthesized by extrusion to 9 laboratories equipped with 15 different experimental setups including gravimetric and volumetric analyzers. The gravimetric H2 uptake of the pellets was measured at 77 K and up to 100 bar showing a high reproducibility between the different laboratories, with a small relative standard deviation of 3–4 % between pressures of 10–100 bar. The effect of operating variables like the amount of sample or analysis temperature was evaluated, remarking the calibration of devices and other correction procedures as the most significant deviation sources. Overall, the reproducible hydrogen cryoadsorption measurements indicate the robustness of the ZIF‐8 pellets, which we want to propose as a reference material.
Physical adsorption at cryogenic temperature (cryoadsorption) is a reversible mechanism that can reduce the pressure of conventional compressed gas storage systems. Metal–organic framework (MOF) materials are remarkable candidates due to the combination of high specific surface area and density which, in some cases, provide a high volumetric storage capacity. However, such extensive use of MOFs for this application requires the selection of affordable structures, easy to produce and made from feasible metallic and organic components. Herein, we introduce a MOF database detailing the crystallographic and porous properties of 3600 existing MOFs made from industrially relevant metals and their organic composition. The comparison of the available minimum costs of linkers allowed the creation of a database to select affordable structures with high potential for volumetric hydrogen storage by cryoadsorption, considering their composition based on individual or mixed building blocks. A user interface, available online, facilitates the selection of MOFs based on the properties or names of structures and linkers.
Solid wastewater-based fertilizers were screened for per- and polyfluoroalkyl substances (PFAS) by the extractable organic fluorine (EOF) sum parameter method. The EOF values for ten sewage sludges from Germany and Switzerland range from 154 to 7209 mg kg−1. For thermal treated sewage sludge and struvite the EOF were lower with values up to 121 mg kg−1. Moreover, the application of PFAS targeted
and suspect screening analysis of selected sewage sludge samples showed that only a small part of the EOF sum parameter values can be explained by the usually screened legacy PFAS. The hitherto unknown part of EOF sum parameter contains also fluorinated pesticides, pharmaceutical and aromatic compounds. Because these partly fluorinated compounds can degrade to (ultra-)short PFAS in wastewater treatment plants they should be considered as significant sources of organic fluorine in the environment. The combined results of sum parameter analysis and suspect screening reveal the need to update current regulations, such as the German fertilizer ordinance, to focus not solely on a few selected PFAS such as perfluorooctane sulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) but
consider an additional sum parameter approach as a more holistic alternative. Moreover, diffusion gradient in thin-films (DGT) passive samplers were utilized as an alternative simplified extraction method for PFAS in solid wastewater-based fertilizers and subsequently quantified via combustion ion chromatography. However, the DGT method was less sensitive and only comparable to the EOF values
of the fertilizers in samples with >150 mg kg−1, because of different diffusion properties for various PFAS, but also kinetic exchange limitations.
The theory of a new calibration approach for obtaining absolute isotope ratios of multi-isotopic elements without the use of any standard has been developed. The calibration approach basically uses the difference in the instrumental isotope fractionation of two different types of mass spectrometers, leading to two different fractionation lines in a three-isotope diagram. When measuring the same sample with both mass spectrometers, the different fractionation lines have one point in common: this is the ‘true’ logarithmized isotope ratio pair of the sample. Thus, the intersection of both fractionation lines provides us with the absolute isotope ratios of the sample. This theory has been tested in practice by measuring Cd and of Pb isotope ratios in the certified reference materials BAM-I012 and NIST SRM981 by thermal ionization mass spectrometry and by inductively coupled plasma mass spectrometry while varying the ionization conditions for both mass spectrometers. With this experiment, the theory could be verified, and absolute isotope ratios were obtained, which were metrologically compatible with the certified isotope ratios. The so-obtained absolute isotope ratios are biased by − 0.5% in average, which should be improved with further developments of the method. This calibration approach is universal, as it can be applied to all elements with three or more isotopes and it is not limited to the type of mass spectrometers applied; it can be applied as well to secondary ion mass spectrometry or others. Additionally, this approach provides information on the fractionation process itself via the triple-isotope fractionation exponent θ.
Isotope ratio applications are on the increase and a major part of which are delta measurements, because they are easier to perform than the determination of absolute isotope ratios while offering lower measurement uncertainties. Delta measurements use artefact-based scales and therefore scale conversions are required due to the lack of the scale defining standards. Such scale conversions often form the basis for comparing data being generated in numerous projects andtherefore need to be as accurate as possible. In practice, users are tempted to apply linear approximations, which are not sufficiently exact, because delta values are defined by nonlinear relationships. The bias of such approximations often is beyond typical measurement uncertainties and its extent can hardly be predicted. Therefore, exact calculations are advised. Here, the exact equations and the bias of the approximations are presented, and calculations are illustrated by real-world examples. Measurement uncertainty is indispensable in this context and therefore, its calculation is described as well for determining delta values but also for scale conversions. Approaches for obtaining a single delta measurement and for repeated measurements are presented. For the latter case, a new approach for calculating the measurement uncertainty is presented, which considers covariances between the isotope ratios.
The continuous improvement of analytical procedures using multi-collector technologies in ICP-mass spectrometry has led to an increased demand for isotope standards with improved homogeneity and reduced measurement uncertainty. For magnesium, this has led to a variety of available standards with different quality levels ranging from artefact standards to isotope reference materials certified for absolute isotope ratios. This required an intercalibration of all standards and reference materials, which we present in this interlaboratory comparison study. The materials Cambridge1, DSM3, ERMAE143, ERM-AE144, ERM-AE145, IRMM-009 and NIST SRM 980 were cross-calibrated with expanded measurement uncertainties (95% confidence level) of less than 0.030‰ for the δ25/24Mg values and less than 0.037‰ for the δ26/24Mg values. Thus, comparability of all magnesium isotope delta (δ) measurements based on these standards and reference materials is established. Further, ERM-AE143 anchors all magnesium δ-scales to absolute isotope ratios and therefore establishes SI traceability, here traceability to the SI base unit mole. This applies especially to the DSM3 scale, which is proposed to be maintained. With ERM-AE144 and ERM-AE145, which are product and educt of a sublimation-condensation process, for the first time a set of isotope reference materials is available with a published value for the apparent triple isotope fractionation exponent θapp, the fractionation relationship ln α(25/24Mg)/ln α(26/24Mg).
The growth of ultrathin layers of VOx (<12 monolayers) on Pt(111) and the activity of these layers in catalytic methanol oxidation at 10−4 mbar have been studied with low-energy electron difraction, Auger electron spectroscopy, rate measurements, and with photoemission electron microscopy. Reactive deposition of V in O2 at 670 K obeys a Stranski–Krastanov growth mode with a (√3 × √3)R30° structure representing the limiting case for epitaxial growth of 3D-VOx. The activity of VOx/Pt(111) in catalytic methanol oxidation is very low and no redistribution dynamics is observed lifting the initial spatial homogeneity of the VOx layer. Under reaction conditions, part of the surface vanadium difuses into the Pt subsurface region.
Exposure to O2 causes part of the V to difuse back to the surface, but only up to one monolayer of VOx can be stabilized in this way at 10−4 mbar.
Within this work, the combination of a microdroplet generator and an ICP-ToF-MS for nanoparticle analysis is presented. For the size determination of platinum nanoparticles an on-line isotope dilution analysis approach was developed. The 194Pt/195Pt isotopic ratio was used for the characterization of the particles, while the 182W/183W isotopic ratio was monitored simultaneously for mass bias correction. The on-line ID-MDG-sp-ICP-ToF-MS approach was deployed for the size determination of three platinum nanoparticle samples (50 nm, 63 nm, 70 nm); for validation, complementary size characterization techniques (sp-ICP-ToF-MS and TEM) were used. The robustness of this technique was evidenced, by using sodium chloride concentrations up to 100 mg L−1 as a matrix component. Our new on-line ID MDG-sp-ICP-ToF-MS approach is a promising tool for the fast and reliable determination of nanoparticles' size in severe matrix concentrations, e.g., environmental samples.
AbstractSince the 1950s, Warfarin has been used globally as both a prescription drug and a rodenticide. Research has shown that warfarin and other rodenticides are present in the environment and food chain. However, emerging contaminants are subject to degradation by biotic and abiotic processes and advanced oxidation processes. In some cases, detecting the parent compound may not be possible due to the formation of structurally changed species. This approach aims to identify hydroxylated transformation products of warfarin in a laboratory setting, even after the parent compound has undergone degradation. Therefore, the Fenton reaction is utilized to insert hydroxylation into the parent compound, warfarin, by hydroxyl and hydroperoxyl radicals generated by Fe2+/Fe3+ redox reaction with hydrogen peroxide. Using multiple reaction monitoring, a GC–MS/MS method, incorporating isotopically labeled reference compounds, is used to quantify the expected derivatized species. The analytes are derivatized using trimethyl-3-trifluoromethyl phenyl ammonium hydroxide, and the derivatization yield of warfarin is determined by using isotopically labeled reference compounds. The method has a linear working range of 30 to 1800 ng/mL, with detection limits ranging from 18.7 to 67.0 ng/mL. The analytes are enriched using a C18-SPE step, and the recovery for each compound is calculated. The Fenton reaction generates all preselected hydroxylated transformation products of warfarin. The method successfully identifies that 4′-Me-O-WAR forms preferentially under the specified experimental conditions. By further optimizing the SPE clean-up procedures, this GC–MS-based method will be suitable for detecting transformation products in more complex matrices, such as environmental water samples. Overall, this study provides a better understanding of warfarin’s degradation and offers a robust analytical tool for investigating its transformation products.
The plant secondary metabolite families of coumarin and 4-hydroxy coumarin have a broad pharmacological spectrum ranging from antibacterial to anticancer properties. One prominent member of this substance class is the synthetic but naturally inspired anticoagulant drug and rodenticide warfarin (coumadin). A vast number of publications focus on the identification of warfarin and its major cytochrome P450-mediated phase I metabolites by liquid chromatography (LC) with mass spectrometry (MS) and tandem mass spectrometric (MS/MS) detection techniques. For the first time, electron ionization (EI) induced high-resolution quadrupole time-of-flight mass spectrometric (HR-qToF-MS) data of in-liner derivatized warfarin and selected hydroxylated species is provided in this study as an alternative to LC-MS/MS approaches. Furthermore, the characteristic fragments and fragmentation pathways of the analyzed methyl ethers are concluded. The obtained data of analytical standards, specific deuterated and 13C-labeled compounds prove inductive cleavage of the acyl or acetonyl side chain, methyl migration, and H-migration, along with consequential inductive cleavage as predominant fragmentation routes. Based on the HR-spectral data, commonalities and differences between the analyzed compounds and fragment groups were evaluated with future applicability in structure elucidation and spectra prediction of related compounds.
The electron density and temperature of a laser-induced plasma can be determined from the width and intensity of the spectral lines, provided that the corresponding optical transitions are optically thin. However, the lines in laser induced plasma are often self-absorbed. One of the methods of correction of this effect is based on the use of the Planck function and an iterative numerical calculation of the plasma temperature. In this study, the method is further explored and its inherent errors and limitations are evaluated. For this, synthetic spectra are used that fully correspond to the assumed conditions of a homogeneous isothermal plasma at local thermodynamic equilibrium. Based on the error analysis, the advantages and disadvantages of the method are discussed in comparison with other methods of self-absorption correction.
The Boltzmann plot is one of the most widely used methods for determining the temperature in different types of laboratory plasmas. It operates on the logarithm as a function of the dimensional argument, which assumes that the correct physical units are used. In many works using the Boltzmann method, there is no analysis of the dimension of this argument, which may be the cause of a potential error. This technical note offers a brief description of the method and shows how to correctly use physical units when using transcendental functions like the logarithm.
Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, EDS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids were used to introduce functional groups for further conjugations. The common crosslinker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter was oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower non-specific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). A binding capacity of 1.8 mg IgG per gram of corundum powder was achieved. The advantages of corundum include the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, convenient handling, and flexible application.
Immobilized metal affinity chromatography (IMAC) is a widely used technique for purifying polyhistidine-tagged recombinant proteins. However, it often has practical limitations that require complex optimizations and additional steps for purification. In this study, we introduce functionalized corundum particles as a novel, efficient, and economical method for purifying recombinant proteins in a column-free format. The corundum surface is modified with amino silane APTES, followed by EDTA dianhydride, and then loaded with nickel ions. We used the Kaiser test to monitor the modification process and ICP-MS to quantify the metal-binding capacity. To evaluate the system, we used His-tagged protein A/G (PAG) mixed with bovine serum albumin (BSA). The corundum particles exhibited a binding capacity of approximately 3 mg of protein per gram of corundum or 2.4 mg per 1 mL of corundum suspension. We also examined cytoplasm obtained from different E. coli strains as an example of a complex matrix. Varying the imidazole concentration in the loading and washing buffers showed that higher concentrations during loading improved purity. Even with sample volumes as large as one liter, we successfully isolated recombinant proteins down to a concentration of 1 µg/mL. We found higher purity levels with corundum when comparing the corundum material to standard Ni–NTA agarose beads. We successfully purified His6-MBP-mSA2, a fusion protein comprising monomeric streptavidin and maltose-binding protein, from E. coli cytoplasm, demonstrating the method's applicability. We also purified SARS-CoV-2-S-RBD-His8 expressed in human Expi293F cells, confirming its suitability for mammalian cell culture supernatants. The material cost of the nickel-loaded corundum material (without regeneration) is estimated to be less than 30 cents per gram of functionalized support or 10 cents per milligram of isolated protein. Another advantage of this system is the exceptional physical and chemical stability of corundum particles. Overall, we have demonstrated that this novel material offers an efficient, robust, and cost-effective purification platform for His-tagged proteins, even in challenging, complex matrices and large sample volumes with low product concentrations. This method has potential applications in both small laboratories and large-scale industrial settings.
Near-infrared (NIR) spectroscopy is a promising candidate for low-cost, nondestructive, and highthroughput mass quantification of microplastics in environmental samples. Widespread application of the technique is currently hampered mainly by the low sensitivity of NIR spectroscopy compared to thermoanalytical approaches commonly used for this type of analysis. This study shows how the application of NIR spectroscopy for mass quantification of microplastics can be extended to smaller analyte levels by combining it with a simple and rapid microplastic enrichment protocol. For this purpose, the widely used flotation of microplastics in a NaCl solution, accelerated by centrifugation, was chosen which allowed to remove up to 99 % of the matrix at recovery rates of 83–104 %. The spectroscopic measurements took place directly on the stainless-steel filters used to collect the extracted particles to reduce sample handling to a minimum. Partial least squares regression (PLSR) models were used to identify and quantify the extracted microplastics in the mass range of 1–10 mg.
The simple and fast extraction procedure was systematically optimized to meet the requirements for the quantification of microplastics from common PE-, PP-, and PS-based packaging materials with a particle size < 1 mm found in compost or soils with high natural organic matter content (> 10 % determined by loss on ignition). Microplastics could be detected in model samples at a mass fraction of 1 mg g-1. The detectable microplastic mass fraction is about an order of magnitude lower compared to previous studies using NIR spectroscopy without additional enrichment. To emphasize the cost-effectiveness of the method, it was implemented using some of the cheapest and most
compact NIR spectrometers available.