Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (2052) (entfernen)
Sprache
- Englisch (2052) (entfernen)
Schlagworte
- Additive manufacturing (64)
- Fluorescence (56)
- SAXS (46)
- Nanoparticles (45)
- MALDI-TOF MS (37)
- Concrete (36)
- Quantum yield (36)
- Corrosion (35)
- Mechanochemistry (29)
- Polylactide (29)
Organisationseinheit der BAM
- 6 Materialchemie (437)
- 1 Analytische Chemie; Referenzmaterialien (346)
- 8 Zerstörungsfreie Prüfung (305)
- 5 Werkstofftechnik (206)
- 9 Komponentensicherheit (201)
- 7 Bauwerkssicherheit (186)
- 4 Material und Umwelt (177)
- 6.3 Strukturanalytik (167)
- 8.5 Röntgenbildgebung (118)
- 6.1 Oberflächen- und Dünnschichtanalyse (97)
Paper des Monats
- ja (71)
A novel synthetic strategy toward highly fluorinated BODIPY dyes with exceptional photostabilities relying on sustainable gold catalysis has been developed. A key to the tailored pyrrole precursors is the gold catalysis performed in ionic liquids as the reaction medium, allowing a facile recycling of the catalysts. The dyes prepared are well-matching with the spectral windows of popular rhodamine dyes and possess high brightness while showing a distinctly higher photostability than the rhodamines especially in aprotic solvents.
The demands for the assessment of water quality are increasing steadily, making it necessary to routinely monitor multiple contaminants in water samples. For this application a hapten microarray was developed. In order to reach the required low detection limits a design of experiments (DoE) approach was used to optimize the assay performance. Here we show that a Box-Behnken design plan is an adequate choice for the straightforward exploration of hapten microarray assay parameters. For both read-out systems studied (fluorophore-labelled detection antibodies or enzymatic signal development followed by reflectometric scan, respectively), it was possible to significantly extend the measurement ranges. Furthermore, it could be shown that multivariate data analysis, here partial least squares regression (PLS), can improve the prediction accuracy of 'unknown' samples when used as calibration model, compared to classical, univariate data evaluation methods.
Geophysical methods have been used in civil engineering for decades. The main field of application is - to no surprise – in geotechnical projects from site characterization to foundation quality assurance. For more than 25 years, ground penetrating radar (GPR) and seismic methods have found applications in structural engineering. Recently introduced geophysical methods have been adopted to ultrasonic investigations in various fields. They help to improve the quality of structural imaging and to detect small changes in concrete. An overview of the history and current use of geophysics in civil engineering is given. Selected examples of new concepts include advances in wave based imaging, quality assurance for foundations, detecting small changes in concrete as well as moisture and corrosion detection are discussed.
Challenging new constructions and ageing infrastructure are increasing the demand for permanent monitoring of loads and condition. Various methods and sensors are used for this purpose. But the technologies available today have difficulties in detecting slowly progressing locally confined damages. Extensive investigations or instrumentations are required so far for this purpose. In this study we present new sensors and data processing methods for ultrasonic transmission, which can be used for non-destructive long term monitoring of concrete. They can be mounted during construction or thereafter. Larger volumes can be monitored by a limited number of sensors for changes of material properties. The principles of ultrasonic transmission and influencing factors are presented. This latter include load, damages as well as environmental parameters as temperature or moisture. Various methods for data processing, e. g. coda wave interferometry are introduced. They allow the detection of very small changes in the medium. The embedded sensors are shown including mounting and operation. Application examples so far include small scale laboratory freeze-thaw experiments, localizing loads in larger concrete models, monitoring load effects on real structures as well as detecting acoustic events. Some sensors are operating already for several years. The sensors can be used as transmitter or receivers or switched between both roles. While most of the previous experiments have been active (at least one sensor serving as transmitter), new studies show that the sensors are useful as well for passive measurements, e. g. in acoustic emission or time reversal experiments. Besides application in civil engineering our setups can also be used for model studies in geosciences.
SASfit: a tool for small-angle scattering data analysis using a library of analytical expressions
(2015)
SASfit is one of the mature programs for small-angle scattering data analysis and has been available for many years. This article describes the basic data processing and analysis workflow along with recent developments in the SASfit program package (version 0.94.6). They include (i) advanced algorithms for reduction of oversampled data sets, (ii) improved confidence assessment in the optimized model parameters and (iii) a flexible plug-in system for custom user-provided models. A scattering function of a mass fractal model of branched polymers in solution is provided as an example for implementing a plug-in. The new SASfit release is available for major platforms such as Windows, Linux and MacOS. To facilitate usage, it includes comprehensive indexed documentation as well as a web-based wiki for peer collaboration and online videos demonstrating basic usage. The use of SASfit is illustrated by interpretation of the small-angle X-ray scattering curves of monomodal gold nanoparticles (NIST reference material 8011) and bimodal silica nanoparticles (EU reference material ERM-FD-102).
This paper gives a brief overview on3D imaging of magnetic domains with shearing grating neutron tomography. We investigated the three-dimensional distribution of magnetic domain walls in the bulk of a wedge-shaped FeSi single crystal. The width of the magnetic domains wasanalyzed at different locations within the crystal. Magnetic domains close to the tip of the wedge are much smaller than in the bulk. Furthermore, the three-dimensional shape of individual domains wasinvestigated. We discuss prospects and limitations of the applied measurement technique.
Melt flow and dripping of the pyrolysing polymer melt can be both a benefit and a detriment during a fire. In several small-scale fire tests addressing the ignition of a defined specimen with a small ignition source, well-adjusted melt flow and dripping are usually beneficial to pass the test. The presence of flame retardants often changes the melt viscosity crucially. The influence of certain flame retardants on the dripping behaviour of four commercial polymers, poly(butylene terephthalate) (PBT), polypropylene (PP), polypropylene modified with ethylene-propylene rubber (PP-EP) and polyamide 6 (PA 6), is analysed based on an experimental monitoring of the mass loss due to melt dripping, drop size and drop temperature as a function of the furnace temperature applied to a rod-shaped specimen. Investigating the thermal transition (DSC), thermal and thermo-oxidative decomposition, as well as the viscosity of the polymer and collected drops completes the investigation. Different mechanisms of the flame retardants are associated with their influence on the dripping behaviour in the UL 94 test. Reduction in decomposition temperature and changed viscosity play a major role. A flow limit in flame-retarded PBT, enhanced decomposition of flame-retarded PP and PP-EP and the promotion of dripping in PA 6 are the salient features discussed.
This paper reflects recent progress in the field of fluorescent polymer optical fiber sensors (F-POF) for partial discharge (PD) detection in high voltage (HV) cable accessories using optical-only PD detection by coincidence single photon counting. In experiments with artificial PD sources these sensors show the ability to detect optical emissions from picocoulomb-level PDs in a real-scale model of a translucent high voltage cable accessory. False positives (caused by detector noise) are efficiently suppressedwhile maintaining sufficient sensitivity,even when the sensor is located in an unfavorable position.
N-Hydroxysuccinimide (NHS) esters are the most important activated esters used in many different bioconjugation techniques, such as protein labelling by fluorescent dyes and enzymes, surface activation of chromatographic supports, microbeads, nanoparticles, and microarray slides, and also in the chemical synthesis of peptides. Usually, reactions with NHS esters are very reliable and of high yield, however, the compounds are sensitive to air moisture and water traces in solvents. Therefore, the quantification of NHS would be a very helpful approach to identify reagent impurities or degradation of stored NHS esters. No robust and sensitive method for the detection of NHS (or the more hydrophilic sulfo-NHS) has been reported yet. Here, a chromatographic method based on HILIC conditions and UV detection is presented, reaching a detection limit of about 1 mg L-1, which should be sensitive enough for most of the applications mentioned above. Exemplarily, the hydrolytic degradation of a biotin-NHS ester and a purity check of a fluorescent dye NHS ester are shown. An important advantage of this approach is its universality, since not the structurally variable ester compound is monitored, but the constant degradation product NHS or sulfo-NHS, which avoids the necessity to optimize the separation conditions and facilitates calibration considerably.
In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study.