Wissenschaftliche Artikel der BAM
Filtern
Dokumenttyp
Schlagworte
- Monitoring (2)
- Acoustic emission (1)
- Coda wave interferometry (1)
- Concrete (1)
- Cracks (1)
- Damages (1)
- Embedded sensors (1)
- SHM (1)
- Stress (1)
- Transducers (1)
Recently developed new transducers for ultrasonic transmission, which can be embedded right into concrete, are now used for non-destructive permanent monitoring of concrete. They can be installed during construction or thereafter. Large volumes of concrete can be monitored for changes of material properties by a limited number of transducers. The transducer design, the main properties as well as installation procedures are presented. It is shown that compressional waves with a central frequency of 62 kHz are mainly generated around the transducer's axis. The transducer can be used as a transmitter or receiver. Application examples demonstrate that the transducers can be used to monitor concrete conditions parameters (stress, temperature,
) as well as damages in an early state or the detection of acoustic events (e.g., crack opening). Besides application in civil engineering our setups can also be used for model studies in geosciences.
Challenging new constructions and ageing infrastructure are increasing the demand for permanent monitoring of loads and condition. Various methods and sensors are used for this purpose. But the technologies available today have difficulties in detecting slowly progressing locally confined damages. Extensive investigations or instrumentations are required so far for this purpose. In this study we present new sensors and data processing methods for ultrasonic transmission, which can be used for non-destructive long term monitoring of concrete. They can be mounted during construction or thereafter. Larger volumes can be monitored by a limited number of sensors for changes of material properties. The principles of ultrasonic transmission and influencing factors are presented. This latter include load, damages as well as environmental parameters as temperature or moisture. Various methods for data processing, e. g. coda wave interferometry are introduced. They allow the detection of very small changes in the medium. The embedded sensors are shown including mounting and operation. Application examples so far include small scale laboratory freeze-thaw experiments, localizing loads in larger concrete models, monitoring load effects on real structures as well as detecting acoustic events. Some sensors are operating already for several years. The sensors can be used as transmitter or receivers or switched between both roles. While most of the previous experiments have been active (at least one sensor serving as transmitter), new studies show that the sensors are useful as well for passive measurements, e. g. in acoustic emission or time reversal experiments. Besides application in civil engineering our setups can also be used for model studies in geosciences.
Für Ultraschallmessungen in Betonbauteilen wurden neuartige radialsymmetrisch abstrahlende Longitudinalwellenprüfköpfe mit einer Mittenfrequenz von 60 kHz auf deren Eignung hinsichtlich Abstrahlcharakteristik, Empfindlichkeit und Frequenzspektrum untersucht.
Für die Messung der Abstrahlcharakteristiken wurden die Prüfköpfe vertikal und horizontal in Betonzylinder eingebettet und die Richtungsabhängigkeiten der Schallschnelle mithilfe eines Laservibrometers gemessen.
Die Streuung der Prüfkopfempfindlichkeit wurde im Wasserbad unter Verwendung verschiedener Köpfe gleicher Bauart bestimmt. Außer Änderungen der Signalamplituden zeigten sich auch Schwankungen im Frequenzbereich bei verschiedenen Sender-Empfängerkombinationen.
Die Schallschwächung des Betons hat Einfluss auf die erreichbare Auflösung der Messungen und damit auf die maximal möglichen Senderabstände im Bauteil. Durch experimentelle Untersuchungen und Simulationen erfolgte eine Optimierung der Abstände hinsichtlich des Aufwandes und der geforderten Auflösung. Die Signalschwächung im Beton wurde mit verschiedenen Impulsen im Frequenzbereich von 50 kHz bis 100 kHz in Abhängigkeit verschiedener Bewehrungsgrade und Korngrößen ermittelt. Hierfür wurden die Sensoren in unterschiedlichen Abständen in die Probekörper einbetoniert und die Empfangssignale hinsichtlich Amplitudenabfall und Frequenzspektrum untersucht.