Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2017 (33) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (33) (entfernen)
Schlagworte
- Zerstörungsfreie Prüfung (5)
- CFK (4)
- Aktive Thermografie (3)
- Reliability (3)
- Air-coupled (2)
- CONSENS (2)
- Experimental testing (2)
- Online NMR Spectroscopy (2)
- Process Monitoring (2)
- SAFT (2)
A finite element tearing and interconnecting (FETI) approach for phase-field models and Gradient enhanced damage models is presented. These diffusive crack models can solve fracture mechanics problems by integrating a set of partial differential equations and thus avoid the explicit treatment of discontinuities. However, they require a fine discretization in the vicinity of the crack. FETI methods distribute the computational cost among multiple processors and thus speed up the computation.
Damage caused by stress concentrations in the complex mesoscopic geometry of concrete leads to continuous stress redistribution over the material’s life time. The presented fatigue damage model
captures this by resolving each load cycle in a cycle-by-cycle time integration. The model extends a static damage model to failure caused by the (time dependent) strain amplitudes and, thus, allows calibrating the majority of the material’s parameters in static experiments.
The heterogeneous mesostructure of concreted causes local stress concentrations. Stress dependent phenomena like damage and creep as well as their interactions are effected by those stress
concentrations. Therefore a material model’s macroscopic behavior will differ whether the mesoscale structure is considered or not. The differences between the mesoscale approach and an homogeneous approach will be presented. The results are discussed with focus on the true materials behavior.
A coupled thermomechanical mesoscale model for concrete under heating is presented. When considering the heterogeneous structure under coupled loads, complex macroscopic material properties can be modelled using simple constitutive relations. For instance, damage evolution is directly driven by the incompatibility of thermal strains between matrix and aggregates. Without prescribing
fc = f(T), a decline in compressive strength with rising temperatures will be shown.
Proben mit einer Mittelkerbe aus Polyamid 66 mit 35% Gewichtsan-teil an Kurzglasfaser (PA-GF35) wurden im Spritzgießverfahren hergestellt und in einem ungeschädigten und durch Schwingbeanspruch geschädigten Zustand mittels Röntgenverfahren charakterisiert. Sowohl die Faserorientierungsverteilung als auch die Riss-/Mikrorissbildung wurden mit der Röntgenrefraktionstopographie in einem SAXS-Aufbau und dem Diffraction-Enhanced-Imaging am Synchrotron (BESSY II) analysiert. Beide Verfahren spiegeln in guter Übereinstimmung die Charakteristiken dieser Werkstoffklasse in Bezug auf die Fertigungsqualität und die Schädigungsme-chanismen wider.
Currently, research in chemical manufacturing moves towards flexible plug-and-play approaches focusing on modular plants, capable of producing small scales on-demand with short down-times between individual campaigns. This approach allows for efficient use of hardware, a faster optimization of the process conditions, and thus, an accelerated introduction of new products to the market. Driven mostly by the search for chemical syntheses under biocompatible conditions, so-called “click” chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques.
Here we report on a fast and reliable calibration-free online high field NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement with a time interval of 20 s per spectrum, and a robust, automated algorithm to interpret the obtained data. All spectra were acquired using a 500 MHz NMR spectrometer (Varian) with a dual band flow probe having a 1/16-inch polymer tubing working as a flow cell. Single scan 1H NMR spectra were recorded with an acquisition time of 5 s, relaxation delay of 15 s. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in non-deuterated solvents while its time-resolved behaviour was characterised with step tracer experiments.
Through the application of spectral modeling the signal area for each reactant can be deconvoluted in the online spectra and thus converted to the respective concentrations or molar ratios. The signals which were suitable for direct integration were used herein for comparison purposes of both methods.
Non-destructive testing (NDT) helps to find material defects without having an influence on the material itself. It is applied as a method of quality control, for online structural health monitoring, and for inspection of safety related components. Due to the ability of automation and a simple test setup ultrasonic testing is one major NDT technique next to several existing options. Whereas contact technique allows the use of higher frequencies of some MHz and phased array focusing, air-coupled ultrasonic testing (ACUT) shows different advantages. Most significant for ACUT is the absence of any coupling fluid and an economical test procedure respective time and costs. Both contact technique and ACUT have been improved and enhanced during the past years. One important enhancement is the development of airborne transducers based on ferroelectrets, like charged cellular polypropylene (cpp), which makes the application of any matching layers being mandatory in conventional piezoelectric transducers unnecessary. In this contribution we show ultrasonic inspection results of specimens made of carbon- and glass-fibre-reinforced plastic. These specimens include defects represented by drill holes and artificial delaminations of various size and depth. We compare inspection results achieved by using contact technique to those achieved by ACUT. For ACUT, conventional piezoelectric transducers and transducers based on cpp were used, both focused as well as non-focused types. Contact inspections were performed with a multi-channel matrix array probe. Once the inspection data is recorded it can be analysed in order to detect and evaluate defects in the specimen. We present different analysing strategies and compare these regarding detection rate and sizing of defects.
Im Bereich der optisch angeregten Thermografie haben sich Blitzlampen (impulsförmig-flächige Erwärmung) und Halogenlampen (moduliert-flächige Erwärmung) für die spezifischen Regime Impuls- und Lockin-Thermografie etabliert.
Mittels eines rasternden fokussierten Lasers wird die Flying-spot Laserthermografie z.B. zur Risserkennung (Dauerstrichbetrieb) und die photothermische Materialcharakterisierung (hochfrequent moduliert)implementiert. Durch die Verfügbarkeit neuer Technologien (schnelle und hochauflösende IR-Kameras, brillante innovativer Lichtquellen und performante Datenakquisitions- und Verarbeitungstechnik) wird ein Paradigmenwechsel von den getrennt voneinander stehenden photothermischen und
thermografischen Techniken hin zu einer einheitlichen quantitativen Mess-und Prüftechnik ermöglicht, die schneller und präziser ist. Ähnlich wie ein LED-Array, jedoch mit einer um zwei Größenordnungen höheren Bestrahlungsstärke, steht jetzt eine neuartige brillante Laserquelle, das VCSEL-Array (vertical-cavity surface-emitting laser) zur Verfügung, welches die starke Beschränkung der zeitlichen Dynamik der etablierten Lichtquellen aufhebt und gleichzeitig spektral sauber von der Detektionswellenlänge getrennt ist. Es vereint somit das schnelle zeitliche Verhalten eines Diodenlasers mit der hohen optischen Bestrahlungsstärke und dem großen Beleuchtungsbereich von Blitzlampen. Darüber hinaus kann die Erwärmung auch strukturiert vorgenommen werden, da einzelne Bereiche des VCSEL-Arrays unabhängig voneinander angesteuert werden können. Dieser neue Freiheitsgrad ermöglicht die Entwicklung ganz neuer thermografischer ZfP-Verfahren.
Classical film radiography is a well-established NDT technique and it is most commonly used for testing weld seams and corroded pipes e.g. in oil and gas industry or in nuclear power plants. In the course of digitization, digital detector arrays (DDA) are finding their way into industrial applications and are replacing film radiography step by step. This study deals with the latest generation of DDAs, the photon counting and energy resolving detectors (PCD), and their characteristics compared to charge integrating detectors (CID). No matter which technology to use, radiography still lacks a general issue: A three-dimensional object is projected onto a two dimensional image. Of course, advanced computed tomography (CT) algorithms exist since many years, but if the object to investigate is too large to fit into the manipulation system or its shape is not appropriate, CT is not feasible or sensible to be applied. To overcome this limitation, numerous laminographic algorithms have been developed in the past. In this study, photon counting detectors are used in combination with co-planar translational laminography to gain reconstructed three-dimensional volumes. Both laminographic testing and PCDs require a serious knowledge of many parameters that can influence the image quality in the resulting datasets. These are e.g. the detector efficiency and calibration procedure, setting of energy thresholds, exposure data, number of projections, beam length correction and spatial resolution. The use of PCDs yields more variables to be considered compared to CIDs. The most important parameters in laminographic testing and in the use of PCDs are described in this study and limits are discussed.
Im Bauwesen werden Polymerbeschichtungen auf Beton häufig eingesetzt um zum einen ein bestimmtes Aussehen zu schaffen und zum anderen das Bauteil vor Alterung, Verschleiß und Schädigung zu schützen. Für praktisch alle Ziele ist die Wirkung von der eigens dafür definierten Schichtdicke der Polymerbeschichtung abhängig. Daher wird die Dicke der Beschichtung nach erfolgtem Schichtauftrag überprüft. Für den in diesem Zusammenhang anspruchsvollen mineralischen Untergrund Beton stehen bislang allerdings nur zerstörende Prüfverfahren zur Verfügung. Aus diesem Grund wurden im Rahmen des Projektes IRKUTSK ein auf aktiver Thermografie basierendes Verfahren sowie ein Gerät für den vor-Ort-Einsatz entwickelt, mit dessen Hilfe eine zerstörungsfreie Schichtdickenbestimmung möglich ist.
Hier wird ein kurzer Einblick in das zur Schichtdickenbestimmung entwickelte Thermografieverfahren gegeben. Die Besonderheiten bei der quantitativen Auswertung, die durch die Teiltransparenz der Polymerbeschichtungen auftreten, werden erläutert. Die Funktion des Verfahrens für einlagige Systeme wird anhand von La-bormessungen illustriert.