Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2015 (21) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (21) (entfernen)
Sprache
- Deutsch (13)
- Englisch (7)
- Mehrsprachig (1)
Schlagworte
- Zerstörungsfreie Prüfung (3)
- GMR (2)
- Streuflussprüfung (2)
- Strukturüberwachung (2)
- Thermografie (2)
- Ultraschallprüfung (2)
- Aerospace (1)
- Aktive Thermografie (1)
- Aluminium Druckguss (1)
- Blitzthermografie (1)
Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectros-copy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical com-parison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory.
CONRAD-2 is an imaging instrument using low-energy (cold) neutrons. The instrument is installed at the end of a curved neutron guide which avoids the direct line of sight towards the reactor core. This ensures a very low background of high-energy neutrons and. photons at the sample position. The cold neutron beam provides a wavelength range which is suitable for phase-and diffraction-contrast imaging such as grating interferometry and Bragg edge mapping. The instrument is well suited for high resolution imaging due to the high efficiency of the very thin scintillators that can be used for the detection of cold neutrons. An instrument upgrade was performed recently as a part of an upgrade program for the cold neutron instrumentation at HZB. The parameters of the instrument as well as some research highlights will be presented.
Several ultrasonic approaches for material determination are formulated in terms of an (nonlinear) inverse problem, e.g. immersion technique (Castaings et al. (2000)) or plate-waveguide techniques (Marzani et al. (2012)). In this contribution we focus on cylindrical waveguides for ultrasonic material determination and especially on the sensitivity of recorded transmission signals to the material properties. We utilize composite scaled sensitivities to determine the information content that can be achieved by the setup to certain parameters and discuss the limitations of the approach.
Für die Prüfung von Leichtbaustrukturen ist in den letzten Jahren ein vermehrter Einsatz der Luftultraschallprüfung zu verzeichnen. Insbesondere eignet sich Luftultraschall für die Prüfung von Faserkunststoffverbunden und hybrider Werkstoffverbunde, die ihre Anwendung in der Automobilindustrie und Luftfahrt finden. Für den Bau von marktüblichen Luftultraschall-Wandlern werden Piezokomposite mit Anpassschichten versehen. Ihre Herstellung ist allerdings sehr anspruchsvoll und die erreichbaren Signal-Rausch-Abstände sind für viele Prüfprobleme als noch nicht ausreichend einzustufen. Zwecks gesteigerter Effizienz beim Schallübertrag in die Luft wurden Luftultraschall-Sender und -Empfänger aus zellulärem Polypropylen entwickelt. Dieses piezoelektrische Material ist aufgrund seiner geringer Dichte und seiner sehr geringen Schallgeschwindigkeit an die niedrige akustische Impedanz der Luft deutlich besser angepasst, als die üblicherweise verwendeten Anpassschichten. Letztere können bei Polypropylen-Wandlern daher gänzlich vermieden werden.
In diesem Beitrag wird Luftultraschall-Prüfung an zwei verschiedenen CFK-Testkörpern vorgestellt: an einer Platte mit T-Stringern aus dem Seitenleitwerk eines Flugzeugs und an einer Platte mit künstlich eingebrachten Fehlern. Es wurde mit unterschiedlichen planaren und fokussierenden Wandlern geprüft. Marktübliche Wandler mit Anpassschichten wurden mit den selbstentwickelten Wandlern aus zellulärem Polypropylen verglichen. Der Signal-Rausch-Abstand und die laterale Auflösung wurden sowohl im Prüfaufbau mit senkrechter Einschallung als auch mit Schrägeinschallung gemessen. Die Ergebnisse zeigen, dass die Schrägeinschallung zwar den Signal-Rauschabstand erhöht, aber die laterale Auflösung verschlechtern kann.
Die Zahl der industriellen Anwendungen mit Einsatz von Faserverbundwerkstoffen wächst kontinuierlich vor allem wegen der exzellenten Materialeigenschaften und des geringen Gewichtes dieses Werkstoffes. Entsprechend steigen die Anforderungen an zerstörungsfreie Prüfsysteme zur Gewährleistung des sicheren Betriebes von Komponenten und Strukturen bestehend aus Verbundwerkstoffen.
Im Rahmen des EU-Projekes VITCEA (Validated Inspection Techniques for Composites in Energy Applications) wird das Ziel verfolgt, neue Prüfverfahren für moderne Verbundwerkstoffe zu entwickeln und zu validieren. Im Vordergrund steht hierbei als Applikation im Industriesektor Energieversorgung die Prüfung von sicherheitsrelevanten Komponenten von onshore und offshore Windkraftanlagen, wie z.B. deren Rotorblätter und tragende Strukturen.
Eine Teilaufgabe innerhalb des Projektes stellen der Vergleich und die Validierung verschiedener Ultraschallprüfmethoden bezüglich ihrer Fähigkeit zum Nachweis der typischen Herstellungs- und betriebsbedingten Materialschädigungen von CFK und GFK dar.
Neben verschiedenen konventionellen Ultraschall-Prüftechniken, werden die Phased-Array-Prüfung, insbesondere die Prüfung mit Matrixarrays, sowie die Untersuchung mit berührüngsloser Luftultraschalltechnik bezüglich ihrer Nachweisgrenzen und der Möglichkeiten zur Fehlercharakterisierung an Faserverbundwerkstoffen untersucht. Die Ergebnisse werden mit Untersuchungen mit thermographischen Methoden und Mikrowellentechnik verglichen.
Defect detection in concrete pile using impulse response measurements with sine sweep excitations
(2015)
For pile integrity inspection, a low cost and portable shaker was used to create the sine sweep signal for pile excitation. The impulse response function, calculated by the deconvolution of pile response from the sine sweep excitation, was proposed to identify the echoes in the piles due to the pile’s impedance changes. The proposed methodology has been evaluated and validated both numerically and experimentally. Based on the results from the simulations and experiments, it was found that the impulse response measurement with sine sweep excitation could be an effective tool to detect the echoes of the pile toe and the defects in the pile.
Die Blitzthermografie weist eine Reihe von Vorteilen gegenüber anderen Verfahren der aktiven Thermografie auf und hat daher eine relativ große Verbreitung in Forschung und Industrie gefunden. Ein wesentlicher Nachteil ist jedoch die begrenzte Energie, die pro Blitz genutzt werden kann. Es stellt sich die Frage, ob sich durch mehrere kurz hintereinander ausgeführte Blitze eine Verbesserung des Energieeintrags erreichen lässt. Zur experimentellen Untersuchung dieser Frage wurde ein Versuchsstand mit vier Blitzlampen so umgerüstet, dass die Blitzlampen zeitgleich oder nacheinander mit einer regelbaren Verzögerung ausgelöst werden können („Multiblitz“). Als Probekörper dienten Platten aus CFK, an deren Rückseite Flachbodenbohrungen (FBB) eingebracht worden waren. Betrachtet wurde jedoch nur der absolute Temperaturhub am ungestörten Material. Die Experimente zeigen relativ geringe Effekte im Prozentbereich, wie sie auch gemäß einer quantitativen Abschätzung zu erwarten sind. Interessanterweise vergrößerte sich der Einfluss der Multiblitzanregung auf die Energieeinkopplung deutlich bei einem etwas vergrößerten Abstand zwischen Blitzlampen und untersuchter Oberfläche. Die Ursache für diesen Effekt ist derzeit unklar, vermutet werden eine Temperaturabhängigkeit und/oder eine Abstandsabhängigkeit des Wärmübergangskoeffizienten im Konvektionsterm.
Im Rahmen des INS-Projekts „Durchführung von Ringversuchen zur Normung und Standardisierung der aktiven Thermografie mit Blitzlichtanregung“ wurden Ringversuche durchgeführt, die die Zuverlässigkeit, Vergleichbarkeit und Effektivität der Blitzthermografie für unterschiedliche Prüfprobleme nachweisen sollten. Weiterhin sollten diese Untersuchungen als Methodenvalidierungsstudie die Richtigkeit und Präzision der Blitzthermografie nachweisen und Vergleichsinformationen unterschiedlicher Geräteausstattungen liefern. Im Normausschuss NA 062-08-27 AA „Visuelle und thermografische Prüfung“ des DIN werden die Ergebnisse die Erarbeitung eines Normentwurfs zur Blitzthermografie unterstützen. In diesem Beitrag werden die Ringversuche beschrieben und ausgewählte Ergebnisse präsentiert.
Ultrasonic echo testing is widely used in non-destructive testing in civil engineering to investigate concrete structures, to measure thickness, and to locate and characterise built-in components or inhomogeneities. Currently, synthetic aperture focusing techniques are mostly used for imaging. These algorithms are highly developed but have some limitations. For example, it is not possible to image the lower boundary of built-in components like tendon ducts or vertical reflectors. We adopted reverse time migration for non-destructive testing in civil engineering in order to improve the imaging of complicated structures in concrete. By using the entire wavefield, including waves reflected more than once, there are fewer limitations compared to synthetic aperture focusing technique algorithms. As a drawback, the required computation is significantly higher than that for the techniques currently used. Simulations for polyamide and concrete structures showed the potential for non-destructive testing. The simulations were followed by experiments at a polyamide specimen. Here, having acquired almost noise-free measurement data to test the algorithm, we were able to determine the shape and size of boreholes with sufficient accuracy. After these successful tests, we performed experiments at a reinforced concrete foundation slab. We obtained information from the data by reverse time migration, which was not accessible by traditional imaging. The imaging of the location and structure of the lower boundary of the concrete foundation slab was improved. Furthermore, vertical reflectors inside the slab were imaged clearly, and more flaws were found. It has been shown that reverse time migration is a step forward in ultrasonic testing in civil engineering.
Aktive Thermografieverfahren werden immer häufiger zur zerstörungsfreien Prüfung von Faserverbundwerkstoffen eingesetzt, da diese völlig berührungslos arbeiten und sowohl zur Prüfung großflächiger Strukturen als auch von großen Stückzahlen kleinerer Komponenten in der Fertigung eingesetzt werden können. Dieser Beitrag beschäftigt sich mit Untersuchungen an typischen Defekten und Inhomogenitäten, die bereits während der Fertigung von CFK Bauteilen entstehen oder unbeabsichtigt mit eingebaut werden. Systematische Untersuchungen wurden mit Blitzthermografie in Reflexions- und Transmissionskonfiguration und mit Computertomographie (CT) durchgeführt. Die CT wurde dabei als Referenzverfahren genutzt, da dieses Verfahren auch kleinere Defekte mit relativ hoher Ortsauflösung und unabhängig von der Tiefe darstellen kann.