Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2014 (68) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (48)
- Beitrag zu einem Tagungsband (17)
- Forschungsbericht (2)
- Sonstiges (1)
Schlagworte
- NDT (4)
- Digital detector array (DDA) (3)
- Zerstörungsfreie Prüfung (3)
- Aktive Thermografie (2)
- Betatron (2)
- Computertomographie (CT) (2)
- DIRECTT (2)
- DNA radiation damage (2)
- Graphene (2)
- Image quality (2)
This survey will discuss current and emerging isothermal and rapid polymerase chain reaction (PCR) based nucleic acid amplification methods for patient near diagnostics. To assess the clinical need of rapid diagnostics for infectious diseases based on nucleic acid tests (NATs) we performed and analysed a questionnaire among laboratories participating in corresponding INSTAND ring trials for external quality assurance. The questions concerning new amplification technologies like isothermal nucleic acid amplification, potentially suited to significantly decrease turnaround times, were complemented by questions to evaluate the present status of NATs. Besides end-users, companies were also addressed by sending out a manufacturer specific questionnaire. Analysis of the answers from 48 laboratories in 14 European countries revealed that a much shorter turnaround time is requested for selected pathogens compared to about 2 h or longer when applying temperature cycling amplification, i.e. PCR. In this context, most frequently mentioned were MRSA, norovirus, influenza A and B viruses, cytomegalovirus (CMV) as well as hepatitis B virus (HBV) and hepatitis C virus (HCV). At present, 8% of the laboratories having participated in this survey apply isothermal amplification of nucleic acid to identify infectious pathogens.
Über die Entwicklung von Anwendungsregeln für reaktive Brandschutzsysteme auf Stahlzuggliedern
(2014)
Der vorliegende Beitrag stellt den Entwicklungsstand von Anwendungsregeln für reaktive Brandschutzsysteme auf Stahlzuggliedern zusammenfassend dar. Dabei wird insbesondere auf die jüngsten Veränderungen in den normativen Grundlagen und bauaufsichtlichen Regelungen eingegangen und im Hinblick auf Sicherheitsaspekte bewertet.
Die Verringerung der Teilsicherheit für den Bauteilwiderstand nicht stabilitätsgefährdeter Bauteile im Regelwerk für die Kaltbemessung von Stahltragwerken ist hier als besonders kritisch anzusehen, da hierdurch ein systematisches Sicherheitsdefizit für den Brandfall verursacht wird.
Weiterhin werden neuste Forschungsergebnisse bei der Entwicklung von Bewertungsregeln von reaktiven Brandschutzsystemen auf Vollkreisprofilen unter Zugbeanspruchung vorgestellt und diskutiert. Die Untersuchungen behandeln die Fragestellung, inwieweit Prüfungen mit Zugbeanspruchungen an Kreisvollprofilen erforderlich sein werden.
Sollten CT Aufnahmen quantitativ und automatisch ausgewertet werden, ist die Qualität der Tomogramme ein wesentlicher Punkt. Außerdem steht bei Serienmessungen nur eine begrenzte Meßzeit für jede Probe. Es werden die verschiedenen Mikrofokusröhren in Bezug auf die Parameter Orts- und Dichteauflösung, sowie Meßzeit verglichen, CT Beispiele dazu gezeigt.
The synthesis of the polymorphic cocrystal caffeine:anthranilic acid was investigated to obtain a better understanding of the processes leading to the formation of different polymorphic forms. In the case of these cocrystal polymorphs synthesized by liquid-assisted grinding a distinct influence of the dipole moment of the solvent was found. A pre-coordination between the solvent molecules and the caffeine:anthranilic acid cocrystal could be identified in the formation of form II. In the case of form II the solvent can be regarded as a catalyst. The formation pathway of each polymorph was evaluated using synchrotron X-ray diffraction.
Fourier-Spektroskopische Untersuchungen von hochmolekularem Polyethylen (HMW-PE) und ultrahochmolekularem Polyethylen (UHMW-PE) im Mittleren - und Fernen Infrarotbereich können Veränderungen der molekularen Strukturen nachweisen, die durch Co60 γ-Strahlung und Rekristallisationsprozesse initiiert werden. UHMW-PE und HMW-PE sind im gewählten IR-Bereich unterscheidbar. Die integrale Absorption der B1u – Gitterschwingungen im Fernen Infrarotbereich (THz-Bereich) ermöglichen die quantitative Beschreibung des Kristallinitätsgrades und dessen Abbau. Die Bildung ungesättigter Vinylengruppen und der Abbau ungesättigter Methylengruppen können im Mittleren Infrarotbereich nachgewiesen werden.
Geführte Ultraschallwellen bieten eine Vielzahl von Einsatzmöglichkeiten in der Zerstörungsfreien Prüfung, der Zustandsüberwachung sowie der Materialcharakterisierung. Insbesondere für Rohrleitungen und ausgedehnte Plattenstrukturen ist eine Vielzahl von auf geführten Wellen basierenden Verfahren in der Entwicklung und teilweise bereits im Einsatz. Aufgrund des komplexen Ausbreitungsverhaltens geführter Wellen werden numerische Verfahren (etwa die Finite Elemente Methode (FEM) oder die Randelementemethode (BEM)) zur Simulation der Wellenausbreitung sowie der Wechselwirkung mit Defekten in Wellenleitern angewendet. Diese Methoden sind für große Strukturen extrem rechenintensiv und umständlich in der Anwendung. Ein ungleich effizienteres Verfahren wurde kürzlich von den Autoren auf Grundlage der Scaled Boundary Finite Element Method entwickelt. Ein semi-analytischer Ansatz erlaubt die Modellierung beliebig ausgedehnter Strukturen bei extrem kurzen Rechenzeiten. Die Wechselwirkung geführter Wellen mit Rissen kann auf besonders elegante und exakte Weise beschrieben werden. Mit dieser Methode können die komplexen Vorgänge in Wellenleitern innerhalb weniger Sekunden modelliert werden.
The vibrational density of states of a series of homologous triphenylene-based discotic liquid crystals HATn (n = 5, 6, 8, 10, 12) depending on the length of the aliphatic side chain is investigated by means of inelastic neutron scattering. All studied materials have a plastic crystalline phase at low temperatures, followed by a hexagonally ordered liquid crystalline phase at higher temperatures and a quasi isotropic phase at the highest temperatures. The X-ray scattering pattern for the plastic crystalline phase of all materials shows a sharp Bragg reflection corresponding to the intercolumnar distance in the lower q-range and a peak at circa 17 nm-1 related to intracolumnar distances between the cores perpendicular to the columns as well as a broad amorphous halo related to the disordered structure of the methylene groups in the side chains in the higher q-range. The intercolumnar distance increases linearly with increasing chain length for the hexagonal columnar ordered liquid crystalline phase. A similar behaviour is assumed for the plastic crystalline phase. Besides n = 8 all materials under study exhibit a Boson peak. With increasing chain length, the frequency of the Boson peak decreases and its intensity increases. This can be explained by a self-organized confinement model. The peaks for n = 10, 12 are much narrower than for n = 5, 6 which might imply the transformation from a rigid system to a softer one with increasing chain length. Moreover the results can also be discussed in the framework of a transition from an uncorrelated to a correlated disorder with increasing n where n = 8 might be speculatively considered as a transitional state.
Die durch Brechung an Mikrostrukturen abgelenkte Röntgenstrahlung wird direkt zweidimensional abgebildet. Dazu werden Modellproben einfacher Geometrie (Fasern, Kapillaren, monodisperse Nano- und Mikropartikel) mit einem auf 50 µm kollimierten Synchrotronstrahl (20 keV) gescannt. Die nach den Regeln der geometrischen Optik an prismatischen und linsenartigen Grenzflächen abgelenkte Strahlung wird in etwa 3 Metern Entfernung von einem Flächendetektor mit 7 µm Ortsauflösung zusätzlich zu der ungestörten Resttransmission des Primärstrahls registriert. In der Abfolge der Radiogramme werden die lokalen Orientierungsänderungen der Probekörper-Grenzflächen bei deren Abtastung mit wenigen Mikrometern Schrittweite bildhaft verfolgt. Mit der hier erreichten Winkelauflösung von etwa 3 Bogensekunden (Streuvektor-Inkremente Δk = 10-3nm-1) kann bei 50 µm Ortsauflösung das Materialvolumen bezüglich innerer Grenzflächen mit Nanometer-Separation auch bei hohen Abtastraten unterhalb einer Sekunde pro Bild charakterisiert werden.
Bikontinuierliche poröse Keramiken für Filteranwendungen weisen eine komplizierte Mikrostruktur auf, in der Poren und Festkörperphase 'vermischt' sind. Mechanische, thermische sowie Filtereigenschaften können nur präzise bestimmt werden, wenn die Morphologie beider Phasen quantitativ angegeben werden kann. Hier werden unter Anwendung von 3D Computertomographie (CT) und verschiedenen Techniken, die auf der Röntgenrefraktion basieren, die Porosität und die Porenorientierung in keramischen Cordierit-Dieselpartikelfiltern bewertet. Dabei werden zur Auswertung der Tomogramme die Fouriertransformierten sowie eine neu entwickelte richtungssensitive Bildanalyse (DIVA, directional interface variance analysis) angewandt. Sowohl die genannten Messtechniken als auch der statistische Ansatz gestatten die Extraktion optional ortsaufgelöster oder gemittelter Werte. Es ergeben sich sehr gute Übereinstimmungen der experimentell ermittelten Porositätswerte mit Ergebnissen aus Quecksilberintrusionsversuchen als auch der ermittelten Porenorientierung im Vergleich zu publizierten Angaben zur kristallographischen Textur. Dies legt den Schluss nahe, dass die Kenntnis der Grenzflächen (zwischen Poren und Materie) genügt, die morphologischen Eigenschaften solcher Materialien hinreichend zu beschreiben.
Wir stellen eine Prozedur vor, mit der typische 'Missing Wedge' (MW)-Artefakte in CT-Rekonstruktionen effektiv unterdrückt werden können. Dazu wird der iterative DIRECTT-Algorithmus (Direkte Iterative Rekonstruktion Computertomographischer Trajektorien) mit einigen Zyklen diskreter Rekonstruktion eingesetzt. Die Kernfunktionen des Algorithmus', die wiederholte Auswahl und Gewichtung von Elementen einer Zwischenkonstruktion, werden beibehalten. Abgesehen von Sonderfällen der Röntgen- und Neutronentomographie tritt die MW-Restriktion (neben einer Vielzahl anderer) in Standardkonfigurationen der Elektronentomographie auf. Um den MW-Effekt isoliert zu untersuchen und beurteilen zu können, werden hier vollständige experimentelle Datensätze einer bekannten Porenstruktur um einen Sektor beschnitten sowie MW-Rekonstruktionen von Porenmodellen erzeugt. Die Ergebnisse werden mit zurzeit verbreiteten Algorithmen (Gefilterte Rückprojektion (FBP) und ART-Varianten) verglichen. Die Bewertung im Fourierraum zeigt, dass DIRECTT die fehlende Information im MW erfolgreich ergänzt. Zur quantitativen Bewertung der lokalen Rekonstruktionsqualität werden Methoden der räumlichen Statistik eingesetzt.