Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2014 (68) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (48)
- Beitrag zu einem Tagungsband (17)
- Forschungsbericht (2)
- Sonstiges (1)
Schlagworte
- NDT (4)
- Digital detector array (DDA) (3)
- Zerstörungsfreie Prüfung (3)
- Aktive Thermografie (2)
- Betatron (2)
- Computertomographie (CT) (2)
- DIRECTT (2)
- DNA radiation damage (2)
- Graphene (2)
- Image quality (2)
- Nanomaterial (2)
- Radiography (2)
- Raman spectroscopy (2)
- Rekonstruktionsalgorithmus (2)
- Standards (2)
- Statistische Bewertung (2)
- Ultrasonics (2)
- X-ray backscatter imaging (2)
- 'Click' reaction (1)
- 3D (1)
- 3D-Mikrostruktur (1)
- Abbildungsverfahren (1)
- Acoustic emission (1)
- Additive manufacturing (1)
- Adhesive joint (1)
- Aerospace applications (1)
- Air-based (1)
- Air-coupled (1)
- Ammonium polyphosphate (1)
- Ancestor of opportunistic pathogens & lichens (1)
- Anti-corrosion coatings (1)
- Anti-counterfeiting (1)
- Azide-terminated surfaces (1)
- Bacteria detection (1)
- Bacterial milking (1)
- Basic spatial resolution (1)
- Batch fermentation (1)
- Baustoffe (1)
- Beton (1)
- Bewehrung (1)
- Bifunctional MgF2 (1)
- Biocidal product (1)
- Black yeast (1)
- Brandschutz (1)
- CFK (1)
- CXC (1)
- Calciumfluorid (1)
- Calibration (1)
- Carbohydrates (1)
- Casting (1)
- Cellular polypropylene (1)
- Ceramic (1)
- Certified reference materials (1)
- Co-60 irradiation (1)
- Cobalt (1)
- Cohesive zone (1)
- Comparison of detectors (1)
- Computer-Tomographie (1)
- Computertomographie (1)
- Confirmatory methods (1)
- Conformation (1)
- Construction products (1)
- Container inspection (1)
- Continuous culture (1)
- Coordination (1)
- Cordierit (1)
- Crack propagation (1)
- Creep damage (1)
- Crystal structure (1)
- DFT simulations (1)
- DNA origami (1)
- DNA radiosensitizer (1)
- DNA transfer (1)
- Dangerous substance (1)
- Data fusion (1)
- Deconvolution (1)
- Density functional theory (1)
- Detection of dangerous materials (1)
- Detectors (1)
- Differential scanning calorimetry (1)
- Difficult-to-copy (1)
- Digital detector array (1)
- Digital detectors (1)
- Digital industrial radiology (1)
- Digital radiography (1)
- Digital radiology (1)
- Dissociative electron attachment (1)
- Dual-energy (1)
- Durability (1)
- Dünnschichttechnik (1)
- EXAFS (1)
- Ectoine excretion (1)
- Effective attenuation coefficient (1)
- Electrochromism (1)
- Electromagnetic rectification (1)
- Electromagnetic weld pool support (1)
- Ellipsometrie (1)
- Emission (1)
- Energy discrimination (1)
- Energy dispersive X-ray spectroscopy (EDX) (1)
- Engineering (1)
- Epimerization (1)
- Ergopeptide (1)
- European regulation (1)
- Europium (1)
- FTIR (1)
- FTIR spectroscopy (1)
- Fatigue strength (1)
- Fe3Al (1)
- Ferroelectret (1)
- Festkörperphysik (1)
- Feuchtemessung (1)
- Friction (1)
- Fungal cell-walls (1)
- Furan derivatives (1)
- G quadruplexes (1)
- GMR (1)
- Gabelsensor (1)
- Gemcitabine (1)
- Geophysik (1)
- Glass (1)
- Grain boundary sliding (1)
- Hard metal (1)
- Hartmann effect (1)
- High energy radiography (1)
- High temperatures (1)
- High-energy X-ray imaging (1)
- High-resolution transmission in SEM (TSEM) (1)
- Highly reinforced concrete (1)
- Hofmeister effect (1)
- Host guest molecules (1)
- Hybrid monte carlo (1)
- Hygromycin resistance (1)
- Industrial safety (1)
- Infectious diseases (1)
- Information carrier (1)
- Infrared and far-infrared spectroscopy (1)
- Inspection (1)
- Interface (1)
- Intumescence (1)
- Iron (1)
- Irradiation geometry (1)
- Isothermal nucleic acid amplification (1)
- Kohäsionsenergie (1)
- Kosmotrope (1)
- Large test fecility (1)
- Laser beam welding (1)
- Leaching (1)
- Lewis/Bronsted (1)
- Local structure (1)
- Localization (1)
- Lockin-Thermografie (1)
- Lumineszenz (1)
- Magnesium hydroxide (1)
- Magneto-optical sensor (1)
- Material discrimination (1)
- Materials characterization (1)
- Measurement method (1)
- Mechanochemically synthesis (1)
- Mesh routing (1)
- Metal magnetic memory (1)
- Metallo-supramolecular polyelectrolytes (1)
- Micro- and nanocapsules (1)
- Microencapsulated thermochromic pigments (1)
- Micromechanical model (1)
- Missing Wedge (1)
- Missing wedge (1)
- Modulus (1)
- Molecular dynamics (1)
- Molecular recognition at interfaces (1)
- Multi-hop (1)
- Multifuncitonal material systems (1)
- Mössbauer spectroscopy (1)
- N2-stripping (1)
- NAT (1)
- NDE (1)
- NEXAFS (1)
- NH3-TPD (1)
- Nanopartikel (1)
- Nanoscience (1)
- Nanotechnology (1)
- NbC (1)
- Neutron scattering (1)
- Niobium carbide (1)
- Non-destructuive testing (1)
- Nonlinear Equation of Motion (1)
- Nonlinear Finite Element Formulations (1)
- Nuclear power plant (1)
- Nucleic acid tests (1)
- Optische Konstanten (1)
- Ortsauflösung (1)
- Oscillation (1)
- Osmophobic effect (1)
- PCR (1)
- Photo counting (1)
- Plasma (1)
- Poly(ester urethane) (1)
- Polycrystal (1)
- Polyethylene (1)
- Polypropylene (1)
- Porenorientierung (1)
- Poröse Keramik (1)
- Potential method (1)
- Powder X-ray diffraction (XRD) (1)
- Powder bed (1)
- Powder diffraction measurements (1)
- Preferential exclusion (1)
- Progressive catalyst poisoning (1)
- Protein protection (1)
- Protoplasts (1)
- QR code carrier (1)
- Quantitative NMR (1)
- Quantum mechanics (1)
- Quellungsmessung (1)
- Questionnaire (1)
- Radar (1)
- Radiographic procedures (1)
- Radiographic testing (RT) (1)
- Reaktive Brandschutzsysteme (1)
- Reference materials (1)
- Requirements (1)
- Reverse Time Migration (1)
- Robot (1)
- Röhrenvergleich (1)
- Röntgenbeugung (1)
- Röntgenrefraktion (1)
- SAFT (1)
- SAMs (1)
- SR-microXRF (1)
- Scanning electron microscopy (SEM) (1)
- Screening methods (1)
- Security applications (1)
- Shape memory polymer (1)
- Short cracks (1)
- Sliding (1)
- Smart label (1)
- Sol-Gel-Synthese (1)
- Solid acids (1)
- Solid state NMR (1)
- Spectrum simulation (1)
- Stahlkonstruktion (1)
- State-of-the-art (1)
- Status report (1)
- Steel weldment (1)
- Strength (1)
- Stress-protective morphology (1)
- Stringer (1)
- Structural integrity (1)
- Sub-aerial biofilms (1)
- Surface (1)
- Synergy (1)
- TOF (1)
- Tank leaching test (1)
- Terbium (1)
- Thermal stability (1)
- Thermo-responsiveness (1)
- Thermochromic properties (1)
- Time reversal (1)
- Transducer (1)
- Treated wood (1)
- Tumor radiation therapy (1)
- Turbulent Wind Excitation (1)
- Twisted-slit collimator (1)
- Ultraschall (1)
- Ultraschallecho-Verfahren (1)
- Ultraschallprüfung mit Matrix-Sensoren (1)
- Ultrasonic testing (1)
- Unsharpness (1)
- Vacuum (1)
- Venetzungsdichte (1)
- Virus detection (1)
- WSN (1)
- Wear (1)
- X-Ray (1)
- X-ray scattering (1)
- XANES (1)
- XANES/EXAFS (1)
- Zugglieder (1)
- atomic force microscopy (1)
- biodegradable material (1)
- biomedical applications (1)
- caffeine (1)
- cocrystal (1)
- enzyme reactions (1)
- flexible plastics (1)
- in situ template (NaCl) (1)
- injection moulded (1)
- macroporous carbon (1)
- mechanochemical synthesis (1)
- protein binding (1)
- silica nanoparticles (1)
- single-molecule analysis (1)
- surface and in-depth inspection (1)
- synchrotron X-ray diffraction (1)
- synthesize heteroatom (1)
- thermal decomposition (1)
- thrombocyte adhesion (1)
- titania nanoparticles (1)
- “leaky” mutant (1)
We report on calibration standards of nanoparticles meeting the definition of a nanomaterial given by the European Commission (EU 2011) which are relevant for the characterisation methods applied in the NanoDefine project. We found that the Impact of nanoparticles is outstanding in the scientific literature. A number of 270.000 paper titles on nanoparticles are listed in the Web of Science data base. But surprisingly, the availability of suitable certified standard reference materials is scarce. Only a few sources were found. For example, BAM provides the database Nanoscaled Reference Materials at http://www.nano-refmat.bam.de/en/ in cooperation with the ISO/TC 229 Nanotechnologies. In addition, two publications from 2013 on nanoscale reference materials are available. Candidates of nano-(certified) reference materials from other ongoing or just finished FP6 and FP7 nano-metrology projects have been extracted from the Compendium of Projects in the European NanoSafety Cluster (Compendium NSC, 2013). Recommendations for selection of representative test materials and calibration standards for NanoDefine internal tasks, respectively, are also given.
The EU FP7 NanoDefine project was launched in November 2013 and will run until October 2017. The Project is dedicated to support the implementation of the EU Recommendation on the Definition of Nanomaterial
by the provision of the required analytical tools and respective guidance. Main goal is to develop a novel
tiered approach consisting of (i) rapid and cost-efficient screening methods and (ii) confirmatory measurement
methods. The "NanoDefiner" eTool will guide potential end-users, such as concerned industries and regulatory bodies as well as enforcement and contract laboratories, to reliably classify if a material is nano or not. To achieve this objective, a comprehensive inter-laboratory evaluation of the performance of current
characterisation techniques, instruments and software is performed. Instruments, software and methods are
further developed. Their capacity to reliably measure the size of particulates in the size range 1-100 nm and
above (according to the EU definition) is validated. Technical reports on project results are published to
reach out to relevant stakeholders, such as policy makers, regulators, industries and the wider scientific community, to present and discuss our goals and results, to ensure a continuous exchange of views,
needs and experiences obtained from different fields of expertise and application, and to finally integrate the resulting feedback into our ongoing work on the size-related classification of nanomaterials.
Industrial production of the cell protectant ectoine: protection mechanisms, processes, and products
(2014)
Bacteria, Archaea and Eukarya can adapt to Saline environments by accumulating compatible solutes in order to maintain an osmotic equilibrium. Compatible solutes are of diverse chemical structure (sugars, polyols, amino acid derivatives) and are beneficial for bacterial cells not only as osmoregulatory solutes, but also as protectants of proteins by mitigating detrimental effects of freezing, drying and high temperatures. The aspartate derivative ectoine is a wide spread compatible solute in Bacteria and possesses additional protective properties compared with other compatible solutes, and stabilizes even whole cells against stresses such as UV radiation or cytotoxins. The protective properties of ectoine for proteins can be explained by its strong (kosmotropic) interaction with water and subsequent exclusion from Protein surface, the decrease of the solubility of the peptide backbone and the strengthening of intramolecular hydrogen bonds (secondary structures). The stabilizing and UV-protective properties of ectoine attracted industry, which saw the potential to market ectoine as a novel active component in health care products and cosmetics. In joint efforts of industry and research large-scale fermentation procedures have been developed with the halophilic bacterium Halomonas elongata used as a producer strain. The two key technologies that allow for the annual production of ectoine on a scale of tons are the bacterial milking procedure and the development and application of ectoine-excreting mutants (“leaky” mutant). The details of these two procedures including the strain development and Fermentation processes will be introduced and current and future applications of ectoine will be discussed.
This survey will discuss current and emerging isothermal and rapid polymerase chain reaction (PCR) based nucleic acid amplification methods for patient near diagnostics. To assess the clinical need of rapid diagnostics for infectious diseases based on nucleic acid tests (NATs) we performed and analysed a questionnaire among laboratories participating in corresponding INSTAND ring trials for external quality assurance. The questions concerning new amplification technologies like isothermal nucleic acid amplification, potentially suited to significantly decrease turnaround times, were complemented by questions to evaluate the present status of NATs. Besides end-users, companies were also addressed by sending out a manufacturer specific questionnaire. Analysis of the answers from 48 laboratories in 14 European countries revealed that a much shorter turnaround time is requested for selected pathogens compared to about 2 h or longer when applying temperature cycling amplification, i.e. PCR. In this context, most frequently mentioned were MRSA, norovirus, influenza A and B viruses, cytomegalovirus (CMV) as well as hepatitis B virus (HBV) and hepatitis C virus (HCV). At present, 8% of the laboratories having participated in this survey apply isothermal amplification of nucleic acid to identify infectious pathogens.
Starch is one of the most common and easily obtained natural polymers, making it attractive as a potential bio-based alternative to synthetic polymers. This study shows that a simple quaternary ammonium salt combined with urea or glycols forms effective modifiers that produce flexible plastics with good mechanical properties that are comparable to some polyolefin plastics. The processing conditions are shown to significantly affect the structure of the polymer which has a concomitant effect upon the mechanical and physical properties of the resulting plastic. Using a glycerol based modifier results in a totally sustainable and biodegradable material which can be injection moulded.
Die Ortung von schlaffer Bewehrung in Beton erfolgt routinemäßig mit bildgebenden Radar- oder Wirbelstromverfahren. Die Anwendung dieser Verfahren ist aber begrenzt, wenn es sich um die Ortung tiefliegender Bewehrung (ab ca. 30 cm) oder um jungen Beton handelt. Grund ist die Schwächung der Radarpulse durch oberflächennahe Bewehrung oder durch die Betonfeuchte. Das bildgebende Ultraschallechoverfahren bietet den Vorteil, dass die Ultraschallpulse in diesen Fällen eine wesentlich höhere Eindringtiefe erreichen.
Im vorliegenden Beitrag wird eine Fallstudie vorgestellt, bei der mehrlagig eingebrachte Bewehrungseisen in einer nur einseitig zugänglichen 60 cm dicken Betonplatte geortet werden sollten, um eine Kernbohrung ohne Verkanten der Bohrkrone durchzuführen.
Zur Ortung der Bewehrung wurde das Ultraschallechoverfahren mitScherwellen der Mittenfrequenz 50 kHz mit einem automatisch arbeitenden Bauwerksscanner eingesetzt. Aus den flächig aufgenommenen Messdaten wurde mit der Rekonstruktionsrechnung nach dem Prinzip der synthetischen Apertur (SAFT, Synthetic Aperture Focusing Technique) die Position der Bewehrungseisen bildhaft ortsgenau dargestellt. Dies gelingt mit einer Auswertungsoption, bei der die Phase der reflektierten Ultraschallpulse ermittelt und farbcodiert dargestellt wird (Phasenauswertung). Damit lassen sich Reflexionen der Bewehrung eindeutig von eventuellen Fehlstellen oder Rückwandechos unterscheiden.
Klebverbindungen im modernen Hochbau können helfen, innovative ästhetische Bedürfnisse im Fassadenbau umzusetzen, technologische Verbesserungen zu erreichen, aber auch die Wechselwirkung von Gebäuden mit der Umwelt unter energetischen Aspekten zu optimieren. Aufgrund der hohen sicherheitstechnischen Bedeutung gibt es hohe Anforderungen an die Leistungsfähigkeit, Dauerhaftigkeit und die Gütesicherheit.
Mit einer zerstörungsfreien praxistauglichen Prüftechnik, die eine sichere Überprüfung der Integrität von Glas-Metall Klebverbindungen im Ingenieurhochbau gewährleistet, kann sowohl ein wichtiger Beitrag zur Qualitätssicherung bei der Herstellung von Fassadenelementen aber auch bei der späteren Bauwerksüberwachung im Verlauf der Nutzungsdauer geleistet werden. Für eine Beurteilung der Qualität der Verbundfuge (z.B. bezgl. Standsicherheit) sind dabei Aussagen zur Homogenität der Verbundfuge, zum adhäsiven und kohäsiven Verbundverhalten gefordert. Hierzu besteht aktuell insbesondere Bedarf an zerstörungsfreien praxisgerechten, hoch ortsauflösenden und möglichst bildgebenden Untersuchungsverfahren.
Es wird mit einem Matrixarray und mit konventionellen Winkelprüfköpfen eine Prüftechnik vorgestellt, mit der die Wechselwirkung zwischen Ultraschallwelle und Fehlstelle in der Klebefuge untersucht wird. Hierbei ist das erste Untersuchungsziel, mit einer angepassten Ultraschall-Prüftechnik mögliche Inhomogenitäten oder Schädigungsstellen in der geklebten Glas-Metall Verbindung zu detektieren.
Über diese qualitativen Aussagen hinaus werden weiterführende Informationen über die flächenhafte Ausdehnung und den Ort einer mangelnden Klebung ermittelt. Dazu werden die Messwerte zusammen mit den Positionen des Ultraschallprüfkopfs aufgezeichnet. Mit Hilfe einer bildhaften Auswertung der gemessenen Ultraschallechos in Abhängigkeit vom Prüfkopfort werden die Möglichkeiten einer detaillierten Integritätsanalyse der Glas-Metall Klebschicht dargestellt. In diesem Beitrag werden experimentelle Prüfergebnisse vorgestellt, die im Sinne einer Verfahrensvalidierung an einem speziellen Beispielprobekörper zur Nachstellung einer SSG-Verglasung (ermittelt wurden und die Detektion fehlerhafter Klebestellen in einer Glas-Metall-Klebverbindung zum Ziel haben.
The objective of the report is to present the state-of-the art of non-destructive testing methods and technologies for the inspection of thick, heavily-reinforced structures, (e.g. found in nuclear power plants). Wall thicknesses can be in excess of one meter and the structures often have increased steel reinforcement density. The accessibility for any testing method may be limited due to the presence of liners and other components such as cast-in-place items. Testing methods have to provide solutions for tasks such as locating failure (inclusions, corrosion, voids, delaminations) in the structures or the assessment of the condition of the structure in general.
Measurement of spontaneous magnetic stray field signals has been reported to be a promising tool for capturing macro-scale information of deformation states, defects and stress concentration zones in a material structure. This paper offers a new method for self-magnetic leakage field detection using a magneto-optical (MO) hand-held microscope. Its sensor has a dynamic field range between ±0.05 and ±2 kA/m and a lateral optical resolution of approx. 10 µm. We examined flat tensile test specimens of metastable austenitic steel AISI 304. Static tensile tests were repeatedly interrupted at various predetermined states of strain and the magnetic information was measured by the MO system. Comparative measurements using a high-precision magnetic field GMR-sensor, verify the outstanding capability of the MO microscope regarding spatial resolution of magnetic fields.
Ergopeptides, like ergocornine and a-ergocryptine, exist in an S- and in an R-configuration. Kinetic experiments imply that certain configurations are preferred depending on the solvent. The experimental methods are explained in this article. Furthermore, computational methods are used to understand this configurational preference. Standard quantum chemical methods can predict the favored configurations by using minimum energy calculations on the potential energy landscape. However, the explicit role of the solvent is not revealed by this type of methods. In order to better understand its influence, classical mechanical molecular simulations are applied. It appears from our research that 'folding' the ergopeptide molecules into an intermediate state (between the S- and the R-configuration) is mechanically hindered for the preferred configurations.