Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2014 (4) (entfernen)
Dokumenttyp
Sprache
- Englisch (4)
Referierte Publikation
- ja (4)
Schlagworte
- Digital detector array (DDA) (3)
- Betatron (2)
- NDT (2)
- Radiography (2)
- X-ray backscatter imaging (2)
- Aerospace applications (1)
- Casting (1)
- Comparison of detectors (1)
- Container inspection (1)
- Detection of dangerous materials (1)
A comparative study on the performance of digital detector systems for high energy applications
(2014)
For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements.
Innovative X-ray backscatter technique for security applications: Detection of dangerous materials
(2014)
Radiological inspections, in general, are NDT&E methods to detect the bulk of explosives without invasion into the object of analysis. In contrast to personal luggage, cargo or structural components constitute a complexity that may significantly hamper the detection of a threat by conventional transmission radiography. A novel approach of interrogating a large object to a certain depth only with a single sided access will be presented. It consists of an X-ray backscatter camera with a special twisted slit collimator for imaging backscattered objects. The new X-ray backscatter camera is not only imaging the objects due to their densities but also by taking into account the influences of surrounding objects. Additionally, it does not only image illuminated features but also depicts shadows from absorbing materials. This is a unique characteristic of the developed X-ray backscatter camera. Experimental mock-ups are conducted imitating container with threats among a complex packing as they may be encountered in reality. At the end, the significant advantages of the presented X-ray backscatter camera in the context of aviation and port security will be discussed.
In this contribution, we present a dual high-energy X-ray imaging technique for cargo container inspection using the 'spectral high-energy X-ray attenuation method'. This method is based on attenuation of continuous highenergy spectra. The developed experimental technique consists of a betatron as high-energy (up to 7.5 MeV) X-ray source and a matrix detector with high spatial resolution (400 ìm) for digital X-ray imaging. In order to evaluate the material discrimination capability using dual high-energy X-ray imaging, a test specimen is proposed, comprising step wedges of different low and high atomic number (Z) materials. The selected X-ray spectra for the dual-energy experiments correspond to 3 MV and 7.5 MV acceleration potential of the betatron. We evaluated the ratio between low- and high-energy X-ray attenuation coefficients quantitatively based on simulated poly-energetic high-energy X-ray source spectra and the detector sensitivity using the 'analytical Radiographic Testing inspection simulation tool' (aRTist) developed at BAM. The simulated effective attenuation coefficients are compared with corresponding experimental results in order to establish a method for identification of low- and high-Z materials in the container. Finally, important applications of the proposed technique in the context of aviation security are discussed.
Critical parts in aircraft manufacturing such as stringers are very commonly used in modern aircraft structures to resist the compressive loads caused by the aerodynamic effects. They are generally made-up of thin aluminium (Al) metal sheets and are one of the key components in the aircraft wings. Any defects in the stringer leads to weakening of the stiffness of the whole wing structure and consequently, failures may occur. Hence, the structural integrity of the stringers should be evaluated using reliable non-destructive testing (NDT) methods. Due to the complex shaped structure of the stringer, the one-sided access NDT method such as X-ray backscatter technique is more preferable for the non-destructive imaging. In this paper, we present a new X-ray backscatter technique to image the internal sections of the stringer with only a single-sided access. The whole object was inspected by changing the viewing direction of the X-ray backscatter camera. For the first time, the X-ray backscatter measurements were conducted using high-energy (> 0.5MeV) X-rays and proved the applicability of the present technique to inspect thick carbon-fiber laminated components. In order to improve the inspection time and image quality of the backscatter image, we used high-resolution (180ìm) digital detector arrays (DDAs). At the end, important applications of the presented X-ray backscatter technique to the aerospace industry are discussed.