Combustion of peroxy-fuels
(2011)
The diffusion flames of organic peroxides exhibit quite different characteristics than hydrocarbons. What makes them interesting to study is their fast burning behaviour. As a result the flame temperature enhances and so does the thermal radiation. Due to all these they demand safe handling during processing. However, they can be utilised at several places in different industries where a fuel with fast burning, high temperature and intense radiation are desired. Some of the possibilities to use them as a main or supporting fuel in a wide range of industrial utilities are the major content of this paper.
The use of energetic materials as a main fuel in high temperature process
industries are not known to the scientific community as such. This paper
highlights some of the features and advantages of using organic peroxides
especially di-tert-butyl peroxide (DTBP) in high temperature process industries.
The feasibility of using DTBP as a main or supporting fuel in process industries
have also been justified with the help of Computational Fluid Dynamics (CFD)
simulations. For peroxides requirement of less fuel and air for the same amount
of heat flux has been shown. The resulted emission from the combustion of
DTBP is also discussed.
Die ZfP versucht mit Hilfe von Messdaten, die sie aus z. B. einer Impuls-Echo-Messung gewinnt, Rückschlüsse auf die innere Struktur eines Objektes zu ziehen. Bei Betonbauteilen sollen im Besonderen Verpressfehler, die dann zur Korrosion und damit zur einer Beeinträchtigung der Standsicherheit und Dauerhaftigkeit des Konstruktion (z. B. einer Spannbetonbrücke) führen können, schnell und mit einer hohen Sicherheit aus den Messdaten lokalisiert werden. Das konventionellen SAFT oder FT-SAFT-Verfahren liefern in Verbindung mit einer Phasenauswertung einen schnellen und sicheren Hinweis darauf, dass ein Lufteinschluss/Defekt vorliegt. Darüber hinaus können jedoch Rückausbreitungs-Verfahren, wenn ein gutes Geschwindigkeitsprofil vorliegt, eine wesentlich bessere Lokalisierung des Defekts bieten als SAFT-Verfahren, jedoch mit dem Nachteil, dass sie sehr zeit- und rechenintensiv sind, vor allem im Dreidimensionalen. Als Mittelweg kann hierzu die "One-Way"-Methode dienen. Diese Methode verwendet Pseudo-Differential-Operatoren und ist sehr robust auch bei relativ groben Geschwindigkeitsprofilen. Sie wird an Beispielen aus der Bauwerkdiagnose mit den konventionellen Verfahren verglichen.
Analyzing damages at concrete structures due to physical, chemical, and mechanical exposures need the application of innovative non-destructive testing methods that are able to trace spatial changes of microstructures. Here, the utility of three different crack detection methods for the analysis of computed tomograms of various cementitious building materials is evaluated. Due to the lack of reference samples and standardized image quality evaluation procedures, the results are compared with manually segmented reference data sets. A specific question is how automatic crack detection can be used for the quantitative characterization of damage processes, such as crack length and volume. The crack detection methods have been integrated into a scientific visualization system that allows displaying the tomography images as well as presenting the results.
Tomography data obtained from transmission electron microscopes are especially attractive due to their unrivaled spatial resolution in the nanometer range or even less, but they require enormous efforts in sample preparation and suffer from a diverse accumulation of experimental restrictions, which unavoidably result in fundamental reconstruction artifacts. These restrictions refer to: partial opacity, a limited view (limited angle or missing wedge), very few angles (with respect to the detector size), limited to a region of interest (ROI; due to the sample size), variable angular increments as well as sample degradation due the interactions with the electron beam. An advanced version of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm proves to cope with most of these severe deviations from ideal CT measuring conditions. However, careful data preprocessing is required in order to exploit the capabilities of the algorithm.
Nanometer sized Ruthenium catalyst particles for fuel cell applications are 3D imaged at a few Ångström resolution in order to estimate their partial free surface on carbon black supports, which rule the efficiency of the catalytic activity.
Comparisons of DIRECTT reconstructions to the conventional filtered back projection, prove the significant improvements.
A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background Signals (backlight) of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beers law in single projections (radiographs).
When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation Phase and the samples aspect ratio (dynamics). The magnitude of the diffuse Background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shaded area and the stronger the total attenuation.
Moreover, the local intensity mismatch depends on the attenuation of the sample.
We present very basic reference data measured with multiple metal foils at a synchrotron radiation source. Beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure assumes a constant (non-local) scattering mechanism.
Die POD (Probability of Detection) hat sich als statistisches Werkzeug für die Bewertung der Zuverlässigkeit zerstörungsfreier Prüfsysteme in der klassischen ZfP bewährt. Aus diesem Grund wird die Methode der POD auf die zerstörungsfreie Prüfung im Bauwesen übertragen, um erstmals eine objektive Antwort auf zerstörungsfreie Prüfungen geben zu können, denen eine qualitative Fragestellung zugrunde liegt. Dies geschieht an der Prüfaufgabe der Ortung metallischer Reflektoren in Abhängigkeit Ihrer Tiefenlage mithilfe des Impulsradars. Dazu wird nachgewiesen, dass eine Übertragung und Anwendung der POD für die objektive Bewertung dieser Prüfaufgabe zulässig ist. Nach der Konzipierung und Fertigung von Testkörpern werden die Ergebnisse der POD(a)-Analyse vorgestellt, die erstmal eine Charakterisierung und einen Vergleich unterschiedlicher Radarprüfsysteme anhand eines objektiv ermittelten Kennwerts ermöglichen. Außerdem können Einflussgrößen auf die Detektionstiefe eines metallischen Reflektors erstmals quantifiziert werden.
Die Computertomographie (CT) hat sich als dimensionelle Messmethode in der industriellen Produktion etabliert. Durch Messungen an speziellen Prüfkörpern ist es möglich, quantitative Informationen über die metrologischen Eigenschaften dimensioneller Messungen zu erhalten. In dieser Arbeit wird einen Aluminium-Guss-Prüfkörper (120 mm x 90 mm x 60 mm) benutzt, mit dem – in der vorliegender Form – auch der Einfluss von Materialien unterschiedlicher Schwächung auf dimensionelle CT-Messungen untersucht werden kann. Der Prüfkörper ist in vier Segmente zerteilt, so dass auch innenliegende, raue Gussfreiformflächen der taktilen Koordinatenmessung zugänglich sind. Durch adaptierte Rubinkugeln als Referenzstrukturen können die CT-Messdaten in taktile Referenz-Koordinatensysteme überführt werden. Um den Einfluss von Materialien unterschiedlicher Schwächung auf das dimensionelle Messen mit CT zu untersuchen, wurden stärker schwächende ZTA-Störkugeln (Zirconia Toughened Alumina) mit zur Ausrichtung geeigneter Symmetriebrechung in der Nähe von ausgewählten taktilen Messstellen angebracht.
Zur Bewertung der Messabweichungen dienen taktile Referenzmessungen an den ZTA-Kugeln sowie taktile Messungen an den Freiformflächen des Gussteils, wobei durch ein iteratives Antastverfahren eine verbesserte Erfassung der Geometrie auch bei starken lokalen Oberflächenkrümmungen sichergestellt wird.
In dieser Arbeit werden geschweißte Platten aus dem Feinkornstahl P460NL1 untersucht. Korrosion und Ermüdungsrisswachstum werden als Schadensmechanismen in das Material eingebracht und auf ihre Nachweisbarkeit in Plattenversuchen geprüft. Die Schallemissionssignale wurden nach primären und sekundären Quellmechanismen getrennt und ihr Einfluss auf die Gesamtemission analysiert.
Hinsichtlich Materialermüdung und Betriebsfestigkeit in Faserkunststoffverbunden besteht - verglichen mit anderen Aspekten des Faserverbundleichtbaues – noch erheblicher Forschungsbedarf. Schon weit vor den globalen Festigkeiten des Laminates treten eine Vielzahl von Zwischenfaserbrüchen und vereinzelte Faserbrüche auf. Die Dichte dieser Mikrorisse soll hier als Indikator für den Zustand des Verbundes genutzt werden. Ihre Ermittlung stellt insbesondere bei Kohlenstofffasern eine Herausforderung dar. Über vergleichende Messungen mit der Schallemissionsanalyse (SEA) und der Röntgenrefraktionsscans (RR) wird die Entwicklung der Rissdichte bei Belastung untersucht. Die SEA zeichnet die Entstehung der Risse auf und kann wegen der kompakten Messtechnik auch gut am Bauteil eingesetzt werden. Die RR beobachtet die Änderung der inneren Grenzflächen, die ebenfalls die Entwicklung der Rissdichte widerspiegelt. Sie ist allerdings zurzeit nur als Laborverfahren geeignet. Der Vortrag berichtet(e) über den aktuellen Stand des vergleichenden Einsatzes beider Verfahren an Flachproben und innendruckbelasteten Rohrproben.