In this work, we present a novel approach to photothermal super resolution based thermographic resolution of internal defects using two-dimensional pixel pattern-based active photothermal laser heating in conjunction with subsequent numerical reconstruction to achieve a high-resolution reconstruction of internal defect structures. With the proposed adoption of pixelated patterns generated using laser coupled high-power DLP projector technology the complexity for achieving true two-dimensional super resolution can be dramatically reduced taking a crucial step forward towards widespread practical viability. Furthermore, based on the latest developments in high-power DLP projectors, we present their first application for structured pulsed thermographic inspection of macroscopic metal samples. In addition, a forward solution to the underlying inverse problem is proposed along with an appropriate heuristic to find the regularization parameters necessary for the numerical inversion in a laboratory setting. This allows the generation of synthetic measurement data, opening the door for the application of machine learning based methods for future improvements towards full automation of the method. Finally, the proposed method is experimentally validated and shown to outperform several established conventional thermographic testing techniques while conservatively improving the required measurement times by a factor of 8 compared to currently available photothermal super resolution techniques.
Learned block iterative shrinkage thresholding algorithm for photothermal super resolution imaging
(2022)
Block-sparse regularization is already well known in active thermal imaging and is used for multiple-measurement-based inverse problems. The main bottleneck of this method is the choice of regularization parameters which differs for each experiment. We show the benefits of using a learned block iterative shrinkage thresholding algorithm (LBISTA) that is able to learn the choice of regularization parameters, without the need to manually select them. In addition, LBISTA enables the determination of a suitable weight matrix to solve the underlying inverse problem. Therefore, in this paper we present LBISTA and compare it with state-of-the-art block iterative shrinkage thresholding using synthetically generated and experimental test data from active thermography for defect reconstruction. Our results show that the use of the learned block-sparse optimization approach provides smaller normalized mean square errors for a small fixed number of iterations. Thus, this allows us to improve the convergence speed and only needs a few iterations to generate accurate defect reconstruction in photothermal super-resolution imaging.
Thermographic photothermal super resolution reconstruction enables the resolution of internal defects/inhomogeneities below the classical limit, which is governed by the diffusion properties of thermal wave propagation. Based on a combination of the application of special sampling strategies and a subsequent numerical optimization step in post-processing, thermographic super resolution has already proven to be superior to standard thermographic methods in the detection of one-dimensional defect/inhomogeneity structures. In our work, we report an extension of the capabilities of the method for efficient detection and resolution of defect cross sections with fully two-dimensional structured laser-based heating. The reconstruction is carried out using one of two different algorithms that are proposed within this work. Both algorithms utilize the combination of several coherent measurements using convex optimization and exploit the sparse nature of defects/inhomogeneities as is typical for most nondestructive testing scenarios. Finally, the performance of each algorithm is rated on reconstruction quality and algorithmic complexity. The presented experimental approach is based on repeated spatially structured heating by a high power laser. As a result, a two-dimensional sparse defect/inhomogeneity map can be obtained. In addition, the obtained results are compared with those of conventional thermographic inspection methods that make use of homogeneous illumination. Due to the sparse nature of the reconstructed defect/inhomogeneity map, this comparison is performed qualitatively.
Reliability assessment of existing bridge constructions based on results of non-destructive testing
(2018)
The non-destructive testing methods available for civil engineering (NDT-CE) enable the measurements of quantitative parameters, which realistically describe the characteristics of existing buildings. In the past, methods for quality evaluation and concepts for validation expanded into NDT-CE to improve the objectivity of measured data. Thereby, a metrological foundation was developed to collect statistically sound and structurally relevant information about the inner construction of structures without destructive interventions. More recently, the demand for recalculations of structural safety was identified. This paper summarizes a basic research study on structural analyses of bridges in combination with NDT. The aim is to use measurement data of nondestructive testing methods as stochastic quantities in static calculations. Therefore, a methodical interface between the guide to the expression of uncertainty in measurement and probabilistic approximation procedures (e.g. FORM) has been proven to be suitable. The motivation is to relate the scientific approach of the structural analysis with real information coming from existing structures and not with those found in the literature. A case study about the probabilistic bending proof of a reinforced concrete bridge with statistically verified data from ultrasonic measurements shows that the measuring results fulfil the requirements concerning precision, trueness, objectivity and reliability.
Systematic errors in the evaluation of uncorrected data from thermographic lock-in measurements
(2018)
Lock-in thermography (LT) is based on the correct evaluation of phase differences between the temperature oscillations at different surface regions of the object under test during periodic heating. Since the usual heating procedures contain a DC component, the actual heating pattern achieved is not harmonic. This causes systematic deviations when phase differences are determined by means of harmonic analysis, e.g. with FFT analysis. The resulting errors depend clearly on the ratio between DC and AC amplitude, which is demonstrated at simulated and experimentally recorded temperature transients. Further experimental LT data obtained by different oscillating energy inputs showed a variety of possible shapes of transients with different DC components.
Measurement of spontaneous magnetic stray field signals has been reported to be a promising tool for capturing macro-scale information of deformation states, defects and stress concentration zones in a material structure. This paper offers a new method for self-magnetic leakage field detection using a magneto-optical (MO) hand-held microscope. Its sensor has a dynamic field range between ±0.05 and ±2 kA/m and a lateral optical resolution of approx. 10 µm. We examined flat tensile test specimens of metastable austenitic steel AISI 304. Static tensile tests were repeatedly interrupted at various predetermined states of strain and the magnetic information was measured by the MO system. Comparative measurements using a high-precision magnetic field GMR-sensor, verify the outstanding capability of the MO microscope regarding spatial resolution of magnetic fields.
The digital photography has almost completely substituted the film photography. The film replacement is also fast progressing in medical X-ray radiography. This process is slower in NDT and especially in Europe. Reasons for the hesitating change to digital radiography (RT-D) in NDT are the necessary time for adoption of standards and the conservative request for film RT by auditors and NDT managers for applications in large plants and at construction areas. The fast serial inspection for small castings is already almost completely dominated by RT-D due to the cost effective short exposure and interpretation times. Standards were developed in parallel at CEN, ISO, ASTM and ASME. Unfortunately, the standard practices are different and the requirements on image quality and useable hardware are different too. The first standard series on Computed Radiography were developed and published by CEN and ASTM in 2005. Harmonized classification and qualification standards are available but the published practices are different. ASTM has developed the first standards for application of Digital Detector Arrays (DDA) in 2010. The first digital RT ISO standard practice is ISO 17636-2 (2013), which describes the practice for application of DDAs and Imaging Plates for weld inspection. At the first time this standard provides requirements for the selection of suitable hardware. Minimum image quality requirements are specified in analogy to film radiography and 3 Compensation Principles are defined to enable the application of a wider range of digital detectors. A comparison of the different international digital RT standards is given and first experiences with ISO 17636-2 are discussed. New standards on RT wall thickness and corrosion measurements (EN 16407, film and digital) have been developed recently.
In this contribution, we present a dual high-energy X-ray imaging technique for cargo container inspection using the 'spectral high-energy X-ray attenuation method'. This method is based on attenuation of continuous highenergy spectra. The developed experimental technique consists of a betatron as high-energy (up to 7.5 MeV) X-ray source and a matrix detector with high spatial resolution (400 ìm) for digital X-ray imaging. In order to evaluate the material discrimination capability using dual high-energy X-ray imaging, a test specimen is proposed, comprising step wedges of different low and high atomic number (Z) materials. The selected X-ray spectra for the dual-energy experiments correspond to 3 MV and 7.5 MV acceleration potential of the betatron. We evaluated the ratio between low- and high-energy X-ray attenuation coefficients quantitatively based on simulated poly-energetic high-energy X-ray source spectra and the detector sensitivity using the 'analytical Radiographic Testing inspection simulation tool' (aRTist) developed at BAM. The simulated effective attenuation coefficients are compared with corresponding experimental results in order to establish a method for identification of low- and high-Z materials in the container. Finally, important applications of the proposed technique in the context of aviation security are discussed.
Critical parts in aircraft manufacturing such as stringers are very commonly used in modern aircraft structures to resist the compressive loads caused by the aerodynamic effects. They are generally made-up of thin aluminium (Al) metal sheets and are one of the key components in the aircraft wings. Any defects in the stringer leads to weakening of the stiffness of the whole wing structure and consequently, failures may occur. Hence, the structural integrity of the stringers should be evaluated using reliable non-destructive testing (NDT) methods. Due to the complex shaped structure of the stringer, the one-sided access NDT method such as X-ray backscatter technique is more preferable for the non-destructive imaging. In this paper, we present a new X-ray backscatter technique to image the internal sections of the stringer with only a single-sided access. The whole object was inspected by changing the viewing direction of the X-ray backscatter camera. For the first time, the X-ray backscatter measurements were conducted using high-energy (> 0.5MeV) X-rays and proved the applicability of the present technique to inspect thick carbon-fiber laminated components. In order to improve the inspection time and image quality of the backscatter image, we used high-resolution (180ìm) digital detector arrays (DDAs). At the end, important applications of the presented X-ray backscatter technique to the aerospace industry are discussed.