Wissenschaftliche Artikel der BAM
Filtern
Dokumenttyp
Referierte Publikation
- nein (5) (entfernen)
Schlagworte
- Simulation (5) (entfernen)
Organisationseinheit der BAM
The lack of traceability to meter of X-ray Computed Tomography (CT) measurements still hinders a more extensive acceptance of CT in coordinate metrology and industry. To ensure traceable, reliable, and accurate measurements, the determination of the task-specific measurement uncertainty is necessary. The German guideline VDI/VDE 2630 part 2.1 describes a procedure to determine the measurement uncertainty for CT experimentally by conducting several repeated measurements with a calibrated test specimen. However, this experimental procedure is cost and effort intensive. Therefore, the simulation of dimensional measurement tasks conducted with X-ray computed tomography can close these drawbacks. Additionally, recent developments towards a resource and cost-efficient production (“smart factory”) motivate the need for a corresponding numerical model of a CT system (“digital twin”) as well. As there is no standardized procedure to determine the measurement uncertainty of a CT system by simulation at the moment, the project series CTSimU was initiated, aiming at this gap. Concretely, the goal is the development of a procedure to determine the measurement uncertainty numerically by radiographic simulation. The first project (2019-2022), "Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU" developed a framework to qualify a radiographic simulation software concerning the correct simulation of physical laws and functionalities. The most important outcome was a draft for a new guideline VDI/VDE 2630 part 2.2, which is currently under discussion in the VDI/VDE committee. The follow-up project CTSimU2 "Realistic Simulation of real CT systems with a basic-qualified Simulation Software" will deal with building and characterizing a digital replica of a specific real-world CT system. The two main targets of this project will be a toolbox including methods and procedures to configure a realistic CT system simulation and to develop tests to check if this replica is sufficient enough. The result will be a draft for a follow-up VDI/VDE guideline proposing standardized procedures to determine a CT system's corresponding characteristics and test the simulation (copy) of a real-world CT system which we call a "digital twin".
Radiografische Simulationswerkzeuge wie aRTist, ScorpiusXLab, SimCT oder CIVA CT verwenden analytische Methoden und physikalische Monte-Carlo-Teilchentransportsimulationen, um die Interaktionsprozesse zwischen Röntgenstrahlung und Materie zu simulieren. Die berechneten Projektionen bilden anschließend unter Berücksichtigung einer definierten Scan-Trajektorie die Basis der Simulation einer röntgencomputertomografischen Untersuchung.
Für den erfolgreichen Einsatz der Computertomografie, sei es als zerstörungsfreie Prüfmethode oder beim dimensionellen Messen, ist es generell notwendig, bekannte Fehler- bzw. Abweichungsquellen des Messverfahrens auszuschließen oder zu reduzieren. Dabei hat sich gezeigt, dass die Auswahl der Messparameter und die Erfahrung des Anwenders direkten Einfluss auf das erzielbare Messergebnis einer computertomografischen Untersuchung nehmen. Es ist daher sinnvoll, die Parameterauswahl in einem virtuellen Simulationsaufbau vorher zu erproben und an die Messaufgabe anzupassen.
Neben der Optimierung von Messparametern finden radiografische Simulationswerkzeuge auch Anwendung für Machbarkeitsstudien und werden zur Schulung von Anwendern im Bereich der Röntgen-Computertomografie verwendet.
Radiografische Simulationswerkzeuge befinden sich in einem stetigen Wandel, beispielsweise durch die Entwicklung neuer Rekonstruktionsmethoden, durch Erweiterung von analytischen Modellen, durch Integration komplexer Trajektorien oder durch Berücksichtigung von prozessbedingten geometrischen Abweichungen. Im laufenden EMPIR-Projekt „AdvanCT“ entsteht deshalb ein „Good Practice Guide“ für die Simulationsumgebung aRTist. Ziel dieses Guides ist es, die mit steigender Komplexität verbundenen Einstiegshürden für Anwender von aRTist zu reduzieren, um damit einen praxisnahen Zugang zur virtuellen Computertomografie zu ermöglichen. Dabei werden anhand von praktisch nachvollziehbaren Beispielen die grundlegenden Mechanismen der Simulationsumgebung erklärt und ein strukturierter Leitfaden zur Simulation röntgencomputertomografischer Untersuchungen mit aRTist vermittelt.
In diesem Beitrag werden erste Auszüge des Guides sowie eine Übersicht der weiteren geplanten Themen für die anschließende Diskussion vorgestellt.
One essential step on the way towards accurate quantitative simulation of radiographic testing is an accurate description of the utilized energy spectrum of X-ray photons. For use in general purpose simulation tools, the spectra of X-ray tubes have to be described by a model covering at least the intended range of applications. This range includes transmission tubes as well as direct beam tubes with varying angles of incidence and emission, for a number of typical target materials. In radiographic testing acceleration voltages frequently reach up to 450 kV for direct beam targets and up to 225 kV for transmission targets, with even higher voltages available or being developed. Currently used models are unable to cover the whole range of configurations.
Here a model is presented that employs a unified approach for simulating the photon energy spectra for transmission and direct beam targets composed of arbi-trary homogeneous materials. In order to achieve this, a detailed model of electron transport within the target is employed. The validity of the developed model is shown through comparisons with Monte Carlo simulations as well as measurements for a number of different configurations.
X-ray backscatter imaging is a well established NDT technique to inspect complex objects using only a single-sided access. In difference to conventional transmission X-ray radiography, the X-ray backscatter imaging utilizes the scattered radiation caused by the Compton scattering effect. In order to achieve high backscatter intensities from a test object, it is necessary to optimize the backscatter system parameters namely the angle between source and slit camera, the slit collimator system, the shielding between source and scatter camera, and the type of detector. In addition, the scatter phenomena in to the investigated object need to be understood.
In this contribution, we present a Monte Carlo model McRay which considers all relevant single and multiple interactions of photons and electrons. This model can be used to simulate back scatter techniques. It allows not only calculating the scatter image for a given experimental setup but also registering the spectrum of the detected scattered photons. Both aspects are important to understand the imaging process, to interpret the results, and to optimize the backscatter camera investigated here. Additionally experimental results will be presented and compared with simulations.
Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. To describe the complete chain of RT, the model includes simulating all necessary properties of X- or Gamma-ray sources, the interaction of photons with material with special attention to scattered radiation, the detection process, and the complete geometrical RT setup handling arbitrary parts or constructions. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation, an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport such that transmission as well as scatter techniques can be modelled. In this contribution we Focus on Monte Carlo Simulation of scatter contribution within aRTist. Examples for RT/tomographic applications and back-scatter techniques are presented to demonstrate the usability of the presented simulation tool for a broad range of radiological applications.