Most knowledge about the structure, function, and evolution of early compound eyes is based on investigations in trilobites. However, these studies dealt mainly with the cuticular lenses and little was known about internal anatomy. Only recently some data on crystalline cones and retinula cells were reported for a Cambrian trilobite species. Here, we describe internal eye structures of two other trilobite genera. The Ordovician Asaphus sp. reveals preserved crystalline cones situated underneath the cuticular lenses. The same is true for the Devonian species Archegonus (Waribole) warsteinensis, which in addition shows the fine structure of the rhabdom in the retinula cells. These results suggest that an apposition eye with a crystalline cone is ancestral for Trilobita. The overall similarity of trilobite eyes to those of myriapods, crustaceans, and hexapods corroborates views of a phylogenetic position of trilobites in the stem lineage of Mandibulata.
Most knowledge about the structure, function, and evolution of early compound eyes is based on investigations in trilobites. However, these studies dealt mainly with the cuticular lenses and little was known about internal anatomy. Only recently some data on crystalline cones and retinula cells were reported for a Cambrian trilobite species. Here, we describe internal eye structures of two other trilobite genera. The Ordovician Asaphus sp. reveals preserved crystalline cones situated underneath the cuticular lenses. The same is true for the Devonian species Archegonus (Waribole) warsteinensis, which in addition shows the fine structure of the rhabdom in the retinula cells. These results suggest that an apposition eye with a crystalline cone is ancestral for Trilobita. The overall similarity of trilobite eyes to those of myriapods, crustaceans, and hexapods corroborates views of a phylogenetic position of trilobites in the stem lineage of Mandibulata.
Bikontinuierliche poröse Keramiken für Filteranwendungen weisen eine komplizierte Mikrostruktur auf, in der Poren und Festkörperphase 'vermischt' sind. Mechanische, thermische sowie Filtereigenschaften können nur präzise bestimmt werden, wenn die Morphologie beider Phasen quantitativ angegeben werden kann. Hier werden unter Anwendung von 3D Computertomographie (CT) und verschiedenen Techniken, die auf der Röntgenrefraktion basieren, die Porosität und die Porenorientierung in keramischen Cordierit-Dieselpartikelfiltern bewertet. Dabei werden zur Auswertung der Tomogramme die Fouriertransformierten sowie eine neu entwickelte richtungssensitive Bildanalyse (DIVA, directional interface variance analysis) angewandt. Sowohl die genannten Messtechniken als auch der statistische Ansatz gestatten die Extraktion optional ortsaufgelöster oder gemittelter Werte. Es ergeben sich sehr gute Übereinstimmungen der experimentell ermittelten Porositätswerte mit Ergebnissen aus Quecksilberintrusionsversuchen als auch der ermittelten Porenorientierung im Vergleich zu publizierten Angaben zur kristallographischen Textur. Dies legt den Schluss nahe, dass die Kenntnis der Grenzflächen (zwischen Poren und Materie) genügt, die morphologischen Eigenschaften solcher Materialien hinreichend zu beschreiben.
Industrial computed tomography (CT) today is an important method to analyze defects and to measure the geometry of technical products. The measurement capability of industrial CT often depends on the knowledge of the measurement errors being present. Only with this knowledge, effective corrections are possible by manufacturers, or adapted measurement procedures become possible for the customers. Thus, there is the strong need to have adequate reference standards both for the assessment of general dependencies and for the measurement of task-specific effects. Especially the latter are difficult to assess. This paper shows the application of a versatile dismountable workpiece-near reference body for the use with CT. The reference standard was made from a miniaturized cast aluminium (one-)cylinder head. It can be dismounted into four segments, each featuring reference geometries which enable a registration of CT measured and other reference datasets (e.g. from tactile CMM). The reference standard embodies complex freeform surfaces which are a challenging measurement task for CT and other sensors. Here the application of the reference standard is the study of the influence of material mixes. This is realized by adding pieces of other materials which disturb the mono-material measurement.
Results of the application of the reference standard are presented using data from industrial micro-CT systems and CMM reference data. A special emphasis is given on the workflow of the data processing and the data analysis.
Die Computertomographie (CT) hat sich als dimensionelle Messmethode in der industriellen Produktion etabliert. Durch Messungen an speziellen Prüfkörpern ist es möglich, quantitative Informationen über die metrologischen Eigenschaften dimensioneller Messungen zu erhalten. In dieser Arbeit wird einen Aluminium-Guss-Prüfkörper (120 mm x 90 mm x 60 mm) benutzt, mit dem – in der vorliegender Form – auch der Einfluss von Materialien unterschiedlicher Schwächung auf dimensionelle CT-Messungen untersucht werden kann. Der Prüfkörper ist in vier Segmente zerteilt, so dass auch innenliegende, raue Gussfreiformflächen der taktilen Koordinatenmessung zugänglich sind. Durch adaptierte Rubinkugeln als Referenzstrukturen können die CT-Messdaten in taktile Referenz-Koordinatensysteme überführt werden. Um den Einfluss von Materialien unterschiedlicher Schwächung auf das dimensionelle Messen mit CT zu untersuchen, wurden stärker schwächende ZTA-Störkugeln (Zirconia Toughened Alumina) mit zur Ausrichtung geeigneter Symmetriebrechung in der Nähe von ausgewählten taktilen Messstellen angebracht.
Zur Bewertung der Messabweichungen dienen taktile Referenzmessungen an den ZTA-Kugeln sowie taktile Messungen an den Freiformflächen des Gussteils, wobei durch ein iteratives Antastverfahren eine verbesserte Erfassung der Geometrie auch bei starken lokalen Oberflächenkrümmungen sichergestellt wird.