Fused filament fabrication (FFF) is a material extrusion-based technique often used in desktop 3D printers. Polymeric filaments are melted and are extruded through a heated nozzle to form a 3D object in layers. The extruder temperature is therefore a key parameter for a successful print job but also one of the main emission driving factors as harmful pollutants (e.g., ultrafine particles) are formed by thermal polymer degradation. The awareness of potential health risks has increased the number of emission studies in the past years. However, studies usually refer their calculated emission data to the printer set extruder temperature for comparison purposes. In this study, we used a thermocouple and an infrared camera to measure the actual extruder temperature and found significant temperature deviations to the displayed set temperature among printer models. Our result shows that printing the same filament feedstocks with three different printer models and with identical printer set temperature resulted in a variation in particle emission of around two orders of magnitude. A temperature adjustment has reduced the variation to approx. one order of magnitude. Thus, it is necessary to refer the measured emission data to the actual extruder temperature as it poses a more accurate comparison parameter for evaluation of the indoor air quality in user scenarios or for health risk assessments.
Quantification of impact damages in CFRP and GFRP structures with thermography and ultrasonics
(2018)
The extent of damage caused by impacts in fibre reinforced composites depends on the energy of the impacts, on the velocity and the shape of the impacting body, on the material and structure of the composite and on the geometry of the structure. Here, mainly the thickness of the component is essential. The non-destructive evaluation of these damages can be carried out using both ultrasound and active thermography methods. A comparison of the detection sensitivity of these methods for the different damages is carried out in this paper depending on the fibre composite material used (CFRP and GFRP), the thickness of the material and the impact energy. The NDT methods used after the damage are supplemented by thermographic measurements with high temporal resolution, which were already recorded during the impact.
Der Umfang der durch Impacts in Faserverbundmaterialien erzeugten Schäden ist abhängig von der Energie des Impacts, von der Zusammensetzung und dem Aufbau der Faserverbundwerkstoffe und von der Geometrie der Bauteile und hier im Wesentlichen von der Dicke des Bauteils. Der zerstörungsfreie Nachweis dieser Schädigungen kann sowohl mit Ultraschallverfahren als auch mit Verfahren der aktiven Thermografie erfolgen. Ein Vergleich der Nachweisempfindlichkeiten dieser Verfahren für die unterschiedlichen Schädigungen wird in diesem Beitrag in Abhängigkeit vom verwendeten Faserverbundwerkstoff (CFK und GFK), der Dicke des Materials und von der Impactenergie durchgeführt. Ergänzt werden die im Anschluss an die Schädigung eingesetzten ZfP-Verfahren mit zeitlich hochaufgelösten Thermografiemessungen, die bereits während des Impacts aufgenommen wurden.
Im EMRP-Projekt VITCEA werden komplementäre ZFP-Verfahren zur Prüfung von Faserverbundwerkstoffen weiterentwickelt und validiert. In diesem Beitrag werden Ergebnisse verschiedener Techniken der aktiven Thermografie und des Ultraschalls vorgestellt. Die Nachweisempfindlichkeiten bezüglich künstlicher und natürlicher Fehler mit unterschiedlichen lateralen Ausdehnungen und in verschiedenen Tiefen werden miteinander verglichen.
Amongst various other NDT methods, within the EMRP-project
‘VITCEA’ active thermography is validated for testing of CFRP and
GFRP structures constructed for energy application. In this
contribution, the optical and thermal properties of CFRP and GFRP
reference defect artefact (RDA) and natural defects artefact (NDA)
test specimens are characterized. Different excitation techniques
and techniques for data analysis are compared for optimizing the
number of detected defects.
Active thermography is well suited for the detection of delaminations and cracks in façade elements like plaster and tiles. Not only artificial heating but also solar heating can be used if the adjustment of the façade and the weather conditions are suitable. Optical methods like laser scanners, photogrammetric methods and crack tracking sensors are providing geometrical 3D data which can be used for a 3D mapping of thermograms and for providing data with higher geometrical resolution. Thus, by the combination and fusion of these data, a comprehensive mapping and monitoring of damages of façade systems is possible.
The permanently increasing number of wind turbines requires suited inspection and monitoring methods to ensure liability and security. Concerning the inspection of ro-tor blades, only manual inspections are state of the art. Thermographic Testing (TT) has the potential to detect typical failures and damages on rotor blades. The paper presents some results of onsite measurements carried out as “passive thermogra-phy”, i.e. without a defined heating procedure. Due the totally contactless meas-urement principle, TT can be applied to rotating blades as well as to resting blades. Both methods will be compared with respect to their possible realization.
Im Rahmen des INS-Projekts „Durchführung von Ringversuchen zur Normung und Standardisierung der aktiven Thermografie mit Blitzlichtanregung“ wurden Ringversuche durchgeführt, die die Zuverlässigkeit, Vergleichbarkeit und Effektivität der Blitzthermografie für unterschiedliche Prüfprobleme nachweisen sollten. Weiterhin sollten diese Untersuchungen als Methodenvalidierungsstudie die Richtigkeit und Präzision der Blitzthermografie nachweisen und Vergleichsinformationen unterschiedlicher Geräteausstattungen liefern. Im Normausschuss NA 062-08-27 AA „Visuelle und thermografische Prüfung“ des DIN werden die Ergebnisse die Erarbeitung eines Normentwurfs zur Blitzthermografie unterstützen. In diesem Beitrag werden die Ringversuche beschrieben und ausgewählte Ergebnisse präsentiert.
Aktive Thermografieverfahren werden immer häufiger zur zerstörungsfreien Prüfung von Faserverbundwerkstoffen eingesetzt, da diese völlig berührungslos arbeiten und sowohl zur Prüfung großflächiger Strukturen als auch von großen Stückzahlen kleinerer Komponenten in der Fertigung eingesetzt werden können. Dieser Beitrag beschäftigt sich mit Untersuchungen an typischen Defekten und Inhomogenitäten, die bereits während der Fertigung von CFK Bauteilen entstehen oder unbeabsichtigt mit eingebaut werden. Systematische Untersuchungen wurden mit Blitzthermografie in Reflexions- und Transmissionskonfiguration und mit Computertomographie (CT) durchgeführt. Die CT wurde dabei als Referenzverfahren genutzt, da dieses Verfahren auch kleinere Defekte mit relativ hoher Ortsauflösung und unabhängig von der Tiefe darstellen kann.
Für die optische Erwärmung von Prüfteiloberflächen sind Blitz- und Halogenlampen Stand der Technik. Der Vorteil dieser Wärmequellen liegt in ihren relativ geringen Anschaffungskosten bei gleichzeitig hohen Leistungsdichten am Prüfobjekt. Nachteilig ist bei den Halogenlampen die Limitierung der möglichen Modulationsffequenz auf ca. 1 Hz für die Anwendung dieser Quelle in der Lockin-Thermografie. Blitzlampen bieten für gewöhnlich nur eine feste Blitzdauer bei einer geringen Taktrate. Beide Anregungsquellen müssen in Reflexionsanordnung mit Filtern betrieben werden um die entstehende thermische Eigenstrahlung als Störquelle zu eliminieren. Wir stellen Untersuchungen an Hochleistungs-LEDs für den Einsatz in der aktiven Thermografie vor. Diese Lichtquellen werden durch die rasante Entwicklung der möglichen Leistungsdichten nun auch für die thermografische ZfP interessant. Sie zeigen ähnlich dem Laser eine schmale und auf den Werkstoff abstimmbare spektrale Verteilung der Strahlungsleistung bei moderaten Kosten. Die zugrunde liegende Elektrolumineszenz generiert kaum Wärmestrahlung und ermöglicht dadurch die Prüfung während des Erwärmungsvorganges ohne größeren Aufwand. Modulationsfrequenzen über 100 Hz mit thermischen Eindringtiefen < 1 mm sind möglich. Dadurch qualifizieren sich die LEDs zur Anwendung in der Lockin-Thermografie von Metallen und zur oberflächennahen Prüfung von Schichtsystemen. Durch die fast verzögerungsffeie Reaktion der LED auf das steuernde Signal sind nahezu beliebige zeitliche Anregungsformen möglich. Mit solch flexiblen Anregungsformen ließen sich bereits bei den photothermischen Verfahren erfolgreich höhere Tiefenreichweiten und -auflösungen gegenüber den klassischen Methoden der monofrequenten Lockin - und energiereichen Kurzimpuls-Anregung erzielen. Untersuchungen dieser Möglichkeiten im praktischen Einsatz der HochleistungsLEDs werden vorgestellt und mit herkömmlichen Lichtquellen verglichen.