Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2014 (46) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (46) (entfernen)
Sprache
- Englisch (46) (entfernen)
Schlagworte
- Digital detector array (DDA) (3)
- NDT (3)
- Betatron (2)
- DNA radiation damage (2)
- Graphene (2)
- Image quality (2)
- Radiography (2)
- Raman spectroscopy (2)
- Standards (2)
- X-ray backscatter imaging (2)
Industrial production of the cell protectant ectoine: protection mechanisms, processes, and products
(2014)
Bacteria, Archaea and Eukarya can adapt to Saline environments by accumulating compatible solutes in order to maintain an osmotic equilibrium. Compatible solutes are of diverse chemical structure (sugars, polyols, amino acid derivatives) and are beneficial for bacterial cells not only as osmoregulatory solutes, but also as protectants of proteins by mitigating detrimental effects of freezing, drying and high temperatures. The aspartate derivative ectoine is a wide spread compatible solute in Bacteria and possesses additional protective properties compared with other compatible solutes, and stabilizes even whole cells against stresses such as UV radiation or cytotoxins. The protective properties of ectoine for proteins can be explained by its strong (kosmotropic) interaction with water and subsequent exclusion from Protein surface, the decrease of the solubility of the peptide backbone and the strengthening of intramolecular hydrogen bonds (secondary structures). The stabilizing and UV-protective properties of ectoine attracted industry, which saw the potential to market ectoine as a novel active component in health care products and cosmetics. In joint efforts of industry and research large-scale fermentation procedures have been developed with the halophilic bacterium Halomonas elongata used as a producer strain. The two key technologies that allow for the annual production of ectoine on a scale of tons are the bacterial milking procedure and the development and application of ectoine-excreting mutants (“leaky” mutant). The details of these two procedures including the strain development and Fermentation processes will be introduced and current and future applications of ectoine will be discussed.
This survey will discuss current and emerging isothermal and rapid polymerase chain reaction (PCR) based nucleic acid amplification methods for patient near diagnostics. To assess the clinical need of rapid diagnostics for infectious diseases based on nucleic acid tests (NATs) we performed and analysed a questionnaire among laboratories participating in corresponding INSTAND ring trials for external quality assurance. The questions concerning new amplification technologies like isothermal nucleic acid amplification, potentially suited to significantly decrease turnaround times, were complemented by questions to evaluate the present status of NATs. Besides end-users, companies were also addressed by sending out a manufacturer specific questionnaire. Analysis of the answers from 48 laboratories in 14 European countries revealed that a much shorter turnaround time is requested for selected pathogens compared to about 2 h or longer when applying temperature cycling amplification, i.e. PCR. In this context, most frequently mentioned were MRSA, norovirus, influenza A and B viruses, cytomegalovirus (CMV) as well as hepatitis B virus (HBV) and hepatitis C virus (HCV). At present, 8% of the laboratories having participated in this survey apply isothermal amplification of nucleic acid to identify infectious pathogens.
Starch is one of the most common and easily obtained natural polymers, making it attractive as a potential bio-based alternative to synthetic polymers. This study shows that a simple quaternary ammonium salt combined with urea or glycols forms effective modifiers that produce flexible plastics with good mechanical properties that are comparable to some polyolefin plastics. The processing conditions are shown to significantly affect the structure of the polymer which has a concomitant effect upon the mechanical and physical properties of the resulting plastic. Using a glycerol based modifier results in a totally sustainable and biodegradable material which can be injection moulded.
The objective of the report is to present the state-of-the art of non-destructive testing methods and technologies for the inspection of thick, heavily-reinforced structures, (e.g. found in nuclear power plants). Wall thicknesses can be in excess of one meter and the structures often have increased steel reinforcement density. The accessibility for any testing method may be limited due to the presence of liners and other components such as cast-in-place items. Testing methods have to provide solutions for tasks such as locating failure (inclusions, corrosion, voids, delaminations) in the structures or the assessment of the condition of the structure in general.
Ergopeptides, like ergocornine and a-ergocryptine, exist in an S- and in an R-configuration. Kinetic experiments imply that certain configurations are preferred depending on the solvent. The experimental methods are explained in this article. Furthermore, computational methods are used to understand this configurational preference. Standard quantum chemical methods can predict the favored configurations by using minimum energy calculations on the potential energy landscape. However, the explicit role of the solvent is not revealed by this type of methods. In order to better understand its influence, classical mechanical molecular simulations are applied. It appears from our research that 'folding' the ergopeptide molecules into an intermediate state (between the S- and the R-configuration) is mechanically hindered for the preferred configurations.
Slicing - a new method for non destructive 3D elemental sensitive characterization of materials
(2014)
Recent advances in synchrotron sources and detector technology have led to substantial improvements in spatial resolution and detection limits for X-ray fluorescence analysis (XRF). However, the non-destructive three-dimensional elemental sensitive characterization of samples remains a challenge. We demonstrate the use of the so-called 'Color X-ray Camera' (CXC) for 3D measurements for the first time. The excitation of the sample is realized with a thin sheet-beam. The stepwise movement of the sample allows getting the elemental distribution for each layer with one measurement. These layers can be combined to a full 3D dataset for each element afterwards. Since the information is collected layer by layer, there is no need to apply reconstruction techniques, which quite often are the reason for artifacts in the results achieved by computed tomography (CT). The field of applications is wide, as the 3D elemental distribution of a material contains clues to processes inside the samples from a variety of origins. The technique is of special interest and well suited for biological specimens, because their light matrix minimizes restricting absorption effects. Measurement examples of a hornet and the teeth of a Sorex araneus are shown.
In this work an air-based sensor network for the localization of persons at extensive areas is presented. The developed network consists of a localization device which the person is wearing (BodyGuard-System), a mobile relay station in the air, and a base station. All three parts communicate with the same radio chip. The BodyGuard-System is an inertial navigation system which was developed for localization in difficult environments with high accuracy and low measurement uncertainty. To increase the range of the system, a multi-hop network was built up. The measured data of the BodyGuard-System and the mobile relay station is visualized on a PC in the base station. This multi-hop network is necessary for example for fire department missions.
Quantitative determination of acidic surface sites is highly important for the characterization of solid acids because the activity of a catalyst is often related to the concentration of these sites. A recently developed method using 15N Nuclear Magnetic Resonance spectroscopy (NMR) for the quantification of acidic Lewis and Brønsted sites has been tested for a series of nanoscopic aluminum hydroxide fluorides. Comparison with other methods for the quantitative determination of acidic sites shows that this 15N NMR quantification method is a promising technique for the comprehensive investigation of acidic sites. Three different acidic sites, one Brønsted and two Lewis sites, can be distinguished by their 15N chemical shifts of pyridine and simultaneously quantified under conditions corresponding to catalytic reaction conditions. Determination of the individual concentrations of acidic sites allows further insight into the catalytic process. It was found that the concentration of Brønsted sites correlates with catalyzed conversion of citronellal to isopulegol in the investigated series of catalysts. Additionally, investigations indicate that one of the Lewis sites become blocked during the reaction of citronellal.
The digital photography has almost completely substituted the film photography. The film replacement is also fast progressing in medical X-ray radiography. This process is slower in NDT and especially in Europe. Reasons for the hesitating change to digital radiography (RT-D) in NDT are the necessary time for adoption of standards and the conservative request for film RT by auditors and NDT managers for applications in large plants and at construction areas. The fast serial inspection for small castings is already almost completely dominated by RT-D due to the cost effective short exposure and interpretation times. Standards were developed in parallel at CEN, ISO, ASTM and ASME. Unfortunately, the standard practices are different and the requirements on image quality and useable hardware are different too. The first standard series on Computed Radiography were developed and published by CEN and ASTM in 2005. Harmonized classification and qualification standards are available but the published practices are different. ASTM has developed the first standards for application of Digital Detector Arrays (DDA) in 2010. The first digital RT ISO standard practice is ISO 17636-2 (2013), which describes the practice for application of DDAs and Imaging Plates for weld inspection. At the first time this standard provides requirements for the selection of suitable hardware. Minimum image quality requirements are specified in analogy to film radiography and 3 Compensation Principles are defined to enable the application of a wider range of digital detectors. A comparison of the different international digital RT standards is given and first experiences with ISO 17636-2 are discussed. New standards on RT wall thickness and corrosion measurements (EN 16407, film and digital) have been developed recently.
A comparative study on the performance of digital detector systems for high energy applications
(2014)
For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements.