Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (2083)
- Beitrag zu einem Tagungsband (386)
- Forschungsbericht (19)
- Beitrag zu einem Sammelband (10)
- Sonstiges (10)
- Buchkapitel (9)
- Corrigendum (3)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Dissertation (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (2287)
- Deutsch (233)
- Mehrsprachig (3)
- Portugiesisch (1)
Schlagworte
- Additive manufacturing (69)
- Fluorescence (56)
- Nanoparticles (48)
- Concrete (47)
- SAXS (46)
- Ultrasound (38)
- Corrosion (37)
- MALDI-TOF MS (36)
- Quantum yield (36)
- Non-destructive testing (34)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (448)
- 6 Materialchemie (442)
- 1 Analytische Chemie; Referenzmaterialien (362)
- 7 Bauwerkssicherheit (228)
- 5 Werkstofftechnik (218)
- 9 Komponentensicherheit (215)
- 4 Material und Umwelt (197)
- 6.3 Strukturanalytik (168)
- 8.5 Röntgenbildgebung (139)
- 6.1 Oberflächen- und Dünnschichtanalyse (102)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (101)
- 8.0 Abteilungsleitung und andere (100)
- 5.1 Mikrostruktur Design und Degradation (80)
- 9.3 Schweißtechnische Fertigungsverfahren (79)
- 1.2 Biophotonik (74)
- 6.6 Physik und chemische Analytik der Polymere (70)
- 9.4 Integrität von Schweißverbindungen (69)
- 8.4 Akustische und elektromagnetische Verfahren (66)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (64)
- 6.2 Material- und Oberflächentechnologien (63)
- 1.1 Anorganische Spurenanalytik (61)
- 7.4 Baustofftechnologie (61)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (57)
- 1.4 Prozessanalytik (56)
- 4.1 Biologische Materialschädigung und Referenzorganismen (56)
- 1.7 Organische Spuren- und Lebensmittelanalytik (55)
- 3 Gefahrgutumschließungen; Energiespeicher (54)
- 1.5 Proteinanalytik (52)
- 6.0 Abteilungsleitung und andere (51)
- 8.6 Faseroptische Sensorik (50)
- 1.8 Umweltanalytik (43)
- 4.3 Schadstofftransfer und Umwelttechnologien (42)
- 5.2 Metallische Hochtemperaturwerkstoffe (42)
- 7.2 Ingenieurbau (40)
- 1.9 Chemische und optische Sensorik (38)
- 5.4 Multimateriale Fertigungsprozesse (38)
- 9.0 Abteilungsleitung und andere (35)
- 9.2 Versuchsanlagen und Prüftechnik (32)
- 4.2 Material-Mikrobiom Wechselwirkungen (30)
- 5.3 Polymere Verbundwerkstoffe (29)
- 2 Prozess- und Anlagensicherheit (28)
- 4.0 Abteilungsleitung und andere (28)
- 4.5 Kunst- und Kulturgutanalyse (28)
- 5.5 Materialmodellierung (27)
- 5.6 Glas (27)
- S Qualitätsinfrastruktur (27)
- 7.6 Korrosion und Korrosionsschutz (26)
- 2.1 Sicherheit von Energieträgern (25)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (24)
- 9.5 Tribologie und Verschleißschutz (23)
- 9.6 Additive Fertigung metallischer Komponenten (23)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (22)
- VP Vizepräsident (22)
- VP.1 eScience (22)
- 7.1 Baustoffe (21)
- 1.3 Instrumentelle Analytik (19)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (17)
- 5.0 Abteilungsleitung und andere (17)
- 1.6 Anorganische Referenzmaterialien (16)
- S.2 Digitalisierung der Qualitätsinfrastruktur (16)
- 7.7 Modellierung und Simulation (15)
- 1.0 Abteilungsleitung und andere (13)
- 7.0 Abteilungsleitung und andere (13)
- P Präsident (11)
- 3.2 Gefahrguttanks und Unfallmechanik (10)
- 3.5 Sicherheit von Gasspeichern (10)
- P.0 Präsident und andere (10)
- 6.7 Materialsynthese und Design (9)
- 7.3 Brandingenieurwesen (9)
- 6.4 Materialinformatik (8)
- 3.4 Sicherheit von Lagerbehältern (7)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (7)
- 3.6 Elektrochemische Energiematerialien (6)
- S.1 Qualität im Prüfwesen (5)
- 3.0 Abteilungsleitung und andere (4)
- 8.3 Thermografische Verfahren (4)
- 4.6 Molekulare und angewandte Entomologie (3)
- 2.0 Abteilungsleitung und andere (2)
- 2.2 Prozesssimulation (2)
- 2.3 Einstufung von Gefahrstoffen und -gütern (1)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (1)
- 3.3 Sicherheit von Transportbehältern (1)
- KM Kommunikation, Marketing (1)
- PST Präsidiale Stabsstelle (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (68)
The observation of morphological details down to the nanometer range of the outer surface of micro-, submicro- and nanoparticles in a high-resolution scanning electron microscope (SEM) was extended with in-depth observation by enabling the transmission mode in the SEM, i.e. TSEM. The micro- and nanocapsules characterized in this study were fabricated as depots for protective agents to be embedded in innovative self-healing coatings. By combining the two imaging modes (upper and in-depth observation) complementing each other a better characterisation by a more comprehensive interpretation of the 'consistency' of the challenging specimens, e.g. including details 'hidden' beyond the surface or the real specimen shape at all, has been attained. Furthermore, the preparation of the quasi electron transparent samples onto thin supporting foils enables also elemental imaging by energy dispersive X-ray spectroscopy (EDX) with high spatial resolution. Valuable information on the elemental distribution in individual micro-, submicro- and even nanocapsules completes the '3D' high resolution morphological characterization at the same multimodal SEM/TSEM/EDX system.
In welding experiments conducted on heavy wall pipes, the penetration mode (full or partial penetration) occurred to be a significant factor influencing appearance of solidification cracks. To explain the observed phenomena and support further optimization of manufacturing processes, a computational model was developed, which used a sophisticated strategy to model the material. High stresses emerged in the models in regions which showed cracking during experiments. In partial penetration welding, they were caused by the prevention of weld shrinkage due to the cold and strong material below the joint. Another identified factor having an influence on high stress localization is bulging of the weld.
On the role of fluoro-substituted nucleosides in DNA radiosensitization for tumor radiation therapy
(2014)
Gemcitabine (2',2'-difluorocytidine) is a well-known radiosensitizer routinely applied in concomitant chemoradiotherapy. During irradiation of biological media with high-energy radiation secondary low-energy (<10 eV) electrons are produced that can directly induce chemical bond breakage in DNA by dissociative electron attachment (DEA). Here, we investigate and compare DEA to the three molecules 2'-deoxycytidine, 2'-deoxy-5-fluorocytidine, and gemcitabine. Fluorination at specific molecular sites, i.e., nucleobase or sugar moiety, is found to control electron attachment and subsequent dissociation pathways. The presence of two fluorine atoms at the sugar ring results in more efficient electron attachment to the sugar moiety and subsequent bond cleavage. For the formation of the dehydrogenated nucleobase anion, we obtain an enhancement factor of 2.8 upon fluorination of the sugar, whereas the enhancement factor is 5.5 when the nucleobase is fluorinated. The observed fragmentation reactions suggest enhanced DNA strand breakage induced by secondary electrons when gemcitabine is incorporated into DNA.
Das Monitoring von Bauteilen bei Ermüdungsbelastung mit Hilfe der Schallemission liefert eine große Anzahl an Schallemissionsdaten und –parametern. Um diese in einen Zusammenhang mit dem Schadenszustand des Bauteils zu bringen ist es sinnvoll, einen Bezug zu bekannten bruchmechanischen Kenngrößen herzustellen. Dies wird in dieser Arbeit anhand von Ermüdungsversuchen an Platten aus dem Feinkornstahl P460NL1 versucht. Schallemissionssignale aus Ermüdungsrissen mit und ohne Korrosionseinfluss werden analysiert und mit bekannten bruchmechanischen Kenngrößen wie der Risswachstumsrate und dem Spannungsintensitätsfaktor verglichen.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Algal blooms are a frequent phenomenon in nearly all kinds of fresh water. Global warming and eutrophication by waste water, air pollution and fertilizers seem to lead to an increased frequency of occurrence. Many cyanobacteria produce hazardous and quite persistent toxins, which can contaminate the respective water bodies. This may limit the use of the raw water for many purposes. The purification of the contaminated water might be quite costly, which makes a continuous and large scale treatment economically unfeasible in many cases. Due to the obvious risks of algal toxins, an online or mobile detection method would be highly desirable. Several biosensor systems have been presented in the literature for this purpose. In this review, their mode of operation, performance and general suitability for the intended purpose will be described and critically discussed. Finally, an outlook on current developments and future prospects will be given.
Luminescence techniques are among the most widely used detection methods in the life and material sciences. At the core of these methods is an ever-increasing variety of fluorescent reporters (i.e., simple dyes, fluorescent labels, probes, sensors and switches) from different fluorophore classes ranging from small organic dyes and metal ion complexes, quantum dots and upconversion nanocrystals to differently sized fluorophore-doped or fluorophore-labeled polymeric particles. A key parameter for fluorophore comparison is the fluorescence quantum yield (Φf), which is the direct measure for the efficiency of the conversion of absorbed light into emitted light. In this protocol, we describe procedures for relative and absolute determinations of Φf values of fluorophores in transparent solution using optical methods, and we address typical sources of uncertainty and fluorophore class-specific challenges. For relative determinations of Φf, the sample is analyzed using a conventional fluorescence spectrometer. For absolute determinations of Φf, a calibrated stand-alone integrating sphere setup is used. To reduce standard-related uncertainties for relative measurements, we introduce a series of eight candidate quantum yield standards for the wavelength region of ~350950 nm, which we have assessed with commercial and custom-designed instrumentation. With these protocols and standards, uncertainties of 5–10% can be achieved within 2 h.
Für die optische Erwärmung von Prüfteiloberflächen sind Blitz- und Halogenlampen Stand der Technik. Der Vorteil dieser Wärmequellen liegt in ihren relativ geringen Anschaffungskosten bei gleichzeitig hohen Leistungsdichten am Prüfobjekt. Nachteilig ist bei den Halogenlampen die Limitierung der möglichen Modulationsffequenz auf ca. 1 Hz für die Anwendung dieser Quelle in der Lockin-Thermografie. Blitzlampen bieten für gewöhnlich nur eine feste Blitzdauer bei einer geringen Taktrate. Beide Anregungsquellen müssen in Reflexionsanordnung mit Filtern betrieben werden um die entstehende thermische Eigenstrahlung als Störquelle zu eliminieren. Wir stellen Untersuchungen an Hochleistungs-LEDs für den Einsatz in der aktiven Thermografie vor. Diese Lichtquellen werden durch die rasante Entwicklung der möglichen Leistungsdichten nun auch für die thermografische ZfP interessant. Sie zeigen ähnlich dem Laser eine schmale und auf den Werkstoff abstimmbare spektrale Verteilung der Strahlungsleistung bei moderaten Kosten. Die zugrunde liegende Elektrolumineszenz generiert kaum Wärmestrahlung und ermöglicht dadurch die Prüfung während des Erwärmungsvorganges ohne größeren Aufwand. Modulationsfrequenzen über 100 Hz mit thermischen Eindringtiefen < 1 mm sind möglich. Dadurch qualifizieren sich die LEDs zur Anwendung in der Lockin-Thermografie von Metallen und zur oberflächennahen Prüfung von Schichtsystemen. Durch die fast verzögerungsffeie Reaktion der LED auf das steuernde Signal sind nahezu beliebige zeitliche Anregungsformen möglich. Mit solch flexiblen Anregungsformen ließen sich bereits bei den photothermischen Verfahren erfolgreich höhere Tiefenreichweiten und -auflösungen gegenüber den klassischen Methoden der monofrequenten Lockin - und energiereichen Kurzimpuls-Anregung erzielen. Untersuchungen dieser Möglichkeiten im praktischen Einsatz der HochleistungsLEDs werden vorgestellt und mit herkömmlichen Lichtquellen verglichen.
Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made.
A major requirement for the validation of methods assessing the risk associated with engineered nanoparticles (ENPs) is the use of reference materials (RMs). In the present contribution we review available RMs, ongoing projects and characterisation trends in the field. The conclusion is that actual approaches to RMs mostly deal with metrological considerations about single properties of the ENPs, typically their primary size, which can hardly be representative of nanoparticles characteristics in real testing media and therefore, not valid for reliable and comparable toxicological studies. As an alternative, we discussed the convenience and feasibility of establishing multi-parametric RMs for a series of ENPs, focusing on silica nanoparticles (SNPs). As a future perspective, the need to develop RMs based on hybrid nanoparticles is also discussed.
PLR Prüftechnik Linke & Rühe Magdeburg und die BAM Bundesanstalt für Materialforschung und -prüfung Berlin haben in Zusammenarbeit mit anderen Partnern im Laufe der letzten Jahre verschiedene Wirbelstromsysteme zur Prüfung verlegter Schienen auf rissartige Fehler des Typs Head Checks entwickelt. Die Entwicklung dieser Systeme erfolgte mit dem Ziel, ein Hilfsmittel für die Planung von Schieneninstandhaltungsmaßnahmen zu schaffen. Die Systeme haben sich im praktischen Prüfeinsatz bewährt. Hierzu wurde regelmäßig auf den vorhergehenden Tagungen berichtet. Bei der Schieneninstandhaltung kommen unterschiedliche Typen von Schienenbearbeitungsmaschinen zum Einsatz, z. B. Schienenfräs- und Schleifzüge. Seit einiger Zeit wird von Seiten der Schienennetzbetreiber vermehrt ein Qualitätsnachweis nach erfolgter Schienenbearbeitung gefordert. Hierzu wurde ein Wirbelstromprüfsystem entwickelt, dass speziell an die Erfordernisse der Qualitätsüberwachung in Schienenbearbeitungsmaschinen angepasst ist. Das Prüfsystem wird vorgestellt und über erste Erfahrungen aus dem praktischen Einsatz wird berichtet.
Ultrasonic echo and transmission techniques are used in civil engineering on a regular basis. New sensors and data processing techniques have lead to many new applications in the structural investigation as well as quality control. But concrete structures in the nuclear sector have special features and parameters, which pose problems for the methods and instrumentation currently available, e.g. extreme thickness, dense reinforcement, steel liners or special materials. Several innovative ultrasonic techniques have been developed to deal with these issues at least partly in lab experiments and pilot studies. Modern imaging techniques as multi-offset SAFT have been used e. g. to map delaminations. Thick concrete walls have successfully been inspected, partly through a steel liner. Embedded ultrasonic sensors have been designed which will be used in monitoring networks of large concrete structures above and below ground. In addition, sensitive mathematical methods as coda wave interferometry have been successfully evaluated to detect subtle changes in material properties. Examples of measurements and data evaluation are presented.
Indirect UV-absorption spectrometry was shown to be a valuable tool for chemical characterization of functionalized carbon nanotubes (CNTs). It complements data from X-ray photoelectron spectroscopy (XPS) or FTIR analysis since it helps to clarify the type and concentration of functional groups. The principles of indirect application of UV-spectrometry and its mathematical interpretation are discussed. Their facile application, together with their adequate sensitivity and high flexibility, make UV-absorption-based approaches a valuable alternative to fluorescence spectrometry. Here, the approach was applied to the chemical analysis of oxidizing substances on CNTs. For this, pristine CNTs of low but finite oxygen content as well as brominated CNTs were analyzed by reaction in suspension with UV-active thiol reagents and a styrene derivative. It was shown that carefully selected reagents allow differentiation and quantification of bromine and generally oxidizing entities like oxygen. For brominated CNTs, it was shown that physisorbed bromine may dominate the overall bromine content.
Häufig müssen rotierende metallische Bauteile im Betrieb auf das Entstehen rissartiger Fehler überwacht werden. Hierbei besteht im Allgemeinen die Anforderung, trotz extrem schwieriger Umweltbedingungen eine sichere Prüfaussage zu gewährleisten. Es wurden Untersuchungen durchgeführt, inwieweit passive induktive Sensoren in der Lage sind, diese Anforderungen zu erfüllen. Hierzu wurden verschiedene einfache Sensormodelle aufgebaut und an verschiedenen Vergleichsfehlern erprobt. Die Ergebnisse der Untersuchungen werden vorgestellt. Insbesondere die Möglichkeiten und Grenzen dieser einfachen Sensortypen werden herausgearbeitet.
A fiber Bragg grating (FBG) strain patch specially adapted for long-term and high-strain applications has been developed and characterized. The design concept for the patch is based on a glass-fiber reinforced plastic (gfrp) carrier material. The developed concept for the FBG integration into the carrier material was derived from reliable integration procedure of FBG sensors into composite structures. The patches' temperature sensitivity, strain gauge factor, fiber–matrix interface adhesion and fatigue behavior were characterized. As a result, FBG strain patches with linear temperature and strain behavior, as well as excellent fatigue resistance, were developed and can be used as part of a monitoring system for advanced composite materials in aerospace structures or wind turbine power plants.
GMR sensors are widely used in many industrial segments such as information technology, automotive, automation and production, and safety applications. Each area requires an adaption of the sensor arrangement in terms of size adaption and alignment with respect to the field source involved. This paper deals with an analysis of geometric sensor parameters and the arrangement of GMR sensors providing a design roadmap for non-destructive testing (NDT) applications. For this purpose we use an analytical model simulating the magnetic flux leakage (MFL) distribution of surface breaking defects and investigate the flux leakage signal as a function of various sensor parameters. Our calculations show both the influence of sensor length and height and that when detecting the magnetic flux leakage of µm sized defects a gradiometer base line of 250 µm leads to a signal strength loss of less than 10% in comparison with a magnetometer response. To validate the simulation results we finally performed measurements with a GMR magnetometer sensor on a test plate with artificial µm-range cracks. The differences between simulation and measurement are below 6%. We report on the routes for a GMR gradiometer design as a basis for the fabrication of NDT-adapted sensor arrays. The results are also helpful for the use of GMR in other application when it comes to measure positions, lengths, angles or electrical currents.
A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques
(2012)
The success of modern methods in analytical chemistry sometimes obscures the problem that the ever increasing amount of analytical data does not necessarily give more insight of practical relevance. As alternative approaches, toxicity- and bioactivity-based assays can deliver valuable information about biological effects of complex materials in humans, other species or even ecosystems. However, the observed effects often cannot be clearly assigned to specific chemical compounds. In these cases, the establishment of an unambiguous cause-effect relationship is not possible. Effect-directed analysis tries to interconnect instrumental analytical techniques with a biological/biochemical entity, which identifies or isolates substances of biological relevance. Successful application has been demonstrated in many fields, either as proof-of-principle studies or even for complex samples. This review discusses the different approaches, advantages and limitations and finally shows some practical examples. The broad emergence of effect-directed analytical concepts might lead to a true paradigm shift in analytical chemistry, away from ever growing lists of chemical compounds. The connection of biological effects with the identification and quantification of molecular entities leads to relevant answers to many real life questions.
Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography mass spectrometry/mass spectrometry).
Combustion of peroxy-fuels
(2011)
The diffusion flames of organic peroxides exhibit quite different characteristics than hydrocarbons. What makes them interesting to study is their fast burning behaviour. As a result the flame temperature enhances and so does the thermal radiation. Due to all these they demand safe handling during processing. However, they can be utilised at several places in different industries where a fuel with fast burning, high temperature and intense radiation are desired. Some of the possibilities to use them as a main or supporting fuel in a wide range of industrial utilities are the major content of this paper.
The use of energetic materials as a main fuel in high temperature process
industries are not known to the scientific community as such. This paper
highlights some of the features and advantages of using organic peroxides
especially di-tert-butyl peroxide (DTBP) in high temperature process industries.
The feasibility of using DTBP as a main or supporting fuel in process industries
have also been justified with the help of Computational Fluid Dynamics (CFD)
simulations. For peroxides requirement of less fuel and air for the same amount
of heat flux has been shown. The resulted emission from the combustion of
DTBP is also discussed.
Triacetone triperoxide (TATP) is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L-1 (water) were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies—not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications.
Ground penetrating radar (GPR) was used to characterize the frequency-dependent dielectric relaxation phenomena in ordinary Portland cement (OPC) hydration in concrete changing from fresh to hardened state. The study was experimented by measuring the changes of GPR A-scan waveforms over a period of 90 days, and processed the waveforms with short-time Fourier transform (STFT) in joint time-frequency analysis (JTFA) domain rather than a conventional time or frequency domain alone. The signals of the direct wave traveled at the concrete surface and the reflected wave from an embedded steel bar were transformed with STFT, in which the changes of peak frequency over ages were tracked. The peak frequencies were found to increase with ages and the patterns were found to match closely with primarily the well-known OPC hydration process and secondarily, the evaporation effect. The close match is contributed to the simultaneous effects converting free to bound water over time, on both conventional OPC hydration and dielectric relaxation mechanisms.
Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.
Phosphorus-based flame retardancy mechanisms - Old hat or a starting point for future development?
(2010)
Different kinds of additive and reactive flame retardants containing phosphorus are increasingly successful as halogen-free alternatives for various polymeric materials and applications. Phosphorus can act in the condensed phase by enhancing charring, yielding intumescence, or through inorganic glass formation; and in the gas phase through flame inhibition. Occurrence and efficiency depend, not only on the flame retardant itself, but also on its interaction with pyrolysing polymeric material and additives. Flame retardancy is sensitive to modification of the flame retardant, the use of synergists/adjuvants, and changes to the polymeric material. A detailed understanding facilitates the launch of tailored and targeted development.
The class Dothideomycetes (along with Eurotiomycetes) includes numerous rock-inhabiting fungi (RIF), a group of ascomycetes that tolerates surprisingly well harsh conditions prevailing on rock surfaces. Despite their convergent morphology and physiology, RIF are phylogenetically highly diverse in Dothideomycetes. However, the positions of main groups of RIF in this class remain unclear due to the lack of a strong phylogenetic framework. Moreover, connections between rock-dwelling habit and other lifestyles found in Dothideomycetes such as plant pathogens, saprobes and lichen-forming fungi are still unexplored. Based on multigene phylogenetic analyses, we report that RIF belong to Capnodiales (particularly to the family Teratosphaeriaceae s.l.), Dothideales, Pleosporales, and Myriangiales, as well as some uncharacterised groups with affinities to Dothideomycetes. Moreover, one lineage consisting exclusively of RIF proved to be closely related to Arthoniomycetes, the sister class of Dothideomycetes. The broad phylogenetic amplitude of RIF in Dothideomycetes suggests that total species richness in this class remains underestimated. Composition of some RIF-rich lineages suggests that rock surfaces are reservoirs for plant-associated fungi or saprobes, although other data also agree with rocks as a primary substrate for ancient fungal lineages. According to the current sampling, long distance dispersal seems to be common for RIF. Dothideomycetes lineages comprising lichens also include RIF, suggesting a possible link between rock-dwelling habit and lichenisation.
Shape memory polymers (SMP) belong to the class of stimuli-responsive materials and have generated significant research interest. Their capability to retain an imposed, temporary shape and to recover the initial, permanent shape upon exposure to an external stimulus depends on the "functional determinants", which in simplistic terms, can be divided into structural/morphological and processing/environmental factors. The primary aim of the first part of this review is to reflect the knowledge about these fundamental relationships. In a next step, recent advances in shape memory polymer composites are summarized. In contrast to earlier reviews, studies on the impairment of shape memory properties through various factors, such as aging, compression and hibernation, lubricants, UV light and thermo-mechanical cycling, are extensively reviewed. Apart from summarizing the state-of-the-art in SMP research, recent progress is commented.
The changes in the sonic surface wave velocity of concrete under stress were investigated in this paper. Surface wave velocities at
sonic frequency range were measured on a prismatic concrete specimen undergoing several cycles of uniaxial compression. The
loading was applied (or removed) gradually in predefined small steps (stress-controlled). The surface wave velocity was measured
at every load step during both loading and unloading phases. Acoustic Emission (AE) test was conducted simultaneously to
monitor the microcracking activities at different levels of loading. It was found that the sonic surface wave velocity is highly stress
dependent and the velocity-stress relationship follows a particular trend. The observed trend could be explained by a combination
of acoustoelasticity and microcracking theories, each valid over a certain range of applied stresses. Having measured the velocities
while unloading, when the material suffers no further damage, the effect of stress and damage could be differentiated. The slope
of the velocity-stress curves over the elastic region was calculated for different load cycles. This quantity was normalized to yield a
dimensionless nonlinear parameter. This parameter generally increases with the level of induced damage in concrete.
Die zerstörungsfreie Oberflächenprüfung an verlegten Eisenbahnschienen mit Wirbelstrom hat in den letzten Jahren durch ständige Weiterentwicklung und Verifizierung enorm an Bedeutung gewonnen. Es wurde u.a. angestrebt zuverlässige Planungsgrößen für den Einsatz von Instandhaltungsmaßnahmen zu erhalten, durch deren gezielten Einsatz Risswachstum unterbunden werden kann. Die Ursache für das Wachstum von Rissen in der Schiene liegt in der Materialermüdung des Werkstoffes infolge der Betriebsbelastungen im RadSchiene-Kontakt. Nach einer gewissen Beanspruchungsdauer kommt es an den Kontaktflächen der Fahrkante zu einer Kaltverfestigung des Schienenstahls. Durch fortschreitende Verfestigung des kontaktbeanspruchten Oberflächenbereichs der gehärteten Schicht wird der Werkstoff spröde und es bilden sich feine Risse aus. Die Risse wachsen anfangs unter einem flachen Winkel in das Schieneninnere hinein, neigen dann aber ab einem gewissen Stadium dazu in das Innere des Schienenkopfes abzukippen, was im Extremfall zu einem Schienenbruch führen kann. Diese Rollkontaktermüdungsrisse, auch genannt Head Checks, entstehen bevorzugt in der Fahrkante von bogenäußeren Schienen. Die Anwendung der Wirbelstromprüfung an der Schiene wurde bisher zur Ermittlung der Schädigungstiefe dieser Rollkontaktermüdungsrisse eingesetzt. Das Wirbelstromverfahren besitzt die Eigenschaft, sehr empfindlich auf alle Veränderungen der Materialeigenschaften an der Oberfläche zu reagieren. Daher wurde festgestellt, dass sich neben der Detektion von Rissen auch Fehler wie Eindrückungen oder Schlupfwellen, bis hin zu Materialveränderungen durch Schweißen oder Aufhärtungen in der Schienenoberfläche bestimmen lassen. Die Wirbelstromprüfung besitzt daher das Potenzial, mögliche Orte der Entstehung von Ermüdungsrissen in einem extrem frühzeitigen Stadium nachzuweisen. Ziel ist es, die rissgefährdeten Zonen schon im Zustand der Kaltverfestigung zu identifizieren. Dadurch können sich neue Aspekte für die präventive Schieneninstandhaltung ergeben.
Statistical analysis of tomographic reconstruction algorithms by morphological image characteristics
(2010)
We suggest a procedure for quantitative quality control of tomographic reconstruction algorithms. Our task-oriented evaluation focuses on the correct reproduction of phase boundary length and has thus a clear implication for morphological image analysis of tomographic data. Indirectly the method monitors accurate reproduction of a variety of locally defined critical image features within tomograms such as interface positions and microstructures, debonding, cracks and pores. Tomographic errors of such local nature are neglected if only global integral characteristics such as mean squared deviation are considered for the evaluation of an algorithm. The significance of differences in reconstruction quality between algorithms is assessed using a sample of independent random scenes to be reconstructed. These are generated by a Boolean model and thus exhibit a substantial stochastic variability with respect to image morphology. It is demonstrated that phase boundaries in standard reconstructions by filtered backprojection exhibit substantial errors. In the setting of our simulations, these could be significantly reduced by the use of the innovative reconstruction algorithm DIRECTT.
Die Analytik von Phthalaten (DMP bis DEHP) in der Luft ist mit thermischer Desorption unter Verwendung von Quarzwolle als Adsorbens erfolgreich realisierbar. Dies wurde durch eine Methodenvalidierung bestätigt. Es wurden sowohl Messungen im Innenraum als auch in Emissionskammern vorgenommen. In den Emissionskammermessungen wurden mögliche Senkeneffekte der Kammeroberfläche (Glas) untersucht. Unter Zuhilfenahme der idealen Abklingkurve wird bestätigt, dass diese Oberfläche eine Senke darstellt.
Cold cracking resistance is a relevant evaluation criterion for welded joints and affected by residual stresses which result from the welding procedure. Compressive residual stresses can thereby have a positive influence on preventing cracking. A unique possibility of generating compressive residual stresses already during the welding procedure is offered by the so-called Low Transformation Temperature (LTT) filler wires. Compared to conventional wires, these materials show decreased phase transformation temperatures which can work against the cooling-specific contraction. In consequence, distinct compressive residual stresses can be observed within the weld and adjacent areas. The strength of these fillers makes them potentially applicable to high-strength steel welding. Investigations were carried out to determine the phase transformation behaviour of different LTT-filler materials. Transformation temperatures were identified using Single Sensor Differential Thermal Analysis (SS-DTA). Additionally Synchrotron radiation was used to measure the transformation kinetics of all involved crystalline phases during heating and cooling of a simulated weld thermal cycle.
For the safety and cost efficiency of welded high-strength steel structures, precise knowledge of the level and distribution of welding- and cooling-specific stresses and residual stresses is essential, since they exert a decisive influence on strength, crack resistance, and finally on the bearable service load. This paper presents innovative filler materials, of which the phase transformation temperature was deliberately adjusted via the chemical composition. The transformation behaviour of these martensitic Low Transformation Temperature (LTT-) filler materials shows direct effects on the local residual stresses in the weld and the HAZ. These effects can purposefully be exploited to counteract the thermally induced shrinkage of the material and to produce significant compressive residual stresses in the weld. Comparative welding experiments were carried out on 690 MPa high-strength base materials using various LTT-filler materials. High energy synchrotron radiation was used for residual stress measurement. Particularly the use of high energy synchrotron radiation makes it possible to detect the residual stress condition fast without destruction of material. Thereby, residual stress depth gradients can be determined simultaneously without removing material. In steel, gradients of up to 150 µm can be resolved in such a way. Furthermore, the application of high energy radiation permits determination of residual stresses of any available residual austenite contents. Results show significant dependence of transformation temperatures on the resulting residual stress level and distribution.
Novel approaches of tunable devices for millimeter wave applications based on liquid crystal (LC) are presented. In the first part of the paper, a novel concept of a tunable LC phase shifter realized in Low Temperature Cofired Ceramics technology is shown while the second part of the paper deals with a tunable high-gain antenna based on an LC tunable reflectarray. The reflectarray features continuously beam scanning in between ±25°. Also first investigations on radiation hardness of LCs are carried out, indicating that LCs might be suitable for space applications.
Aflatoxins, a group of structurally related mycotoxins, are well known for their
toxic and carcinogenic effects in humans and animals. Aflatoxin derivatives and protein
conjugates are needed for diverse analytical applications. This work describes a reliable
and fast synthesis of novel aflatoxin derivatives, purification by preparative HPLC and
characterisation by ESI-MS and one- and two-dimensional NMR. Novel aflatoxin bovine
serum albumin conjugates were prepared and characterised by UV absorption and
MALDI-MS. These aflatoxin protein conjugates are potentially interesting as immunogens
for the generation of aflatoxin selective antibodies with novel specificities.
Neben dem Stammgelände in Berlin Zehlendorf-Steglitz,
besitzt die Bundesanstalt für Materialforschung und -prüfung
(BAM) seit Mitte der 90ziger Jahre noch weitere Liegenschaften
in und bei Berlin. Zweiggelände befinden sich in Berlin,
in Zehlendorf-Steglitz und im Wissenschaftspark (WISTA) in
Adlershof.
Von besonderer Bedeutung ist das 12 km2 große Freiversuchsgelände
mit einem Sprengplatz von 400 m Durchmesser
für Brand- und Explosionsversuche bis 150 kg TNT
in Horstwalde, das ca. 50 km südlich von Berlin entfernt ist.
Die BAM ist als Benannte Stelle im Rahmen der europäischen
Richtlinien 97/23/EG über Druckgeräte (PED) [1] und
1999/36/EG über ortsbewegliche Druckgeräte (TPED) [2] bei
der Zertifizierung von Ausrüstungsteilen für Druckgefäße (PED
und TPED), Baugruppen (PED) und der Neubewertung von
Baumustern (TPED) tätig. In diesem Beitrag wird die Zertifizierung
einschließlich der dabei gewonnenen Erfahrungen
und in der Praxis auftretenden Problemen auf Seiten der
Hersteller und Benannten Stellen bei der Zertifizierung nach
diesen europäischen Richtlinien vorgestellt. Die wesentlichen
Probleme ergeben sich aus der Zuordnung der Druckgeräte
zu entsprechenden Kategorien innerhalb der Richtlinien und
aus der Überschneidung mit anderen europäischen und
nationalen Richtlinien.
Die Technische Regel für Anlagensicherheit (TRAS) 410 mit
dem Titel "Erkennen und Beherrschen exothermer Reaktionen"
stellt im Rahmen der Betrachtung der thermischen
Prozesssicherheit eine Anleitung zur systematischen Erarbeitung
von Gefahren bei chemischen Stoffumwandlungen
im Industriemaßstab dar. Sie unterstützt bei der Bewertung
der Gefahren und bei der Erstellung von Maßnahmen, um
Störfälle zu verhindern. Am Beispiel der exotherm ablaufenden
Synthese von tert.-Butylperoxypivalat, einem organischen
Peroxid, wird die Vorgehensweise dargestellt. Organische
Peroxide sind als thermisch instabile Verbindungen bekannt
und besitzen dadurch ein zusätzliches Gefahrenpotential.
Neue Ansätze für die sichere Auslegung von Treibgasspeichern - Probabilistik und Risikoansatz
(2004)
Die Beurteilung neuer Techniken bezüglich der Gefährdung
von Dritten wird immer weniger mit Hilfe traditioneller, auf
Erfahrung und Iteration basierenden Betrachtungsweisen
hinreichend möglich. Deshalb werden zunehmend probabilistische
Analysen und Risikobetrachtungen erforderlich. Diese
Verfahren bieten zudem die Möglichkeiten, ein System
z. B. gegenüber Eigengewicht oder Wartungsaufwand bei
gleicher oder auch besserer Sicherheit zu optimieren.
Vor diesem Hintergrund werden zunächst die Begriffe Risiko
und Chance bzw. Gefahr und Sicherheit erläutert.
Am Beispiel von Treibgasspeichern wie sie auch für die
Speicherung von Wasserstoff in Fahrzeugen eingesetzt werden
wird gezeigt, dass die bisherige, deterministische
Betrachtungsweise von Druckbehältern und deren statische
Sicherheit (z. B. gegen Bersten) kein hinreichendes Maß der
Sicherheit als Gegenteil von Gefahr darstellt oder sogar
irreführend für die richtige Einschätzung ist.
Nach nationalen und internationalen Vorschriften müssen
Armaturen und Anlagenteile für hoch verdichteten Sauerstoff
ausbrennsicher sein. Diese Forderung kann technisch dadurch
erreicht werden, dass sicherheitstechnisch geeignete
nichtmetallische und metallische Werkstoffe verwendet werden.
Für die Auswahl geeigneter metallischer Werkstoffe sind
der Verwendungszweck der Armatur, die Betriebsbedingungen
sowie werkstoffspezifische Parameter zu berücksichtigen.
Einige metallische Werkstoffe besitzen gute Materialeigenschaften,
lassen sich leicht be- bzw. verarbeiten und
sind kostengünstig in der Beschaffung, dürfen aber aufgrund
ihres ungünstigen Abbrandverhaltens in Sauerstoff nicht eingesetzt
werden. Es besteht daher ein großes Interesse, den
sicherheitstechnischen Beschränkungen dieser Werkstoffe
durch geeignete Maßnahmen entgegenzuwirken. Eine mögliche
Lösung stellt die Beschichtung dieser Werkstoffe beispielsweise
mit Keramik dar, um den unmittelbaren Kontakt
mit dem Sauerstoff zu verhindern. Um den Einfluss dieser
Keramikschichten auf das Abbrandverhalten metallischer
Werkstoffe zu untersuchen, wird die im Standard ASTM G124
[1] beschriebene Apparatur und das in der einschlägigen
Literatur beschriebene Bewertungsverfahren verwendet. Die
Ergebnisse zeigen, dass für keramikbeschichtete metallische
Werkstoffe ein Abbrand erst bei höheren Sauerstoffdrücken
erfolgt.
Seit langer Zeit ist bekannt, dass ungünstige Lagerungsbedingungen
bei brennbaren Schüttgütern und Stäuben zur
Selbstentzündung führen können. Die meisten Studien zu
diesem Thema beziehen sich allerdings auf Umgebungsbedingungen
(d. h. mit einem Sauerstoff-Volumenanteil von
21 % in der Schüttungsumgebung). In einigen technischen
Anwendungen jedoch wird brennbares Schüttgut oder Staub
unter einer Gasatmosphäre mit reduziertem Sauerstoff-
Volumenanteil gelagert und verarbeitet (Inertisierung). Dabei
ist zunächst nicht klar, bis zu welchem Ausmaß der Sauerstoff-
Volumenanteil reduziert werden muss, um bei einer
vorgegebenen Lagerungstemperatur Selbstentzündung auszuschließen.
Neben dem Sauerstoffvolumenanteil können
auch der Feuchtegehalt der Schüttung sowie die relative Luftfeuchtigkeit
in der Schüttungsumgebung den Vorgang der
Selbstentzündung beeinflussen.
Die hier vorgestellten experimentellen Untersuchungen beschreiben
zum einen den Einfluss des Sauerstoff-Volumenanteils
auf die Selbstentzündungstemperatur (SET) von
Schüttgütern und Stäuben. Es wurde beobachtet, dass die
SET mit abnehmendem Sauerstoff-Volumenanteil in der
Schüttungsumgebung anstieg. Jedoch traten auch bei sehr
kleinem Sauerstoff-Volumenanteil noch signifikante Temperaturerhöhungen
in den untersuchten Proben auf.
Zum zweiten wurde der Einfluss der Feuchte auf die SET
untersucht. Dabei konnte gezeigt werden, dass unterkritisch
gelagerte Schüttungen durch Kondensation von Wasserdampf
oder Zugabe von Wasser auf die Oberfläche der
Schüttung in einen überkritischen Zustand gebracht werden
konnten.
Neben den experimentellen Untersuchungen wurde ein numerisches
Modell entwickelt, mit dessen Hilfe sich der
Selbsterwärmungsprozess bis hin zur Zündung von Schüttgütern
berechnen lässt. Anwendungen findet dieses Modell
für die Lagerung von Schüttgütern, Stäuben, Feststoffen
sowie Abfällen.
Die Diskussionen mit Fachleuten im Rahmen der Änderung
der Seveso-II-Richtlinie [1] haben gezeigt, dass sowohl Prufergebnisse
als auch Erfahrungen mit Ammoniumnitrat und
ammoniumnitrathaltigen Zubereitungen im Laufe der Zeit in
Vergessenheit geraten sind.
Die geanderte Seveso-II-Richtlinie berucksichtigt nunmehr
bei den Eintragungen fur Ammoniumnitrat und ammoniumnitrathaltige
Zubereitungen und den damit verbundenen
Mengenschwellen deren gefahrliche Eigenschaften.
Auf nationaler und internationaler Ebene werden immer wieder
Diskussionen bezuglich der gefahrlichen Eigenschaften
dieser Produkte, den Einflussfaktoren, den Prufmethoden
und deren Aussagefahigkeit gefuhrt.
Im folgenden sollen einige Prufmethoden und Einflussgro©¬en
auf die gefahrlichen Eigenschaften von Ammoniumnitrat und
ammoniumnitrathaltigen Zubereitungen vorgestellt werden.
Charakterisierung einer durch Überlast geschädigten GFK-Platte mit Thermografie und Ultraschall
(2013)
Eine GFK-Platte mit eingefräster Nut wurde in einem Zugversuch mit
ca. 90 kN belastet, was zu einer sichtbaren Veränderung an den Seitenflächen führte.
Anschließend wurde die Platte mit Ultraschall und Thermografie auf innere Schädigungen untersucht. Beide Verfahren konnten räumlich ausgedehnte Bereiche mit zahlreichen Anzeigen nachweisen, jedoch keine geschlossene Fläche. Mit UT wurden außerdem porenreiche oberflächennahe Schichten in dem Material detektiert. Diese Poren verringerten die Nachweisempfindlichkeit beider Messverfahren.
Faserverbundwerkstoffe wie kohlefaserverstärkte Kunststoffe CFK sind vergleichsweise schwer mit Ultraschall zu prüfen, weil die starke Dämpfung, der inhomogene Aufbau und die akustische Anisotropie die Wellenausbreitung behindern bzw. komplizieren. Die Folge ist, dass die Ansprüche an die Prüfung oft stark reduziert werden müssen. Die vorgestellte Prüftechnik nutzt die Möglichkeiten der räumlichen Fokussierung und des zweidimensionalen Winkelscans von Matrix Phased Array Prüfköpfen MPA in Kombination mit Echosignalüberlagerungsalgorithmen für eine substantielle Verbesserung der Auflösung und des Signal-Rausch-Verhältnisses. Sowohl bei der Ansteuerung des MPA als auch bei der Auswertung wird die Anisotropie des Werkstoffs berücksichtigt. Das MPA wird über die Oberfläche bewegt und an einer Anzahl von Messpunkten werden zweidimensionale Winkelscans durchgeführt. Das Ergebnis sind räumliche Echohöhenverteilungen, aus denen Schnittbilder oder auch Volumendarstellungen erzeugt werden können.
Anhand von Messungen an CFK-Platten mit Flachbodenbohrungen KSR 1 und 2 sollen die Empfindlichkeit und das Auflösungsvermögen der Prüftechnik demonstriert werden. Weiterhin werden Untersuchungen an Impaktschäden gezeigt, die typischerweise bei Faserverbundwerkstoffen bei starken punktförmigen Belastungen auftreten.
Dieser Beitrag fasst die Untersuchungsergebnisse zu den Verfahrensgrenzen der Blitzthermografie zur Ortung und Charakterisierung von Fehlstellen in Metallen zusammen. Regeln zur Abschätzung von Eindringtiefe und Tiefenauflösung werden vorgestellt und überprüft. Weiterhin werden Vorgehensweisen zur Optimierung des Intensitätskontrastes von Fehlstellenanzeigen vorgestellt.
Einfache analytische Abschätzungen werden durch eine Vielzahl von experimentellen Untersuchungen an Kupfer- und Stahl-Probekörpern ergänzt. Dabei wurden sowohl die Parameter der Blitzlichtanregung als auch der Messwerterfassung umfassend variiert.