Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (2054)
- Beitrag zu einem Tagungsband (379)
- Forschungsbericht (19)
- Sonstiges (12)
- Beitrag zu einem Sammelband (10)
- Buchkapitel (9)
- Corrigendum (3)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Dissertation (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (2254)
- Deutsch (232)
- Mehrsprachig (3)
- Portugiesisch (1)
Schlagworte
- Additive manufacturing (69)
- Fluorescence (55)
- Nanoparticles (48)
- Concrete (46)
- SAXS (46)
- Corrosion (37)
- Ultrasound (37)
- MALDI-TOF MS (36)
- Quantum yield (36)
- Non-destructive testing (32)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (440)
- 6 Materialchemie (437)
- 1 Analytische Chemie; Referenzmaterialien (360)
- 7 Bauwerkssicherheit (219)
- 9 Komponentensicherheit (215)
- 5 Werkstofftechnik (209)
- 4 Material und Umwelt (194)
- 6.3 Strukturanalytik (167)
- 8.5 Röntgenbildgebung (139)
- 6.1 Oberflächen- und Dünnschichtanalyse (102)
Paper des Monats
- ja (68)
Die ZfP versucht mit Hilfe von Messdaten, die sie aus z. B. einer Impuls-Echo-Messung gewinnt, Rückschlüsse auf die innere Struktur eines Objektes zu ziehen. Bei Betonbauteilen sollen im Besonderen Verpressfehler, die dann zur Korrosion und damit zur einer Beeinträchtigung der Standsicherheit und Dauerhaftigkeit des Konstruktion (z. B. einer Spannbetonbrücke) führen können, schnell und mit einer hohen Sicherheit aus den Messdaten lokalisiert werden. Das konventionellen SAFT oder FT-SAFT-Verfahren liefern in Verbindung mit einer Phasenauswertung einen schnellen und sicheren Hinweis darauf, dass ein Lufteinschluss/Defekt vorliegt. Darüber hinaus können jedoch Rückausbreitungs-Verfahren, wenn ein gutes Geschwindigkeitsprofil vorliegt, eine wesentlich bessere Lokalisierung des Defekts bieten als SAFT-Verfahren, jedoch mit dem Nachteil, dass sie sehr zeit- und rechenintensiv sind, vor allem im Dreidimensionalen. Als Mittelweg kann hierzu die "One-Way"-Methode dienen. Diese Methode verwendet Pseudo-Differential-Operatoren und ist sehr robust auch bei relativ groben Geschwindigkeitsprofilen. Sie wird an Beispielen aus der Bauwerkdiagnose mit den konventionellen Verfahren verglichen.
Die steigenden Anforderungen im Schienenverkehr haben u. a. wachsende Betriebsbeanspruchungen für das Führungselement Schiene zur Folge. Auf Strecken mit hohen Belastungen wird dadurch die Entstehung von Rollkontaktermüdungsrissen, den sog. Head Checks, begünstigt. Für die Quantifizierung von Schäden im Hinblick auf eine optimierte Instandhaltung, setzt die DB AG daher seit einigen Jahren die Wirbelstromprüfung an Schienen ein. Es wurde ein Wirbelstromprüfsystem speziell für die Detektion und Bewertung von Head Checks auf der Schienenstahlsorte R260 entwickelt. Um den Instandhaltungsaufwand möglichst gering zu halten, unterliegen Eisenbahnschienen einer ständigen technologischen Weiterentwicklung durch die Hersteller. Durch Verbesserung der Schienenstahlsorten soll ein größerer Widerstand gegen die Bildung von Rollkontaktermüdungsrissen erreicht werden. Anhand von Streckenversuchen der DB AG in den letzten Jahren konnte festgestellt werden, dass tatsächlich eine Verminderung der Risswachstumsgeschwindigkeit erzielt wurde. Dafür zeigten sich im Vergleich zur Stahlsorte R260 abweichende Rissgeometrien, geringere Abstände zwischen den Ermüdungsrissen und somit eine größere Dichte des Rissfeldes. Die daraus resultierenden Folgen für die Ergebnisse der Wirbelstromprüfung werden hier erläutert. Praktische Prüferfahrungen an Schienenstahlsorten mit höherer Festigkeit werden vorgestellt.
Triacetone triperoxide (TATP) is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L-1 (water) were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies—not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications.
Faserverbundwerkstoffe wie kohlefaserverstärkte Kunststoffe CFK sind vergleichsweise schwer mit Ultraschall zu prüfen, weil die starke Dämpfung, der inhomogene Aufbau und die akustische Anisotropie die Wellenausbreitung behindern bzw. komplizieren. Die Folge ist, dass die Ansprüche an die Prüfung oft stark reduziert werden müssen. Die vorgestellte Prüftechnik nutzt die Möglichkeiten der räumlichen Fokussierung und des zweidimensionalen Winkelscans von Matrix Phased Array Prüfköpfen MPA in Kombination mit Echosignalüberlagerungsalgorithmen für eine substantielle Verbesserung der Auflösung und des Signal-Rausch-Verhältnisses. Sowohl bei der Ansteuerung des MPA als auch bei der Auswertung wird die Anisotropie des Werkstoffs berücksichtigt. Das MPA wird über die Oberfläche bewegt und an einer Anzahl von Messpunkten werden zweidimensionale Winkelscans durchgeführt. Das Ergebnis sind räumliche Echohöhenverteilungen, aus denen Schnittbilder oder auch Volumendarstellungen erzeugt werden können.
Anhand von Messungen an CFK-Platten mit Flachbodenbohrungen KSR 1 und 2 sollen die Empfindlichkeit und das Auflösungsvermögen der Prüftechnik demonstriert werden. Weiterhin werden Untersuchungen an Impaktschäden gezeigt, die typischerweise bei Faserverbundwerkstoffen bei starken punktförmigen Belastungen auftreten.
GMR sensors are widely used in many industrial segments such as information technology, automotive, automation and production, and safety applications. Each area requires an adaption of the sensor arrangement in terms of size adaption and alignment with respect to the field source involved. This paper deals with an analysis of geometric sensor parameters and the arrangement of GMR sensors providing a design roadmap for non-destructive testing (NDT) applications. For this purpose we use an analytical model simulating the magnetic flux leakage (MFL) distribution of surface breaking defects and investigate the flux leakage signal as a function of various sensor parameters. Our calculations show both the influence of sensor length and height and that when detecting the magnetic flux leakage of µm sized defects a gradiometer base line of 250 µm leads to a signal strength loss of less than 10% in comparison with a magnetometer response. To validate the simulation results we finally performed measurements with a GMR magnetometer sensor on a test plate with artificial µm-range cracks. The differences between simulation and measurement are below 6%. We report on the routes for a GMR gradiometer design as a basis for the fabrication of NDT-adapted sensor arrays. The results are also helpful for the use of GMR in other application when it comes to measure positions, lengths, angles or electrical currents.
Am Beispiel der Ertüchtigung einer Brücke in Bremen wird gezeigt, wie mit den zerstörungsfreien Prüfverfahren (ZfP) Radar- und Ultraschall die genau Lage vorgespannte Bewehrung gefunden bzw. bestätigt werden kann. Im Rahmen von Ertüchtigungsmaßnahmen an Spannbetonbrücken werden häufig Kernbohrungen durchgeführt, die die vorhandenen Spannbewehrungen nicht beschädigen dürfen. Es wird die Vorgehensweise beschrieben, wie mit ZfP ein wesentlicher Beitrag geleistet wird, das Risiko einer Beschädigung zu minimieren und somit eine bessere Planungssicherheit für die Ertüchtigungsmaßnahmen zu schaffen. Dabei werden auch die Grenzen der beiden Verfahren aufgezeigt.
Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography mass spectrometry/mass spectrometry).
A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques
(2012)
The success of modern methods in analytical chemistry sometimes obscures the problem that the ever increasing amount of analytical data does not necessarily give more insight of practical relevance. As alternative approaches, toxicity- and bioactivity-based assays can deliver valuable information about biological effects of complex materials in humans, other species or even ecosystems. However, the observed effects often cannot be clearly assigned to specific chemical compounds. In these cases, the establishment of an unambiguous cause-effect relationship is not possible. Effect-directed analysis tries to interconnect instrumental analytical techniques with a biological/biochemical entity, which identifies or isolates substances of biological relevance. Successful application has been demonstrated in many fields, either as proof-of-principle studies or even for complex samples. This review discusses the different approaches, advantages and limitations and finally shows some practical examples. The broad emergence of effect-directed analytical concepts might lead to a true paradigm shift in analytical chemistry, away from ever growing lists of chemical compounds. The connection of biological effects with the identification and quantification of molecular entities leads to relevant answers to many real life questions.
Charakterisierung einer durch Überlast geschädigten GFK-Platte mit Thermografie und Ultraschall
(2013)
Eine GFK-Platte mit eingefräster Nut wurde in einem Zugversuch mit
ca. 90 kN belastet, was zu einer sichtbaren Veränderung an den Seitenflächen führte.
Anschließend wurde die Platte mit Ultraschall und Thermografie auf innere Schädigungen untersucht. Beide Verfahren konnten räumlich ausgedehnte Bereiche mit zahlreichen Anzeigen nachweisen, jedoch keine geschlossene Fläche. Mit UT wurden außerdem porenreiche oberflächennahe Schichten in dem Material detektiert. Diese Poren verringerten die Nachweisempfindlichkeit beider Messverfahren.
Dieser Beitrag fasst die Untersuchungsergebnisse zu den Verfahrensgrenzen der Blitzthermografie zur Ortung und Charakterisierung von Fehlstellen in Metallen zusammen. Regeln zur Abschätzung von Eindringtiefe und Tiefenauflösung werden vorgestellt und überprüft. Weiterhin werden Vorgehensweisen zur Optimierung des Intensitätskontrastes von Fehlstellenanzeigen vorgestellt.
Einfache analytische Abschätzungen werden durch eine Vielzahl von experimentellen Untersuchungen an Kupfer- und Stahl-Probekörpern ergänzt. Dabei wurden sowohl die Parameter der Blitzlichtanregung als auch der Messwerterfassung umfassend variiert.
Es wird ein Verfahren zur Röntgenabbildung schwach absorbierender Objekte vorgestellt. Als kontrastgebender Effekt wird die Röntgenrefraktion an Ober- und Grenzflächen ausgenutzt. Zur Erzeugung eines sogenannten Dunkelfeldes wird ein schwach gekrümmter Transmissionskristall eingesetzt, der lokal, d.h. in einem kleinen Ausschnitt des Einstrahlquerschnitts, die Bragg-Bedingung erfüllt. Innerhalb dieser Zone erscheinen die durch Refraktion abgelenkten Strahlkomponenten als hell leuchtende Interface-Strukturen. Die Synthese mehrerer Dunkelfeldstreifen ergibt hochaufgelöste 2D Beispiel von biologischen und technischen Mikrostrukturen.
Modellrechnungen mit dem CT-Algorithmus DIRECTT (Direkte iterative Rekonstruktion computertomographischer Trajektorien) haben die Vorteile gegenüber anderen Ansätzen bezüglich Ortsauflösung und Dichte gezeigt, insbesondere auch für unvollständige Datensätze wie Limited View- und Region of Interest-Szenarien. Entsprechend dem Normalfall werden hier jedoch vollständige Datensätze von Modellen und Messungen und ihre Rekonstruktionen bewertet. Die Qualität von DIRECTT wird mit der Gefilterten Rückprojektion anhand der Modulations-Transfer-Funktion (MTF) sowie integraler Kenngrößen im Radon- und im Ortsraum verglichen. Zur Überprüfung der Rekonstruktionsgenauigkeit experimenteller Daten werden Mustermessungen einfacher Probengeometrien unter definierten physikalischen Bedingungen durchgeführt. Diese betreffen Monochromasie, Unterdrückung von Kantenartefakten und radiometrische Intensitätsbestimmung mit Einkanaldetektor.
A fiber Bragg grating (FBG) strain patch specially adapted for long-term and high-strain applications has been developed and characterized. The design concept for the patch is based on a glass-fiber reinforced plastic (gfrp) carrier material. The developed concept for the FBG integration into the carrier material was derived from reliable integration procedure of FBG sensors into composite structures. The patches' temperature sensitivity, strain gauge factor, fiber–matrix interface adhesion and fatigue behavior were characterized. As a result, FBG strain patches with linear temperature and strain behavior, as well as excellent fatigue resistance, were developed and can be used as part of a monitoring system for advanced composite materials in aerospace structures or wind turbine power plants.
Smart technical textiles are by definition textiles that can interact with their environment.
They can sense and react to environmental conditions and external stimuli from mechanical, thermal, chemical or other sources. Such textiles are multifunctional or even “intelligent” which is fulfilled by a number of sensors incorporated in the textiles. The embedded sensors are sensitive to various parameters such as temperature, strain, chemical, biological and other substances.
Aktuell wird die Ultraschallechotechnik für Holzbauteile genutzt, indem aus der Abschattung eines ansonsten stabilen Rückwandechos auf Auffälligkeiten im Holzbauteil geschlossen wird. Dabei werden Transversalwellen (Mittenfrequenz 50 kHz) mit der Polarisationsrichtung in Faserrichtung (L) angewendet. In einem 2012 abgeschlossenen Forschungsvorhaben wurde nun die direkte Abbildung von Streuern durch anisotrope SAFT-Rekonstruktion entwickelt.
Dazu werden flächig aufgenommene Ultraschallmessdaten mit automatisiert scannenden Druck- und Scherwellenköpfen erzeugt und auf Basis anisotroper Geschwindigkeitsverteilungen rekonstruiert. Benutzt werden die auch häufig für Beton eingesetzten trocken ankoppelnden Punktkontakt-Prüfköpfe. Da damit auch intensive Wellen an der Oberfläche erzeugt werden, entstehen im Material zusätzliche Kopfwellen, die ebenfalls bei der Rekonstruktion berücksichtigt werden.
Da die Wellengeschwindigkeiten in Holz individuell stark schwanken, wird eine interaktive Auswertetechnik zur Ermittlung der Materialkonstanten benutzt. Für die Messungen werden Druckwellen sowie Scherwellen in zwei Polarisationsrichtungen verwendet. Die Messungen erfolgen sowohl mit automatischen Scannersystemen als
auch mit einem linearen Prüfkopf-Array (kommerziell erhältlicher multistatischer Messkopf). Gezeigt werden Ergebnisse an Bauteilen mit künstlichen und realen Fehlstellen. Das Forschungsprojekt wurde gefördert vom Bundesamt für Bau- und Raumordnung (BBR, Zukunft Bau).
Zur Durchstrahlung großer, dichter Objekte reichen die Energien, die mit normalen Röntgenröhren erzielt werden können, ab gewissen Schichtdicken nicht mehr aus. Als hochenergetische Strahlenquellen stehen Kobalt-60 und Elektronenbeschleuniger zur Verfügung. Als Einschränkung der Hochenergieradiographie ist der geringere Kontrast besonders beim Vorhandensein leichterer Objekte umgeben von Körpern bestehend aus schweren Elementen anzusehen. Es ist daher zu erwarten, dass Objekte aus organischen Substanzen hinter dicken Schwermetallwänden oder in Bohrungen von Metallblöcken schwer zu erkennen sind. Im Gegensatz zu einem Gammastrahler wie Kobalt-60 mit den beiden Spektrallinien um 1,3 MeV besitzt die Bremsstrahlung aus einem Beschleuniger einen wesentlichen Anteil an niederenergetischer Strahlung, der fließend zu höheren Energien übergeht. Es wird hier untersucht, welche Signaturen von leichten Materialien in einer Umgebung aus Schwermetall bis zu welcher Dicke und bis zu welchem Komplexizitätsgrad erkennbar sind. Mit einem Betatron (JME X-ray Betatron 7,5 MeV) und einem Matrixdetektor (Perkin Elmer XRD 1621) wurden Aufnahmen von unterschiedlichen leichten Objekten angefertigt, die zunehmend in eine Umgebung aus Schwermetallen gestellt wurden. Mit unterschiedlichen Energieeinstellungen wurde untersucht, inwieweit eine Materialerkennung hinter welcher Abschirmung möglich ist. Die experimentellen Ergebnisse werden mit Simulationen verglichen, die mit einer Software zur Modellierung von Durchstrahlungsverfahren (aRTist) erzeugt wurden. Dabei wird dem Problem der Aufhärtung bei Anwendung von Bremsstrahlung Rechnung getragen. Die Ergebnisse können sowohl zur Erkennung von Fremdkörpern in Maschinen oder Pumpen als auch zur Überprüfung von Frachtladungen im Bereich der öffentlichen Sicherheit und bei Zollkontrollen dienen.
Ultrasonic echo and transmission techniques are used in civil engineering on a regular basis. New sensors and data processing techniques have lead to many new applications in the structural investigation as well as quality control. But concrete structures in the nuclear sector have special features and parameters, which pose problems for the methods and instrumentation currently available, e.g. extreme thickness, dense reinforcement, steel liners or special materials. Several innovative ultrasonic techniques have been developed to deal with these issues at least partly in lab experiments and pilot studies. Modern imaging techniques as multi-offset SAFT have been used e. g. to map delaminations. Thick concrete walls have successfully been inspected, partly through a steel liner. Embedded ultrasonic sensors have been designed which will be used in monitoring networks of large concrete structures above and below ground. In addition, sensitive mathematical methods as coda wave interferometry have been successfully evaluated to detect subtle changes in material properties. Examples of measurements and data evaluation are presented.
A major requirement for the validation of methods assessing the risk associated with engineered nanoparticles (ENPs) is the use of reference materials (RMs). In the present contribution we review available RMs, ongoing projects and characterisation trends in the field. The conclusion is that actual approaches to RMs mostly deal with metrological considerations about single properties of the ENPs, typically their primary size, which can hardly be representative of nanoparticles characteristics in real testing media and therefore, not valid for reliable and comparable toxicological studies. As an alternative, we discussed the convenience and feasibility of establishing multi-parametric RMs for a series of ENPs, focusing on silica nanoparticles (SNPs). As a future perspective, the need to develop RMs based on hybrid nanoparticles is also discussed.
Das Monitoring von Bauteilen bei Ermüdungsbelastung mit Hilfe der Schallemission liefert eine große Anzahl an Schallemissionsdaten und –parametern. Um diese in einen Zusammenhang mit dem Schadenszustand des Bauteils zu bringen ist es sinnvoll, einen Bezug zu bekannten bruchmechanischen Kenngrößen herzustellen. Dies wird in dieser Arbeit anhand von Ermüdungsversuchen an Platten aus dem Feinkornstahl P460NL1 versucht. Schallemissionssignale aus Ermüdungsrissen mit und ohne Korrosionseinfluss werden analysiert und mit bekannten bruchmechanischen Kenngrößen wie der Risswachstumsrate und dem Spannungsintensitätsfaktor verglichen.
Thermografische ZfP-Verfahren erlauben die Erkennung einer Vielzahl von Defekten in unterschiedlichsten Werkstoffen. Neue Ansätze unter Verwendung von Lasern ermöglichen darüber hinaus die Prüfung auf Oberflächenrisse. Wir stellen die neuesten Entwicklungen dieser vielversprechenden Technik vor und zeigen warum deren Einsatz potentiell die Standardprüfverfahren Magnetpulver- bzw. Eindringprüfung für eine Reihe von Prüfproblemen beerben könnte. Hierzu stellen wir die Prüfergebnisse zu unterschiedlichen metallischen Werkstoffen, Rissgrößen und -typen in Abhängigkeit der Prüfparameter vor. Die aktuelle Grenze der Nachweisempfindlichkeit für die mittels klassischer Thermografie schwer prüfbaren hochreflektierenden Metalloberflächen liegt mit Rissbreiten und -tiefen von weni-gen Mikrometern im Bereich der fluoreszierenden Magnetpulver- und Eindringprüfung. Dabei sind weder Verbrauchsmittel noch eine Oberflächenpräparation notwendig und eine Prüfung kann berührungslos und automatisiert über Entfernungen im Meter-Bereich erfolgen.
Indirect UV-absorption spectrometry was shown to be a valuable tool for chemical characterization of functionalized carbon nanotubes (CNTs). It complements data from X-ray photoelectron spectroscopy (XPS) or FTIR analysis since it helps to clarify the type and concentration of functional groups. The principles of indirect application of UV-spectrometry and its mathematical interpretation are discussed. Their facile application, together with their adequate sensitivity and high flexibility, make UV-absorption-based approaches a valuable alternative to fluorescence spectrometry. Here, the approach was applied to the chemical analysis of oxidizing substances on CNTs. For this, pristine CNTs of low but finite oxygen content as well as brominated CNTs were analyzed by reaction in suspension with UV-active thiol reagents and a styrene derivative. It was shown that carefully selected reagents allow differentiation and quantification of bromine and generally oxidizing entities like oxygen. For brominated CNTs, it was shown that physisorbed bromine may dominate the overall bromine content.
Carbon capture & storage (CCS) is one of the most promising technologies for greenhouse gas (GHG) management. However, an unsolved issue of CCS is the development of appropriate long-term monitoring systems for leak detection of the stored CO2. To complement already existing monitoring infrastructure for CO2 storage areas, and to increase the granularity of gas concentration measurements, a quickly deployable, mobile measurement device is needed. In this paper, we present an autonomous gas-sensitive micro-drone, which can be used to monitor GHG emissions, more specifically, CO2. Two different measurement strategies are proposed to address this task. First, the use of predefined sensing trajectories is evaluated for the task of gas distribution mapping using the micro-drone. Alternatively, we present an adaptive strategy, which suggests sampling points based on an artificial potential field (APF). The results of real-world experiments demonstrate the feasibility of using gas-sensitive micro-drones for GHG monitoring missions. Thus, we suggest a multi-layered surveillance system for CO2 storage areas.
In einer speziellen 3D-Prüfanlage zur wirklichkeitsnahen Simulation von komplexen Verhältnissen an Großproben wurden UP-Mehrlagenschweißungen am warmfesten Stahl 13CrMoV9-10 durchgeführt. Während der schweißtechnischen Fertigung und der Abkühlung auf Raumtemperatur wurden die Proben an der freien Ausdehnung und Schrumpfung gehindert. Die daraus resultierenden Reaktionsspannungen führten während der Wärmenachbehandlung zu Relaxationsrissen in der Wärmeeinflusszone. Das Spannungsarmglühen wurde bei einer Temperatur von 705°C und einer Haltezeit von 8 h durchgeführt. Während der Aufheiz- und Abkühlphasen wurde die thermische Ausdehnung der Probe über die 3D-Prüfanlage kompensiert und damit das Spannungsniveau bis zum Erreichen der maximalen Glühtemperatur aufrechterhalten. Nach Erreichen der Glühtemperatur konnte die Probe relaxieren. Der Einsatz der Schallemissionsmessung ermöglichte es die Entstehung von Spannungsrelaxationsrisse, erstmalig online, nachzuweisen. Durch Synchronisierung der Schallemissionsereignisse mit den Messdaten der 3D – Prüfanlage wurde der kritische Temperaturbereich für das Auftreten von Spannungsrelaxationsrissen bestimmt. Die Rissinitiierung findet im Temperaturbereich zwischen 350°C - 500°C statt. Aussagen über das Risswachstum können auf Grund der ungünstigen Versuchsbedingungen, mit Emission von Störgeräuchen, nicht getroffen werden.
Luminescence techniques are among the most widely used detection methods in the life and material sciences. At the core of these methods is an ever-increasing variety of fluorescent reporters (i.e., simple dyes, fluorescent labels, probes, sensors and switches) from different fluorophore classes ranging from small organic dyes and metal ion complexes, quantum dots and upconversion nanocrystals to differently sized fluorophore-doped or fluorophore-labeled polymeric particles. A key parameter for fluorophore comparison is the fluorescence quantum yield (Φf), which is the direct measure for the efficiency of the conversion of absorbed light into emitted light. In this protocol, we describe procedures for relative and absolute determinations of Φf values of fluorophores in transparent solution using optical methods, and we address typical sources of uncertainty and fluorophore class-specific challenges. For relative determinations of Φf, the sample is analyzed using a conventional fluorescence spectrometer. For absolute determinations of Φf, a calibrated stand-alone integrating sphere setup is used. To reduce standard-related uncertainties for relative measurements, we introduce a series of eight candidate quantum yield standards for the wavelength region of ~350950 nm, which we have assessed with commercial and custom-designed instrumentation. With these protocols and standards, uncertainties of 5–10% can be achieved within 2 h.
Für die optische Erwärmung von Prüfteiloberflächen sind Blitz- und Halogenlampen Stand der Technik. Der Vorteil dieser Wärmequellen liegt in ihren relativ geringen Anschaffungskosten bei gleichzeitig hohen Leistungsdichten am Prüfobjekt. Nachteilig ist bei den Halogenlampen die Limitierung der möglichen Modulationsffequenz auf ca. 1 Hz für die Anwendung dieser Quelle in der Lockin-Thermografie. Blitzlampen bieten für gewöhnlich nur eine feste Blitzdauer bei einer geringen Taktrate. Beide Anregungsquellen müssen in Reflexionsanordnung mit Filtern betrieben werden um die entstehende thermische Eigenstrahlung als Störquelle zu eliminieren. Wir stellen Untersuchungen an Hochleistungs-LEDs für den Einsatz in der aktiven Thermografie vor. Diese Lichtquellen werden durch die rasante Entwicklung der möglichen Leistungsdichten nun auch für die thermografische ZfP interessant. Sie zeigen ähnlich dem Laser eine schmale und auf den Werkstoff abstimmbare spektrale Verteilung der Strahlungsleistung bei moderaten Kosten. Die zugrunde liegende Elektrolumineszenz generiert kaum Wärmestrahlung und ermöglicht dadurch die Prüfung während des Erwärmungsvorganges ohne größeren Aufwand. Modulationsfrequenzen über 100 Hz mit thermischen Eindringtiefen < 1 mm sind möglich. Dadurch qualifizieren sich die LEDs zur Anwendung in der Lockin-Thermografie von Metallen und zur oberflächennahen Prüfung von Schichtsystemen. Durch die fast verzögerungsffeie Reaktion der LED auf das steuernde Signal sind nahezu beliebige zeitliche Anregungsformen möglich. Mit solch flexiblen Anregungsformen ließen sich bereits bei den photothermischen Verfahren erfolgreich höhere Tiefenreichweiten und -auflösungen gegenüber den klassischen Methoden der monofrequenten Lockin - und energiereichen Kurzimpuls-Anregung erzielen. Untersuchungen dieser Möglichkeiten im praktischen Einsatz der HochleistungsLEDs werden vorgestellt und mit herkömmlichen Lichtquellen verglichen.
Eines der bedeutendsten Kunstwerke des Magdeburger Doms sind die Putzritzungen am Ostflügel des Kreuzgangs aus dem 13. Jahrhundert. Der größte Teil der einzelnen Putzoberflächen sind Ausbesserungen oder Neuverputzungen aus verschiedenen Restaurierungs- oder Reparaturphasen. In dem von der Forschungsinitiative Zukunft Bau geförderten Projekt zur 3D-Kartierung von Bauwerksoberflächen wurden Untersuchungen zur Erfassung der Schäden an diesen Putzritzungen mit optischen 3D-Messverfahren und der aktiven Thermografie durchgeführt. Dabei wurden bei den optischen Verfahren hochauflösende Techniken zur Erfassung der Oberflächentopologie (Stereophotogrammmetrie) und zur Vermessung der Rissstrukturen und Ausbeulungen (3D-Trackingverfahren) eingesetzt. Die Zuordnung der Signaturen in den Thermogrammen zu Hohlstellen sowie Materialergänzungen und -ersatz wird diskutiert. Weiterhin erfolgt ein Vergleich der Ergebnisse mit Messungen an neu freigelegten Putzbereichen.
Anhand eines erfolgreichen Messeinsatzes an einer Spannbetonbrücke, deren Querspannglieder zuverlässig lokalisiert und nachfolgend instandgesetzt werden sollen, wird die Vorgehensweise der Radarmessung mit zwei verschiedenen Polarisationsrichtungen der Antenne zur Unterscheidung von unterschiedlichen Arten der Bewehrungen ausführlich erklärt. Das Radarverfahren eignet sich sehr gut für die zerstörungsfreie Ortung von Bewehrung in Stahlbetonbauwerken. Insbesondere lässt sich mit dem Verfahren vorgespannte Bewehrung bis in einer Tiefe von ca. 30 cm und bei einem normalen Bewehrungsgrad (Maschenweite >10 cm) der schlaffen Bewehrung zuverlässig auffinden. Seit einigen Jahren wird das Radarverfahren erfolgreich im Vorfeld einer schadensfreien Kernbohrung im Rahmen von Ertüchtigungsmaßnahmen von Stahlbetonbrücken mit externen Spanngliedern angewendet. Aufgrund der Lage und dem Verlauf der vorgespannten Bewehrung in Hohlkastenseitenwänden und Plattenbalken kann eine vorgespannte Bewehrung von schlaffer Bewehrung in diesen Bauwerken sehr gut unterschieden werden. Diese Unterscheidungsmerkmale lassen sich aber bei Querspanngliedern in einer Fahrbahnplatte nur selten anwenden, da häufig die Überdeckung und der Abstand der schlaffen Bewehrung und der Querspannglieder ähnlich sind. In diesem Beitrag wird beschrieben, wie der gezielte Einsatz verschiedener Polarisationsrichtungen der Antenne zu einer zuverlässigen Unterscheidung von schlaffer Bewehrung und Spanngliedern beiträgt und damit zu einer verbesserten bildgebenden Darstellung der inneren Konstruktion der Fahrbahnplatte führt.
Für Ultraschallmessungen in Betonbauteilen wurden neuartige radialsymmetrisch abstrahlende Longitudinalwellenprüfköpfe mit einer Mittenfrequenz von 60 kHz auf deren Eignung hinsichtlich Abstrahlcharakteristik, Empfindlichkeit und Frequenzspektrum untersucht.
Für die Messung der Abstrahlcharakteristiken wurden die Prüfköpfe vertikal und horizontal in Betonzylinder eingebettet und die Richtungsabhängigkeiten der Schallschnelle mithilfe eines Laservibrometers gemessen.
Die Streuung der Prüfkopfempfindlichkeit wurde im Wasserbad unter Verwendung verschiedener Köpfe gleicher Bauart bestimmt. Außer Änderungen der Signalamplituden zeigten sich auch Schwankungen im Frequenzbereich bei verschiedenen Sender-Empfängerkombinationen.
Die Schallschwächung des Betons hat Einfluss auf die erreichbare Auflösung der Messungen und damit auf die maximal möglichen Senderabstände im Bauteil. Durch experimentelle Untersuchungen und Simulationen erfolgte eine Optimierung der Abstände hinsichtlich des Aufwandes und der geforderten Auflösung. Die Signalschwächung im Beton wurde mit verschiedenen Impulsen im Frequenzbereich von 50 kHz bis 100 kHz in Abhängigkeit verschiedener Bewehrungsgrade und Korngrößen ermittelt. Hierfür wurden die Sensoren in unterschiedlichen Abständen in die Probekörper einbetoniert und die Empfangssignale hinsichtlich Amplitudenabfall und Frequenzspektrum untersucht.
POD is the most often used approach for the evaluation of the reliability of non-destructive testing methods in critical areas. But especially for those cases the requirements for a sufficient amount of data, adequate type of defects and the statistical requirements are high. The claim for checking these requirements is not new, but never the less often ignored. Especially the large amount of data for critical real defects seems too often to be not really solvable. In this presentation we show an approach to use real defect data with knowledge from former testing results with the same equipment, in a useful adequate way. Furthermore we introduce a method to evaluate the real defect description parameters for the radiographic testing. This approach was used for a joint project with the company POSIVA, which is building a final depository for spent nuclear fuel in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam weld of the copper canister. The copper canister will be used in the deposit as a corrosion barrier within the deposit concept. Through the high sophisticated manufacturing methods of the canister there are almost no material defects, which could be used for reliability evaluation. In this context the idea of Bayesian Updating of the POD with real defect data with former results from artificial defect data was born to get a useful evaluation.
Using the Modular Reliability Model the three different main influencing elements, i.e. intrinsic capability (IC), application parameters (AP) and the human factors (HF), are, in the first instance, investigated separately. The intrinsic capability stands for the pure physical-technological process of the signal detection caused by the waves or the rays from a material defect in the presence of noise (driven by the material and the devices). This intrinsic capability is the upper bound of the possible reliability. Already when measuring this intrinsic capability for thick walled components the original one-parameter POD must be extended to a multiparameter POD, where, in addition to the defect size, a number of additional physical parameters, such as the grain size distribution (or attenuation), defect depth, and angle or surface roughness, must be considered. For real life cycle assessments it is necessary to evaluate the signal response from real defects. The industrial application factors, e.g. coupling conditions, limited accessibility, heat and environmental vibrations, diminish the reliability. The amount of reduction can be determined quantitatively, if the underlying conditions are controlled. In case they are not controlled it is necessary to count for a fluctuation in the reliability in the field anyway. The third group of important influencing factors are the human factors, which do not only cover the individual performance capability of the inspectors but also the design of the working place,the procedure, the teamwork quality, interaction with systems, the organization, and finally, the relationship between the companies involved in the inspection process and to which extend the responsible parties are aware of it. When comparing an “ideal inspection” with a “real inspection” it is worth while to look how the existing practices, rules and standards support reliable testing and where the “delta” is. In the context of vigor, with respect to the industrial end user, it needs to be shown how the level of reliability of NDE, influenced by the different factors, has an impact on acceptance or rejection of safety critical parts.
Quantifying degradation of collagen in ancient manuscripts: the case of the Dead Sea Temple Scroll
(2013)
Since their discovery in the late 1940s, the Dead Sea Scrolls, some 900 ancient Jewish texts, have never stopped attracting the attention of scholars and the broad public alike, because they were created towards the end of the Second Temple period and the 'time of Christ'. Most of the work on them has been dedicated to the information contained in the scrolls' text, leaving physical aspects of the writing materials unexamined. They are, however, crucial for both historical insight and preservation of the scrolls. Although scientific analysis requires handling, it is essential to establish the state of degradation of these valued documents. Polarized Raman Spectroscopy (PRS) is a powerful tool for obtaining information on both the composition and the level of disorder of molecular units. In this study, we developed a non-invasive and non-destructive methodology that allows a quantification of the disorder (that can be related to the degradation) of protein molecular units in collagen fibers. Not restricted to collagen, this method can be applied also to other protein-based fibrous materials such as ancient silk, wool or hair. We used PRS to quantify the degradation of the collagen fibers in a number of fragments of the Temple Scroll (11Q19a). We found that collagen fibers degrade heterogeneously, with the ones on the surface more degraded than those in the core.
Standardisierung der Lockin-Thermografie: Vorstellung des TNS-Projektes und Auswahl der Probekörper
(2013)
Ziel des Verbundprojektes zwischen der BAM und dem IKT der Universität Stuttgart ist die Festlegung einer einheitlichen Vorgehensweise für die Auswahl der Gerätekomponenten und für die Durchführung von Prüfungen mit der Lockin-Thermografie. Daraus soll ein Standard abgeleitet werden, der die Prüfung
unterschiedlicher Materialsysteme auf Fehlstellen mittels Lockin-Thermografie unter Berücksichtigung verschiedener Anregungsquellen ermöglicht. In diesem Beitrag wird die Entwicklung der Probekörper vorgestellt, die in diesem Projekt untersucht und später als Referenzprobekörper verwendet werden können.
Die Synthetic Aperture Focusing Technique (SAFT) ist ein Verfahren zur Verarbeitung von HF-Bildern, die an unterschiedlichen Prüfkopfpositionen aufgenommen wurden. Es wird in der zerstörungsfreien Werkstoffprüfung genutzt, um eine Abbildung von Materialfehlern innerhalb des Gebietes zu erstellen, auf das die Rekonstruktion angewandt wird. Die nach Abschluss der SAFT-Rekonstruktion zusammengestellten Informationen über Reflektoren liegen zunächst nach wie vor in Form von HF-Daten vor. Die Interpretierbarkeit der SAFT-Bilder ist im Allgemeinen davon abhängig, wie diese Daten vor der endgültigen Darstellung aufbereitet werden. Die Bildung der Amplitudeneinhüllenden aus dem zugehörigen analytischen Signal stellt eine Möglichkeit einer solchen Aufbereitung nach Anwendung des SAFT-Algorithmus dar. Sie ist jedoch nur im eindimensionalen Fall eindeutig definiert. In diesem Beitrag wird das Konzept der analytischen Signale mit single-orthant-Spektren aufgegriffen, um eine Detektion der Einhüllenden an mehrdimensionalen HF-Daten durchzuführen. Dabei wird über die Betragsquadrate aller möglichen nach dieser Definition zu bildenden analytischen Signale gemittelt. Es wird gezeigt, dass die Anwendung des beschriebenen Verfahrens einem Separationsansatz entspricht. Außerdem wird eine Möglichkeit aufgezeigt die Gültigkeit dieses Ansatzes anhand der totalen und partiellen Hilberttransformationen des Signals im konkreten Fall zu überprüfen. Die Ergebnisse dieser Methode zur Verbesserung von SAFT Bildern werden unter Verwendung synthetischer und experimenteller Daten an rekonstruierten Abbildungen verschiedener Reflektorarten beispielhaft dargestellt.
Separation of CO2. Microporous polyurethane networks were prepared based on a renewable resource. Betulin, extracted from birch bark, is used as a structure-directing diol monomer in A3-B2 monomers. The resulting microporous networks show very promising CO2/N2 selectivities. The state of adsorbed CO2 is analyzed by in situ NMR spectroscopy, and pure physisorption is proven. The preparation of monolithic materials is demonstrated as well.
In welding experiments conducted on heavy wall pipes, the penetration mode (full or partial penetration) occurred to be a significant factor influencing appearance of solidification cracks. To explain the observed phenomena and support further optimization of manufacturing processes, a computational model was developed, which used a sophisticated strategy to model the material. High stresses emerged in the models in regions which showed cracking during experiments. In partial penetration welding, they were caused by the prevention of weld shrinkage due to the cold and strong material below the joint. Another identified factor having an influence on high stress localization is bulging of the weld.
PLR Prüftechnik Linke & Rühe Magdeburg und die BAM Bundesanstalt für Materialforschung und -prüfung Berlin haben in Zusammenarbeit mit anderen Partnern im Laufe der letzten Jahre verschiedene Wirbelstromsysteme zur Prüfung verlegter Schienen auf rissartige Fehler des Typs Head Checks entwickelt. Die Entwicklung dieser Systeme erfolgte mit dem Ziel, ein Hilfsmittel für die Planung von Schieneninstandhaltungsmaßnahmen zu schaffen. Die Systeme haben sich im praktischen Prüfeinsatz bewährt. Hierzu wurde regelmäßig auf den vorhergehenden Tagungen berichtet. Bei der Schieneninstandhaltung kommen unterschiedliche Typen von Schienenbearbeitungsmaschinen zum Einsatz, z. B. Schienenfräs- und Schleifzüge. Seit einiger Zeit wird von Seiten der Schienennetzbetreiber vermehrt ein Qualitätsnachweis nach erfolgter Schienenbearbeitung gefordert. Hierzu wurde ein Wirbelstromprüfsystem entwickelt, dass speziell an die Erfordernisse der Qualitätsüberwachung in Schienenbearbeitungsmaschinen angepasst ist. Das Prüfsystem wird vorgestellt und über erste Erfahrungen aus dem praktischen Einsatz wird berichtet.
Häufig müssen rotierende metallische Bauteile im Betrieb auf das Entstehen rissartiger Fehler überwacht werden. Hierbei besteht im Allgemeinen die Anforderung, trotz extrem schwieriger Umweltbedingungen eine sichere Prüfaussage zu gewährleisten. Es wurden Untersuchungen durchgeführt, inwieweit passive induktive Sensoren in der Lage sind, diese Anforderungen zu erfüllen. Hierzu wurden verschiedene einfache Sensormodelle aufgebaut und an verschiedenen Vergleichsfehlern erprobt. Die Ergebnisse der Untersuchungen werden vorgestellt. Insbesondere die Möglichkeiten und Grenzen dieser einfachen Sensortypen werden herausgearbeitet.
Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Algal blooms are a frequent phenomenon in nearly all kinds of fresh water. Global warming and eutrophication by waste water, air pollution and fertilizers seem to lead to an increased frequency of occurrence. Many cyanobacteria produce hazardous and quite persistent toxins, which can contaminate the respective water bodies. This may limit the use of the raw water for many purposes. The purification of the contaminated water might be quite costly, which makes a continuous and large scale treatment economically unfeasible in many cases. Due to the obvious risks of algal toxins, an online or mobile detection method would be highly desirable. Several biosensor systems have been presented in the literature for this purpose. In this review, their mode of operation, performance and general suitability for the intended purpose will be described and critically discussed. Finally, an outlook on current developments and future prospects will be given.
This survey will discuss current and emerging isothermal and rapid polymerase chain reaction (PCR) based nucleic acid amplification methods for patient near diagnostics. To assess the clinical need of rapid diagnostics for infectious diseases based on nucleic acid tests (NATs) we performed and analysed a questionnaire among laboratories participating in corresponding INSTAND ring trials for external quality assurance. The questions concerning new amplification technologies like isothermal nucleic acid amplification, potentially suited to significantly decrease turnaround times, were complemented by questions to evaluate the present status of NATs. Besides end-users, companies were also addressed by sending out a manufacturer specific questionnaire. Analysis of the answers from 48 laboratories in 14 European countries revealed that a much shorter turnaround time is requested for selected pathogens compared to about 2 h or longer when applying temperature cycling amplification, i.e. PCR. In this context, most frequently mentioned were MRSA, norovirus, influenza A and B viruses, cytomegalovirus (CMV) as well as hepatitis B virus (HBV) and hepatitis C virus (HCV). At present, 8% of the laboratories having participated in this survey apply isothermal amplification of nucleic acid to identify infectious pathogens.
Über die Entwicklung von Anwendungsregeln für reaktive Brandschutzsysteme auf Stahlzuggliedern
(2014)
Der vorliegende Beitrag stellt den Entwicklungsstand von Anwendungsregeln für reaktive Brandschutzsysteme auf Stahlzuggliedern zusammenfassend dar. Dabei wird insbesondere auf die jüngsten Veränderungen in den normativen Grundlagen und bauaufsichtlichen Regelungen eingegangen und im Hinblick auf Sicherheitsaspekte bewertet.
Die Verringerung der Teilsicherheit für den Bauteilwiderstand nicht stabilitätsgefährdeter Bauteile im Regelwerk für die Kaltbemessung von Stahltragwerken ist hier als besonders kritisch anzusehen, da hierdurch ein systematisches Sicherheitsdefizit für den Brandfall verursacht wird.
Weiterhin werden neuste Forschungsergebnisse bei der Entwicklung von Bewertungsregeln von reaktiven Brandschutzsystemen auf Vollkreisprofilen unter Zugbeanspruchung vorgestellt und diskutiert. Die Untersuchungen behandeln die Fragestellung, inwieweit Prüfungen mit Zugbeanspruchungen an Kreisvollprofilen erforderlich sein werden.
Sollten CT Aufnahmen quantitativ und automatisch ausgewertet werden, ist die Qualität der Tomogramme ein wesentlicher Punkt. Außerdem steht bei Serienmessungen nur eine begrenzte Meßzeit für jede Probe. Es werden die verschiedenen Mikrofokusröhren in Bezug auf die Parameter Orts- und Dichteauflösung, sowie Meßzeit verglichen, CT Beispiele dazu gezeigt.
The synthesis of the polymorphic cocrystal caffeine:anthranilic acid was investigated to obtain a better understanding of the processes leading to the formation of different polymorphic forms. In the case of these cocrystal polymorphs synthesized by liquid-assisted grinding a distinct influence of the dipole moment of the solvent was found. A pre-coordination between the solvent molecules and the caffeine:anthranilic acid cocrystal could be identified in the formation of form II. In the case of form II the solvent can be regarded as a catalyst. The formation pathway of each polymorph was evaluated using synchrotron X-ray diffraction.
Fourier-Spektroskopische Untersuchungen von hochmolekularem Polyethylen (HMW-PE) und ultrahochmolekularem Polyethylen (UHMW-PE) im Mittleren - und Fernen Infrarotbereich können Veränderungen der molekularen Strukturen nachweisen, die durch Co60 γ-Strahlung und Rekristallisationsprozesse initiiert werden. UHMW-PE und HMW-PE sind im gewählten IR-Bereich unterscheidbar. Die integrale Absorption der B1u – Gitterschwingungen im Fernen Infrarotbereich (THz-Bereich) ermöglichen die quantitative Beschreibung des Kristallinitätsgrades und dessen Abbau. Die Bildung ungesättigter Vinylengruppen und der Abbau ungesättigter Methylengruppen können im Mittleren Infrarotbereich nachgewiesen werden.
Geführte Ultraschallwellen bieten eine Vielzahl von Einsatzmöglichkeiten in der Zerstörungsfreien Prüfung, der Zustandsüberwachung sowie der Materialcharakterisierung. Insbesondere für Rohrleitungen und ausgedehnte Plattenstrukturen ist eine Vielzahl von auf geführten Wellen basierenden Verfahren in der Entwicklung und teilweise bereits im Einsatz. Aufgrund des komplexen Ausbreitungsverhaltens geführter Wellen werden numerische Verfahren (etwa die Finite Elemente Methode (FEM) oder die Randelementemethode (BEM)) zur Simulation der Wellenausbreitung sowie der Wechselwirkung mit Defekten in Wellenleitern angewendet. Diese Methoden sind für große Strukturen extrem rechenintensiv und umständlich in der Anwendung. Ein ungleich effizienteres Verfahren wurde kürzlich von den Autoren auf Grundlage der Scaled Boundary Finite Element Method entwickelt. Ein semi-analytischer Ansatz erlaubt die Modellierung beliebig ausgedehnter Strukturen bei extrem kurzen Rechenzeiten. Die Wechselwirkung geführter Wellen mit Rissen kann auf besonders elegante und exakte Weise beschrieben werden. Mit dieser Methode können die komplexen Vorgänge in Wellenleitern innerhalb weniger Sekunden modelliert werden.