Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (2095)
- Beitrag zu einem Tagungsband (388)
- Forschungsbericht (19)
- Beitrag zu einem Sammelband (10)
- Buchkapitel (9)
- Sonstiges (7)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Corrigendum (2)
- Dissertation (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (2297)
- Deutsch (233)
- Mehrsprachig (3)
- Portugiesisch (1)
Schlagworte
- Additive manufacturing (69)
- Fluorescence (56)
- Nanoparticles (48)
- Concrete (46)
- SAXS (46)
- Ultrasound (38)
- Corrosion (37)
- MALDI-TOF MS (37)
- Quantum yield (36)
- Non-destructive testing (34)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (450)
- 6 Materialchemie (447)
- 1 Analytische Chemie; Referenzmaterialien (358)
- 7 Bauwerkssicherheit (232)
- 5 Werkstofftechnik (218)
- 9 Komponentensicherheit (216)
- 4 Material und Umwelt (198)
- 6.3 Strukturanalytik (172)
- 8.5 Röntgenbildgebung (139)
- 6.1 Oberflächen- und Dünnschichtanalyse (102)
Paper des Monats
- ja (72)
Bei der Abschätzung der Beständigkeit von Kunststoffen gegenüber niedermolekularen Flüssigkeiten ist die Kohäsionsenergiedichte CED ein wichtiger Parameter auf molekularer Ebene. Die Vernetzungsdichte ν eines polymeren Festkörpers bildet hierbei einen bedeutsamen Kennwert, der darüber hinaus neben der Löslichkeit wichtige Eigenschaften wie thermische Stabilität und Steifigkeit des Materials charakterisiert. Für die experimentelle Bestimmung von CED und ν eignet sich die Untersuchung des Quellverhaltens in unterschiedlichen Lösungsmitteln. Es werden zwei Messmethoden miteinander verglichen und die Ergebnisse unter Berücksichtigung des molekularen Aufbaus von Proben aus Polyurethan (PU) und hochmolekularem – (HMWPE) und ultrahochmolekularem Polyethylen (UHMWPE) diskutiert. Zum Verständnis des Quellverhaltens dieser Polymerproben in niedermolekularen Lösungsmitteln werden neben den Messergebnissen Literaturdaten zu Grunde gelegt.
Ergopeptides, like ergocornine and a-ergocryptine, exist in an S- and in an R-configuration. Kinetic experiments imply that certain configurations are preferred depending on the solvent. The experimental methods are explained in this article. Furthermore, computational methods are used to understand this configurational preference. Standard quantum chemical methods can predict the favored configurations by using minimum energy calculations on the potential energy landscape. However, the explicit role of the solvent is not revealed by this type of methods. In order to better understand its influence, classical mechanical molecular simulations are applied. It appears from our research that 'folding' the ergopeptide molecules into an intermediate state (between the S- and the R-configuration) is mechanically hindered for the preferred configurations.
Innovative X-ray backscatter technique for security applications: Detection of dangerous materials
(2014)
Radiological inspections, in general, are NDT&E methods to detect the bulk of explosives without invasion into the object of analysis. In contrast to personal luggage, cargo or structural components constitute a complexity that may significantly hamper the detection of a threat by conventional transmission radiography. A novel approach of interrogating a large object to a certain depth only with a single sided access will be presented. It consists of an X-ray backscatter camera with a special twisted slit collimator for imaging backscattered objects. The new X-ray backscatter camera is not only imaging the objects due to their densities but also by taking into account the influences of surrounding objects. Additionally, it does not only image illuminated features but also depicts shadows from absorbing materials. This is a unique characteristic of the developed X-ray backscatter camera. Experimental mock-ups are conducted imitating container with threats among a complex packing as they may be encountered in reality. At the end, the significant advantages of the presented X-ray backscatter camera in the context of aviation and port security will be discussed.
Safe industrial operation is expected by the public. It contributes to a clean environment, innovation and prosperity. BAM the Federal German Institute for Materials Research and Testing has its responsibility in further developing safety in technology and chemistry by research, testing and expert advice. The basic reasoning for this activity and examples of current work are provided. Particular attention is given to the unique BAM Test site Technical Safety. Acceptance of fi ndings and transfer of results are based on collaboration and exchange of personal. Modes of cooperation are described.
Quantitative determination of acidic surface sites is highly important for the characterization of solid acids because the activity of a catalyst is often related to the concentration of these sites. A recently developed method using 15N Nuclear Magnetic Resonance spectroscopy (NMR) for the quantification of acidic Lewis and Brønsted sites has been tested for a series of nanoscopic aluminum hydroxide fluorides. Comparison with other methods for the quantitative determination of acidic sites shows that this 15N NMR quantification method is a promising technique for the comprehensive investigation of acidic sites. Three different acidic sites, one Brønsted and two Lewis sites, can be distinguished by their 15N chemical shifts of pyridine and simultaneously quantified under conditions corresponding to catalytic reaction conditions. Determination of the individual concentrations of acidic sites allows further insight into the catalytic process. It was found that the concentration of Brønsted sites correlates with catalyzed conversion of citronellal to isopulegol in the investigated series of catalysts. Additionally, investigations indicate that one of the Lewis sites become blocked during the reaction of citronellal.
Time reversal techniques are used in ocean acoustics, medical imaging and non-destructive evaluation to backpropagate recorded signals to the source of origin. We demonstrate experimentally a technique which improves the temporal focus achieved at the source location. The experiment consists of propagating a signal from a transducer within a concrete block to a single receiver on the surface, and then applying time reversal or deconvolution to focus the energy back at the source location. The results show that we are able to generate a focus in time at the correct location. The proposed method is simple and proven to be robust. Additionally, its costs are negligible due to deconvolution being a preprocessing step to the recorded data. The technique can be applied for detailed investigation of the source mechanisms (e. g. cracks) but also for monitoring purposes.
Ultraschallverfahren haben sich im Bauwesen in den letzten Jahren immer mehr in der Praxis etabliert. Echomessungen zur Geometriebestimmung sind Stand der Technik. In der Wissenschaft gibt es zahlreiche Ideen, die Messmethodik und die Auswertung weiter zu verbessern sowie den Einsatzbereich zu erweitern. Erste eingebettete Ultraschallsysteme zum Langzeitmonitoring sind installiert, Mehrkanalgeräte ermöglichen immer größere Aperturen und Eindringtiefen, verbesserte Abbildungsverfahren zeigen immer mehr Details. Zusätzlich lassen sich Verfahren aus der Geophysik adaptieren, die weiteren Fortschritt versprechen. Die Seismische Interferometrie dient klassisch dazu, Materialeigenschaften des Erduntergrundes mittels seismischer Wellen zu bestimmen. Derzeitige Anwendungsbereiche sind die Verbesserung seismischer Abbildungsverfahren, Interpolation seismischer Spuren (A-Scans), Bestimmung von Quellparametern oder die Eliminierung unerwünschter Signale in passiven und aktiven Experimenten, hauptsächlich durch Kreuzkorrelation und Bestimmung Greenscher Funktionen. Diese Techniken können auch auf Ultraschalldaten, die an Betonkonstruktionen erfasst wurden, angewendet werden. Moderne Abbildungsverfahren benötigen eine möglichst hohe A-Scan-Dichte und eine genaue Kenntnis des Quellsignals. Beides ist nicht unbedingt gegeben, z. B. wegen der physischen Größe der Sensoren und wechselnder Ankopplungsbedingungen. In simulierten und realen Experimenten wurden interferometrische Methoden zur Lösung dieser Aufgabenstellungen evaluiert. Es zeigt sich, dass fehlende A-Scans kinematisch korrekt interpoliert werden können, wenn ausreichend viele Sender- und Empfängerpositionen genutzt wurden. Amplituden und Signalform sind verändert, können aber durch adaptive Filterung angepasst werden. Die Quellsignalform kann mit hoher Genauigkeit rekonstruiert werden. Die Ergebnisse können potentiell zu einer Verbesserung der Abbildung des Inneren der untersuchten Objekte genutzt werden.
The EU FP7 NanoDefine project was launched in November 2013 and will run until October 2017. The Project is dedicated to support the implementation of the EU Recommendation on the Definition of Nanomaterial
by the provision of the required analytical tools and respective guidance. Main goal is to develop a novel
tiered approach consisting of (i) rapid and cost-efficient screening methods and (ii) confirmatory measurement
methods. The "NanoDefiner" eTool will guide potential end-users, such as concerned industries and regulatory bodies as well as enforcement and contract laboratories, to reliably classify if a material is nano or not. To achieve this objective, a comprehensive inter-laboratory evaluation of the performance of current
characterisation techniques, instruments and software is performed. Instruments, software and methods are
further developed. Their capacity to reliably measure the size of particulates in the size range 1-100 nm and
above (according to the EU definition) is validated. Technical reports on project results are published to
reach out to relevant stakeholders, such as policy makers, regulators, industries and the wider scientific community, to present and discuss our goals and results, to ensure a continuous exchange of views,
needs and experiences obtained from different fields of expertise and application, and to finally integrate the resulting feedback into our ongoing work on the size-related classification of nanomaterials.
Slicing - a new method for non destructive 3D elemental sensitive characterization of materials
(2014)
Recent advances in synchrotron sources and detector technology have led to substantial improvements in spatial resolution and detection limits for X-ray fluorescence analysis (XRF). However, the non-destructive three-dimensional elemental sensitive characterization of samples remains a challenge. We demonstrate the use of the so-called 'Color X-ray Camera' (CXC) for 3D measurements for the first time. The excitation of the sample is realized with a thin sheet-beam. The stepwise movement of the sample allows getting the elemental distribution for each layer with one measurement. These layers can be combined to a full 3D dataset for each element afterwards. Since the information is collected layer by layer, there is no need to apply reconstruction techniques, which quite often are the reason for artifacts in the results achieved by computed tomography (CT). The field of applications is wide, as the 3D elemental distribution of a material contains clues to processes inside the samples from a variety of origins. The technique is of special interest and well suited for biological specimens, because their light matrix minimizes restricting absorption effects. Measurement examples of a hornet and the teeth of a Sorex araneus are shown.
Using ultrafast X-ray diffraction, we study the coherent picosecond lattice dynamics of photoexcited thin films in the two limiting cases, where the photoinduced stress profile decays on a length scale larger and smaller than the film thickness. We solve a unifying analytical model of the strain propagation for acoustic impedance-matched opaque films on a semi-infinite transparent substrate, showing that the lattice dynamics essentially depend on two parameters: One for the spatial profile and one for the amplitude of the strain. We illustrate the results by comparison with high-quality ultrafast X-ray diffraction data of SrRuO3 films on SrTiO3 substrates.
Thermally reduced graphite oxide (TRGO), containing only four single carbon layers on average, was combined with ammonium polyphosphate (APP) and magnesium hydroxide (MH), respectively, in polypropylene (PP). The nanoparticle's influence on different flame-retarding systems and possible synergisms in pyrolysis, reaction to small flame, fire behavior and mechanical properties were determined. TRGO has a positive effect on the yield stress, which is decreased by both flame-retardants and acts as a synergist with regard to Young's modulus. The applicability and effects of TRGO as an adjuvant in combination with conventional flame-retardants depends strongly on the particular flame-retardancy mechanism. In the intumescent system, even small concentrations of TRGO change the viscosity of the pyrolysing melt crucially. In case of oxygen index (OI) and UL 94 test, the addition of increasing amounts of TRGO to PP/APP had a negative impact on the oxygen index and the UL 94 classification. Nevertheless, systems with only low amounts (≤1 wt%) of TRGO achieved V-0 classification in the UL 94 test and high oxygen indices (>31 vol%). TRGO strengthens the residue structure of MH and therefore functions as a strong synergist in terms of OI and UL 94 classification (from HB to V-0).
The vibrational density of states of a series of homologous triphenylene-based discotic liquid crystals HATn (n = 5, 6, 8, 10, 12) depending on the length of the aliphatic side chain is investigated by means of inelastic neutron scattering. All studied materials have a plastic crystalline phase at low temperatures, followed by a hexagonally ordered liquid crystalline phase at higher temperatures and a quasi isotropic phase at the highest temperatures. The X-ray scattering pattern for the plastic crystalline phase of all materials shows a sharp Bragg reflection corresponding to the intercolumnar distance in the lower q-range and a peak at circa 17 nm-1 related to intracolumnar distances between the cores perpendicular to the columns as well as a broad amorphous halo related to the disordered structure of the methylene groups in the side chains in the higher q-range. The intercolumnar distance increases linearly with increasing chain length for the hexagonal columnar ordered liquid crystalline phase. A similar behaviour is assumed for the plastic crystalline phase. Besides n = 8 all materials under study exhibit a Boson peak. With increasing chain length, the frequency of the Boson peak decreases and its intensity increases. This can be explained by a self-organized confinement model. The peaks for n = 10, 12 are much narrower than for n = 5, 6 which might imply the transformation from a rigid system to a softer one with increasing chain length. Moreover the results can also be discussed in the framework of a transition from an uncorrelated to a correlated disorder with increasing n where n = 8 might be speculatively considered as a transitional state.
Measurement of spontaneous magnetic stray field signals has been reported to be a promising tool for capturing macro-scale information of deformation states, defects and stress concentration zones in a material structure. This paper offers a new method for self-magnetic leakage field detection using a magneto-optical (MO) hand-held microscope. Its sensor has a dynamic field range between ±0.05 and ±2 kA/m and a lateral optical resolution of approx. 10 µm. We examined flat tensile test specimens of metastable austenitic steel AISI 304. Static tensile tests were repeatedly interrupted at various predetermined states of strain and the magnetic information was measured by the MO system. Comparative measurements using a high-precision magnetic field GMR-sensor, verify the outstanding capability of the MO microscope regarding spatial resolution of magnetic fields.
A mechanical structure supported by nonlinear springs subjected to an external load is considered. If all mechanical parameters of the system were known, the displacement of the system subjected to this load could be easily calculated. If not all of the parameters are known, but the load and the displacement are measured at one location, an inverse problem exists. In the presented problem the nonlinear springs are unknown and have to be determined. At first glance a problem needs to be solved, which is underdetermined due to the number of unknown variables. However, evolutionary computing can be applied to solve this inverse, nonlinear and multimodal problem. Sometimes a prior knowledge exists on certain system properties, which is difficult to implement into analytical or numerical solver. This knowledge can play a decisive role in identifying the system properties and it can be easily included as boundary condition when applying evolutionary algorithm. This article examines how and under what conditions the spring resistances can be identified. The procedure is exemplified at a mechanical system of a pile foundation.
Two metal organic structures composed of the ligands benzene-1,4-dicarboxylate and pyridine-2,5-dicarboxylate and bismuth cations are presented: (H2Im)[Bi(1,4-bdc)2] (1) and [Bi(pydc)(NO3)2(H2O)2]*H2O (2) (bdc = benzenedicarboxylate, H2Im = imidazole cation, pydc = pyridinedicarboxylate). Both compounds were synthesised via grinding and the crystal structure of compound (2) was solved based on its powder diffraction pattern. Compound 1 crystallises isostructurally to the dimethyl ammonium containing compound (dma)[(Bi(1,4-bdc)2]. Raman spectroscopy and Extended X-ray absorption fine structure (EXAFS)
measurements provided additional information about the two mechanochemically synthesised metal organic compounds.
Der Large Hadron Collider (LHC) des europäischen Kernforschungszentrums CERN ist einer der weltweit größten und leistungsfähigsten Teilchenbeschleuniger. Um den Teilchenstrahl auf seiner Kreisbahn zu halten, werden mit Hilfe supraleitender Spulen sehr starke Magnetfelder erzeugt. Die hierzu benötigten hohen Ströme werden über Verbunddrähte aus Niob-Titan und Kupfer geleitet.
Die Drähte werden u.a. durch Ultraschallschweißungen miteinander verbunden. Eine mangelhafte Verbindung kann zur Erwärmung der Kontaktstelle und in Folge davon zum Zusammenbruch der Supraleitung führen. Auf Anfrage des CERN wurden an der BAM Untersuchungen zur Prüfbarkeit solcher Verbindungen bei Umgebungstemperatur durchgeführt. Es gelang, für einen Verbindungstypen einen Wirbelstromsensor für eine manuelle Prüfung zu entwickeln. Ein Prototyp des Sensors befindet sich beim CERN in der praktischen Erprobung. Das Sensorprinzip sowie Prüfergebnisse aus Labor und Praxis werden vorgestellt.
This survey will discuss current and emerging isothermal and rapid polymerase chain reaction (PCR) based nucleic acid amplification methods for patient near diagnostics. To assess the clinical need of rapid diagnostics for infectious diseases based on nucleic acid tests (NATs) we performed and analysed a questionnaire among laboratories participating in corresponding INSTAND ring trials for external quality assurance. The questions concerning new amplification technologies like isothermal nucleic acid amplification, potentially suited to significantly decrease turnaround times, were complemented by questions to evaluate the present status of NATs. Besides end-users, companies were also addressed by sending out a manufacturer specific questionnaire. Analysis of the answers from 48 laboratories in 14 European countries revealed that a much shorter turnaround time is requested for selected pathogens compared to about 2 h or longer when applying temperature cycling amplification, i.e. PCR. In this context, most frequently mentioned were MRSA, norovirus, influenza A and B viruses, cytomegalovirus (CMV) as well as hepatitis B virus (HBV) and hepatitis C virus (HCV). At present, 8% of the laboratories having participated in this survey apply isothermal amplification of nucleic acid to identify infectious pathogens.
Recent advances in vacuum sciences and applications are reviewed. Novel optical interferometer cavity devices enable pressure measurements with ppm accuracy. The innovative dynamic vacuum standard allows for pressure measurements with temporal resolution of 2 ms. Vacuum issues in the construction of huge ultra-high vacuum devices worldwide are reviewed. Recent advances in surface science and thin films include new phenomena observed in electron transport near solid surfaces as well as novel results on the properties of carbon nanomaterials. Precise techniques for surface and thin-film characterization have been applied in the conservation technology of cultural heritage objects and recent advances in the characterization of biointerfaces are presented. The combination of various vacuum and atmospheric-pressure techniques enables an insight into the complex phenomena of protein and other biomolecule conformations on solid surfaces. Studying these phenomena at solid–liquid interfaces is regarded as the main issue in the development of alternative techniques for drug delivery, tissue engineering and thus the development of innovative techniques for curing cancer and cardiovascular diseases. A review on recent advances in plasma medicine is presented as well as novel hypotheses on cell apoptosis upon treatment with gaseous plasma. Finally, recent advances in plasma nanoscience are illustrated with several examples and a roadmap for future activities is presented.
The combination of complementary characterization techniques such as SEM (Scanning Electron Microscopy), T-SEM (Scanning Electron Microscopy in Transmission Mode), EDX (Energy Dispersive X-ray Spectroscopy) and SAM (Scanning Auger Microscopy) has been proven to be a powerful and relatively quick characterization strategy for comprehensive morphological and chemical characterization of individual silica and titania nanoparticles. The selected real life test materials, silica and titania, are listed in the OECD guidance manual as representative examples because they are often used as commercial nanomaterials. Imaging by high resolution SEM and in the transmission mode by T-SEM allows almost simultaneous surface and in-depth inspection of the same particle using the same instrument. EDX and SAM enable the chemical characterization of bulk and surface of individual nanoparticles. The core–shell properties of silica based materials are addressed as well. Titania nominally coated by silane purchased from an industrial source has been found to be inhomogeneous in terms of chemical composition.
In order to investigate molecular recognition on surfaces, an azide-functionalized monolayer was deposited on gold. The monolayer was characterized by X-ray photoelectron spectroscopy (XPS) and angle-resolved near-edge X-ray absorption fine structure (NEXAFS) experiments and the decomposition of the azide upon irradiation with X-ray beams was investigated. Subsequently, various alkyne-functionalized host and guest molecules were attached to the azide by 1,3-dipolar cycloaddition. These modified surfaces and their host–guest chemistry were analysed by XPS and angle-resolved NEXAFS. The reversibility of guest binding was shown for one example as a proof of principle.
Untersuchung der Auflösungsgrenzen der Lockin-Thermografie zur Prüfung von Faserverbundwerkstoffen
(2014)
Aktive Thermografie mit Lockin-Anregung stellt ein berührungsfreies und zerstörungsfreies Prüfverfahren dar, welches insbesondere auch die Prüfung von kohlenstofffaserverstärkten Kunststoffen ermöglicht. Um eine Standardisierung dieses Verfahrens voranzubringen, wurden im Rahmen eines Forschungsprojektes umfangreiche Untersuchungen zur Validierung des Verfahrens durchgeführt.
Dabei wurden unter anderem der Einfluss der spektralen Empfindlichkeit verschiedener Kamerasysteme, unterschiedlicher Lagenaufbauten bei CFK-Probekörpern und der Einfluss einer Phasenverschiebung zwischen dem Anregungssignal und der Detektion der Thermografiebilder untersucht.
Recently, C K-edge Near Edge X-ray Absorption Fine Structure (NEXAFS) spectra of graphite (HOPG) surfaces have been measured for the pristine material, and for HOPG treated with either bromine or krypton plasmas (Lippitz et al., Surf. Sci., 2013, 611, L1). Changes of the NEXAFS spectra characteristic for physical (krypton) and/or chemical/physical modifications of the surface (bromine) upon plasma treatment were observed. Their molecular origin, however, remained elusive. In this work we study by density functional theory, the effects of selected point and line defects as well as chemical modifications on NEXAFS carbon K-edge spectra of single graphene layers. For Br-treated surfaces, also Br 3d X-ray Photoelectron Spectra (XPS) are simulated by a cluster approach, to identify possible chemical modifications. We observe that some of the defects related to plasma treatment lead to characteristic changes of NEXAFS spectra, similar to those in experiment. Theory provides possible microscopic origins for these changes.
Sealing and strengthening of the subsoil by injection is a major issue in the field of geotechnical engineering. One commonly applied method is jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty linked with this method is to predict the resulting column diameter and its material strength. In this paper we illustrate the application of a newly developed non-destructive quality assurance testing tool used to determine the diameter of jet grout columns. This approach incorporates standard crosshole and downhole seismic measurements. To demonstrate its effectiveness, we tested the new approach within two-dimensional finite-difference numerical simulations. Additional field tests showed that this tool is also applicable in real site conditions. For this purpose, three jet grout columns were produced with different process parameters in a depth between 3.0 and 10 m. The evaluated diameters were within 1.0 and 1.5 m, slightly deviating from the previously predicted range by the jet grouting contractor. Moreover, we were able to detect the base of the columns at 10 m depth with no significant difficulties. On the other hand, unsaturated, partly unconsolidated sands between ground water level and surface considerably affected the seismic data, hence complicating the detection of the top of the columns.
Challenging new constructions and ageing infrastructure are increasing the demand for permanent monitoring of loads and condition. Various methods and sensors are used for this purpose. But the technologies available today have difficulties in detecting slowly progressing locally confined damages. Extensive investigations or instrumentations are required so far for this purpose. In this study we present new sensors and data processing methods for ultrasonic transmission, which can be used for non-destructive long term monitoring of concrete. They can be mounted during construction or thereafter. Larger volumes can be monitored by a limited number of sensors for changes of material properties. The principles of ultrasonic transmission and influencing factors are presented. This latter include load, damages as well as environmental parameters as temperature or moisture. Various methods for data processing, e. g. coda wave interferometry are introduced. They allow the detection of very small changes in the medium. The embedded sensors are shown including mounting and operation. Application examples so far include small scale laboratory freeze-thaw experiments, localizing loads in larger concrete models, monitoring load effects on real structures as well as detecting acoustic events. Some sensors are operating already for several years. The sensors can be used as transmitter or receivers or switched between both roles. While most of the previous experiments have been active (at least one sensor serving as transmitter), new studies show that the sensors are useful as well for passive measurements, e. g. in acoustic emission or time reversal experiments. Besides application in civil engineering our setups can also be used for model studies in geosciences.
Elastic wave propagation of ultrasound in bituminous road surfaces - simulations and measurements
(2015)
Maintenance costs of road infrastructure are increasing steadily. The main cause of this is the nearly exponential increase of traffic during the last decades. Adverse environmental impacts on infrastructure get more and more important as well. Therefore, it is important to determine how limited financial resources can be directed with an optimum pay-out. Often a decision has to be made whether existing structures have to be rebuilt or repaired based on the condition of the structures. The present study takes first steps towards the usage of low-frequency ultrasound as a tool to evaluate the road condition. The overall aim is to derive a prediction model for future road conditions. In order to better understand and interpret recorded wave fields simulations of elastic wave propagation in layered and scattering road models have been performed. The study combined investigations in the laboratory with field measurements. In a series of extensive laboratory tests with different asphalt mixtures characteristic wave properties have been derived. Travel time (resp. velocity) as important material parameter has been investigated for different wave types, different centre frequencies and at various temperatures. An investigation of the directivity of wave radiation in the heterogeneous asphalt bodies led to an estimate of the related disturbing influences. Based on the laboratory results field measurements were performed on a real road and the records were processed to identify layers, propagation speeds and attenuation. The results were verified by a series of simulations.
Recently developed new transducers for ultrasonic transmission, which can be embedded right into concrete, are now used for non-destructive permanent monitoring of concrete. They can be installed during construction or thereafter. Large volumes of concrete can be monitored for changes of material properties by a limited number of transducers. The transducer design, the main properties as well as installation procedures are presented. It is shown that compressional waves with a central frequency of 62 kHz are mainly generated around the transducer's axis. The transducer can be used as a transmitter or receiver. Application examples demonstrate that the transducers can be used to monitor concrete conditions parameters (stress, temperature,
) as well as damages in an early state or the detection of acoustic events (e.g., crack opening). Besides application in civil engineering our setups can also be used for model studies in geosciences.
Ultrasonic echo testing is widely used in non-destructive testing in civil engineering to investigate concrete structures, to measure thickness, and to locate and characterise built-in components or inhomogeneities. Currently, synthetic aperture focusing techniques are mostly used for imaging. These algorithms are highly developed but have some limitations. For example, it is not possible to image the lower boundary of built-in components like tendon ducts or vertical reflectors. We adopted reverse time migration for non-destructive testing in civil engineering in order to improve the imaging of complicated structures in concrete. By using the entire wavefield, including waves reflected more than once, there are fewer limitations compared to synthetic aperture focusing technique algorithms. As a drawback, the required computation is significantly higher than that for the techniques currently used. Simulations for polyamide and concrete structures showed the potential for non-destructive testing. The simulations were followed by experiments at a polyamide specimen. Here, having acquired almost noise-free measurement data to test the algorithm, we were able to determine the shape and size of boreholes with sufficient accuracy. After these successful tests, we performed experiments at a reinforced concrete foundation slab. We obtained information from the data by reverse time migration, which was not accessible by traditional imaging. The imaging of the location and structure of the lower boundary of the concrete foundation slab was improved. Furthermore, vertical reflectors inside the slab were imaged clearly, and more flaws were found. It has been shown that reverse time migration is a step forward in ultrasonic testing in civil engineering.
Geophysical methods have been used in civil engineering for decades. The main field of application is - to no surprise – in geotechnical projects from site characterization to foundation quality assurance. For more than 25 years, ground penetrating radar (GPR) and seismic methods have found applications in structural engineering. Recently introduced geophysical methods have been adopted to ultrasonic investigations in various fields. They help to improve the quality of structural imaging and to detect small changes in concrete. An overview of the history and current use of geophysics in civil engineering is given. Selected examples of new concepts include advances in wave based imaging, quality assurance for foundations, detecting small changes in concrete as well as moisture and corrosion detection are discussed.
Various plant compartments of a single bell pepper plant were studied to verify the variability of boron isotope composition in plants and to identify possible intra-plant isotope fractionation. Boron mass fractions varied from 9.8 mg/kg in the fruits to 70.0 mg/kg in the leaves. Boron (B) isotope ratios reported as δ11B ranged from -11.0 to +16.0 (U ≤ 1.9, k=2) and showed a distinct trend to heavier δ11B values the higher the plant compartments were located in the plant. A fractionation of Δ11Bleaf-roots = 27 existed in the studied bell pepper plant, which represents about about 1/3 of the overall natural boron isotope variation (ca. 80). Two simultaneous operating processes are a possible explanation for the observed systematic intra-plant δ11B variation: 1) B is fixed in cell walls in its tetrahedral form (borate), which preferentially incorporates the light B isotope and the remaining xylem sap gets enriched in the heavy B isotope and 2) certain transporter preferentially transport the trigonal 11B-enriched boric acid molecule and thereby the heavy 11B towards young plant compartments which were situated distal of the roots and typically high in the plant. Consequently, an enrichment of the heavy 11B isotope in the upper young plant parts located at the top of the plant could explain the observed isotope systematic. The identification and understanding of the processes generating systematic intra-plant δ11B variations will potentially enable the use of B isotope for plant metabolism studies.
Characterization of silver nanoparticles in cell culture medium containing fetal bovine serum
(2015)
Nanoparticles are being increasingly used in consumer products worldwide, and their toxicological effects are currently being intensely debated. In vitro tests play a significant role in nanoparticle risk assessment, but reliable particle characterization in the cell culture medium with added fetal bovine serum (CCM) used in these tests is not available. As a step toward filling this gap, we report on silver ion release by silver nanoparticles and on changes in the particle radii and in their protein corona when incubated in CCM. Particles of a certified reference material, p1, and particles of a commercial silver nanoparticle material, p2, were investigated. The colloidal stability of p1 is provided by the surfactants polyethylene glycol-25 glyceryl trioleate and polyethylene glycol-20 sorbitan monolaurate, whereas p2 is stabilized by polyvinylpyrrolidone. Dialyses of p1 and p2 reveal that their silver ion release rates in CCM are much larger than in water. Particle characterization was performed with asymmetrical flow field-flow fractionation, small-angle X-ray scattering, dynamic light scattering, and electron microscopy. p1 and p2 have similar hydrodynamic radii of 15 and 16 nm, respectively. The silver core radii are 9.2 and 10.2 nm. Gel electrophoresis and subsequent peptide identification reveal that albumin is the main corona component of p1 and p2 after incubation in CCM that consists of Dulbecco's modified Eagle medium with 10% fetal bovine serum added.
SASfit: a tool for small-angle scattering data analysis using a library of analytical expressions
(2015)
SASfit is one of the mature programs for small-angle scattering data analysis and has been available for many years. This article describes the basic data processing and analysis workflow along with recent developments in the SASfit program package (version 0.94.6). They include (i) advanced algorithms for reduction of oversampled data sets, (ii) improved confidence assessment in the optimized model parameters and (iii) a flexible plug-in system for custom user-provided models. A scattering function of a mass fractal model of branched polymers in solution is provided as an example for implementing a plug-in. The new SASfit release is available for major platforms such as Windows, Linux and MacOS. To facilitate usage, it includes comprehensive indexed documentation as well as a web-based wiki for peer collaboration and online videos demonstrating basic usage. The use of SASfit is illustrated by interpretation of the small-angle X-ray scattering curves of monomodal gold nanoparticles (NIST reference material 8011) and bimodal silica nanoparticles (EU reference material ERM-FD-102).
Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectros-copy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical com-parison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory.
Hochduktiler Beton eröffnet neue Möglichkeiten bei der Instandsetzung von Bauwerken, der Herstellung dünnwandiger Bauelemente oder dem Einsatz von Dämpfungselementen in stoßartig beanspruchten Bauwerken (z.B. in Erdbebengebieten).
Die Steigerung der Duktilität kann durch die Zugabe von Kurzfasern erreicht werden. Im Falle einer Rissbildung in der Zementsteinmatrix überbrücken die Fasern den Riss, nehmen die Spannung vollständig auf und stoppen lokal das Risswachstum. Bei weiterer Steigerung der Last reißt die Matrix an anderer Stelle. Auf diese Weise wird die Rissbildung fein verteilt und es werden große Dehnungen erreicht, bevor das Bauteil versagt. Zur Optimierung der Festbetoneigenschaften müssen die Matrixfestigkeit und die Faserart sowie deren Gehalt aufeinander abgestimmt werden. Dabei sind auch die Verarbeitungseigenschaften des Frischbetons zu berücksichtigen.
Anhand der Schallemissionen kann die Rissbildung in der Matrix und die Interaktion mit den Fasern analysiert werden. So konnte in ersten Zugversuchen gezeigt werden, dass sich Schallereignisse dem Versagen der Zementsteinmatrix bzw. dem Auszug der Fasern aus der Matrix zuordnen lassen. Damit steht zur Beurteilung des mechanischen Verhaltens von hochduktilem Beton neben der Spannungs-Dehnungs-Linie ein weiteres Verfahren zur Verfügung.
Pigments and dyes
(2015)
The present volume is the main achievement of the Research Networking Programme ‘Comparative Oriental Manuscript Studies’, funded by the European Science Foundation in the years 2009–2014. It is the first attempt to introduce a wide audience to the entirety of the manuscript cultures of the Mediterranean East.
The chapters reflect the state of the art in such fields as codicology, palaeography, textual criticism and text editing, cataloguing, and manuscript conservation as applied to a wide array of language traditions including Arabic, Armenian, Avestan, Caucasian Albanian, Christian Palestinian Aramaic, Coptic, Ethiopic, Georgian, Greek, Hebrew, Persian, Slavonic, Syriac, and Turkish.
Seventy-seven scholars from twenty-one countries joined their efforts to produce the handbook. The resulting reference work can be recommended both to scholars and students of classical and oriental studies and to all those involved in manuscript research, digital humanities, and preservation of cultural heritage.
The volume includes maps, illustrations, indexes, and an extensive bibliography.
Dietary supplements high in isolated isoflavones are commercially available for human consumption primarily to alleviate menopausal symptoms in women. The isoflavone composition, quantity and importantly their estrogenic potency are poorly standardised and can vary considerably between different products. The aim of this study was to analyse the isoflavone composition of 11 dietary supplements based on soy or red clover using the HPLC/MS/MS technique. Furthermore, we investigated the transactivational potential of the supplements on the estrogen receptors (ER), ERα and ERβ, performing luciferase reporter gene assays. As expected, we found that the isoflavone composition varies between different products. The measured total isoflavone contents in various supplements were mostly comparable to those claimed by the manufacturers in their product information. However expressing the isoflavone content as isoflavone aglycone equivalents, soy-based supplements had a clearly lower quantity compared to the manufacturer information. All supplements transactivated more or less ERα and ERβ with a preference for ERβ. The transactivational efficiency exceeded partly the maximal 17β-estradiol induced ER activation. While the different soy-based supplements revealed similar transactivation potential to both ERs, red clover-based supplements differed considerably. We conclude that different commercial dietary supplements based on soy or red clover vary in their isoflavone composition and quantity. They are estrogenically active, although especially the red clover-based supplements show considerable differences in their estrogenic potential to ERα and ERβ. Thus, different isoflavone-rich products cannot be necessarily compared regarding possible biological effects.
Introducing fluorine into molecules has a wide range of effects on their physicochemical properties, often desirable but in most cases unpredictable. The fluorine atom imparts the C–F bond with low polarizability and high polarity, and significantly affects the behavior of neighboring functional groups, in a covalent or noncovalent manner. Here, we report that fluorine, present in the form of a single fluoroalkyl amino acid side chain in the P1 position of the well-characterized serine-protease inhibitor BPTI, can fully restore inhibitor activity to a mutant that contains the corresponding hydrocarbon side chain at the same site. High resolution crystal structures were obtained for four BPTI variants in complex with bovine b-trypsin, revealing changes in the stoichiometry and dynamics of water molecules in the S1 subsite. These results demonstrate that the introduction of fluorine into a protein environment can result in “chemical complementation” that has a significantly favorable impact on protein–protein interactions.
The adsorption of porphyrin derivatives on a Au(111) surface was studied by scanning tunneling microscopy and spectroscopy at low temperatures in combination with density functional theory calculations. Different molecular appearances were found and could be assigned to the presence of single gold adatoms bonded by a coordination bond underneath the molecular monolayer, causing a characteristic change of the electronic structure of the molecules. Moreover, this interpretation could be confirmed by manipulation experiments of individual molecules on and off a single gold atom. This study provides a detailed understanding of the role of metal adatoms in surface–molecule bonding and anchoring and of the appearance of single molecules, and it should prove relevant for the imaging of related molecule–metal systems.
The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (Xref). The standard uncertainties associated to the assigned values (uref) were calculated by combining the uncertainty of the characterisation (uchar) with a contribution for homogeneity (ubb) and for stability (ust), whilst uchar was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σp, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39.
Micro structured reactors are attractive candidates for further process intensification in heterogeneous catalysis. However, they require catalytic coatings with significantly improved space-time yields compared to traditional supported catalysts. We report the facile synthesis of homogeneous nanocrystalline Pt coatings with hierarchical pore structure by electrochemical dealloying of amorphous sputter-deposited platinum silicide layers. Thickness, porosity and surface composition of the catalysts can be controlled by the dealloying procedure. XPS analysis indicates that the catalyst surface is primarily composed of metallic Pt. Catalytic tests in gas-phase hydrogenation of butadiene reveal the typical activity, selectivity and activation energy of nanocrystalline platinum. However, space time yields are about 13 to 200 times higher than values reported for Pt-based catalysts in literature. The highly open metallic pore structure prevents heat and mass transport limitations allowing for very fast reactions and reasonable stability at elevated temperatures.
Lewis and Brønsted sites were quantified in a series of weak acidic hydroxylated magnesium fluorides by Fourier transform infrared spectroscopy (FTIR) and solid state nuclear magnetic resonance spectroscopy (NMR) with pyridine as probe molecule. Molar extinction coefficients, which are necessary for quantitative FTIR measurements, were calculated by an easy approach. It utilizes the fact that both signals, used for the quantification by FTIR, are caused by the same deformation vibration mode of pyridine. Comparison of quantitative FTIR experiments and quantification by NMR shows that concentrations of acidic sites determined by FTIR spectroscopy have to be interpreted with caution. Furthermore, it is shown that the transfer of molar extinction coefficients from one catalyst to another may lead to wrong results. Molar extinction coefficients and concentrations of acidic sites determined by FTIR spectroscopy are affected by grinding and probably the particle size of the sample. High temperature during FTIR experiments has further impact on the quantification results.
While polymorphism is a common phenomenon in the crystallization processes of organic compounds, polyamorphism has gained importance only recently. Using sophisticated sample environments and applying in situ scattering methods and vibrational spectroscopy, the complete crystallization process of organic compounds from solution can be traced and characterized. Diffuse scattering from amorphous intermediates can be investigated by analyzing the atomic pair distribution function (PDF) to gain further insights into molecular pre-orientation. The crystallization behavior of paracetamol was studied exemplarily under defined, surface-free conditions. Based on the choice of the solvent, the formation of different polymorphs is promoted. The thermodynamically stable form I and the metastable orthorhombic form II could be isolated in pure form directly from solution. For both polymorphs, the crystallization from solution proceeds via a distinct amorphous precursor phase. PDF analyses of these different amorphous states indicate a specific pre-orientation of the analyte molecules introduced by the solvent. The resulting crystalline polymorph is already imprinted in these proto-crystalline precursors. Direct experimental evidence for the polyamorphism of paracetamol is provided.
The need for technological progress in bio-diagnostic assays of high complexity requires both fundamental research and constructing efforts on nano-scaled assay recognition elements that can provide unique selectivity and design-enhanced sensitivity features. Nanoparticle induced sensitivity enhancement and its application related to multiplexed capability Surface-Enhanced InfraRed Absorption (SEIRA) assay formats are well suitable for these purposes. The potential of diverse fluorophore–antibody conjugates, being chemisorbed onto low-cost gold nanoparticulate SEIRA substrates, has been explored with respect to their spectral discriminability. These novel biolabels deliver molecular SEIRA fingerprints that have been successfully analyzed by both uni- and multivariate analyzing tools, to discriminate their multiplexing capabilities. We show that this robust spectral encoding via SEIRA fingerprints opens up new opportunities for a fast, reliable and multiplexed high-end screening in biodiagnostics.
The demands for the assessment of water quality are increasing steadily, making it necessary to routinely monitor multiple contaminants in water samples. For this application a hapten microarray was developed. In order to reach the required low detection limits a design of experiments (DoE) approach was used to optimize the assay performance. Here we show that a Box-Behnken design plan is an adequate choice for the straightforward exploration of hapten microarray assay parameters. For both read-out systems studied (fluorophore-labelled detection antibodies or enzymatic signal development followed by reflectometric scan, respectively), it was possible to significantly extend the measurement ranges. Furthermore, it could be shown that multivariate data analysis, here partial least squares regression (PLS), can improve the prediction accuracy of 'unknown' samples when used as calibration model, compared to classical, univariate data evaluation methods.
A novel synthetic strategy toward highly fluorinated BODIPY dyes with exceptional photostabilities relying on sustainable gold catalysis has been developed. A key to the tailored pyrrole precursors is the gold catalysis performed in ionic liquids as the reaction medium, allowing a facile recycling of the catalysts. The dyes prepared are well-matching with the spectral windows of popular rhodamine dyes and possess high brightness while showing a distinctly higher photostability than the rhodamines especially in aprotic solvents.
Magneto-resistive (MR) sensor arrays are suited for high resolution eddy current testing (ET) of aerospace components due to two significant advantages compared to conventional coil systems. First, to obtain high spatial resolution they can be manufactured down to the µm-regime without losing their outstanding field sensitivity. Secondly, MR technology has a relatively frequency-independent sensitivity in the range of common ET-frequencies thus providing a benefit for low frequency applications.
This paper presents measurements using MR array probes consisting of 32 TMR-elements (tunnel magneto resistance), an ASIC, and subsequent readout components. A source for generating the eddy currents inside the material under test is also implemented onboard of the PCB. These probes were developed in the IMAGIC-project* for detection and imaging of surface breaking defects.
The performance of the new sensor system has been investigated for several mock-ups, Aluminum and Titanium plate specimens having small adjacent boreholes with diameter of 0.44 mm and micro notches in the µm-range, respectively. To compare our results we used conventional eddy current probes. The MR sensor elements have a length of around 60 µm leading to a nearly 'point like' measurement. Neighbouring boreholes (depth 0.25 mm) with a separation of 0.6 mm between their centres could be resolved with a good SNR, and more important, the boreholes could be confidently distinguished using the TMR-probes. In case of conventional probes a reliable separation was not possible. In this paper we present the MR-ET-probes of the IMAGIC consortium and a comparison with conventional techniques.
*The IMAGIC-project ('Integrated Magnetic imagery based on spIntronics Components', 2011 – 2014, project reference: 288381) was funded by the European Commission, Seventh Framework Programme. Further partners involved in the consortium beside BAM and CEA were INESC-ID and INESC-MN (Portugal), Sensitec GmbH (Germany), Tecnatom S.A. (Spain), and Airbus Group (France).
Defect detection in concrete pile using impulse response measurements with sine sweep excitations
(2015)
For pile integrity inspection, a low cost and portable shaker was used to create the sine sweep signal for pile excitation. The impulse response function, calculated by the deconvolution of pile response from the sine sweep excitation, was proposed to identify the echoes in the piles due to the pile’s impedance changes. The proposed methodology has been evaluated and validated both numerically and experimentally. Based on the results from the simulations and experiments, it was found that the impulse response measurement with sine sweep excitation could be an effective tool to detect the echoes of the pile toe and the defects in the pile.
Für die Prüfung von Leichtbaustrukturen ist in den letzten Jahren ein vermehrter Einsatz der Luftultraschallprüfung zu verzeichnen. Insbesondere eignet sich Luftultraschall für die Prüfung von Faserkunststoffverbunden und hybrider Werkstoffverbunde, die ihre Anwendung in der Automobilindustrie und Luftfahrt finden. Für den Bau von marktüblichen Luftultraschall-Wandlern werden Piezokomposite mit Anpassschichten versehen. Ihre Herstellung ist allerdings sehr anspruchsvoll und die erreichbaren Signal-Rausch-Abstände sind für viele Prüfprobleme als noch nicht ausreichend einzustufen. Zwecks gesteigerter Effizienz beim Schallübertrag in die Luft wurden Luftultraschall-Sender und -Empfänger aus zellulärem Polypropylen entwickelt. Dieses piezoelektrische Material ist aufgrund seiner geringer Dichte und seiner sehr geringen Schallgeschwindigkeit an die niedrige akustische Impedanz der Luft deutlich besser angepasst, als die üblicherweise verwendeten Anpassschichten. Letztere können bei Polypropylen-Wandlern daher gänzlich vermieden werden.
In diesem Beitrag wird Luftultraschall-Prüfung an zwei verschiedenen CFK-Testkörpern vorgestellt: an einer Platte mit T-Stringern aus dem Seitenleitwerk eines Flugzeugs und an einer Platte mit künstlich eingebrachten Fehlern. Es wurde mit unterschiedlichen planaren und fokussierenden Wandlern geprüft. Marktübliche Wandler mit Anpassschichten wurden mit den selbstentwickelten Wandlern aus zellulärem Polypropylen verglichen. Der Signal-Rausch-Abstand und die laterale Auflösung wurden sowohl im Prüfaufbau mit senkrechter Einschallung als auch mit Schrägeinschallung gemessen. Die Ergebnisse zeigen, dass die Schrägeinschallung zwar den Signal-Rauschabstand erhöht, aber die laterale Auflösung verschlechtern kann.
CONRAD-2 is an imaging instrument using low-energy (cold) neutrons. The instrument is installed at the end of a curved neutron guide which avoids the direct line of sight towards the reactor core. This ensures a very low background of high-energy neutrons and. photons at the sample position. The cold neutron beam provides a wavelength range which is suitable for phase-and diffraction-contrast imaging such as grating interferometry and Bragg edge mapping. The instrument is well suited for high resolution imaging due to the high efficiency of the very thin scintillators that can be used for the detection of cold neutrons. An instrument upgrade was performed recently as a part of an upgrade program for the cold neutron instrumentation at HZB. The parameters of the instrument as well as some research highlights will be presented.
Several ultrasonic approaches for material determination are formulated in terms of an (nonlinear) inverse problem, e.g. immersion technique (Castaings et al. (2000)) or plate-waveguide techniques (Marzani et al. (2012)). In this contribution we focus on cylindrical waveguides for ultrasonic material determination and especially on the sensitivity of recorded transmission signals to the material properties. We utilize composite scaled sensitivities to determine the information content that can be achieved by the setup to certain parameters and discuss the limitations of the approach.