Wissenschaftliche Artikel der BAM
Filtern
Dokumenttyp
- Zeitschriftenartikel (353)
- Sonstiges (6)
- Beitrag zu einem Tagungsband (1)
- Corrigendum (1)
Sprache
- Englisch (351)
- Deutsch (9)
- Mehrsprachig (1)
Schlagworte
- Fluorescence (52)
- Quantum yield (35)
- Sensor (24)
- Lifetime (21)
- Quality assurance (20)
- Dye (18)
- Photophysics (18)
- Nano (16)
- Immunoassay (13)
- Synthesis (13)
- Magnetic resonance imaging (12)
- NIR (12)
- Photoluminescence (12)
- Cancer (11)
- Imaging (11)
- Lanthanide (10)
- Nanomaterial (10)
- Nanoparticle (10)
- Method (9)
- Nanoparticles (9)
- Particle (9)
- Quantum dots (9)
- ELISA (8)
- Electrochemistry (8)
- ICP-MS (8)
- Mass spectrometry (8)
- Mechanism (8)
- Molecularly imprinted polymers (8)
- Reference material (8)
- Energy transfer (7)
- Raman spectroscopy (7)
- Soil (7)
- Traceability (7)
- Affinity chromatography (6)
- Contrast agent (6)
- Gadolinium (6)
- Luminescence (6)
- MRI (6)
- Mass Spectrometry (6)
- Multiplexing (6)
- Mycotoxins (6)
- Optical probe (6)
- PH (6)
- Surface chemistry (6)
- Upconversion nanoparticle (6)
- Core-shell particles (5)
- Cr(III) (5)
- Flow cytometry (5)
- IgG (5)
- Laser ablation (5)
- Ligand (5)
- Microscopy (5)
- Raman microspectroscopy (5)
- Reproducibility (5)
- Single particle (5)
- Aggregation (4)
- Analytical Chemistry (4)
- Antikörper (4)
- Biosensor (4)
- Brightness (4)
- Cement (4)
- HPLC (4)
- Immunosensor (4)
- Industry 4.0 (4)
- Interlaboratory comparison (4)
- LA-ICP-MS (4)
- LC-MS/MS (4)
- LIBS (4)
- Lab-on-a-chip (4)
- Metabolomics (4)
- Nitrotyrosine (4)
- Polymer (4)
- Protein A (4)
- Quantitative spectroscopy (4)
- SWIR (4)
- Signal enhancement (4)
- XPS (4)
- XRF (4)
- Air pollution (3)
- Allergy (3)
- Antibiotics (3)
- Antibodies (3)
- BODIPY (3)
- Bead (3)
- Biosensing (3)
- Bisphenol A (3)
- Brain (3)
- Calibration (3)
- Coating (3)
- Complex (3)
- Copper (3)
- Corrosion (3)
- Crystal (3)
- DNA origami (3)
- Diagnostics (3)
- Ergot alkaloids (3)
- Excitation power density (3)
- Extracellular matrix (3)
- FPLC (3)
- Food (3)
- Food analysis (3)
- Gadofosveset (3)
- Gas chromatography (3)
- General Medicine (3)
- HRMS (3)
- High-resolution mass spectrometry (3)
- Human serum (3)
- Hybridoma (3)
- Hydrolysis (3)
- Immunocapture (3)
- Immunoglobulins (3)
- Iron oxide (3)
- Isotope dilution (3)
- Isotope ratio (3)
- MOF (3)
- Mass Spectroscopy (3)
- Mechanochemistry (3)
- Metrology (3)
- Microfluidics (3)
- Molecular imaging (3)
- Molecular imprinting (3)
- Monoclonal antibody (3)
- Mycotoxin (3)
- NMR (3)
- Nitration (3)
- Optical spectroscopy (3)
- PFAS (3)
- Pollution (3)
- Process Industry (3)
- Protein G (3)
- Quality Control (3)
- Quantification (3)
- Raman (3)
- Reference materials (3)
- Screening (3)
- Sensitization (3)
- Spectroscopy (3)
- Switch (3)
- Teststreifen (3)
- Transformation products (3)
- Tyrosine (3)
- Uncertainty (3)
- Upconversion (3)
- AAS (2)
- Absolute isotope ratio (2)
- Adsorption (2)
- Affinity Chromatography (2)
- Affinitätschromatographie (2)
- Aggregation induced emission (2)
- Amorphous carbon (2)
- Amoxicillin (2)
- Amperometry (2)
- Antibody (2)
- Antibody coating (2)
- Aromatic amino acid analysis (2)
- Atherosclerosis (2)
- Bacteria (2)
- Barcoding (2)
- Bead-based assay (2)
- Benz[a]anthracene (BaA) (2)
- Benzo[a]pyrene (BaP) (2)
- Biochemistry (2)
- Biochip (2)
- Biocides (2)
- Bioconjugation (2)
- CONSENS (2)
- Cell proliferation (2)
- Certified reference material (2)
- Charge transfer (2)
- Chromatography (2)
- Comparability (2)
- Core−shell particles (2)
- Cuprorivaite (2)
- Cytotoxicity (2)
- Degradation (2)
- Delta scale (2)
- Derivatization (2)
- Diagnosis (2)
- Digitalisation (2)
- Dimerization (2)
- Dityrosine (2)
- Documentation (2)
- Egyptian blue (2)
- Electron microscopy (2)
- Emission spectroscopy (2)
- Endocrine disruptor (2)
- Endokrine Disruptoren (2)
- Enhancement (2)
- Environmental Chemistry (2)
- Exocytosis (2)
- Fatty acid metabolism (2)
- Fertilizer (2)
- Ferumoxytol (2)
- Fluoride (2)
- Gas chromatography (GC) (2)
- General Earth and Planetary Sciences (2)
- Glyphosate (2)
- Gold nanoparticles (2)
- HPLC-MS/MS (2)
- HTS (2)
- Health, Toxicology and Mutagenesis (2)
- Heart failure (2)
- Hydrazinolysis (2)
- ICP-OES (2)
- Immunoaffinity extraction (2)
- Immunoprecipitation (2)
- Indium phosphide (2)
- Indoor air (2)
- Inflammation (2)
- Iron (2)
- Isotope (2)
- Isotope dilution (ID) (2)
- Isotope ratios (2)
- LIF (2)
- Label (2)
- Lanthanides (2)
- Lateral flow assay (2)
- Life sciences (2)
- Limit of detection (2)
- Lipidomic profile (2)
- Liquid chromatography (LC) (2)
- Lithium (2)
- MALDI (2)
- MALDI-TOF MS (2)
- MC-ICP-MS (2)
- Magnetic beads (2)
- Mass spectrometry (MS) (2)
- Measurement uncertainty (2)
- Mercury (2)
- Mesoporous materials (2)
- Metabolic stress (2)
- Method development (2)
- Microarray (2)
- Microbeads (2)
- Mikrofluidik (2)
- Mikroplastik (2)
- Modelling (2)
- Modular Production (2)
- Molecularly Imprinted Polymers (2)
- Monoclonal Antibodies (2)
- Monolithic column (2)
- Multiplex (2)
- Nanomaterials (2)
- Nickel (2)
- Nitrogen oxides (2)
- Nontarget analysis (2)
- Open Science (2)
- Optical detection (2)
- Origami (2)
- Oxygen (2)
- Ozone (2)
- Passivation (2)
- Peptide (2)
- Peptide library (2)
- Phenylalanine (2)
- Phosphorylated peptides (2)
- Photodegradation (2)
- Polycyclic aromatic hydrocarbon (PAH) (2)
- Probe (2)
- Process Analytical Technology (2)
- Process analytical technology (2)
- Production (2)
- Prostate cancer (2)
- Protein (2)
- Protein nitration (2)
- Proximity-enhanced reaction (2)
- Purification (2)
- Quality control (2)
- Quantum dot (2)
- Real-time process monitoring (2)
- Regeneration (2)
- Sapphire (2)
- Self-assembly (2)
- Sensorpartikel (2)
- Sensors (2)
- Sequence coverage (2)
- Serum (2)
- Sewage sludge (2)
- Shell (2)
- Sialic acid (2)
- Single molecule (2)
- Smart sensors (2)
- Software (2)
- Solid state NMR (2)
- Sr isotopes (2)
- Standardization (2)
- Standards (2)
- Surface (2)
- Synthetic peptides (2)
- Sythesis (2)
- Test strips (2)
- Theory (2)
- Thermal anhydrite (2)
- Thermal desorption (2)
- Toxicity (2)
- Transformation product (2)
- Triple isotope fractionation (2)
- Triplet-triplet annihilation (2)
- Tumor (2)
- Tumor metabolism (2)
- Ultrafine particles (2)
- Upconversion nanoparticles (2)
- Uptake studies (2)
- Validation (2)
- Wasser (2)
- Water analysis (2)
- Yb(III) complex (2)
- ZIF (2)
- ZIF-8 (2)
- 1-indanol (1)
- 150th anniversary (1)
- 150th anniversary of BAM (1)
- 2,5-dihydroxyacetophenone (1)
- 280 nm (1)
- 2D chromatography (1)
- 3D-Mikrofluidik (1)
- 6xHis (1)
- AAA (1)
- AAAA (1)
- ABC (1)
- ABID (1)
- AF4 (1)
- AIE (1)
- AIS (1)
- ATCUN (1)
- Aautomatisation (1)
- Absorption (1)
- Abwasser (1)
- Acoustic (1)
- Acoustic resonance (1)
- Acrylamide (1)
- Acute myocardial infarction (1)
- Additive Fertigung (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Adsorbable organically bound fluorine (AOF) (1)
- Adulteration (1)
- Advanced Materials (1)
- Advanced material (1)
- Advanced materials (1)
- Advanced nanomaterials (1)
- Affinity (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Affinity extraction (1)
- Affinitätsextraktion (1)
- AgInS (1)
- Agarose (1)
- Aggregates (1)
- Aggregation-induced emission (1)
- Aging (1)
- Agriculture (1)
- Air filter samples (1)
- Air particulate matter (1)
- Air sampling (1)
- Airport (1)
- AlCl (1)
- Alanine scan (1)
- Algorithms (1)
- Altenuene (1)
- Alternaria mycotoxins (1)
- Aluminum (1)
- Aluminum oxide (1)
- Alzheimer’s disease (1)
- Amino acid analysis (1)
- Amplification (1)
- Amyloid-beta (1)
- Analysis (1)
- Analytical methods (1)
- Analytical sciences (1)
- Aneurysm (1)
- Angiography (1)
- Angiotensin II (1)
- Anhydrite (1)
- Aniline (1)
- Animal slurry (1)
- Anion recognition (1)
- Antagonists (1)
- Anthropocene (1)
- Antibody Purification (1)
- Antibody identification (1)
- Antibody-gated indicator delivery (1)
- Antifouling surface (1)
- Antigens (1)
- Antimicrobial resistance (1)
- App (1)
- Application (1)
- Aptamere (1)
- Aqueous quantum dot (1)
- Aqueous synthesis (1)
- Arabidopsis (1)
- Argon (1)
- Array (1)
- Arsenite (1)
- Artificial Neural Networks (1)
- Artificial intelligence (1)
- Artificial neural networks (1)
- Artificial weathering (1)
- Ash content (1)
- Aspergillus (1)
- Assay (1)
- Atherosclerotic plaques (1)
- Atmospheric aerosol (1)
- Atomic Absorption Spectrometry (1)
- Atomic absorption spectrometry (1)
- Atomic and molecular physics, and optics (1)
- Atomic force microscopy (1)
- Atomic weight (1)
- Augenbohne (1)
- Autoantibodies (1)
- Automated Purification (1)
- Automated image analysis (1)
- Automation (1)
- Autophagy (1)
- Aviation (1)
- Aza-BODIPY (1)
- BAM (1)
- BCA test (1)
- BODIPY dyes (1)
- BODIPY probe (1)
- BODIPYs (1)
- BPA removal (1)
- Back-side integration (1)
- Bacterial lipopolysaccharides (1)
- Bacterial lysates (1)
- Ball milling (1)
- Bassanite (1)
- Bead injections (1)
- Benchmarking study (1)
- Benchtop NMR (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Benzin (1)
- Benzothiadiazole (1)
- Benzoxadiazole dyes (1)
- Beschichtung (1)
- Bet v 1 (1)
- Betula pendula (1)
- Binary gas mixture (1)
- Binder (1)
- Binding molecule (1)
- Bioanalysis (1)
- Biodiesel (1)
- Biodiesel fuel (1)
- Biofilm (1)
- Bioinformatics (1)
- Biokorrosion (1)
- Biology (1)
- Biomarker (1)
- Biomarkers (1)
- Biomimicry (1)
- Biosensoren (1)
- Biosensors (1)
- Bioseparation (1)
- Biosilicification (1)
- Biosynthesis (1)
- Biotechnology (1)
- Biotests (1)
- Birch pollen allergen (1)
- Bismuth (1)
- Boden (1)
- Boltzmann plot (1)
- Bombs (1)
- Border surveillance (1)
- Boron compound (1)
- Borosilicate Glass (1)
- Borosilicatglas (1)
- Borosilikatglas (1)
- Bovine serum albumin (BSA) (1)
- Bradford (1)
- Building material (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- Byproducts (1)
- C-C coupling (1)
- CCQM (1)
- CE/MC-ICP-MS (1)
- CEA (1)
- CO2 + n-alkanes (1)
- COVID-19 (1)
- CRM (1)
- CRP (1)
- CUINS2 nanocrystals (1)
- CaCl emission bands (1)
- Cadmium (1)
- Calcite (1)
- Calcium (1)
- Calcium carbonate (1)
- Calcium carbonates (1)
- Calibrated fluorescence measurements (1)
- Calibration-free analysis (1)
- Cancer awareness measure (1)
- Cancer cells (1)
- Cancer risk (1)
- Canine olfactometry (1)
- Carbamazepine (1)
- Cardiac troponin (1)
- Cardiolipins (1)
- Cardiovascular (1)
- Carrier (1)
- Carrier protein (1)
- Carrier-Material (1)
- Carriers (1)
- Cconventional method (1)
- Cell studies (1)
- Cellular substructure (1)
- Cellulose (1)
- Cement clinker remnants (1)
- Cerium oxide (1)
- Charged dyes (1)
- Chelate (1)
- Chemical Process Control (1)
- Chemical Safety (1)
- Chemical evolution (1)
- Chemical protein modification (1)
- Chemiluminescence (1)
- Chemodosimeter (1)
- Chemometrics (1)
- Chicken antibodies (1)
- Chirality (1)
- Chlorides (1)
- Chlorine (1)
- Chlorine determination (1)
- Chloroanilines (1)
- Ciaaw.org (1)
- Citation (1)
- Citizen Science (1)
- Citrullinated (1)
- Classical primary measurement method (CPM) (1)
- Classification (1)
- Cleaning (1)
- Cleavage (1)
- Click chemistry (1)
- Climate (1)
- Clinical Biochemistry (1)
- Clones (1)
- Cmos (1)
- Cobaloxime complex (1)
- Cocoa (1)
- Collaborative trial (1)
- Collagen (1)
- Collection (1)
- Colloidal semiconductor nanocrystals (1)
- Color (1)
- Column holder (1)
- Combinatorial chemistry (1)
- Combinatorial peptide library (1)
- Combustion (1)
- Combustion Ion Chromatography (1)
- Combustion ion chromatography (CIC) (1)
- Commercial metal-organic frameworks (1)
- Commercialization (1)
- Compartmentalization (1)
- Competitive Immunoassay (1)
- Complexation (1)
- Compound-independent calibration (1)
- Concentration step (1)
- Concrete (1)
- Confiscation (1)
- Conformation (1)
- Conjugate (1)
- Construction (1)
- Construction products (1)
- Consumer Products (1)
- Continuous Processes (1)
- Continuous Sensor (1)
- Continuous processes (1)
- Conventional isotope ratio (1)
- Converter material (1)
- Coordination polymer (1)
- Core-shell (1)
- Core–shell particles (1)
- Corona virus (1)
- Corophium volutator (1)
- Corundum (1)
- Cr(III) complex (1)
- Cross section (1)
- Cross-sectioning (1)
- Crosslinker (1)
- Cryoadsorption (1)
- Cucurbituril (1)
- Customs (1)
- Cyanide in soil (1)
- Cyber-Physical Systems (1)
- Cyber-physical system (1)
- Cyclic voltammetry (1)
- Cyclometalated iridium (III) complexes (1)
- Cytoplasm (1)
- DFA (1)
- DFT (1)
- DHAP (1)
- DNA (1)
- DNA radiation damage (1)
- DNA strand breaks (1)
- DPA (1)
- Damage-associated molecular patterns (DAMPs) (1)
- Data (1)
- Data Fusion (1)
- Data infrastructures (1)
- Data processing (1)
- De novo peptide sequencing (1)
- Deep learning-based tools (1)
- Degradation of refrigerants (1)
- Delta isotope standard (1)
- Delta value (1)
- Dendrimer (1)
- Density data (1)
- Design of experiment (1)
- Detection (1)
- Deterioration (1)
- Development (1)
- Diagnostic Antibodies (1)
- Diastolic dysfunction (1)
- Diatomic molecule (1)
- Diclofenac (1)
- Diesel exhaust (1)
- Diffusion (1)
- Digestion (1)
- Digital Transformation (1)
- Digital Twins (1)
- Digital holographic cytometry (1)
- Digital immunoassay (1)
- Digital representations (1)
- Digital transformation (1)
- Digital twins (1)
- Digital workflows (1)
- Digitalisierung der Prozessindustrie (1)
- Digitization of process industry (1)
- Dip-stick assay (1)
- Disinfection (1)
- Dissolution (1)
- Dityrosine crosslinking (1)
- Docking (1)
- Down Stream Processing (1)
- Downstream Processing (1)
- Downstream processing (1)
- Druckstabilität (1)
- Drug Discovery (1)
- Drug search (1)
- Drug trafficking (1)
- Dual sensing (1)
- Dual-color labeling glycan (1)
- Duplex stainless steels (1)
- Dyad (1)
- Dye loading optimisation (1)
- Dye monomers (1)
- Dye release (1)
- Dyes (1)
- Dyes/pigments (1)
- Dynamic calibration gas mixtures (1)
- EC/MS (1)
- ECR (1)
- EDTAD (1)
- EP-3533 (1)
- ESMA (1)
- EU-WFD (1)
- EXAFS (1)
- Early Earth (1)
- Ecotoxicity (1)
- Editorial (1)
- Elastin (1)
- Elastin-specific contrast agent ESMA (1)
- Elastin-specific molecular agent (1)
- Electrochemical (1)
- Electrochemical titration (1)
- Electron transfer (1)
- Elektrochemie (1)
- Elektrochemilumineszenz (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Emergency (1)
- Emission testing (1)
- Enantiomeric excess ee (1)
- Encapsulation (1)
- Encoding (1)
- Endokriner Disruptor (1)
- Enhancement strategy (1)
- Environment (1)
- Environmental Engineering (1)
- Environmental pollutants (1)
- Environmental simulations (1)
- Environmental speciation (1)
- Enzyme (1)
- Enzyme-Linked Immunosorbent Assay (1)
- Equation of state (1)
- Error correction (1)
- Escherichia coli (1)
- Esterification (1)
- Estrogens (1)
- Ethylenediaminetetraacetic acid (1)
- Etofenprox (1)
- European Reference Material (1)
- Evanescent wave (1)
- Ex vivo (1)
- Excimers (1)
- Excitation (1)
- Exhaust (1)
- Experiment (1)
- Explosiven (1)
- Explosives detection (1)
- Exposure (1)
- Extractable organically bound fluorine (EOF) (1)
- Extraction (1)
- FFF-3D printer (1)
- FFF-3D printing (1)
- FRET (1)
- False Positives (1)
- Feature selection (1)
- Fenton (1)
- Fenton’s reagent (1)
- Finow Canal (1)
- Flexible crystals (1)
- Flourescence (1)
- Flourescin (1)
- Flow injection immunoassay (1)
- Fluorescein (1)
- Fluorescence Polarization (1)
- Fluorescence label (1)
- Fluorescence life time (1)
- Fluorescence spectroscopy (1)
- Fluorescence standard (1)
- Fluorescent dyes (1)
- Fluorescent probes (1)
- Fluorescent sensors (1)
- Fluoreszenz (1)
- Fluorides (1)
- Fluorination (1)
- Fluoroacetic acid (1)
- Fluorophilic interactions (1)
- Folding chirality (1)
- Food fermentation (1)
- Food safety (1)
- Forsterite (1)
- Fourier transform spectroscopy (1)
- Fow injection analysis (1)
- Fragmentation pathway (1)
- Freisetzung (1)
- Fully aromatic frameworks (1)
- Functional group quantification (1)
- Functional monomers (1)
- Fungicide (1)
- Funtional Groups (1)
- Fusarium (1)
- Fusarium mycotoxin (1)
- GC/MS (1)
- GC/MS-MS (1)
- GF-MAS (1)
- GMAW (1)
- Gadolinium-based contrast agent (1)
- Gadovist (1)
- Galvanic anodes (1)
- Gamma-hydroxybutyric acid (1)
- Gas analysis (1)
- Gas sensing (1)
- Gasoline (1)
- Gated materials (1)
- Gd-DOTA (1)
- General Chemistry (1)
- Genotoxicity testing (1)
- Geological material (1)
- Germanium chlorides (1)
- Gesteuerte Freisetzung (1)
- Gesteuerten Nanopartikeln (1)
- Ggadolinium (1)
- Github (1)
- Glasmonolith (1)
- Glass (1)
- Glass Support (1)
- Gold (1)
- Gold nanocluster (1)
- Grafting (1)
- Graphene (1)
- Graphite furnace (1)
- Grass pollen (1)
- Green light excitation (1)
- Grignard reaction (1)
- Grignard-Reaktion (1)
- Ground water (1)
- Groundwater (1)
- Group profile (1)
- Guanidinium receptors (1)
- Gypsum (1)
- Gypsum dehydration (1)
- HAXPES (1)
- HF free Digestion (1)
- HPLC-DAD/FLD (1)
- HPSEC (1)
- HR-CS-MAS (1)
- Hafnium (1)
- Hapten Immunoassay (1)
- Hay fever (1)
- Heart attack (1)
- Heat accumulation (1)
- Heat flow (1)
- Heat-transfer Measurements (1)
- Heavy chains (1)
- Hemihydrate (1)
- Hepatocellular carcinoma (1)
- Herceptin (1)
- HexaHis-Tag (1)
- High entropy alloy (1)
- High pH (1)
- High pressure experiments (1)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (1)
- High-Speed (1)
- High-Speed Separations (1)
- High-fired gypsum (1)
- High-fired gypsum mortar (1)
- High-fired medieval gypsum mortars (1)
- High-frequency arc discharge (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- High-resolution continuum source molecular absorption spectrometry (1)
- High-throughput (1)
- Highspeed (1)
- His6 (1)
- His8 (1)
- Histidine (1)
- Hot-electrons (1)
- Human Plasma (1)
- Human leukocyte antigen (HLA) (1)
- Human papillomavirus (1)
- Human serum albumin (1)
- Humic matter (1)
- Hydrated silicate melts (1)
- Hydration (1)
- Hydrochloric acid (1)
- Hydrodynamic chromatography (HDC) (1)
- Hydrodynamic model (1)
- Hydrogen Storage (1)
- Hydrogen adsorption (1)
- Hydrogen adsorption storage (1)
- Hydrogen reduction (1)
- Hydrogen uptake reproducibility (1)
- Hydrogen-containing gas mixture (1)
- Hydrogenasen (1)
- Hydrothermal fluid (1)
- Hydroxy warfarin (1)
- ICP-MS/MS (1)
- ICP-TOFMS (1)
- ICP-ToF-MS (1)
- ID-MS (1)
- ILC (1)
- IMAC purification (1)
- IR spectroscopy; conductometry (1)
- ISO REMCO (1)
- Identity (1)
- IgE (1)
- IgG determination (1)
- IgY (1)
- Illicit drug (1)
- Image analysis (1)
- Image segmentation (1)
- Imaging Technique (1)
- Imidazole (1)
- Immobilisierung (1)
- Immunassay (1)
- Immunglobulin (1)
- Immunglobuline (1)
- Immunoassays (1)
- Immunoglobulin E (1)
- Immunohistochemistry (1)
- Immunology (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Impact (1)
- Imprinting (1)
- Impurites (1)
- In situ (1)
- In situ EXAFS (1)
- In situ SAXS/WAXS (1)
- In situ measurement (1)
- In vivo (1)
- In-house calibration solution (1)
- In-situ analysis (1)
- In-situ process monitoring (1)
- In-vivo (1)
- Indicator displacement assay (1)
- Indoor air quality (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inductively coupled plasma mass spectroscopy (1)
- Inductively‑coupled mass spectrometry (1)
- Industrial gypsum (1)
- Inert gases (1)
- Infrared thermography (1)
- Infrastruktur (1)
- Inhibition (1)
- Inline Analytics (1)
- Inorganic chemical analysis (1)
- Inorganic impurities (1)
- Instrumental isotope fractionation (1)
- Inter layer time (1)
- Interferometric spectroscopy (1)
- Intermixing (1)
- Internal standard (1)
- International drug trade (1)
- Ion mobility spectrometry (1)
- Ionophore (1)
- Ionophore antibiotics (1)
- Iposomes (1)
- Iridium (1)
- Isotope Dilution (1)
- Isotope Labelling (1)
- Isotope amount ratio (1)
- Isotope delta value (1)
- Isotope dilution mass spectrometry (1)
- Isotope reference material (1)
- Isotope-labeled (1)
- Isotopic analysis (1)
- Isotopic fractionation (1)
- Isotopologue Distribution (1)
- Iterative real-time optimization (1)
- Jahrestag (1)
- Job plot (1)
- Kjeldahl (1)
- Knowledge graphs (1)
- Kompost (1)
- LA/ICP-MS Imaging (1)
- LC-MS (1)
- LC-UV absorbance (1)
- LC/HRMS (1)
- LC/MS-MS (1)
- LFIA (1)
- LSVEC (1)
- Lab on a chip (1)
- Lab-on-a-Chip (1)
- Laboratory 4.0 (1)
- Lacunary Keggin ion (1)
- Ladder sequencing (1)
- Lasalocid (1)
- Laser Ablation (1)
- Laser ablation-inductively coupled plasma-mass spectrometry (1)
- Laser ablation-inductively coupled plasma-mass spectroscopy (1)
- Laser induced breakdown Spectrocopy (LIBS) (1)
- Laser induced breakdown spectroscopy (1)
- Laser induced plasma (1)
- Laser induced plasma deposition (1)
- Laser powder bed fusion (1)
- Laser-induced breakdown spectroscopy (1)
- Laser-induced dielectric breakdown (LIDB) (1)
- Laser-induced fluorescence (1)
- Lastwechsel (1)
- Layer-by-Layer (1)
- Layers (1)
- Leaching (1)
- Lead (1)
- Legacy pollution (1)
- LiYF4 (1)
- Library (1)
- Life science (1)
- Lifetime encoding (1)
- Lifetime-encoded beads (1)
- Light chain (1)
- Light chains (1)
- Light harvesting (1)
- Lipidomics (1)
- Lipids (1)
- Liquid chromatography (1)
- Liver X receptor (1)
- Lluminescence (1)
- Longst luminescence lifetime (1)
- Low-cost (1)
- Low-energy electrons (1)
- Luminescent lifetime (1)
- Luminol (1)
- Lymnaea stagnalis (1)
- Lysergic acid hydrazide (1)
- Lysosome (1)
- MALDI-TOF-MS (1)
- MC-TIMS (1)
- MCR (1)
- MIC (1)
- MICAP-MS (1)
- MIP (1)
- MLCT (1)
- MOF´s (1)
- MOSH/MOAH (1)
- MR Angiography (1)
- MR imaging (1)
- MST (1)
- MW-AES (1)
- MYCN (1)
- Machine learning (1)
- Macrophages (1)
- Magnesium (1)
- Magnesium carbonates (1)
- Magnetic (1)
- Magnetic nanocatalyst (1)
- Magnetpartikel (1)
- Mass-Spectrometry (1)
- Massenspektrometrie (1)
- Material sciences (1)
- Materials informatics (1)
- Mechanical properties (1)
- Medical diagnostics (1)
- Medicinal application (1)
- Medicine (1)
- Medium entropy alloy (1)
- MefHySto (1)
- Mercury speciation (1)
- Meso Portland cement (1)
- Mesofluidics (1)
- Mesoporous particles (1)
- Metabolic Flux (1)
- Metabolization (1)
- Metal cluster (1)
- Metal toxicity (1)
- Metal uptake (1)
- Metalloprotein (1)
- Metals (1)
- Metal−organic frameworks (1)
- Methanol oxidation (1)
- Methylanilines (1)
- Methylmercury (1)
- Metrologie (1)
- Metrology in chemistry (1)
- Microbe interactions (1)
- Microbially Induced Corrosion (1)
- Microfluidic (1)
- Microfluidic mixing (1)
- Microfluidic system (1)
- Micrometeorites (1)
- Microorganism (1)
- Microplastic-induced effects (1)
- Microplatic (1)
- Microscope slides (1)
- Microwave inductively coupled atmospheric pressure mass spectrometry (MICAP-MS) (1)
- Microwave-assisted synthesis (1)
- Miller and Urey (1)
- Mineral identification (1)
- Mineral oil hydrocarobons (1)
- Mineral paragenesis (1)
- Miniaturization (1)
- Missing fragmentation sites (1)
- Mixed surface (1)
- Mixture toxicity (1)
- Mobile analytics (1)
- Mobile phase (1)
- Model Predictive Control (1)
- Modeling (1)
- Modified mycotoxins (1)
- Modifier adaptation (1)
- Molecular Biology (1)
- Molecular MRI (1)
- Molecular Organic Frameworks (1)
- Molecular imprinted polymers (1)
- Molecular marker (1)
- Molecular spectra (1)
- Molecular-MRI (1)
- Molecule (1)
- Monensin (1)
- Monoclonal Antibody (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Monomer (1)
- Monte Carlo algorithm (1)
- Mounting media (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multi-element analysis (1)
- Multi-prinicpal element alloys (MPEAs) (1)
- Multiple sclerosis (1)
- Multiple-injection sample-standard bracketing (1)
- Multiplexed assay (1)
- Multivariat (1)
- Multivariate (1)
- Multivariate data analysis (1)
- Multivariate methods (1)
- Murchison meteorite (1)
- NIR Spectroscopy (1)
- NIR dyes (1)
- NIR-I (1)
- NIR-II fluorescence (1)
- NIST (1)
- NIST-mAb 8671 (1)
- NMR Spectroscopy (1)
- NMR spectroscopy (1)
- NMR-Spektroskopie (1)
- NSE (1)
- Nanaoparticle (1)
- Nanaoparticles (1)
- Nano-carrier (1)
- Nanocarrier (1)
- Nanolenses (1)
- Nanomaterial design (1)
- Nanoparticle characterization (1)
- Nanoparticle dimers (1)
- Nanopartikel (1)
- Nanopowder (1)
- Nanosafety (Safe-by-design) (1)
- Nanoscience (1)
- Nanosciences (1)
- Nanostructures (1)
- Naphthalene (Nap) (1)
- Narcotics (1)
- Neoallergen (1)
- Neoepitopes (1)
- Neural networks (1)
- Neutral dyes (1)
- Nickel chelate (1)
- Nile Red (1)
- Nitrogen dioxide (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Nitrogen monoxide (1)
- Nitrogen plasma (1)
- Non-targeted analysis (1)
- Nonspecific binding (NSB) (1)
- Nuclear Magnetic Resonance Spectroscopy (1)
- Nuclear receptor (1)
- Nucleocapsid (1)
- OBOC library (1)
- Ochratoxin A (1)
- Oil spills (1)
- Oligomerization (1)
- Oligonucleotides (1)
- On-chip screening (1)
- On-line CE/MC-ICP-MS (1)
- On-site detection (1)
- One-bead-one-compound library (1)
- Online NMR Spectroscopy (1)
- Online NMR spectroscopy (1)
- Online biosensor (1)
- Online detection (1)
- Ontologies (1)
- Open science (1)
- Optical assay (1)
- Optical imaging (1)
- Optically active surfaces (1)
- Orbitrap (1)
- Organic Synthesis (1)
- Organic calibration solution (1)
- Organic contaminants (1)
- Organic-inorganic hybrid composites (1)
- Organic–inorganic nanostructures (1)
- Oriented immobilization (1)
- Osmotic minipumps (1)
- Oxidative metabolism (1)
- Oxygen evolution reaction (1)
- Oxygen isotope ratios (1)
- Oxygen sensitive (1)
- PAHs (1)
- PCA (1)
- PDT (1)
- PEM-Wasserelektrolyse (1)
- PIC technology (1)
- PLSR (1)
- PSA (1)
- Packing density (1)
- Pants (1)
- Partial least square discriminant analysis (PLS-DA) (1)
- Particle architecture (1)
- Particle synthesis (1)
- Pattern recognition receptor (1)
- Pd(II) (1)
- Peer review (1)
- Peptide aptamers (1)
- Peptide binder (1)
- Peptide folding (1)
- Peptide mass fingerprinting (1)
- Peptide probe (1)
- Peptides (1)
- Peptides and Proteins (1)
- Per- and Polyfluoroalkyl substances (PFAS) (1)
- Per- and polyfluorinated alkyl substances (PFASs) (1)
- Perfluorooctanoic Acid (PFOA) (1)
- Permethrin (1)
- Peroxidase (1)
- Perturbed-Chain Statistical Association Fluid Theory (1)
- Pesticide (1)
- Pestizid (1)
- Petroleum (1)
- Pflanzenvirus (1)
- Pflanzenwachstum (1)
- Ph (1)
- Pharmaceutical (1)
- Pharmaceutical Science (1)
- Phase Imaging (1)
- Phenanthrene (1)
- Phenothrin (1)
- Phenylketonuria (1)
- Phl p 5 (1)
- Phleum pratense (1)
- Phosphinine (1)
- Phospholipids (1)
- Phosphor (1)
- Phosphorescence (1)
- Phosphorus elimination (1)
- Phosphorus recovery (1)
- Photocatalysis (1)
- Photocatalytic reduction (1)
- Photochemistry (1)
- Photoinduced Electron Transfer (1)
- Photoinduced electron transfer (1)
- Photonic biosensor (1)
- Photosensitization (1)
- Photostability (1)
- Physical and theoretical chemistry (1)
- Physical twin (1)
- Physico-chemical characterisation of minerals (1)
- Phytoliths (1)
- Planck function (1)
- Plant virus (1)
- Plant-model mismatch (1)
- Plasma (1)
- Plasma chemistry (1)
- Plasmonic heating (1)
- Plastic deformation (1)
- Polarised light microscopy (1)
- Polarity (1)
- Polishing (1)
- Pollen (1)
- Pollen extract (1)
- Pollutant (1)
- Polyclonal Antibodies (1)
- Polycyclic aromatic hydrocarbons (1)
- Polyelektrolyt (1)
- Polyglycerol (1)
- Polymer particles (1)
- Polymer-based products (1)
- Polymere (1)
- Polymerization (1)
- Polymers (1)
- Polyoxometalates (1)
- Polystyrene microparticles (1)
- Pore fluids (1)
- Porous rock (1)
- Porphyrin (1)
- Portable (1)
- Portland clinker (1)
- Potash (1)
- Powder X-ray diffraction (1)
- Power density (1)
- Pphotophysics (1)
- Prebiotic chemistry (1)
- Precision agriculture (1)
- Precision farming (1)
- Preprocessing (1)
- Primary difference measurement method (PDM) (1)
- Primary transfer standards (PTSs) (1)
- Primordial soup (1)
- Principal component analysis (PCA) (1)
- Priority effect (1)
- Process Analytical Tecnology (1)
- Process Control (1)
- Process control (1)
- Process industry (1)
- Process intelligence (1)
- Process monitoring (1)
- Process sensors 4.0 (1)
- Programmed cell death (1)
- Proinflammatory cytokines (1)
- Protein Purification (1)
- Protein content (1)
- Protein degradation (1)
- Protein folding (1)
- Protein hydrolysis (1)
- Protein oligomerization (1)
- Protein oligomers (1)
- Protein quantification (1)
- Protein test (1)
- Protein-modification (1)
- Proteinoid (1)
- Prouess-Sensoren 4.0 (1)
- Provenance (1)
- Provenancing (1)
- Proximal soil sensing (1)
- Prozessanalytik (1)
- Prozesskontrolle (1)
- Pseudomonas aeruginosa (1)
- Pt(111) (1)
- Pt(II) (1)
- PtNP (1)
- Public Health, Environmental and Occupational Health (1)
- Purity (1)
- Quality assurancemechanism (1)
- Quantitative Analysis (1)
- Quantitative determination (1)
- Quantitative protein analysis (1)
- Quantum chemistry (1)
- Quartz (1)
- R package (1)
- RBD (1)
- REMPI (1)
- Racemate (1)
- Rainwater (1)
- Raman band width (1)
- Raman microscopy (1)
- Raman-spectroscopy (1)
- Rapid test (1)
- Rapid tests (1)
- Rat/human liver microsomes (1)
- Ratiometric (1)
- Reactor control (1)
- Real-time imaging (1)
- Real-time quality control (1)
- Recombinant Antibody (1)
- Recombinant antibody (1)
- Recombinant protein (1)
- Redox (1)
- Redox switch (1)
- Reference (1)
- Reference Material (1)
- Reference Materials (1)
- Reference data (1)
- References (1)
- Reinigung (1)
- Reliability (1)
- Remediation (1)
- Renal disease (1)
- Renewable copolymers (1)
- Replication (1)
- Replication crisis (1)
- Reporter (1)
- Reproducibility crisis (1)
- Resistance (1)
- Resonance wavelength shift (1)
- Reverse microemulsion (1)
- Reversible covalent hydrazine chemistry (RCHC) (1)
- Rheumatoid arthritis (1)
- Rhizopus (1)
- Rhizopus and Aspergillus oryzae (1)
- Rhodamine (1)
- Ring resonator (1)
- River water sulfate (1)
- Robustness (1)
- Rosamine (1)
- Roughness (1)
- Ruthenium(II) complexes (1)
- Rückverstromung (1)
- SA conjugates (1)
- SAXS (1)
- SBA-15 (1)
- SBA-16 (1)
- SEC (1)
- SEM (1)
- SERDS (1)
- SERS (1)
- SI Traceability (1)
- SIDA-LC-MS/MS (1)
- SKPFM (1)
- SOM-SM (1)
- SPR (1)
- SVOC (1)
- Safe by design (1)
- Salicylic acid (1)
- Salinomycin (1)
- Salts (1)
- Sample preparation (1)
- Scale anchor (1)
- Scale conversion (1)
- Scattering (1)
- Schlangenbohne (1)
- Schlieren Imaging (1)
- Schnelltest (1)
- Schnelltests (1)
- Scientific publication (1)
- Seawater (1)
- Security (1)
- Sediment (1)
- Segregation (1)
- Selenium (1)
- Self-absorption (1)
- Self-assembled monolayers (SAM) (1)
- Semiconductor (1)
- Semiconductor nanocrystals (1)
- Semiconductor quantum dot (1)
- Sensor Materials (1)
- Sensory particles (1)
- Separation (1)
- Sequence dependence (1)
- Sequencing (1)
- Sequencing algorithm (1)
- Shadowgraphy (1)
- Silanization (1)
- Silica and polystyrene nanoparticles (1)
- Silica coating (1)
- Silica diagenesis (1)
- Silicon (1)
- Silicon chlorides (1)
- Silicon isotopes (1)
- Simulation (1)
- Single Cell (1)
- Single enhancement (1)
- Single particle ICP-MS (1)
- Single-cell analysis (1)
- Singlet oxygen (1)
- Sintered Material (1)
- Small-angle scattering (1)
- Smart actuators (1)
- Smart test laboratories (1)
- Smarte Aktoren (1)
- Smarte Sensoren (1)
- Smarter Sensor (1)
- Smartphone readout (1)
- Soil contact (1)
- Soil heterogeneity (1)
- Sol-gel process (1)
- Solar cells (1)
- Solar concentrator (1)
- Solar energy (1)
- Solid (1)
- Solid state (1)
- Solid state emission (1)
- Solid support (1)
- Solid-phase extraction (SPE) (1)
- Sorghum (1)
- Spark plasma sintering (1)
- Spatial heterodyne spectrometer (1)
- Special issue (1)
- Specific probe (1)
- Spectoscopic imaging (1)
- Spectrometer (1)
- Spectrometry (1)
- Spectroscopic imaging (1)
- Spectroscopy / Instrumentation (1)
- Spectroscopy / Theory (1)
- Speed of sound (1)
- Spike protein (1)
- Sr isotope analysis (1)
- SsNMR (1)
- Stability (1)
- Stabilization (1)
- Stable isotopes (1)
- Standard atomic weight (1)
- Stationäre Phase (1)
- Statistics (1)
- Steel (1)
- Stepwise growth (1)
- Stranski–Krastanow growth (1)
- Strontium isotope (1)
- Structural Biology (1)
- Structure-property relationship (1)
- Sub-4nm particles (1)
- Substance release (1)
- Sulfide sensing (1)
- Sulfur (1)
- Sulfur isotopes (1)
- Sulphur isotope (1)
- Sum Parameter (1)
- Sum Parameter Method (1)
- Sum parameter method (1)
- Supported catalyst (1)
- Supramolecular Chemistry (1)
- Surface Chemistry (1)
- Surface coating (1)
- Surface derivatization (1)
- Surface ligand (1)
- Surface plasmon resonance (1)
- Surface waters (1)
- Surface-enhanced Raman scattering (1)
- Surrogate citations (1)
- Sustainable Production (1)
- Suzuki coupling (1)
- Suzuki-Miyaura coupling (1)
- Swell-capture (1)
- Synchrotron FTIR (1)
- TEM (1)
- TFA (1)
- TLR4 activation (1)
- Tantalum oxyfluorides (1)
- Target (1)
- Tau (1)
- Temperature (1)
- Temperature Control (1)
- Terephthalic acid (1)
- Terrorism (1)
- Test strip (1)
- Tetracyclin (1)
- Tetramethylammonium hydroxide (1)
- Theranostic (1)
- Therapeutic Antibodies (1)
- Thermal Process Engineering (1)
- Thermocouple (1)
- Thermodynamic analysis (1)
- Thermography (1)
- Thick shells (1)
- Thickness (1)
- Thin films (1)
- Tholins (1)
- Tissue (1)
- Titan-Halterung (1)
- Titanium dioxide (1)
- ToF-SIMS (1)
- Toll-like receptor 4 (1)
- Tomography (1)
- Topical collection: Analytical Methods and Applications in the Materials and Life Sciences (1)
- Total cyanide (1)
- Total element determination (1)
- Toxicity testing (1)
- Toys (1)
- Trace Analysis (1)
- Transferrin (1)
- Transformation (1)
- Transient signal (1)
- Transpassive dissolution (1)
- Trastuzumab (1)
- Trennung (1)
- Truffle (1)
- Truffle Aroma (1)
- Trust (1)
- Tryptic digest (1)
- Tryptophan (1)
- Tuber melanosporum (1)
- Tutzing Symposion (1)
- Type-I pyrethroids (1)
- UV Vis (1)
- UV radiation (1)
- UV–Vis spectroscopy (1)
- Ultrasensitive (1)
- Umweltschadstoffe (1)
- Upconverion (1)
- Upconverstion (1)
- Upscaling (1)
- VO (1)
- VVOC (1)
- Validate method (1)
- Validation trial (1)
- Vanadium (1)
- Vanadium oxide catalysts (1)
- Vegetable edible oil (1)
- Veterinary drugs (1)
- Vigna unguiculata (1)
- Virial coefficients (1)
- Visualization (1)
- Vocabulary providers (1)
- Volatile organic compounds (1)
- Volatile organic compounds; (1)
- Volumetric uptake (1)
- Vor-Ort-Analytik (1)
- WD-XRF (1)
- WWTP (1)
- Warfarin (1)
- Wasserstoff (1)
- Wasserstoff-Qualität (1)
- Wasserstoffspeicher (1)
- Wastewater (1)
- Water (1)
- Water contact (1)
- Whole water samples (1)
- Wipe test (1)
- Wood chips (1)
- Work function (1)
- X-Ray analysis (1)
- X-Ray fluorescence (1)
- X-ray (1)
- X-ray diffraction (1)
- X-ray spectroscopy (1)
- XANES (1)
- YES assay (1)
- Yerba mate tea (1)
- Ytterbium (1)
- Zearalenone (1)
- Zearalenone sulfate (1)
- Zellulose (1)
- Zenodo (1)
- Zeolithe (1)
- Zinc (1)
- Zinc oxide (1)
- a-zearalenol (1)
- biokompatibel (1)
- calibration (1)
- compost (1)
- dye (1)
- gesintert (1)
- lank characterization (1)
- magnetic nanocatalysts (1)
- pH probe (1)
- photoluminescence (1)
- research landscape (1)
- self-replication (1)
- spICP-MS (1)
- species-specific isotope information (1)
- tandard addition (1)
- temperature (1)
- thermophysical properties (1)
- transmission mode (1)
- β-Lactam (1)
- γ-H2AX assay (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (361) (entfernen)
Paper des Monats
- ja (11)
The 2023 Nobel Prize in Chemistry was awarded to Aleksey I. Ekimov (prize share 1/3), Louis E. Brus (prize share 1/3), and Moungi G. Bawendi (prize share 1/3) for groundbreaking inventions in the field of nanotechnology, i.e., for the discovery and synthesis of semiconductor nanocrystals, also termed quantum dots, that exhibit size-dependent physicochemical properties enabled by quantum size effects. This feature article summarizes the main milestones of the discoveries and developments of quantum dots that paved the road to their versatile applications in solid-state lighting, display technology, energy conversion, medical diagnostics, bioimaging, and image-guided surgery.
Four donor-acceptor boron difluoride complexes based on the carbazole electron donor and the [1,3,5,2]oxadiazaborinino[3,4-a][1,8]naphthyridine acceptor were designed, synthesized, and systematically spectroscopically investigated in solutions, in the solid states, and dye-doped polymer films. The dyes exhibit an intense blue to red solid-state emission with photoluminescence quantum yields of up to 56% in pure dye samples and 86% in poly(methyl methacrylate) films. All boron complexes show aggregation-induced emission and reversible mechanofluorochromism. The optical properties of these dyes and their solid state luminescence can be tuned by substitution pattern, i.e., the substituents at the naphthyridine unit. Exchange of CH3- for CF3-groups does not only increase the intramolecular charge transfer character, but also provides a crystallization-induced emission enhancement.
With the reduction of large oil spills because of stricter regulations and safety measures, the question of how to manage smaller oil spills arises. Few on-site analytical tools are available for first responders or other law enforcement personnel to rapidly test for crude oil in the early management of localized polluted areas. The approach reported here relies on well-described computer-assisted multivariate data analysis of the intrinsic fluorescence fingerprints of crude oils to build a multivariate model for the rapid classification of crude oils and the prediction of their properties. Thanks to a dedicated robust portable reader, the method allowed classification and accurate prediction of various properties of crude oil samples like density (according to API, the American Petroleum Institute and viscosity as well as composition parameters such as volume fractions of paraffins or aromatics. In this way, autonomous operation in on-site or in-the-field applications becomes possible based on the direct (undiluted and untreated) measurement of samples and a rapid, tablet-operated readout system to yield a robust and simple analytical test with superior performance. Testing in real-life scenarios allowed the successful classification and prediction of a number of oil spill samples as well as weathered samples that closely resemble samples collected by first responders.
AbstractSince the 1950s, Warfarin has been used globally as both a prescription drug and a rodenticide. Research has shown that warfarin and other rodenticides are present in the environment and food chain. However, emerging contaminants are subject to degradation by biotic and abiotic processes and advanced oxidation processes. In some cases, detecting the parent compound may not be possible due to the formation of structurally changed species. This approach aims to identify hydroxylated transformation products of warfarin in a laboratory setting, even after the parent compound has undergone degradation. Therefore, the Fenton reaction is utilized to insert hydroxylation into the parent compound, warfarin, by hydroxyl and hydroperoxyl radicals generated by Fe2+/Fe3+ redox reaction with hydrogen peroxide. Using multiple reaction monitoring, a GC–MS/MS method, incorporating isotopically labeled reference compounds, is used to quantify the expected derivatized species. The analytes are derivatized using trimethyl-3-trifluoromethyl phenyl ammonium hydroxide, and the derivatization yield of warfarin is determined by using isotopically labeled reference compounds. The method has a linear working range of 30 to 1800 ng/mL, with detection limits ranging from 18.7 to 67.0 ng/mL. The analytes are enriched using a C18-SPE step, and the recovery for each compound is calculated. The Fenton reaction generates all preselected hydroxylated transformation products of warfarin. The method successfully identifies that 4′-Me-O-WAR forms preferentially under the specified experimental conditions. By further optimizing the SPE clean-up procedures, this GC–MS-based method will be suitable for detecting transformation products in more complex matrices, such as environmental water samples. Overall, this study provides a better understanding of warfarin’s degradation and offers a robust analytical tool for investigating its transformation products.
The processes of hydrogen reduction of silicon and germanium chlorides under the conditions of high-frequency (40.68 MHz) counteracted arc discharge stabilized between two rod electrodes are investigated. The main gas-phase and solid products of plasma-chemical transformations are determined. Thermodynamic analysis of SiCl4 + H2 and GeCl4 + H2 systems for optimal process parameters was carried out. Using the example of hydrogen reduction of SiCl4 by the method of numerical modeling, gas-dynamic and thermal processes for this type of discharge are investigated. The impurity composition of gas-phase and solid reaction products is investigated. The possibility of single-stage production of high-purity Si and Ge mainly in the form of compact ingots, as well as high-purity chlorosilanes and trichlorogermane, is shown.
Luminescence lifetimes are an attractive analytical method for detection due to its high sensitivity and stability. Iridium probes exhibit luminescence with long excited-state lifetimes, which are sensitive to the local environment. Perfluorooctanoic acid (PFOA) is listed as a chemical of high concern regarding its toxicity and is classified as a “forever chemical”. In addition to strict limits on the presence of PFOA in drinking water, environmental contamination from industrial effluent or chemical spills requires rapid, simple, accurate, and cost-effective analysis in order to aid containment. Herein, we report the fabrication and function of a novel and facile luminescence sensor for PFOA based on iridium modified on gold surfaces. These surfaces were modified with lipophilic iridium complexes bearing alkyl chains, namely, IrC6 and IrC12, and Zonyl-FSA surfactant. Upon addition of PFOA, the modified surfaces IrC6-FSA@Au and IrC12-FSA @Au show the largest change in the red luminescence signal with changes in the luminescence lifetime that allow monitoring of PFOA concentrations in aqueous solutions. The platform was tested for the measurement of PFOA in aqueous samples spiked with known concentrations of PFOA and demonstrated the capacity to determine PFOA at concentrations >100 μg/L (240 nM).
Reliable measurement of the size of polydisperse, complex-shaped commercial nanopowders is a difficult but necessary task, e.g., for regulatory requirements and toxicity risk assessment. Suitable methods exist for the accurate characterization of the size of non-aggregated, stabilized, spherical and monodisperse nanoparticles. In contrast, industrial nanoscale powders usually require dedicated sample preparation procedures developed for the analysis method of choice. These nano-powders tend to agglomerate and/or aggregate, a behavior which in combination with an innate broad particle size distribution and irregular shape often significantly alters the achievable accuracy of the measured size parameters. The present study systematically tests two commercially available nanoscale powders using different sample preparation methods for correlative analysis by scanning electron microscopy, dynamic light scattering, Brunauer–Emmet–Teller method and differential mobility analysis. One focus was set on the sample preparation by embedding nanoparticles in carbon-based hot-mounting resin. Literature on this topic is scarce and the accuracy of the data extracted from cross sections of these particles is unclearly stated. In this paper systematic simulations on the deviation of the size parameters of well-defined series of nanoparticles with different shapes from the nominal value were carried out and the contributing factors are discussed.
This contribution reports the development of a polymerizable BODIPY-type fluorescent probe targeting small-molecule carboxylates for incorporation into molecularly imprinted polymers (MIPs). The design of the probe crosslinker includes a urea recognition site p-conjugated to the 3-position of the BODIPY core and two methacrylate moieties. Titration experiments with a carboxylate-expressing antibiotic, levofloxacin (LEVO), showed a blue shift of the absorption band as well as a broadening and decrease in emission, attributed to hydrogen bonding between the probe’s urea group and the carboxylate group of the antibiotic. Using this probe crosslinker, core–shell particles with a silica core and a thin MIP shell were prepared for the detection of LEVO. The MIP exhibited highly selective recognition of LEVO, with an imprinting factor of 18.1 compared to the non-imprinted polymer. Transmission electron microscopy confirmed the core–shell structure and spectroscopic studies revealed that the receptor’s positioning leads to a unique perturbation of the polymethinic character of the BODIPY chromophore, entailing the favourable responses. These features are fully preserved in the MIP, whereas no such response was observed for competitors such as ampicillin. The sensory particles allowed to detect LEVO down to submicromolar concentrations in dioxane. We have developed here for the first time a BODIPY probe for organic carboxylates and incorporated it into polymers using the imprinting technique, paving the way for BODIPY-type fluorescent MIP sensors.
Multi-principal element alloys (MPEAs) are gaining interest in corrosion and electrocatalysis research due to their electrochemical stability across a broad pH range and the design flexibility they offer. Using the equimolar CrCoNi alloy, we observe significant metal dissolution in a corrosive electrolyte (0.1 M NaCl, pH 2) concurrently with the oxygen evolution reaction (OER) in the transpassive region despite the absence of hysteresis in polarization curves or other obvious corrosion indicators. We present a characterization scheme to delineate the contribution of OER and alloy dissolution, using scanning electrochemical microscopy (SECM) for OER-onset detection, and quantitative chemical analysis with inductively coupled-mass spectrometry (ICP-MS) and ultraviolet visible light (UV-Vis) spectroscopy to elucidate metal dissolution processes. In-situ electrochemical atomic force microscopy (EC-AFM) revealed that the transpassive metal dissolution on CrCoNi is dominated by intergranular corrosion. These results have significant implications for the stability of MPEAs in corrosion systems, emphasizing the necessity of analytically determining metal ions released from MPEA electrodes into the electrolyte when evaluating Faradaic efficiencies of OER catalysts. The release of transition metal ions not only reduces the Faradaic efficiency of electrolyzers but may also cause poisoning and degradation of membranes in electrochemical reactors.
In situ chemical analysis of duplex stainless steel weld by laser induced breakdown spectroscopy
(2024)
The high corrosion resistance and good mechanical properties of duplex stainless steel (DSS) are due to its special chemical composition, which is a balanced phase ratio of ferrite (α) and austenite (γ). Many industrial applications require the integration of DSS components. For this, Gas tungsten arc welding (GTAW) is an excellent choice, as it allows an automated operation with high reproducibility. However, when the weld pool solidifies, critical ratios of α- and γ- phases can occur, which lead to solidification cracking, increased susceptibility to corrosion, and a decrease in ductility and critical strength. Previous studies have shown that these defects can be caused by the accumulation of manganese and chromium in the heat affected zone (HAZ), requiring ongoing monitoring of this accumulation. A suitable method for such monitoring is laser-induced breakdown spectroscopy (LIBS), which can be used in two operating modes: calibration using standard reference samples and calibration-free. Unlike conventional quantitative LIBS measurements, which require reference samples to generate a calibration curve, calibration-free LIBS (CF-LIBS) allows chemical compositions to be determined solely from the emission spectrum of the plasma. Numerous publications show that CF-LIBS is a fast and efficient analytical method for the quantitative analysis of metal samples. In this work, CF-LIBS is applied to spectra obtained during GTAW DSS welding and the result is compared with those obtained by PLS analysis. A good correlation was found between both types of analysis, demonstrating the suitability of the CF-LIBS method for this application. The CF-LIBS method has a significant advantage over conventional LIBS due to the rapid in situ measurement of concentrations of major alloying elements without calibration procedure. This, combined with fast feedback and appropriate adjustment of welding parameters, helps prevent welding defects.
On-line coupled high performance liquid chromatography-gas chromatography-flame ionisation detection (HPLC-GC-FID) was used to compare the effect of hydrogen, helium and nitrogen as carrier gases on the chromatographic characteristics for the quantification of mineral oil hydrocarbon (MOH) traces in food related matrices. After optimisation of chromatographic parameters nitrogen carrier gas exhibited characteristics equivalent to hydrogen and helium regarding requirements set by current guidelines and standardisation such as linear range, quantification limit and carry over. Though nitrogen expectedly led to greater peak widths, all required separations of standard compounds were sufficient and humps of saturated mineral oil hydrocarbons (MOSH) and aromatic mineral oil hydrocarbons (MOAH) were appropriate to enable quantitation similar to situations where hydrogen or helium had been used. Slightly increased peak widths of individual hump components did not affect shapes and widths of the MOSH and MOAH humps were not significantly affected by the use of nitrogen as carrier gas. Notably, nitrogen carrier gas led to less solvent peak tailing and smaller baseline offset. Overall, nitrogen may be regarded as viable alternative to hydrogen or helium and may even extend the range of quantifiable compounds to highly volatile hydrocarbon eluting directly after the solvent peak.
Amphiphilic nanogels (ANGs) are promising carriers for hydrophobic cargos such as drugs, dyes, and catalysts.
Loading content and release kinetics of these compounds are controlled by type and number of hydrophobic groups in the amphiphilic copolymer network. Thus, understanding the interactions between cargo and colloidal carrier is mandatory for a tailor-made and cargo-specific ANG design. To systematically explore the influence of the network composition on these interactions, we prepared a set of ANGs of different amphiphilicity and loaded these ANGs with varying concentrations of the solvatochromic dye Nile Red (NR). Here, NR acts as a hydrophobic model cargo to optically probe the polarity of its microenvironment. Analysis of the NR emission spectra as well as measurements of the fluorescence quantum yields and decay kinetics revealed a decrease in the polarity of the NR microenvironment with increasing hydrophobicity of the hydrophobic groups in the ANG network and dye–dye interactions at higher loading concentrations. At low NR concentrations, the hydrophobic cargo NR is encapsulated in the hydrophobic domains. Increasing NR concentrations resulted in probe molecules located in a more hydrophilic environment, i.e., at the nanodomain border, and favored dye–dye interactions and NR aggregation.
These results correlate well with release experiments, indicating first NR release from more hydrophilic network locations. Overall, our findings demonstrate the importance to understand carrier–drug interactions for efficient loading and controlled release profiles in amphiphilic nanogels.
Changes in Black Truffle (Tuber melanosporum) Aroma during Storage under Different Conditions
(2024)
The enticing aroma of truffles is a key factor for their culinary value. Although all truffle species tend to be pricy, the most intensely aromatic species are the most sought after. Research into the aroma of truffles encompasses various disciplines including chemistry, biology, and sensory science. This study focusses on the chemical composition of the aroma of black truffles (Tuber melanosporum) and the changes occurring under different storage conditions. For this, truffle samples were stored under different treatments, at different temperatures, and measured over a total storage time of 12 days. Measurements of the truffle aroma profiles were taken with SPME/GC–MS at regular intervals. To handle the ample data collected, a systematic approach utilizing multivariate data analysis techniques was taken. This approach led to a vast amount of data which we made publicly available for future exploration. Results reveal the complexity of aroma changes, with 695 compounds identified, highlighting the need for a comprehensive understanding. Principal component analyses offer initial insights into truffle composition, while individual compounds may serve as markers for age (formic acid, 1-methylpropyl ester), freshness (2-Methyl-1-propanal; 1-(methylthio)-propane), freezing (tetrahydrofuran), salt treatment (1-chloropentane), or heat exposure (4-hydroxy-3-methyl-2-butanone). This research suggests that heat treatment or salt contact significantly affects truffle aroma, while freezing and cutting have less pronounced effects in comparison. The enrichment of compounds showing significant changes during storage was investigated with a metabolomic pathway analysis. The involvement of some of the enriched compounds on the pyruvate/glycolysis and sulfur pathways was shown.
Homochirality is an obvious feature of life on Earth. On the other hand, extraterrestrial samples contain largely racemic compounds. The same is true for any common organic synthesis. Therefore, it has been a perplexing puzzle for decades how these racemates could have formed enantiomerically enriched fractions as a basis for the origin of homochiral life forms. Numerous hypotheses have been put forward as to how preferentially homochiral molecules could have formed and accumulated on Earth. In this article, it is shown that homochirality of the abiotic organic pool at the time of formation of the first self-replicating molecules is not necessary and not even probable. It is proposed to abandon the notion of a molecular ensemble and to focus on the level of individual molecules. Although the formation of the first self-replicating, most likely homochiral molecule, is a seemingly improbable event, on a closer look, it is almost inevitable that some homochiral molecules have formed simply on a statistical basis. In this case, the non-selective leap to homochirality would be one of the first steps in chemical evolution directly out of a racemic “ocean”. Moreover, most studies focus on the chirality of the primordial monomers with respect to an asymmetric carbon atom. However, any polymer with a minimal size that allows folding to a secondary structure would spontaneously lead to asymmetric higher structures (conformations). Most of the functions of these polymers would be influenced by this inherently asymmetric folding. Furthermore, a concept of physical compartmentalization based on rock nanopores in analogy to nanocavities of digital immunoassays is introduced to suggest that complex cell walls or membranes were also not required for the first steps of chemical evolution. To summarize, simple and universal mechanisms may have led to homochiral self-replicating systems in the context of chemical evolution. A homochiral monomer pool is deemed unnecessary and probably never existed on primordial Earth.
The emission of ultrafine particles from small desktop Fused Filament Fabrication (FFF) 3D printers has been frequently investigated in the past years. However, the vast majority of FFF emission and exposure studies have not considered the possible occurrence of particles below the typical detection limit of Condensation Particle Counters and could have systematically underestimated the total particle emission as well as the related exposure risks. Therefore, we comparatively measured particle number concentrations and size distributions of sub-4 nm particles with two commercially available diethylene glycol-based instruments – the TSI 3757 Nano Enhancer and the Airmodus A10 Particle Size Magnifier. Both instruments were evaluated for their suitability of measuring FFF-3D printing emissions in the sub-4 nm size range while operated as a particle counter or as a particle size spectrometer. For particle counting, both instruments match best when the Airmodus system was adjusted to a cut-off of 1.5 nm. For size spectroscopy, both instruments show limitations due to either the fast dynamics or rather low levels of particle emissions from FFF-3D printing in this range. The effects are discussed in detail in this article. The findings could be used to implement sub-4 nm particle measurement in future emission or exposure studies, but also for the development of standard test protocols for FFF-3D printing emissions.
Peptide pools consist of short amino acid sequences and have proven to be versatile tools in various research areas in immunology and clinical applications. They are commercially available in many different compositions and variants. However, unlike other reagents that consist of only one or a few compounds, peptide pools are highly complex products which makes their quality control a major challenge. Quantitative peptide analysis usually requires sophisticated methods, in most cases isotope-labeled standards and reference materials. Usually, this would be prohibitively laborious and expensive. Therefore, an approach is needed to provide a practical and feasible method for quality control of peptide pools. With insufficient quality control, the use of such products could lead to incorrect experimental results, worsening the well-known reproducibility crisis in the biomedical sciences. Here we propose the use of ultra-high performance liquid chromatography (UHPLC) with two detectors, a standard UV detector at 214 nm for quantitative analysis and a high-resolution mass spectrometer (HRMS) for identity confirmation. To be cost-efficient and fast, quantification and identification are performed in one chromatographic run. An optimized protocol is shown, and different peak integration methods are compared and discussed. This work was performed using a peptide pool known as CEF advanced, which consists of 32 peptides derived from cytomegalovirus (CMV), Epstein–Barr virus (EBV) and influenza virus, ranging from 8 to 12 amino acids in length.
The non-steroidal anti-inflammatory drug (NSAID) diclofenac (DCF) is an important environmental contaminant occurring in surface waters all over the world, because, after excretion, it is not adequately removed from wastewater in sewage treatment plants. To be able to monitor this pollutant, highly efficient analytical methods are needed, including immunoassays. In a medical research project, monoclonal antibodies against diclofenac and its metabolites had been produced. Based on this monoclonal anti-DCF antibody, a new indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed and applied for environmental samples. The introduction of a spacer between diclofenac and the carrier protein in the coating conjugate led to higher sensitivity. With a test midpoint of 3 mg L−1 and a measurement range of 1–30 mg L−1, the system is not sensitive enough for direct analysis of surface water. However, this assay is quite robust against matrix influences and can be used for wastewater. Without adjustment of the calibration, organic solvents up to 5%, natural organic matter (NOM) up to 10 mg L−1, humic acids up to 2.5 mg L−1, and salt concentrations up to 6 g L−1 NaCl and 75 mg L−1 CaCl2 are tolerated. The antibody is also stable in a pH range from 3 to 12. Cross-reactivity (CR) of 1% or less was determined for the metabolites 40-hydroxydiclofenac (40-OH-DCF), 5-hydroxydiclofenac (5-OH-DCF), DCF lactam, and other NSAIDs. Relevant cross-reactivity occurred only with an amide derivative of DCF, 6-aminohexanoic acid (DCF-Ahx), aceclofenac (ACF) and DCF methyl ester (DCF-Me) with 150%, 61% and 44%, respectively. These substances, however, have not been found in samples. Only DCF-acyl glucuronide with a cross-reactivity of 57% is of some relevance. For the first time, photodegradation products were tested for cross-reactivity. With the ELISA based on this antibody, water samples were analysed. In sewage treatment plant effluents, concentrations in the range of 1.9–5.2 mg L−1 were determined directly, with recoveries compared to HPLC-MS/MS averaging 136%.
Concentrations in lakes ranged from 3 to 4.4 ng L−1 and were, after pre-concentration, determined with an average recovery of 100%
The biogenesis of iron–sulfur (Fe/S) proteins entails the synthesis and trafficking of Fe/S clusters, followed by their insertion into target apoproteins. In eukaryotes, the multiple steps of biogenesis are accomplished by complex protein machineries in both mitochondria and cytosol. The underlying biochemical pathways have been elucidated over the past decades, yet the mechanisms of cytosolic [2Fe-2S] protein assembly have remained ill-defined. Similarly, the precise site of glutathione (GSH) requirement in cytosolic and nuclear Fe/S protein biogenesis is unclear, as is the molecular role of the GSH-dependent cytosolic monothiol glutaredoxins (cGrxs). Here, we investigated these questions in human and yeast cells by various in vivo approaches. [2Fe-2S] cluster assembly of cytosolic target apoproteins required the mitochondrial ISC machinery, the mitochondrial transporter Atm1/ABCB7 and GSH, yet occurred independently of both the CIA system and cGrxs. This mechanism was strikingly different from the ISC-, Atm1/ABCB7-, GSH-, and CIA-dependent assembly of cytosolic–nuclear [4Fe-4S] proteins. One notable exception to this cytosolic [2Fe-2S] protein maturation pathway defined here was yeast Apd1 which used the CIA system via binding to the CIA targeting complex through its C-terminal tryptophan. cGrxs, although attributed as [2Fe-2S] cluster chaperones or trafficking proteins, were not essential in vivo for delivering [2Fe-2S] clusters to either CIA components or target apoproteins. Finally, the most critical GSH requirement was assigned to Atm1-dependent export, i.e. a step before GSH-dependent cGrxs function. Our findings extend the general model of eukaryotic Fe/S protein biogenesis by adding the molecular requirements for cytosolic [2Fe-2S] protein maturation.
The presence of endocrine-disrupting compounds (EDCs) in water poses a significant threat to human and animal health, as recognized by regulatory agencies throughout the world. The Yeast Estrogen Screen (YES) assay is an excellent method to evaluate the presence of these compounds in water due to its simplicity and capacity to assess the bioaccessible forms/fractions of these compounds. In the presence of a compound with estrogenic activity, Saccharomyces cerevisiae cells, containing a lacZ reporter gene encoding the enzyme β-galactosidase, are induced, the enzyme is synthesised, and released to the extracellular medium. In this work, a YES-based approach encompassing the use of a lacZ reporter gene modified strain of S. cerevisiae, microcarriers as solid support, and a fluorescent substrate, fluorescein di-β-D-galactopyranoside, is proposed, allowing for the assessment of EDCs’ presence after only 2 h of incubation. The proposed method provided an EC50 of 0.17 ± 0.03 nM and an LLOQ of 0.03 nM, expressed as 17β-estradiol. The assessment of different EDCs provided EC50 values between 0.16 and 1.2 × 103 nM. After application to wastewaters, similar results were obtained for EDCs screening, much faster, compared to the conventional 45 h spectrophotometric procedure using a commercial kit, showing potential for onsite high-throughput screening of environmental contamination.
A systematic series of industrial-relevant polystyrene-based anion exchange resins that are functionalized with hydro- or fluorocarbon chains are compared regarding their adsorption behavior toward perfluorocarboxylic acids (PFCA) in respect to their charge, chain length, and type of chain. The results clearly show the dominance of electrostatic interactions in the adsorption process as uncharged adsorber materials showed no adsorption at all. In contrast, the charged adsorber materials showed in general a PFCA removal of 80% to 30% over the experiment depending on effluent fraction.
Unexpectedly, for perfluorobutanoic acid (PFBA) the highest removal rate is found with consistently >90%. Despite observing significant benefits in the adsorption of PFCA for fluoroalkylated adsorbers in comparison to their non-fluorinated counterparts, this effect of fluoroalkylation is comparatively small and can not be clearly attributed to fluorophilic interactions between the fluoroalkyl chains. These findings help clarifying that the introduction of fluorocarbon moieties in adsorber materials is not necessary in order to remove fluorocarbon molecules from the environment.
Silicon isotope fractionation during silicification is poorly understood and impedes our ability to decipher paleoenvironmental conditions from Si isotopes in ancient cherts. To investigate isotope fractionation during silica-for-carbonate replacement we analyzed the microscale Si and O isotope composition in different silica phases in a silicified zebra dolostone as well as their bulk δ18O and Δ’17O compositions. The subsequent replacement of carbonate layers is mimicked by decreasing δ18O and δ30Si. The textural relationship and magnitude of Si and O isotope fractionation is best explained by near-quantitative silica precipitation in an open system with finite Si. A Rayleigh model for silicification suggests positive Ɛ30/28Si during silicification, conforming with predictions for isotope distribution at chemical equilibrium from ab-initio models. Application of the modelled Ɛ30Si-T relationship yields silicification temperatures of approx. 50°C. To reconcile the δ18Ochert composition with these temperatures, the δ18O of the fluid must have been between -2.5 and -4 ‰, compositions for which the quartz phases fall close to the oxygen equilibrium fractionation line in three-isotope space. Diagenetic silica replacement appears to occur in O and Si isotopic equilibrium allowing reconstructions of temperatures of silicification from Si isotopes and derive the δ18O composition of the fluid – a highly desired value needed for accurate reconstructions of the temperature- and δ18O histories of the oceans.
Here, we report a comparative study of different sum parameter analysis methods for the extraction of per- and polyfluoroalkyl substances (PFAS) from manufactured consumer products, which can be measured by combustion ion chromatography (CIC). Therefore, a hydrolysis-based extraction method was further developed, which accounts for the addition of hydrolyzable covalently bound polyfluoroalkylated side-chain polymers (SFPs) to the extractable organic fluorine portion of the mass balance proposed as "hydrolyzable organically bound fluorine" (HOF). To test this hypothesis, the method was applied to 39 different consumer products containing fluoropolymers or monomeric PFAS taken from four different categories: outdoor textiles, paper packaging, carpeting, and permanent baking sheets. We also evaluated the method's efficiency by extracting four synthesized fluorotelomer polyacrylate reference compounds. The total fluorine (TF) and extractable organically bound fluorine (EOF) values were measured through CIC using established protocols. The TF values ranged from sub-ppb to %-levels, depending on the compound class. All samples showed results for hydrolyzed organofluorine (HOF) between 0.03 and 76.3 μg/g, while most EOF values were lower (<LOD to 58.1 μg/g). Moreover, the methods were contrasted with the "total hydrolyzable precursor" (THP) assay analyzed using gas-chromatography coupled mass spectrometry (GC-MS), which yielded concentrations of 6:2–10:2 fluorotelomer alcohols (<LOD-568 μg/g) for textile and paper samples. Furthermore, targeted analytical investigation of 25 compounds via liquid chromatography coupled tandem mass spectrometry (LC-MS/MS) was conducted and accounted for significantly lower sum amounts (<LOD-0.98 μg PFAS/g). To estimate the fluorine mass balance of all methods, the fluorine levels of target analytical data were calculated and compared to the sum parameter values and evaluated. Finally, the efficiency of the extraction method was approximated by the recovery analysis of four selected SFP model compounds compared to their TF values, yielding 36.7–74.0% after extraction and 3.8–36.3% after processing the extract for the HOF sum parameter.
Volatile organic compounds (VOCs) are of interest in many different fields. Among them are food and fragrance analysis, environmental and atmospheric research, industrial applications, security or medical and life science. In the past, the characterization of these compounds was mostly performed via sample collection and off-site analysis with gas chromatography coupled to mass spectrometry (GC-MS) as the gold standard. While powerful, this method also has several drawbacks such as being slow, expensive, and demanding on the user. For decades, intense research has been dedicated to find methods for fast VOC analysis on-site with time and spatial resolution. We present the working principles of the most important, utilized, and researched technologies for this purpose and highlight important publications from the last five years. In this overview, non-selective gas sensors, electronic noses, spectroscopic methods, miniaturized gas chromatography, ion mobility spectrometry and direct injection mass spectrometry are covered. The advantages and limitations of the different methods are compared. Finally, we give our outlook into the future progression of this field of research.
Per- and polyfuoroalkyl substances (PFAS) are emerging organic pollutants and can occur in surface and groundwater. To identify the degree of pollution in surface water with PFAS, often targeted HPLC–ESI–MS/MS has been employed in which commonly 30–40 compounds are analyzed. However, other PFAS and organofuorines remain undetected. We sampled surface water of the river Spree and the Teltow Canal in Berlin, Germany, which are afected by the efuent discharge of wastewater treatment plants. Here, we employed high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) for measuring extractable organofuorines (EOF) and compared in a mass balance approach the total fuorine to the identifed and quantifed PFAS from the targeted analysis. The analysis highlights that the EOF are in the range expected for an urban river system (Winchell et al. in Sci Total Environ 774, 2021). However, downstream of an efuent discharge, the EOF increased by one order of magnitude, e.g., 40.3 to 574 ng F L−1, along the Teltow Canal. From our target analytes, mostly short-chained perfuorinated carboxylic acids and sulfonates occur in the water, which however makes up less than 10% of the EOF. The increase in EOF in the Teltow Canal correlates well with the increase of perfuorohexanoic acid (PFHxA), indicating that PFHxA is characteristic for the discharged EOF but not responsible for the increase. Hence, it points to PFHxA precursor discharge. The study highlights that EOF screening using HR-CS-GFMAS is necessary to identify the full scale of pollution with regard to PFAS and other organofuorines such as pharmaceutical compounds from the efuent of WWTPs.
This study describes an interlaboratory comparison (ILC) among nine (9) laboratories to evaluate and validate the standard operation procedure (SOP) for single-particle (sp) ICP-TOFMS developed within the context of the Horizon 2020 project ACEnano. The ILC was based on the characterization of two different Pt nanoparticle (NP) suspensions in terms of particle mass, particle number concentration, and isotopic composition. The two Pt NP suspensions were measured using icpTOF instruments (TOFWERK AG, Switzerland).
Two Pt NP samples were characterized and mass equivalent spherical sizes (MESSs) of 40.4 ± 7 nm and 58.8 ± 8 nm were obtained, respectively. MESSs showed <16% relative standard deviation (RSD) among all participating labs and <4% RSD after exclusion of the two outliers. A good agreement was achieved between the different participating laboratories regarding particle mass, but the particle number concentration results were more scattered, with <53% RSD among all laboratories, which is consistent with results from previous ILC studies conducted using ICP-MS instrumentation equipped with a sequential mass spectrometer. Additionally, the capabilities of sp-ICP-TOFMS to determine masses on a particle basis are discussed with respect to the potential for particle density determination. Finally, because quasi-simultaneous multi-isotope and multielement determinations are a strength of ICP-TOFMS instrumentation, the precision and trueness of isotope ratio determinations were assessed. The average of 1000 measured particles yielded a precision of below ±1% for intensity ratios of the most abundant Pt isotopes, i.e. 194Pt and 195Pt, while the accuracy of isotope ratios with the lower abundant isotopes was limited by counting statistics.
Lanthanide-based, spectrally shifting, and multi-color luminescent upconverting nanoparticles (UCNPs) have received much attention in the last decades because of their applicability as reporter for bioimaging, super-resolution microscopy, and sensing as well as barcoding and anti-counterfeiting tags. A prerequisite for the broad application of UCNPs in areas such as sensing and encoding are simple, robust, and easily upscalable synthesis protocols that yield large quantities of UCNPs with sizes of 20 nm or more with precisely controlled and tunable physicochemical properties from lowcost reagents with a high reproducibility. In this context, we studied the reproducibility, robustness, and upscalability of the synthesis of β-NaYF4:Yb, Er UCNPs via thermal decomposition. Reaction parameters included solvent, precursor chemical compositions, ratio, and concentration. The resulting UCNPs were then examined regarding their application-relevant physicochemical properties such as size, size distribution, morphology, crystal phase, chemical composition, and photoluminescence.
Based on these screening studies, we propose a small volume and high-concentration synthesis approach that can provide UCNPs with different, yet controlled size, an excellent phase purity and tunable morphology in batch sizes of up to at least 5 g which are well suited for the fabrication of sensors, printable barcodes or authentication and recycling tags.
This work aimed to evaluate high-resolution continuum source molecular absorption spectrometry (HR-CS MAS), traditionally used to determine non-metals, for the determination of a new element, metal, vanadium. VO was selected as a target molecule because it is relatively stable and was expected to be spontaneously generated in a flame or a graphite furnace (GF). The high-resolution overview spectra of the molecule were obtained in a wide range of 480–630 nm, and absorption due to the X4Σ−–C4Σ− electronic transition was registered. A unique instrumental setup, comprising a prototype Modular Simultaneous Echelle Spectrograph (MOSES) and a commercial HR-CS MAS apparatus, was applied in the research. Finally, the spectral area centered at 550.6230 nm was selected for analysis. A method was developed to determine V in solutions of catalysts of heavy petroleum oil hydroprocessing using a commercial HR-CS spectrometer in a flame version. Although sensitivity was relatively poor (characteristic concentration 380 mg L−1), an extremely low noise enabled reaching a satisfactory detection limit (20 mg L−1 in solution, i.e. 0.1% m:m in the catalyst). For the first time vanadium was determined using ordinary air-acetylene flame. The obtained results were consistent with the results of atomic absorption spectrometry with N2O-C2H2 flame. Unfortunately, only a small population of VO molecules could have been generated in GF measurements. Furthermore, the observed VO molecules appeared only at unfavorably high temperatures. The work shows the potential of HR-CS MAS as a scientific tool for investigating the mechanism of processes occurring in the GF. This work can inspire other research of new analytes for HR-CS MAS.
In this study, five laboratories, namely, BRML (Romania), TUBITAK UME (Turkey), IMBIH (Bosnia and Herzegovina), BAM (Germany), and DTI (Denmark), developed and validated analytical procedures by ICP-MS, ICP-OES, MWP-AES, WD-XRF, and ID-MS for the determination of inorganic
impurities in solid and liquid biofuels, established the budget of uncertainties, and developed the method for determining the amount of ash in the measurement range 0–1.2% with absolute repeatability less than 0.1% and absolute reproducibility of 0.2% (according to EN ISO 18122). In order to create homogeneous certified reference materials, improved methodologies for the measurement and characterization of solid and liquid biofuels were developed. Thus, information regarding the precision, accuracy, and bias of the method, and identifying the factors that intervened in the measurement of uncertainty were experimentally determined, supplementing the information from the existing standards in the field.
We investigated the performance of nitrogen microwave inductively coupled atmospheric-pressure plasma mass spectrometry (MICAP-MS) under matrix effects and its applicability to trace element analysis in steels. Influences of different gas flows and ion optics on the matrix tolerance are studied, indicating that nebulizer gas flow has the most significant impact. Optimization of ion optics improves matrix tolerance for light elements due to the reduction of the inelastic collisional scattering effect. With optimized operating conditions, MICAP-MS achieves an internal standard intensity recovery of over 90% at an Fe concentration of 500 mg L−1. Even at an Fe concentration of 1 g L−1, the recovery remains above 80%. Three certified reference materials – non-alloy, low-alloy and high-alloy steel – were analyzed using MICAP-MS. The determined mass concentrations of the trace and minor components show metrological compatibility to the reference values. No significant differences are observed between the results obtained with aqueous and matrix-matched calibration, demonstrating the strong matrix tolerance of MICAP-MS, and its promising applicability to steel analysis.
An interlaboratory comparison (ILC)was organised to characterise 87Sr/86Sr isotope ratios in geological and industrial reference materials by applying the so-called conventional method for determining 87Sr/86Sr isotope ratios. Four cements (VDZ 100a,VDZ 200a, VDZ 300a, IAG OPC-1), one limestone (IAG CGL ML-3) and one slate (IAG OU-6) reference materials were selected, covering a wide range of naturally occurring Sr isotopic signatures. Thirteen laboratories received aliquots of these six reference materials together with a detailed technical protocol. The consensus values for the six reference materials and their associated measurement uncertainties were obtained by applying a Gaussian, linear mixed effects model fitted to all the measurement results. By combining the consensus values and their uncertainties with an uncertainty contribution for potential heterogeneity, reference values ranging from 0.708134 mol mol-1 to 0.729778 mol mol-1 were obtained with relative expanded uncertainties of ≤ 0.007 %. This study represents an ILC on conventional 87Sr/86Sr isotope ratios, within which metrological principles were considered and the compatibility of measurement results obtained by MC-ICP-MS and by MC-TIMS is demonstrated. The materials characterised in this study can be used as reference materials for validation and quality control purposes and to estimate measurement uncertainties in conventional 87Sr/86Sr isotope ratio measurement.
During its 25 years of existence, the Inorganic Analysis Working Group of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM IAWG) has achieved much in establishing comparability of measurement results. Impressive work has been done on comparison exercises related to real-world problems in fields such as ecology, food, or health. In more recent attempts, measurements and comparisons were focused on calibration solutions which are the basis of most inorganic chemical measurements. This contribution deals with the question of how to achieve full and transparent SI traceability for the values carried by such solutions. Within this framework, the use of classical primary methods (CPMs) is compared to the use of a primary difference method (PDM). PDM is a method with a dual character, namely a metrological method with a primary character, based on the bundling of many measurement methods for individual impurities, which lead to materials with certified content of the main component. As in classical methods, where small corrections for interferences are accepted, in PDM, many small corrections are bundled. In contrast to classical methods, the PDM is universally applicable to all elements in principle. Both approaches can be used to certify the purity (expressed as mass fraction of the main element) of a high-purity material. This is where the metrological need of National Metrology Institutes (NMIs) for analytical methods meet the challenges of analytical methods. In terms of methods, glow discharge mass spectrometry (GMDS) with sufficient uncertainties for sufficiently small impurity contents is particularly noteworthy for the certification of primary transfer standards (PTS), and isotope dilution mass spectrometry (IDMS), which particularly benefits from PTS (back-spikes) with small uncertainties, is particularly noteworthy for the application. The corresponding relative uncertainty which can be achieved using the PDM is very low (< 10−4). Acting as PTS, they represent the link between the material aspect of the primary calibration solutions and the immaterial world of the International System of Units (SI). The underlying concepts are discussed, the current status of implementation is summarised, and a roadmap of the necessary future activities in inorganic analytical chemistry is sketched. It has to be noted that smaller measurement uncertainties of the purity of high-purity materials not only have a positive effect on chemical measurements, but also trigger new developments and findings in other disciplines such as thermometry or materials science.
Physical adsorption at cryogenic temperature (cryoadsorption) is a reversible mechanism that can reduce the pressure of conventional compressed gas storage systems. Metal–organic framework (MOF) materials are remarkable candidates due to the combination of high specific surface area and density which, in some cases, provide a high volumetric storage capacity. However, such extensive use of MOFs for this application requires the selection of affordable structures, easy to produce and made from feasible metallic and organic components. Herein, we introduce a MOF database detailing the crystallographic and porous properties of 3600 existing MOFs made from industrially relevant metals and their organic composition. The comparison of the available minimum costs of linkers allowed the creation of a database to select affordable structures with high potential for volumetric hydrogen storage by cryoadsorption, considering their composition based on individual or mixed building blocks. A user interface, available online, facilitates the selection of MOFs based on the properties or names of structures and linkers.
Cryoadsorption on the inner surface of porous materials is a promising solution for safe, fast, and reversible hydrogen storage. Within the class of highly porous metal−organic frameworks, zeolitic imidazolate frameworks (ZIFs) show high thermal, chemical, and mechanical stability. In this study, we selected ZIF-8 synthesized mechanochemically by twin-screw extrusion as powder and pellets. The hydrogen storage capacity at 77 K and up to 100 bar has been analyzed in two laboratories applying three different measurement setups showing a high reproducibility. Pelletizing ZIF-8 increases the packing density close to the corresponding value for a single crystal without loss of porosity, resulting in an improved volumetric hydrogen storage capacity close to the upper limit for a single crystal. The high volumetric uptake combined with a low and constant heat of adsorption provides ca. 31 g of usable hydrogen per liter of pellet assuming a temperature−pressure swing adsorption process between 77 K − 100 bar and 117 K − 5 bar. Cycling experiments do not indicate any degradation in storage capacity. The excellent stability during preparation, handling, and operation of ZIF-8 pellets demonstrates its potential as a robust adsorbent material for technical application in pilot- and full-scale adsorption vessel prototypes.
The application of compact NMR instruments to hot flowing samples or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is not designed for such temperature compensation. Passive insulation is restricted by the small dimensions within the magnet borehole. Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements through thermography, a model predictive control was set up to minimise any disturbance effect on the permanent magnet from the probe or sample temperature. This methodology will facilitate the application of variable-temperature shielding and, therefore, extend the application of compact NMR instruments to flowing sample temperatures that differ from the magnet temperature.
Ratiometric green–red fluorescent nanosensors for fluorometrically monitoring pH in the acidic range were designed from 80 nm-sized polystyrene (PS) and silica (SiO2) nanoparticles (NPs), red emissive reference dyes, and a green emissive naphthalimide pH probe, analytically and spectroscopically characterized, and compared regarding their sensing performance in aqueous dispersion and in cellular uptake studies. Preparation of these optical probes, which are excitable by 405 nm laser or LED light sources, involved the encapsulation of the pH-inert red-fuorescent dye Nile Red (NR) in the core of self-made carboxylated PSNPs by a simple swelling procedure and the fabrication of rhodamine B (RhB)-stained SiO2-NPs from a silane derivative of pH-insensitive RhB. Subsequently, the custom-made naphthalimide pH probe, that utilizes a protonation-controlled photoinduced electron transfer process, was covalently attached to the carboxylic acid groups at the surface of both types of NPs. Fluorescence microscopy studies with the molecular and nanoscale optical probes and A549 lung cancer cells confirmed the cellular uptake of all probes and their penetration into acidic cell compartments, i.e., the lysosomes, indicated by the switching ON of the green naphthalimide fluorescence. This underlines their suitability for intracellular pH sensing, with the SiO2-based nanosensor revealing the best performance regarding uptake speed and stability.
The performance of second generation ICP-TOFMS, equipped with a micro-channel plate (MCP) enabling multi-isotope detection, in terms of isotope ratio precision and instrumental isotopic fractionation (IIF) for (multi-)isotope ratio analysis was thoroughly assessed for B, Sr and Pb. Experimental isotope ratio precision of 0.14 % for 11B/10B intensity ratio, 0.15 % for 87Sr/86Sr intensity ratio and 0.07% for 208Pb/206Pb intensity ratio were obtained at high signal levels ($500 mg L−1) which is comparable to first generation ICP-TOFMS. The long-term stability of isotope ratios, measured over several hours and expressed as repeatability, is between 0.05 % and 1.8 % for B, Sr and Pb. The observed IIF per mass unit is negative for B (i.e., −11 % for 11B/10B) which is in accordance with measurements using sector field (MC) ICP-MS. But the observed IIF per mass unit is positive for Sr (i.e., 2 % for 87Sr/86Sr) and Pb (i.e., 4.5 % for 208Pb/206Pb) which is not in accordance with measurements using sector field (MC) ICP-MS. Furthermore, different IIFs per mass unit were observed for different isotope pairs of the same isotopic system (i.e., Sr, Pb) and adjacent isotopic systems (i.e., Pb vs. Tl). This and the observations from three-isotope plots for Sr and Pb show that ion formation, ion extraction, ion transmission, ion separation and ion detection in second generation ICP-TOFMS is subject to IIF that does not follow the known mass dependent fractionation laws and is possibly caused by mass independent fractionation and/or multiple (contradictory) fractionation processes with varying contributions. The non-mass dependent IIF behavior observed for second generation ICP TOFMS has profound consequences for the IIF correction of isotope raw data, including application of multi-isotope dilution mass spectrometry (IDMS) using ICP-TOFMS. Hence, only IIF correction models that correct also for mass independent fractionation are applicable to calculate reliable isotope ratios using second generation ICP-TOFMS. In the present study, reliable d11B values, and absolute B, Sr and Pb isotope ratios could be determined using the SSB approach in single-element solutions as well as in a mixture of B, Sr and Pb, where the isotopes were measured simultaneously.
Gold-based nanoparticles below 2 nm in size are promising as luminescent probes for in vivo bioimaging, owing to their brightness and rapid renal clearance. However, their use as contrast agents in the near-infrared II (NIR-II, 1000–1700 nm) range remains challenging due to their low photoluminescence (PL) quantum yield. To address this, PL enhancement can be achieved by either rigidifying the ligand-shell structure or increasing the size of the ligand shell. In this study, we synthesized ultra-small gold nanoparticles stabilized by co-ligands, namely monothiol and short dithiol molecules. By precisely controlling the amount of reducing agent used during particle preparation, we successfully modulated the physicochemical properties of the co-ligand shell, including its size, composition, and structure. Consequently, we achieved a remarkable 60-fold increase in the absorption cross-section at 990 nm while maintaining the small size of the 1.5-nm metal core. The analytical and optical characterization of our thiol-capped gold nanoparticles indicates that the ligand shell size is governed by the quantity of the reducing agent, which, in turn, impacts the balance between radiative and non-radiative processes, thereby influencing the PL quantum yield.
Ergot alkaloids are a group of toxic compounds, formed by fungi on infested grasses. In 2022, the European Commission set into effect maximum levels for the sum of the twelve major ergot alkaloids in multiple foods. To facilitate the laborious and costly individual quantification of the twelve major ergot alkaloids by HPLC–MS/MS or -FLD, we recently reported a sum parameter method (SPM) for ergot alkaloid quantification. Here, derivatization to lysergic acid hydrazide—a derivative of the mutual ergoline backbone in all ergot alkaloids—allowed simplified determination of all ergot alkaloids in flour via HPLC-FLD. For the measurement of more complex matrices like processed foods, we now developed a MS/MS-based SPM. Two internal standards (IS), isotopically labelled at different positions of the molecule, were synthesized and employed in the MS/MS-measurements. Method performance using either the 13CD3-labelled or the 15N2-labelled IS was evaluated on naturally contaminated rye and wheat flour samples as well as on processed food matrices. Employing the 13CD3-labelled IS leads to lower variances and better consistency with the reference data (obtained by the FLD-based SPM) in flour samples compared to the 15N2-labelled IS. The novel method significantly improves the measurement of ergot alkaloids in complex food matrices, due to their increased selectivity and thus lower interferences. Furthermore, the application of isotope labelled IS obviates the need for time-consuming steps like the determination of recovery rate based, matrix specific correction factors as described in the MS/MS-based European standard method for ergot alkaloid quantification (EN 17425).
Early detection of cancer is essential for successful treatment and improvement in patient prognosis. Deregulation of post-translational modifications (PTMs) of proteins, especially phosphorylation, is present in many types of cancer. Therefore, the development of materials for the rapid sensing of low abundant phosphorylated peptides in biological samples can be of great therapeutic value. In this work, we have synthesised fluorescent molecularly imprinted polymers (fMIPs) for the detection of the phosphorylated tyrosine epitope of ZAP70, a cancer biomarker. The polymers were grafted as nanometer-thin shells from functionalised submicron-sized silica particles using a reversible addition-fragmentation chain-transfer (RAFT) polymerisation. Employing the combination of fluorescent urea and intrinsically cationic bis-imidazolium receptor cross-linkers, we have developed fluorescent sensory particles, showing an imprinting factor (IF) of 5.0. The imprinted polymer can successfully distinguish between phosphorylated and non-phosphorylated tripeptides, reaching lower micromolar sensitivity in organic solvents and specifically capture unprotected peptide complements in a neutral buffer. Additionally, we have shown the importance of assessing the influence of counterions present in the MIP system on the imprinting process and final material performance. The potential drawbacks of using epitopes with protective groups, which can co-imprint with targeted functionality, are also discussed.
Human papillomavirus (HPV) DNA detection can enable the early diagnosis of high-risk HPV types responsible for cervical cancer. HPV detection is also essential for investigating the clinical behavior and epidemiology of particular HPV types, characterization of study populations in HPV vaccination trials and monitoring the efficacy of HPV vaccines. In this study, two azaBODIPY dyes (1 and 2) were used as references and were doped into polystyrene particles (PS40), while a short HPV DNA single strand was used as a target molecule and was covalently bound to the silica shell. These particles were employed as optical probes in 1:1 hybridization assays, and their potential applicability as a tool for multiplex assays for the detection of different strands of HPV was evaluated using flow cytometry. A good separation in the fluorescence of the four different voncentrations prepared for each dye was observed. To perform the hybridization assays, HPV18, HPV16, HPV11 and HPV6 single strands were attached to the particles through EDC-mediated coupling. The c-DNA-1-PS40 and c-DNA-2-PS40 particles exhibited low limit of detection (LOD) and quantification (LOQ) values for HPV11, and a narrow detection range was obtained. Multiplexed assay experiments were successfully performed for both particles, and the results proved that c-DNA-1-PS40 could potentially be used as a tool for multiplexing assays and merits further in-depth study in this context.
Detailed knowledge about soil composition is an important prerequisite for many applications, for example precision agriculture. Current standard laboratory methods are complex and time-consuming but could be complemented by non-invasive optical techniques. Its capability to provide a molecular fingerprint of individual soil components makes Raman spectroscopy a very promising candidate. A major challenge is strong fluorescence interference inherent to soil, but this issue can be overcome effectively using shifted excitation Raman difference spectroscopy (SERDS). A customized dual-wavelength diode laser emitting at 785.2 and 784.6 nm was used to investigate 117 soil samples collected from an agricultural field along a distance of 624 m and down to depths of 1 m. To address soil spatial heterogeneity, a raster scan approach comprising 100 measurement spots per sample was applied. Based on the Raman spectroscopic fingerprint extracted from intense fluorescence interference by SERDS, 13 mineral soil constituents were identified, and even closely related molecular species could be discriminated, for example polymorphs of titanium dioxide and calcium carbonate. For the first time, the capability of SERDS is demonstrated to predict the calcium carbonate content as an important soil parameter using partial least squares regression (R2 = 0.94, root mean square error of cross-validation RMSECV = 2.1%). Our findings demonstrate that SERDS can extract a wealth of spectroscopic information from disturbing backgrounds enabling qualitative and quantitative soil analysis. This highlights the large potential of SERDS for precision agriculture but also in further application areas, for example geology, cultural heritage and planetary exploration.
The generation of ozone and nitrogen oxides by laser-induced dielectric breakdown (LIDB) in mixtures of air with noble gases Ar, He, Kr, and Xe is investigated using OES and IR spectroscopy, mass spectrometry, and absorption spectrophotometry. It is shown that the formation of NO and NO2 noticeably depends on the type of inert gas; the more complex electronic configuration and the lower ionization potential of the inert gas led to increased production of NO and NO2. The formation of ozone occurs mainly due to the photolytic reaction outside the gas discharge zone. Equilibrium thermodynamic analysis showed that the formation of NO in mixtures of air with inert gases does not depend on the choice of an inert gas, while the equilibrium concentration of the NO+ ion decreases with increasing complexity of the electronic configuration of an inert gas.
An automated and straightforward detection and data treatment strategy for the determination of the protein relative concentration in individual human cells by single cell–inductively coupled plasma–time-of-flight mass spectrometry (sc-ICP-ToF-MS) is proposed. Metal nanocluster (NC)-labeled specific antibodies for the target proteins were employed, and ruthenium red (RR) staining, which binds to the cells surface, was used to determine the number of cell events as well as to evaluate the relative volume of the cells. As a proof of concept, the expression of hepcidin, metallothionein-2, and ferroportin employing specific antibodies labeled with IrNCs, PtNCs, and AuNCs, respectively, was investigated by sc-ICP-ToF-MS in human ARPE-19 cells. Taking into account that ARPE-19 cells are spherical in suspension and RR binds to the surface of the cells, the Ru intensity was related to the cell volume (i.e., the cell volume is directly proportional to (Ru intensity)3/2), making it possible to determine not only the mass of the target proteins in each individual cell but also the relative concentration. The proposed approach is of particular interest in comparing cell cultures subjected to different supplementations. ARPE-19 cell cultures under two stress conditions were compared: a hyperglycemic model and an oxidative stress model. The comparison of the control with treated cells shows not only the mass of analyzed species but also the relative changes in the cell volume and concentration of target proteins, clearly allowing the identification of subpopulations under the respective treatment.
Surface-functionalized polymer beads encoded with molecular luminophores and nanocrystalline emitters such as semiconductor nanocrystals, often referred to as quantum dots (QDs), or magnetic nanoparticles are broadly used in the life sciences as reporters and carrier beads. Many of these applications require a profound knowledge of the chemical nature and total number of their surface functional groups (FGs), that control bead charge, colloidal stability, hydrophobicity, and the interaction with the environment and biological systems. For bioanalytical applications, also the
number of groups accessible for the subsequent functionalization with, e.g., biomolecules or targeting ligands is relevant. In this study, we explore the influence of QD encoding on the amount of carboxylic acid (COOH) surface FGs of 2 μm polystyrene microparticles (PSMPs). This is done for frequently employed oleic acid and oleylamine stabilized, luminescent core/shell CdSe QDs and two commonly used encoding procedures. This included QD addition during bead formation by a thermally induced polymerization reaction and a post synthetic swelling procedure. The accessible number of COOH groups on the surface of QD-encoded and pristine beads was quantified by two colorimetric assays, utilizing differently sized reporters and electrostatic and covalent interactions. The results were compared to the total number of FGs obtained by a conductometric titration and Fourier transform infrared spectroscopy (FTIR). In addition, a comparison of the impact of QD and dye encoding on the bead surface chemistry was performed. Our results demonstrate the influence of QD encoding and the QD-encoding strategy on the number of surface FG that is ascribed to an interaction of the QDs with the carboxylic acid groups on the bead surface. These findings are of considerable relevance for applications of nanoparticle-encoded beads and safe-by-design concepts for nanomaterials.
Laser-induced breakdown spectroscopy (LIBS) is becoming a more mature technology every year with new variants such as laser ablation molecular isotopic spectrometry, reheating by various discharge techniques, and multiple pulse excitation schemes, in which sometimes lasers of different pulse lengths are used. However, lasers with inherent parameters like pulse length and repetition rate are still almost exclusively employed. Recent years have witnessed the advent of novel high-repetition-rate laser concepts for machining processes, like welding, milling, and engraving. Here, a comprehensive study of single-pulse LIBS spectra of a single aluminum target is presented to showcase the applicability of flexible high duty-cycle master oscillator power amplifier (MOPA) lasers. Although traditional flashlamp-pumped Fabry–Pérot lasers only permit a variation in the pulse energy and are operated at very low duty-cycles, MOPA lasers add repetition rate and pulse length as variable parameters. A thorough analysis of the temporal plasma behavior revealed the emission dynamic to closely match the excitation laser pulse pattern. An aluminum sample’s spectral response was shown to be significantly impacted by variations in both rate and length. Although the spectral emission strength of the elemental lines of Al, Sr, and Ca all peaked at slightly different parameter settings, the strongest impact was found on the relative abundance of molecular AlO bands. Unlike in previous laser ablation molecular isotopic spectrometry (LAMIS) publications, the latter could be readily detected with a good intensity and well-resolved spectral features without any temporal gating of the detector. This finding, together with the fact that MOPA lasers are both inexpensive and dependable, makes for a promising combination for future studies including the detection of diatomic band structures.
Mobile proximal gamma-ray spectrometry (GS) is an emerging approach to estimate soil texture directly in the field. It relies on gamma radiation emitted during the natural decay of potassium-40 (K-40) and other isotopes. The K-40 counts are correlated with total K content, mineralogical soil composition and therefore with soil texture. Yet, it is not clear if K fertilisation impacts the ratio of K-40 to total K which would necessitate to take the fertilisation history into account for soil sensing applications. To elucidate this question, a well-documented long-term experiment was selected. The soils of the Rengen grassland experiment (55 plots) were investigated for total K (XRF-K) and for K-40 via mobile proximal GS. No significant differences in XRF-K and K-40 were found between the treatments with and without K fertilisation, although formely published results point to negative and positive K balances, respectively. Fertiliser analysis revealed a ratio of K-40 to total K that was almost identical to the natural abundance of 0.0117%. It was concluded that it is not necessary to take K fertilisation history into account when predicting soil texture from mobile proximal GS on agricultural land for, e.g., precision farming purposes.
The frequency-domain (FD) method provides an alternative to the commonly used time-domain (TD) approach in characterizing the luminescence kinetics of luminophores, with its own strengths, e.g., the capability to decouple multiple lifetime components with higher reliability and accuracy. While extensively explored for characterizing luminophores with down-shifted emission, this method has not been investigated for studying nonlinear luminescent materials such as lanthanide-doped upconversion nanoparticles (UCNPs), featuring more complicated kinetics. In this work, employing a simplified rate-equation model representing a standard two-photon energy-transfer upconversion process, we thoroughly analyzed the response of the luminescence of UCNPs in the FD method. We found that the FD method can potentially obtain from a single experiment the effective decay rates of three critical energy states of the sensitizer/activator ions involved in the upconversion process. The validity of the FD method is demonstrated by experimental data, agreeing reasonably well with the results obtained by TD methods.
AbstractIn this study, we present a screening method based on molecular absorption spectrometry to study PFAS uptake and fate in plants. To evaluate the suitability of this method we analyzed plant extracts with molecular absorption spectrometry (MAS) as well as liquid chromatography–tandem mass spectrometry (LC–MS/MS) for mass balance studies (w(F)). French bean plants (Phaseolus vulgaris) were grown on soil spiked using eight PFAS substances that vary in chain length and functional group composition. Specifically, these include three short-chained (C4–C5), five long-chained (C7–C10) carboxylic acids, one sulfonic acid and one sulfonic amide moieties. To investigate substance-specific PFAS uptake systematically, PFAS were spiked as single substance spike. Additionally, we studied one mixture of the investigated substances in equal proportions regarding w(F) and four PFAS mixtures of unknown composition. After 6 weeks, the plants were separated into four compartments. We analyzed the four compartments as well as the soil for extractable organically bound fluorine (EOF) by high resolution-continuum source-graphite furnace-molecular absorption spectrometry (HR-CS-GFMAS) as well as for sum of ten target-PFAS by LC–MS/MS. All three short-chained PFAS perfluorobutanoic acid (PFBA), perfluorobutanoic sulfonic acid (PFBS) and perfluoropentanoic acid (PFPeA) were determined in high concentrations mainly in the fruits of the investigated plants while long-chained PFAS perfluorononanoic acid (PFNA) and perfluorodecanoic acid (PFDA) were mainly determined in roots. PFBS was determined in remarkably high concentrations in leaves compartment by both quantification methods. Overall, comprehensive results of single substance spikes were in good agreement for both methods except for a few cases. Hence, two phenomena were identified: for mixed PFAS spikes of unknown composition huge differences between EOF and sum of target PFAS were observed with systematically higher EOF values. Overall, both methods indicate comparable results with MS being more reliable for known PFAS contamination and MAS being more valuable to identify PFAS exposure of unknown composition.
Graphical Abstract
Molten sulfur is found in various subaerial volcanoes. However, limited records of the pools and flows of molten sulfur have been reported: therefore, questions remain regarding the physicochemical processes behind this phenomenon. A suite of new sulfur flows, some of which active, was identified at the Lastarria volcano (northern Chile) and studied using satellite imagery, in situ probing, and temperature and video recording. This finding provides a unique opportunity to better understand the emplacement mechanisms and mineral and chemical compositions of molten sulfur, in addition to gaining insight into its origin. Molten sulfur presented temperatures of 124–158°C, with the most prolonged sulfur flow reaching 12 m from the source. Photogrammetric tools permitted the identification of levees and channel structures, with an estimated average flow speed of 0.069 m/s. Field measurements yielded a total volume of 1.45 ± 0.29 m3 of sulfur (equivalent to ∼2.07 tons) mobilized during the January 2019 event for at least 408 min. Solidified sulfur was composed of native sulfur with minor galena and arsenic- and iodine-bearing minerals. Trace element analysis indicated substantial enrichment of Bi, Sb, Sn, Cd, as well as a very high concentration of As (&gt;40.000 ppm). The January 2019 molten sulfur manifestations in Lastarria appear to be more enriched in As compared to the worldwide known volcanoes with molten sulfur records, such as the Shiretoko-Iozan and Poás volcanoes. Furthermore, their rheological properties suggest that the “time of activity” in events such as this could be underestimated as flows in Lastarria have moved significantly slower than previously thought. The origin of molten sulfur is ascribed to the favorable S-rich chemistry of fumarolic gases and changes in host rock permeability (fracture opening). Molten sulfur in Lastarria correlates with a peak in activity characterized by high emissions of SO2 and other acid species, such as HF and HCl, in addition to ground deformation. Consequently, molten sulfur was framed within a period of volcanic unrest in Lastarria, triggered by changes in the magmatic-hydrothermal system. The appearance of molten sulfur is related to physicochemical perturbations inside the volcanic system and is perhaps a precursor of eruptive activity, as observed in the Poás and Turrialba volcanoes.
Trace element (TE) analysis of pyrite via LA-ICP-MS can be used to reconstruct the conditions of pyrite formation in complex mineral systems. The Carpentaria province in northern Australia is host to some of the world’s highest value Zn-Pb (+Ag, Cu) deposits. The genesis of many of these deposits is controversial, with competing models of single-vs. multi-stage ore formation. In this study, LA-ICP-MS data of paragenetically constrained pyrite from the George Fisher Zn-Pb-Ag deposit has been analysed to investigate the chemistry of different stages of ore formation. Pyrite from correlative unmineralized host rocks has also been analysed to investigate evidence of distal hydrothermal anomalism. All LA-ICP-MS data have been statistically evaluated (principal component analysis) and interpreted together with whole rock lithogeochemical data of the same samples. Pre-ore diagenetic pyrite is compositionally similar to other Proterozoic diagenetic pyrite, with some evidence of minor hydrothermal anomalism that with further analysis could help define distal alteration. Pyrite from the different ore stages are compositionally distinct, consistent with a multi-stage system. Ore stage 1 pyrite exceeds background contents of Co, Cu, Zn, As, Ag, Sb, Tl, and Pb and has elevated Co/Ni ratios, whereas only Ni and Co are above background abundances in ore stage 2 and 3 pyrite, of which only ore stage 3 pyrite has high Co/Ni ratios. Ore stage 1 pyrite has a similar composition to hydrothermal pyrite in the undeformed northern Carpentaria CD-type deposits and was likely syn-diagenesis. Ore stage 2 was syn-deformation, and resulted in replacement and recrystallization of pre-existing pyrite, and the expulsion of incompatible TEs. Ore stage 3 formed via a later Cu-Zn-Pb mineralizing event that resulted in a new geochemically distinct generation of Co-rich pyrite. Overall, this study demonstrates the value of paragenetically-constrained pyrite TE data for refining genetic models in complex sediment hosted mineral systems.