Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (2083)
- Beitrag zu einem Tagungsband (386)
- Forschungsbericht (19)
- Beitrag zu einem Sammelband (10)
- Sonstiges (10)
- Buchkapitel (9)
- Corrigendum (3)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Dissertation (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (2287)
- Deutsch (233)
- Mehrsprachig (3)
- Portugiesisch (1)
Schlagworte
- Additive manufacturing (69)
- Fluorescence (56)
- Nanoparticles (48)
- Concrete (47)
- SAXS (46)
- Ultrasound (38)
- Corrosion (37)
- MALDI-TOF MS (36)
- Quantum yield (36)
- Non-destructive testing (34)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (448)
- 6 Materialchemie (442)
- 1 Analytische Chemie; Referenzmaterialien (362)
- 7 Bauwerkssicherheit (228)
- 5 Werkstofftechnik (218)
- 9 Komponentensicherheit (215)
- 4 Material und Umwelt (197)
- 6.3 Strukturanalytik (168)
- 8.5 Röntgenbildgebung (139)
- 6.1 Oberflächen- und Dünnschichtanalyse (102)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (101)
- 8.0 Abteilungsleitung und andere (100)
- 5.1 Mikrostruktur Design und Degradation (80)
- 9.3 Schweißtechnische Fertigungsverfahren (79)
- 1.2 Biophotonik (74)
- 6.6 Physik und chemische Analytik der Polymere (70)
- 9.4 Integrität von Schweißverbindungen (69)
- 8.4 Akustische und elektromagnetische Verfahren (66)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (64)
- 6.2 Material- und Oberflächentechnologien (63)
- 1.1 Anorganische Spurenanalytik (61)
- 7.4 Baustofftechnologie (61)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (57)
- 1.4 Prozessanalytik (56)
- 4.1 Biologische Materialschädigung und Referenzorganismen (56)
- 1.7 Organische Spuren- und Lebensmittelanalytik (55)
- 3 Gefahrgutumschließungen; Energiespeicher (54)
- 1.5 Proteinanalytik (52)
- 6.0 Abteilungsleitung und andere (51)
- 8.6 Faseroptische Sensorik (50)
- 1.8 Umweltanalytik (43)
- 4.3 Schadstofftransfer und Umwelttechnologien (42)
- 5.2 Metallische Hochtemperaturwerkstoffe (42)
- 7.2 Ingenieurbau (40)
- 1.9 Chemische und optische Sensorik (38)
- 5.4 Multimateriale Fertigungsprozesse (38)
- 9.0 Abteilungsleitung und andere (35)
- 9.2 Versuchsanlagen und Prüftechnik (32)
- 4.2 Material-Mikrobiom Wechselwirkungen (30)
- 5.3 Polymere Verbundwerkstoffe (29)
- 2 Prozess- und Anlagensicherheit (28)
- 4.0 Abteilungsleitung und andere (28)
- 4.5 Kunst- und Kulturgutanalyse (28)
- 5.5 Materialmodellierung (27)
- 5.6 Glas (27)
- S Qualitätsinfrastruktur (27)
- 7.6 Korrosion und Korrosionsschutz (26)
- 2.1 Sicherheit von Energieträgern (25)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (24)
- 9.5 Tribologie und Verschleißschutz (23)
- 9.6 Additive Fertigung metallischer Komponenten (23)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (22)
- VP Vizepräsident (22)
- VP.1 eScience (22)
- 7.1 Baustoffe (21)
- 1.3 Instrumentelle Analytik (19)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (17)
- 5.0 Abteilungsleitung und andere (17)
- 1.6 Anorganische Referenzmaterialien (16)
- S.2 Digitalisierung der Qualitätsinfrastruktur (16)
- 7.7 Modellierung und Simulation (15)
- 1.0 Abteilungsleitung und andere (13)
- 7.0 Abteilungsleitung und andere (13)
- P Präsident (11)
- 3.2 Gefahrguttanks und Unfallmechanik (10)
- 3.5 Sicherheit von Gasspeichern (10)
- P.0 Präsident und andere (10)
- 6.7 Materialsynthese und Design (9)
- 7.3 Brandingenieurwesen (9)
- 6.4 Materialinformatik (8)
- 3.4 Sicherheit von Lagerbehältern (7)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (7)
- 3.6 Elektrochemische Energiematerialien (6)
- S.1 Qualität im Prüfwesen (5)
- 3.0 Abteilungsleitung und andere (4)
- 8.3 Thermografische Verfahren (4)
- 4.6 Molekulare und angewandte Entomologie (3)
- 2.0 Abteilungsleitung und andere (2)
- 2.2 Prozesssimulation (2)
- 2.3 Einstufung von Gefahrstoffen und -gütern (1)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (1)
- 3.3 Sicherheit von Transportbehältern (1)
- KM Kommunikation, Marketing (1)
- PST Präsidiale Stabsstelle (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (68)
This paper gives a brief overview on3D imaging of magnetic domains with shearing grating neutron tomography. We investigated the three-dimensional distribution of magnetic domain walls in the bulk of a wedge-shaped FeSi single crystal. The width of the magnetic domains wasanalyzed at different locations within the crystal. Magnetic domains close to the tip of the wedge are much smaller than in the bulk. Furthermore, the three-dimensional shape of individual domains wasinvestigated. We discuss prospects and limitations of the applied measurement technique.
High resolution examination of safety-relevant parts in immersion tank testing with focussing probes is forming a main topic of modern non-destructive testing. For the usage of complex reconstruction methods and algorithms, an individual and detailed knowledge about the transmission behaviour of the used probes is essential, as this has a significant influence on the results of data reconstruction.
Especially the knowledge about position and diameter of the focal point is needed to achieve the highest possible sensitivity. Through the individual position of the beam axis within the examined volume, a four dimensional metro logical determination of the acoustical pressure (x, y, z, t) is necessary. With the measured data it is possible to draw interferences about the sound field and acoustical pressure distribution. The presented work realized a method of automatic determination of the beam axis, the position of focal point and the focal diameter to support individual testing setups and transducer characterization.
Melt flow and dripping of the pyrolysing polymer melt can be both a benefit and a detriment during a fire. In several small-scale fire tests addressing the ignition of a defined specimen with a small ignition source, well-adjusted melt flow and dripping are usually beneficial to pass the test. The presence of flame retardants often changes the melt viscosity crucially. The influence of certain flame retardants on the dripping behaviour of four commercial polymers, poly(butylene terephthalate) (PBT), polypropylene (PP), polypropylene modified with ethylene-propylene rubber (PP-EP) and polyamide 6 (PA 6), is analysed based on an experimental monitoring of the mass loss due to melt dripping, drop size and drop temperature as a function of the furnace temperature applied to a rod-shaped specimen. Investigating the thermal transition (DSC), thermal and thermo-oxidative decomposition, as well as the viscosity of the polymer and collected drops completes the investigation. Different mechanisms of the flame retardants are associated with their influence on the dripping behaviour in the UL 94 test. Reduction in decomposition temperature and changed viscosity play a major role. A flow limit in flame-retarded PBT, enhanced decomposition of flame-retarded PP and PP-EP and the promotion of dripping in PA 6 are the salient features discussed.
This paper reflects recent progress in the field of fluorescent polymer optical fiber sensors (F-POF) for partial discharge (PD) detection in high voltage (HV) cable accessories using optical-only PD detection by coincidence single photon counting. In experiments with artificial PD sources these sensors show the ability to detect optical emissions from picocoulomb-level PDs in a real-scale model of a translucent high voltage cable accessory. False positives (caused by detector noise) are efficiently suppressedwhile maintaining sufficient sensitivity,even when the sensor is located in an unfavorable position.
N-Hydroxysuccinimide (NHS) esters are the most important activated esters used in many different bioconjugation techniques, such as protein labelling by fluorescent dyes and enzymes, surface activation of chromatographic supports, microbeads, nanoparticles, and microarray slides, and also in the chemical synthesis of peptides. Usually, reactions with NHS esters are very reliable and of high yield, however, the compounds are sensitive to air moisture and water traces in solvents. Therefore, the quantification of NHS would be a very helpful approach to identify reagent impurities or degradation of stored NHS esters. No robust and sensitive method for the detection of NHS (or the more hydrophilic sulfo-NHS) has been reported yet. Here, a chromatographic method based on HILIC conditions and UV detection is presented, reaching a detection limit of about 1 mg L-1, which should be sensitive enough for most of the applications mentioned above. Exemplarily, the hydrolytic degradation of a biotin-NHS ester and a purity check of a fluorescent dye NHS ester are shown. An important advantage of this approach is its universality, since not the structurally variable ester compound is monitored, but the constant degradation product NHS or sulfo-NHS, which avoids the necessity to optimize the separation conditions and facilitates calibration considerably.
Für eine hochauflösende Untersuchung von sicherheitsrelevanten Bauteilen innerhalb der Tauchtechnik haben fokussierende Prüfköpfe eine hohe Verbreitung erlangt. Für den Einsatz moderner und komplexer Rekonstruktionsverfahren bildet jedoch die Kenntnis über Schallfeldgeometrie, insbesondere die Lage und Ausdehnung der Fokusbereichs und die Empfindlichkeit des verwendeten Prüfkopfs in Abhängigkeit zum Schallweg, eine entscheidende Rolle für die Datenrekonstruktion und die abschließende Bauteildiagnose.
Für die automatisierte Bestimmung der wichtigsten Kenngrößen (bspw. Lage und Länge des Fokuspunkts bzw. Fokusschlauchs, sowie des Schallbündel-durchmessers) wurde die Schalldruckverteilung mechanisiert, vierdimensional (x,y,z,t) vermessen und unter Einsatz der digitalen Signal- und Bildverarbeitung, ein vollautomatisches Analysewerkzeug erarbeitet. Weiterhin konnte anhand des Messdatensatzes und unter Einsatz von dreidimensionalen Rekonstruktions- und Visualisierungstechniken das Schallfeld bzw. die Schalldruckverteilung dreidimensional abgebildet werden und für etwaige Nachuntersuchungen von Simulationsergebnissen oder allein zur Visualisierung eingesetzt werden.
Für den stetigen Einsatz und die erhöhten Anforderungen bei der mechanisierten Prüfung sowie in der Handprüfung ist notwendig, einen möglichst genauen Eindruck bzgl. Funktionsweise und Zuverlässigkeit der eingesetzten Prüfmittel zu besitzen. Prüfköpfe weisen, wie jedes andere technische Erzeugnis gewisse Toleranzen hinsichtlich Fertigungs- und Alterungsprozessen auf, welche sich speziell bei Winkelprüfköpfen durch eine Verschiebung des Nominalwinkels äußern können. Die Definition der Parameter von Prüfköpfen und entsprechende Methoden zu deren Überprüfung sind in der DIN EN 12668-2 geregelt.
Von der BAM werden für diese Aufgaben Richtcharakteristikmessplätze eingesetzt. Um auf die gestiegenen Anforderungen hochauflösender Prüfungen zu reagieren wurde der Richtcharakteristikmessplatz modernisiert. Dabei wurde für die teil-automatisierte Untersuchung der akustischen Parameter (z.B. Einschallwinkel) unter Verwendung digitaler Messdatenverarbeitung - ein neuer Messplatz für die Überprüfung sowie Untersuchung von Prüfkopftoleranzen und Alterungsprozessen realisiert. Der Messplatz verfügt über eine hochauflösende Messdatenerfassung sowie einer automatisierten Protokollierung der erhobenen Messdaten.
In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study.
In carrier gas hot extraction the calibration of low amounts of non-metals with masses of a few micrograms with small uncertainty remains a challenge. To achieve high flexibility a high precision gas mixture pump was combined with an automated syringe drive. The gas mixing pump allows filling the syringe with different gas compositions; the automated syringe drive allows matching to modulate the signal profiles to those of real samples. The system was designed and its experimental potential explored. The resulting calibration curves were comparable to those obtained by calibration using solid materials of sufficient purity and stoichiometry. However smaller uncertainties and lower limits of quantification (i.e. 0.5 µg and 0.6 µg for O and N, respectively) were found using the gas calibration device.
Characterization of silver nanoparticles in cell culture medium containing fetal bovine serum
(2015)
Nanoparticles are being increasingly used in consumer products worldwide, and their toxicological effects are currently being intensely debated. In vitro tests play a significant role in nanoparticle risk assessment, but reliable particle characterization in the cell culture medium with added fetal bovine serum (CCM) used in these tests is not available. As a step toward filling this gap, we report on silver ion release by silver nanoparticles and on changes in the particle radii and in their protein corona when incubated in CCM. Particles of a certified reference material, p1, and particles of a commercial silver nanoparticle material, p2, were investigated. The colloidal stability of p1 is provided by the surfactants polyethylene glycol-25 glyceryl trioleate and polyethylene glycol-20 sorbitan monolaurate, whereas p2 is stabilized by polyvinylpyrrolidone. Dialyses of p1 and p2 reveal that their silver ion release rates in CCM are much larger than in water. Particle characterization was performed with asymmetrical flow field-flow fractionation, small-angle X-ray scattering, dynamic light scattering, and electron microscopy. p1 and p2 have similar hydrodynamic radii of 15 and 16 nm, respectively. The silver core radii are 9.2 and 10.2 nm. Gel electrophoresis and subsequent peptide identification reveal that albumin is the main corona component of p1 and p2 after incubation in CCM that consists of Dulbecco's modified Eagle medium with 10% fetal bovine serum added.
The color X-ray camera SLcam® is a full-field, single photon detector providing scanning-free, energy and spatially resolved X-ray imaging. Spatial resolution is achieved with the use of polycapillary optics guiding X-ray photons from small regions on a sample to distinct energy dispersive pixels on a charged-coupled device detector. Applying sub-pixel resolution, signals from individual capillary channels can be distinguished. Therefore, the SLcam® spatial resolution, which is normally limited to the pixel size of the charge-coupled device, can be improved to the size of individual polycapillary channels. In this work a new approach to a sub-pixel resolution algorithm comprising photon events also from the pixel centers is proposed. The details of the employed numerical method and several sub-pixel resolution examples are presented and discussed.
A user-friendly open-source Monte Carlo regression package (McSAS) is presented, which structures the analysis of small-angle scattering (SAS) using uncorrelated shape-similar particles (or scattering contributions). The underdetermined problem is solvable, provided that sufficient external information is available. Based on this, the user picks a scatterer contribution model (or 'shape') from a comprehensive library and defines variation intervals of its model parameters. A multitude of scattering contribution models are included, including prolate and oblate nanoparticles, core-shell objects, several polymer models, and a model for densely packed spheres. Most importantly, the form-free Monte Carlo nature of McSAS means it is not necessary to provide further restrictions on the mathematical form of the parameter distribution; without prior knowledge, McSAS is able to extract complex multimodal or odd-shaped parameter distributions from SAS data. When provided with data on an absolute scale with reasonable uncertainty estimates, the software outputs model parameter distributions in absolute volume fraction, and provides the modes of the distribution (e.g. mean, variance etc.). In addition to facilitating the evaluation of (series of) SAS curves, McSAS also helps in assessing the significance of the results through the addition of uncertainty estimates to the result. The McSAS software can be integrated as part of an automated reduction and analysis procedure in laboratory instruments or at synchrotron beamlines.
Fire and explosion hazards associated with storage and transportation of flammable materials have been a matter of great interest in the recent times. BLEVE is a scenario that occurs when a closed fuel container is subjected to heat for a longer duration. Such events are disastrous to human beings and assets both. In the past there have been numerous studies on BLEVEs and fireballs of hydrocarbon fuels, e.g. kerosene, gasoline, LPG, LNG and others. Though, the fireballs of peroxy-fuels are not looked into detail as such. This article tries to overcome this lack of knowledge. Both, experimental investigation and CFD simulations are performed to measure and predict the fireball characteristics of a peroxy-fuel. Due to thermal decomposition in the liquid phase and active oxygen content a peroxy-fuel fireball burns at a very fast rate and emit higher thermal radiation whereas exhibits smaller diameter and elevation compared to hydrocarbons. That eventually leads to consideration of larger safety distances from them which are also verified by CFD results.
Temperature-memory polymers are able to generate a substantial mechanical response when heated above the temperature, at which a preceding deformation was carried out. Here we show how to design the temperature-memory effect (TME) by thermomechanical treatment. As a model polymer, phase segregated poly(ester urethane) (PEU) containing crystallizable segments of poly(1,4-butylene adipate) (PBA) was used. For programming, strain elongation was applied at temperatures within the PBA melting transition area, before temperature holding, unloading and cooling were carried out. Upon heating under stress-free or constant strain recovery conditions, precisely set temperature-memory onsets could be witnessed. Most importantly, strain fixities and recoverabilities the same as maximum recovery stresses turned out to be controllable by strain rate and temperature holding time after deformation, while transition temperatures remained largely unaffected. The tailoring of thermoresponsiveness was structurally enabled by different PBA crystallinities in the programmed state as verified by wide-angle X-ray scattering (WAXS). The reported studies intend to design TMEs in semicrystalline polyurethanes according to user-defined needs to make this technology broadly applicable.
Für die Durchführung einer Dichtheitsprüfung und für die Bewertung des Ergebnisses ist es wichtig, den sich unter Betriebsbedingungen im Prüfobjekt einstellenden Überdruck zu kennen. Entspricht der Prüfüberdruck nicht dem Betriebsüberdruck, so ist es oft erforderlich, die unter Prüfbedingungen gemessenen Leckageraten auf den realen Betriebsüberdruck umzurechnen. Im Bereich der Gefahrgutverpackungen ist jedoch der spätere maximale Betriebsüberdruck nicht genau bekannt. Er hängt für jede einzelne Verpackungsbauart von dem eingefüllten Füllmedium mit seinen spezifischen Stoffeigenschaften, dem Füllgrad sowie den Beförderungsbedingungen, insbesondere der mittleren Transporttemperatur, ab. Es werden Berechnungsansätze vorgestellt, mit denen sich der Überdruck in Gefahrgutverpackungen unter Beförderungsbedingungen rechnerisch ermitteln lässt. Die theoretisch berechneten Überdrücke werden mit Überdruck-Messwerten verglichen, die mit verschiedenen Füllmedien in unterschiedlichen Verpackungsbauarten ermittelt wurden.
Geosynthetics are planar polymeric products, which are used in connection with soil, rock or other soil-like materials to fulfill various functions in geoenvironmental engineering. Geosynthetics are of ever-growing importance in the construction industry. Sealing of waste storage facilities to safely prevent the emission of wastewater, landfill gas and contaminated dust as well as the diffusion of pollutants into the environment and coastal protection against storms and floods and reconstruction after natural disaster are important fields of application. We will give an overview of the various geosynthetic products. Two examples of the material problems related to geosynthetics are discussed in detail: the effect of creep on the long-term performance of geocomposite drains and the numerical simulation of the interaction of soil with geogrids. Both issues are of importance for the use of these products in landfill capping systems. The various functions, which geosynthetics may fulfill in the protection of coastal lines, are illustrated by case studies. The geosynthetic market is evaluated and economical and environmental benefits, as well as environmental side effects related to the use of geosynthetics, are discussed.
Durch den Einsatz von faserverstärkten Kunststoffen und Multi-Material-Konstruktionen zur Gewichtsreduzierung erlangen Klebeverbindungen immer stärkere Bedeutung. Die Prüfung dieser Fügeverbindungen stellt neue Anforderungen an die zerstörungsfreie Prüfung. Hinzu kommt, dass die Zugänglichkeit häufig eingeschränkt und die Verwendung flüssiger Koppelmittel aufgrund konstruktiver oder fertigungstechnischer Gegebenheiten ausgeschlossen ist. Unter Berücksichtigung dieser Beschränkungen wurde ein Prüfverfahren entwickelt, das eine luftgekoppelte Anregung geführter Ultraschallwellen mit einer laserbasierten Detektion kombiniert. Nachdem das Prüfverfahren zunächst mit einer einfachen Signalauswertung im Zeitbereich getestet wurde, konnte in nachfolgenden Untersuchungen die örtliche Auflösung durch die Implementierung von Filteralgorithmen im Frequenz-Wellenzahl-Bereich und zusätzlich durch direktionale Filter erhöht werden. Das resultierende bildgebende Prüfverfahren wurde an realitätsnahen Klebeproben mit künstlichen Fehlern getestet. Die Zuverlässigkeit und Ortsauflösung des Verfahrens wurde im Vergleich mit herkömmlichen Prüfverfahren validiert. Mithilfe des Verfahrens können Poren, Einschlüsse und Bereiche mit ungenügender Verklebung detektiert werden.
Online-Strukturüberwachungssysteme sind eine Möglichkeit, den Anforderungen hinsichtlich Leichtbau und Zuverlässigkeit gleichzeitig gerecht zu werden. Die Integration solcher Systeme liefert aktuelle Informationen über die Integrität der sicherheitsrelevanten Struktur, wodurch sich Aussagen über notwendige Instandhaltungsarbeiten und möglicherweise über die zu erwartende Restlebensdauer ableiten lassen. Der zielgerichtete Einsatz der Überwachungssysteme ermöglicht es somit, die benötigten Sicherheitsfaktoren bei der Auslegung der Bauteile zu reduzieren und Wartungsintervalle zu verlängern. Dadurch können Kosten gesenkt werden, ohne die Zuverlässigkeit zu verringern. Im Rahmen einer Studie zur Machbarkeit eines Online-Überwachungssystems für Eisenbahn-Radsatzwellen wurde der Einsatz geführter Ultraschallwellen, die von Sensoren an einer Stirnseite der Wellen angeregt werden, demonstriert. Aufgrund der Bauteilgeometrie und der dispersiven, multimodalen Wellenausbreitung stellt die Interpretation der Echosignale eine wesentliche Herausforderung dar. Basierend auf dem a-priori-Wissen über die Wellenausbreitung wurden in der Studie klassifizierende Auswertealgorithmen entwickelt und erfolgreich an maßstabsgetreuen Labormodellen getestet.
Hochduktiler Beton eröffnet neue Möglichkeiten bei der Instandsetzung von Bauwerken, der Herstellung dünnwandiger Bauelemente oder dem Einsatz von Dämpfungselementen in stoßartig beanspruchten Bauwerken (z.B. in Erdbebengebieten).
Die Steigerung der Duktilität kann durch die Zugabe von Kurzfasern erreicht werden. Im Falle einer Rissbildung in der Zementsteinmatrix überbrücken die Fasern den Riss, nehmen die Spannung vollständig auf und stoppen lokal das Risswachstum. Bei weiterer Steigerung der Last reißt die Matrix an anderer Stelle. Auf diese Weise wird die Rissbildung fein verteilt und es werden große Dehnungen erreicht, bevor das Bauteil versagt. Zur Optimierung der Festbetoneigenschaften müssen die Matrixfestigkeit und die Faserart sowie deren Gehalt aufeinander abgestimmt werden. Dabei sind auch die Verarbeitungseigenschaften des Frischbetons zu berücksichtigen.
Anhand der Schallemissionen kann die Rissbildung in der Matrix und die Interaktion mit den Fasern analysiert werden. So konnte in ersten Zugversuchen gezeigt werden, dass sich Schallereignisse dem Versagen der Zementsteinmatrix bzw. dem Auszug der Fasern aus der Matrix zuordnen lassen. Damit steht zur Beurteilung des mechanischen Verhaltens von hochduktilem Beton neben der Spannungs-Dehnungs-Linie ein weiteres Verfahren zur Verfügung.
Quantifying degradation of collagen in ancient manuscripts: the case of the Dead Sea Temple Scroll
(2013)
Since their discovery in the late 1940s, the Dead Sea Scrolls, some 900 ancient Jewish texts, have never stopped attracting the attention of scholars and the broad public alike, because they were created towards the end of the Second Temple period and the 'time of Christ'. Most of the work on them has been dedicated to the information contained in the scrolls' text, leaving physical aspects of the writing materials unexamined. They are, however, crucial for both historical insight and preservation of the scrolls. Although scientific analysis requires handling, it is essential to establish the state of degradation of these valued documents. Polarized Raman Spectroscopy (PRS) is a powerful tool for obtaining information on both the composition and the level of disorder of molecular units. In this study, we developed a non-invasive and non-destructive methodology that allows a quantification of the disorder (that can be related to the degradation) of protein molecular units in collagen fibers. Not restricted to collagen, this method can be applied also to other protein-based fibrous materials such as ancient silk, wool or hair. We used PRS to quantify the degradation of the collagen fibers in a number of fragments of the Temple Scroll (11Q19a). We found that collagen fibers degrade heterogeneously, with the ones on the surface more degraded than those in the core.