Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2018 (63) (entfernen)
Dokumenttyp
Schlagworte
- Concrete (5)
- Air-coupled ultrasonic testing (4)
- NDT (4)
- Simulation (4)
- Ultraschall (4)
- Zerstörungsfreie Prüfung (4)
- Additive manufacturing (3)
- Beton (3)
- Composites (3)
- Ferroelectret (3)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (63) (entfernen)
The detection of cracks before the failure is highly significant when it comes to safety-relevant structures. Crack detection in metallic samples at high surface temperature is one of the challenging situation in manufacturing industries.
Laser thermography has already proved its detection capability of surface cracks in metallic samples at room temperature. In this work a continuous wave (CW) laser use to generate a laser, which is using to scan the metal surface with notch.
The corresponding heat distribution on the surface monitored using infrared thermal (IR) camera. A simplified 3D model for laser thermography is developed and validated with experimental results. A dedicated image processing algorithm developed to improve the detectability of the cracks. To understand the dependency of surface temperature, laser power, laser scanning speed etc. in defect detection, we carried out parametric studies with our validated model. Here we Report the capability of laser thermography in crack detection at elevated temperature.
A novel approach for rating fatigue-initiating inclusions in highly demanding steel (INCAFAT)
(2018)
INCAFAT project aimed to improve existing fatigue damage models by establishing the most suitable combination of measurement techniques to characterise harmful inclusion populations in highly demanding steels. The different inclusion assessments carried out confirm that, chemical composition, secondary metallurgy and manufacturing route affect content, nature, size and shape of inclusions. According to the FEM model, inclusions produce an alteration of the stress field in their surrounding region, which can promote a fatigue failure. Experimental work on fatigue testing has demonstrated that depending on the stressed direction fatigue failures in highly demanding steels could be produced by different types of inclusions. Fractography analyses confirmed that meso-inclusions harmful in fatigue cannot be rated by standard methods, nor 10 MHz ultrasonic testing (macro) or micro-cleanness assessments. The necessity of rating these meso-inclusions has led to critical evaluation of Extreme Value Analysis according to ASTM E2283-08 and the development of high frequency immersion ultrasonic testing. EVA methodology based on inclusion width can be applied reliably when principal stress is parallel to the rolling direction. On the contrary, if inclusions are testing in the elongated directions its fails. On the other hand, the guidelines and recommendations for high frequency ultrasonic testing have been compiled in a new European standard draft. This method based on focal beam probes and high-resolution devices is able to provide information on meso-inclusion distribution.
Die Simulation von Ultraschallausbreitung ist ein wesentliches Hilfsmittel zur Optimierung von Prüfanordnungen und wird zunehmend in der Prüfvorbereitung eingesetzt. Eisenbahnschienen sind Bauteile mit komplexer Geometrie und im eingebauten Zustand eingeschränkter Zugänglichkeit. Bei der Prüfung im Feld entstehen aus der Schienengeometrie komplexe Echosignale mit Formanzeigen, die schwer zu interpretieren sind.
Für das bessere Verständnis der Schallausbreitung in der Eisenbahnschiene wird diese in einem ersten Schritt mit Hilfe verschiedener Ansätze modelliert. Hierbei werden Finite Elemente Methoden und semi-analytischen Modelle verwendet. In einem zweiten Schritt werden die Ergebnisse der Simulationsmodelle einander gegenübergestellt und mit Messungen an realen Schienen verglichen.
Ziel dieser Untersuchungen ist die Validierung von Simulationsverfahren mit Hilfe von Messdatensätzen und Überprüfung der Anwendbarkeit bei der Bewertung von Ergebnissen der Schienenprüfung.
Spektren von gepulsten Röntgenquellen wie Blitzröhren, Linearbeschleuniger (LINACs) oder Betatrons lassen sich in der Literatur nicht finden. Eine gängige Lehrmeinung ist, dass sich solche Spektren nicht messen lassen. Deshalb wurden in Zusammenarbeit mit der Goethe-Universität Frankfurt und neuester Messtechnik diese Problematik untersucht. Es wurde ein CeBr3-Szintillator-Kristall mit einem klassischen Photoelektronenvervielfacher (PMT) und einer analogen Übertragungskette verwendet, der über Stunden Integrationszeit nur einen sehr geringen Untergrund detektiert. Als kritischter Punkt stellte sich die geeignete Kollimierung von Quelle und Detektor bei möglichst großem Abstand heraus. Zu diesem Zweck wurde das verwendete 7 MeV-Betatron in einen 3t-Bleibunker betrieben, der ein Austrittsloch von 1 mm für die erzeugte Röntgenstrahlung besaß. Der Detektor wurde mit einem Densimet-Zylinder abgeschirmt. Damit konnte die Bedingung für die Spektroskopie gepulster Quellen erreicht werden: pro Puls darf nur 1 Photon den Detektorkristall erreichen, damit ohne Pile-up seine Energie vermessen werden kann. Trotz schnellster Elektronik war es nicht möglich, mehere Photonen pro Röntgenpuls (beim Betatron ca. 1 Mikrosekunde) spektral richtig aufzulösen. Die gemessenen Spektren zeigen die erwartete Form, wie sie z.B. mit aRTist simuliert werden können.
Die Voraussetzungen für die Vorhersage der Sichtbarkeit von Bildgüteprüfkörpern (BPK) wurden seit Beginn der kommerziellen Anwendung der technischen Radiographie diskutiert und in diversen nationalen und internationalen Standards festgeschrieben. Diese Fragen werden nach Einführung der digitalen Radiographie und der CT wieder neu diskutiert. Draht BPKs wurden in Deutschland seit 1935 (DIN 1915: 1935) und später in den meisten europäischen Ländern benutzt. In den USA und Frankreich wurden vorzugsweise BPKs mit Löchern verwendet (ASTM E 1025 seit 1984 oder E 1742 seit 1992 bzw. die Vorgängernorm MIL STD-543 seit 1962). Jetzt werden auch die Umrechnungsnormen zur Erkennbarkeit von Draht zu Loch-BPKs in Frage gestellt. ISO 19232-3, der französische RCCM-Kode einerseits und ASTM E 747 und ASME BPVC Section V Tab. T-276 andererseits unterscheiden sich erheblich bei den Anforderungen im Bereich hoher Wandstärken (Hochenergieradiographie). Untersuchungen dazu werden vorgestellt. Mit Einführung der digitalen Detektoren ändern sich auch die Rauschspektren. Durch die Herstellung werden insbesondere bei Speicherfolien "Rauschmuster" eingeprägt, die bei hohen Belichtungsdosen sichtbar werden. Diese veränderten Rauschspektren ergeben auch veränderte Erkennungsparameter für menschliche Bildauswerter. Hierzu wurden an ausgewählten Detektoren MTFs (presampled) und normierte Rauschspektren gemessen. Erweiterte Erkennbarkeits-Formeln zur Vorhersage der Sichtbarkeit von BPKs für Bildauswerter und erste Ergebnisse werden vorgestellt.
Digital radiographic images were analysed to predict the visibility of image quality indicators (IQI), based on normalized noise power spectra (NNPP) and modulation transfer function (MTF) measurements. The fixed pattern noise of some digital detectors result in different noise spectra, which influence the visibility of different IQIs, depending on the hole diameter. Studies, based on measurement of basic spatial resolution and contrast to noise ratio were performed together with presampled MTF measurements and the NNPS in dependence on the spatial frequency. Plate hole IQIs, step hole IQIs, and equivalent penetrameter sensitivity (EPS) IQIs based on ASTM E 746 were measured to verify the influence of the different parameters. Modelling of digital images was used to verify the applied numeric tools. A study has been performed for imaging plates and digital detector arrays to analyse differences. Formulas for the prediction of the visibility functions for hole type IQIs are derived. In consequence the standards for characterization and classification of computed radiography (ASTM E 2446) and radiography with DDAs (ASTM E 2597) need to be revised.
Strong coupling effects in magnetocaloric materials are the key factor to achieve a large magnetic entropy change. Combining insights from experiments and ab initio calculations, we review relevant coupling phenomena, including atomic coupling, stress coupling, and magnetostatic coupling. For the investigations on atomic coupling, we have used Heusler compounds as a flexible model system. Stress coupling occurs in first‐order magnetocaloric materials, which exhibit a structural transformation or volume change together with the magnetic transition. Magnetostatic coupling has been experimentally demonstrated in magnetocaloric particles and fragment ensembles. Based on the achieved insights, we have demonstrated that the materials properties can be tailored to achieve optimized magnetocaloric performance for cooling applications.
Stahlbetontragwerke sind eine wichtige Konstruktionsweise im Bauwesen und ein wachsendes Anwendungsfeld für die Zerstörungsfreie Prüfung (ZfP).
Zur Sicherung der Tragsicherheit, strukturellen Integrität, Bestimmung von Geometrien und zur Detektion konstruktiver Elemente wie z.B. Bewehrung, Verankerungen und Spannkanälen besitzen zerstörungsfreie Prüfverfahren in diesem Bereich inzwischen große Relevanz. Durch den bislang erreichten Fortschritt in der Forschung und Entwicklung haben moderne akustische und elektromagnetische Verfahren eine beachtliche Leistungsfähigkeit erreicht. Von Geräteherstellern sind diese in kommerziellen Produktserien umgesetzt worden und finden eine zunehmend breite Anwendung in der Praxis. In einigen anderen Anwendungsgebieten, in denen die ZfP bereits fester Bestandteil von Überwachungen ist, wie z.B. im Maschinenbau und insbesondere in der Kerntechnik und der Luftfahrt, existieren umfangreiche Qualitätssicherungssysteme für die konforme Anwendung und zuverlässige Einbeziehung der ZfP. Dem relativ jungen Entwicklungsstadium moderner ZfP für Stahlbetonbauteile entsprechend müssen solche Konzepte im Bauwesen erst noch entwickelt bzw. implementiert werden.
Dementsprechend hat sich der Unterausschuss Qualitätssicherung (UA- S) des Fachausschusses ZfP im Bauwesen (ZfPBau) die Definition und Verbesserung der Qualität von ZfP-Anwendungen sowie insbesondere die verfahrensunabhängige Standardisierung von Prüfprozeduren und statistische Absicherung der Prüfergebnisse zum Ziel gemacht.
Die aktuellen Arbeitsfelder beinhalten die Entwicklung praxisgerechter Konzepte für Prüfprozeduren und deren Erprobung in einem Ringversuch sowie die Konzeption von Testkörpern hinsichtlich unterschiedlicher Aspekte wie Parameterstudien, Validierung, Kalibrierung und Simulation. Dabei werden Ansätze anderer Branchen durchaus einbezogen, die Anpassung an die spezifischen Bedürfnisse und Gegebenheiten des Bauwesens wird jedoch als wesentlich angesehen und stellt somit eine wichtige Vorgabe dar.
Da die Tätigkeiten nicht auf einzelne Verfahren begrenzt sind, müssen generelle Vorgehensweisen entwickelt werden, die sich auf die jeweiligen Verfahren konkretisieren lassen. Der Vortrag gibt hierzu erste Einblicke in die Arbeit des Ausschusses.
Sandwich-Schalenstrukturen in situ charakterisiert mit Thermographie und Felddehnungsmessungen
(2018)
An der BAM wurde ein Schalenprüfstand entwickelt, mit dem typische Sandwichschalenstrukturen unter simulierter Betriebsbeanspruchung belastet werden können. Im mechanischen Ermüdungsversuch wurden in situ die Entstehung von Schäden in Schalenprüfkörpern mit Test-Imperfektionen mittels der passiven Thermographie und Felddehnungsmessungen verfolgt. Damit konnten der Zeitpunkt, der Schadensursprung und der Schadensfortschritt zerstörungsfrei bestimmt werden. Zudem wurden vergleichend Schalenprüfkörper mit Luftultraschall und der Röntgen-Laminographie untersucht. Im Rahmen eines BMWi-Forschungsvorhabens wurden die Schädigungsmechanismen evaluiert und Empfehlungen für die Praxis der Fertigung von Rotorblättern abgeleitet. In diesem Beitrag wird sich auf die Darstellung der ZfP-Verfahren und der ZfP-Ergebnisse konzentriert.
Seismic interferometry (SI) deals either with the sensible detection of changes in the subsurface or with the reconstruction of virtual signals between two receivers by crosscorrelation of signals from diffuse sources. These concepts can be applied in NDT in civil engineering for various purposes, e. g. to detect changes in bridges. Here it is demonstrated using data from a reference structure on our test site. Practical applications can be expected in the very near future.
Reliability assessment of existing bridge constructions based on results of non-destructive testing
(2018)
The non-destructive testing methods available for civil engineering (NDT-CE) enable the measurements of quantitative parameters, which realistically describe the characteristics of existing buildings. In the past, methods for quality evaluation and concepts for validation expanded into NDT-CE to improve the objectivity of measured data. Thereby, a metrological foundation was developed to collect statistically sound and structurally relevant information about the inner construction of structures without destructive interventions. More recently, the demand for recalculations of structural safety was identified. This paper summarizes a basic research study on structural analyses of bridges in combination with NDT. The aim is to use measurement data of nondestructive testing methods as stochastic quantities in static calculations. Therefore, a methodical interface between the guide to the expression of uncertainty in measurement and probabilistic approximation procedures (e.g. FORM) has been proven to be suitable. The motivation is to relate the scientific approach of the structural analysis with real information coming from existing structures and not with those found in the literature. A case study about the probabilistic bending proof of a reinforced concrete bridge with statistically verified data from ultrasonic measurements shows that the measuring results fulfil the requirements concerning precision, trueness, objectivity and reliability.
Common air-coupled transducers for non-destructive testing consist of a piezocomposite material and several matching layers. Better acoustical matching to air is achieved by transducers based on charged cellular polypropylene (PP). This material has about hundred times lower acoustic impedance than any piezocomposite, having about the same piezoelectric coefficient. The piezoelectric properties of cellular PP are caused by the polarization of air cells. Alternatively, a ferroelectret receiver can be understood as a capacitive microphone with internal polarization creating permanent internal voltage. The sensitivity of the receiver can be increased by applying additional bias voltage. We present an ultrasonic receiver based on cellular PP including a high-voltage module providing bias voltage up to 2 kV. The application of bias voltage increased the signal by 12 to 15 dB with only 1 dB increase of the noise.
This receiver was combined with a cellular PP transmitter in through transmission to inspect several test specimens consisting of glass-fiber-reinforced polymer face sheets and a porous closed-cell PVC core. These test specimens were inspected before and after load. Fatigue cracks in the porous PVC core and some fatigue damage in the face sheets were detected. These test specimens were originally developed to emulate a rotor blade segment of a wind power plant. Similar composite materials are used in lightweight aircrafts for the general aviation. The other inspected test specimen was a composite consisted of glass-fiber-reinforced polymer face sheets and a wooden core. The structure of the wooden core could be detected only with cellular PP transducers, while commercial air-coupled transducers lacked the necessary sensitivity. Measured on a 4-mm thick carbon-fiber-reinforced polymer plate, cellular PP transducers with additional bias voltage achieved a 32 dB higher signal-to-noise ratio than commercial air-coupled transducers.
In this paper perfluorinated graded-index polymer optical fibers are characterized with respect to the influence of relative humidity changes on spectral transmission absorption and Rayleigh backscattering. The hygroscopic and thermal expansion coefficient of the fiber are determined to be CHE = (7.4 +/- 0.1) 10^-6 %r.h.^-1 and CTE = (22.7 +/- 0.3) 10^-6 K^-1, respectively. The influence of humidity on the Brillouin backscattering power and linewidth are presented for the first time to our knowledge. The Brillouin backscattering power at a pump wavelength of 1319 nm is affected by temperature and humidity. The Brillouin linewidth is observed to be a function of temperature but not of humidity. The strain coefficient of the BFS is determined to be CS = (146.5 +/- 0.9) MHz/% for a wavelength of 1319 nm within a strain range from 0.1 % to 1.5 %. The obtained results demonstrate that the humidity-induced Brillouin frequency shift is predominantly caused by the swelling of the fiber over-cladding that leads to fiber straining.
Modern and energy-efficient materials are essential for innovative designs for aerospace and automotive industries. Current technologies for rapid manufacturing such as additive manufacturing and liquid composite moulding by polymer Extrusion allow innovative ways of creating robust and lightweight constructions. Commercially available printing devices often use polylactide (PLA) or acrylonitrile butadiene styrene (ABS) as raw material. Therefore, parameters like the infill ratio, influencing the ability to resist mechanical stress, may have a beneficial impact on the lifetime of components.
These manufacturing technologies require a good knowledge about materials and even adapted non-destructive testing technologies and methods. Airborne ultrasonic testing has beneficial advantages for testing those lightweight constructions. It is a contact-free testing method, which does not require a liquid couplant. Therefore, it allows fast test cycles without any unwanted alternations of the material properties due to interactions with any coupling liquid. This contribution deals with the characterisation of printed specimens based on PLA by using airborne ultrasound and presents the current edge of non-destructive testing and evaluation using airborne ultrasonic transducers. The specimens, manufactured by polymer extrusion, are printed as thin plates. The infill ratio, as well as the material thickness, were varied to model density imperfections with different geometric shapes and properties. For better understanding of the limits of airborne ultrasonic testing in transmission, we compared own-developed transducers based on different physical principles: on ferroelectrets, on the thermoacoustic effect, as well as a new type of transducers based on gas discharges.
We investigate the pore space of rock samples with respect to different petrophysical parameters using various methods, which provide data on pore size distributions, including micro computed tomography (µ-CT), mercury Intrusion porosimetry (MIP), nuclear magnetic resonance (NMR), and spectral-induced polarization (SIP). The resulting cumulative distributions of pore volume as a function of pore size are compared. Considering that the methods differ with
regard to their limits of resolution, a multiple-length-scale characterization of the pore space is proposed, that is based on a combination of the results from all of these methods.
The approach is demonstrated using samples of Bentheimer and Röttbacher sandstone. Additionally, we compare the potential of SIP to provide a pore size distribution with other commonly used methods (MIP, NMR). The limits of Resolution of SIP depend on the usable frequency range (between 0.002 and 100 Hz). The methods with similar Resolution show a similar behavior of the cumulative pore volume distribution in the verlapping pore size range. We assume that µ-CT and NMR provide the pore body size while MIP and SIP characterize the pore throat size. Our study Shows that a good agreement between the pore radius distributions can only be achieved if the curves are adjusted considering the resolution and pore volume in the relevant range of pore radii. The MIP curve with the widest range in Resolution should be used as reference.
Validation of artificial defects for non-destructive testing measurements on a reference structure
(2018)
Non-destructive testing was established over the last decades as an important tool for assessing damages, material characterization and quality assurance in civil engineering. For example, Ground Penetrating Radar (GPR) can be used to scan large areas of concrete structures to determine the spatial position of the reinforcement. With the ultrasonic echo method, the thickness of concrete structures can be easily determined even if a high density of reinforcement is given. Various methods and processes have been developed for the validation of NDT procedures aiming at ensuring the quality of measurements in practical use. The Probability of Detection (POD) for example, is an available method to compare different technical devices with each other quantitatively regarding their performance. With this method, the best suited testing device for a specific inspection task under defined boundary conditions can be selected. By using the Guide to the Expression of Uncertainty in Measurement (GUM), it is possible to quantify the measurement uncertainty of an inspection procedure for a specific task. Another important aspect to improve the acceptance of Non-destructive testing methods is the development of reference specimens.
Reference specimens serve for the calibration and further development of NDT methods under realistic conditions in different laboratories under the same conditions. A particular challenge here is the most realistic representation of a damage that can occur at building sites. Possible damages include for example horizontal and vertical cracks or honeycombs in concrete. Such a reference structure was built for the development of a new design of power plant constructions. Comparative studies on the manufacturing of realistic honeycombs and delaminations were carried out in advance on a test specimen. The results of this study are presented here.
Airborne ultrasonic testing of lightweight, structured composite materials enables fast and contact-free non-destructive testing in aerospace and avoids material degradation due to contact with a coupling liquid. Established resonant air-coupled transducers consist of piezocomposite materials and several matching layers or more advanced materials like charged cellular polypropylene. The relaxation time and the specific frequency of such mechanical ultrasound emitters limit the spectrum of applications for each device. A short pulse length is key for reliable defect detection and each component at test can be best characterized at material- and geometry-specific frequencies. Here we show that focused thermoacoustic transducers are suited for testing lightweight, structured composite plates. Since the ultrasound is generated in air, these transducers show no resonance behavior and emit a broadband acoustic spectrum between 1.2 kHz and 1 MHz. Composite specimens of 3 mm to 9 mm thickness made of polylactide with a honeycomb structure were tested. Flat bottom holes were introduced to quantify the spatial resolution of the imaging method inside the strongly anisotropic specimen. As no broadband receivers are available yet, cellular polypropylene transducers were used as receivers, which limits the bandwidth of the method towards the bandwidth of the receiver. Nevertheless, we demonstrate the competitiveness of the thermoacoustic transducer compared to mechanical emitters at their respective resonance frequencies. Because a thermoacoustic transmitter features a nearly ideal pulse width, a single transmitter can be coupled with receivers with different resonance frequencies. With the development of broadband ultrasound receivers, air-coupled ultrasound spectroscopy will likely be possible in the near future. The analysed transducer holds the potential to speed up testing during production and maintenance in aerospace and automotives. Its combination with a broadband receiver could also expand the application field of air-coupled ultrasonic testing from a qualitative error detection towards a quantitative, spatially resolved analysis of mechanical material properties.
The mechanical stress-strain behaviour of polymer optical fibres (POFs) drawn from various materials was measured, both before and after temperature annealing of the POFs. The POFs were drawn from PMMA (GEHR), Zeonex (480R), PC (Makrolon LED2245) and two different grades of Topas (8007S-04 and 5013S-04). With fibre drawing stresses at or above the elastic (uniaxial extensional) plateau modulus, the polymer chains in the POFs have a high degree of alignment, which has a large impact on fibre mechanical behaviour. The testing was performed at straining rates ranging from 0.011%/s, to 1.1%/s for the un-annealed fibres and a straining rate of 1.1%/s for the annealed ones. The elastic modulus of the tested POFs showed no sensitivity toward variation of straining rate. In the case of Topas 5013S-04 and PMMA, the producer-reported values are the same as the one obtained here for the POFs both before and after annealing. The drawn POFs made of Zeonex, PC, and Topas 8007S-04 exhibit larger elastic modulus than the respective materials in the bulk form. The elastic modulus of these fibres is reduced upon annealing by 10-15%, but still remains above the producer-reported values for the bulk polymers. In the nonlinear elastic region, only the PC POF is statistically unaffected by the changes in the straining rate, while Topas 8007S-04 POF shows insensitivity to the straining rate until 3% strain. All other changes affect the stress-strain curves. The annealing flattens all stress-strain curves, making the fibres more sensitive to yield.
Reliability of NDT is affected by human factors, which have thus far received the least amount of attention in the reliability assessments. With increased use of automation, in terms of mechanised testing (automation-assisted inspection and the corresponding evaluation of data), higher reliability standards are believed to have been achieved. However, human inspectors, and thus human factors, still play an important role throughout this process and the risks involved in this application are unknown. The aim of this study was to explore for the first time the risks associated with mechanised NDT and find ways of mitigating their effects on the inspection performance. Hence, the objectives were to identify and Analyse potential risks in mechanised NDT and devise measures against them. To address those objectives, a risk assessment in form of a Failure Modes and Effects Analysis (FMEA) was conducted. This analysis revealed potential for failure during both the acquisition and evaluation of NDT data that could be assigned to human, technology, and organisation. Since the existing preventive measures were judged to be insufficient to defend the system from identified failures, new preventive measures were suggested.
Four cement-based and four calcium-sulphate-based screed types are investigated. The samples have a diameter of 300 mm and a height of 35 or 70 mm. Up to ten humidity sensors are embedded directly during the concreting of the screed samples. Thus, the humidity over the sample height is monitored during hardening, hydration, evaporation, and oven drying. Furthermore, the screed samples are weighed during every measurement to determine the total mass and the corresponding moisture loss.
To define the pore system precisely, mercury intrusion porosimetry as well as gas adsorption is performed. According to the data, the entire pore volume distribution is known. The measured pore diameters range from 0.8 nm to 100 µm and the total porosity of the examined screeds ranges between 11% and 22%.
Based on these measurement data, moisture transport, pore saturation as well as sorption isotherms and their hysteresis may be calculated quantitatively as described in “Monitoring of the absolute water content in porous materials based on embedded humidity sensors” (Strangfeld and Kruschwitz, 1921).