Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (2086)
- Beitrag zu einem Tagungsband (386)
- Forschungsbericht (19)
- Beitrag zu einem Sammelband (10)
- Sonstiges (10)
- Buchkapitel (9)
- Corrigendum (3)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Dissertation (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (2290)
- Deutsch (233)
- Mehrsprachig (3)
- Portugiesisch (1)
Schlagworte
- Additive manufacturing (69)
- Fluorescence (56)
- Nanoparticles (48)
- Concrete (47)
- SAXS (46)
- Ultrasound (38)
- Corrosion (37)
- MALDI-TOF MS (36)
- Quantum yield (36)
- Non-destructive testing (34)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (448)
- 6 Materialchemie (442)
- 1 Analytische Chemie; Referenzmaterialien (362)
- 7 Bauwerkssicherheit (228)
- 5 Werkstofftechnik (218)
- 9 Komponentensicherheit (215)
- 4 Material und Umwelt (197)
- 6.3 Strukturanalytik (168)
- 8.5 Röntgenbildgebung (139)
- 6.1 Oberflächen- und Dünnschichtanalyse (102)
Paper des Monats
- ja (68)
POD is the most often used approach for the evaluation of the reliability of non-destructive testing methods in critical areas. But especially for those cases the requirements for a sufficient amount of data, adequate type of defects and the statistical requirements are high. The claim for checking these requirements is not new, but never the less often ignored. Especially the large amount of data for critical real defects seems too often to be not really solvable. In this presentation we show an approach to use real defect data with knowledge from former testing results with the same equipment, in a useful adequate way. Furthermore we introduce a method to evaluate the real defect description parameters for the radiographic testing. This approach was used for a joint project with the company POSIVA, which is building a final depository for spent nuclear fuel in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam weld of the copper canister. The copper canister will be used in the deposit as a corrosion barrier within the deposit concept. Through the high sophisticated manufacturing methods of the canister there are almost no material defects, which could be used for reliability evaluation. In this context the idea of Bayesian Updating of the POD with real defect data with former results from artificial defect data was born to get a useful evaluation.
Using the Modular Reliability Model the three different main influencing elements, i.e. intrinsic capability (IC), application parameters (AP) and the human factors (HF), are, in the first instance, investigated separately. The intrinsic capability stands for the pure physical-technological process of the signal detection caused by the waves or the rays from a material defect in the presence of noise (driven by the material and the devices). This intrinsic capability is the upper bound of the possible reliability. Already when measuring this intrinsic capability for thick walled components the original one-parameter POD must be extended to a multiparameter POD, where, in addition to the defect size, a number of additional physical parameters, such as the grain size distribution (or attenuation), defect depth, and angle or surface roughness, must be considered. For real life cycle assessments it is necessary to evaluate the signal response from real defects. The industrial application factors, e.g. coupling conditions, limited accessibility, heat and environmental vibrations, diminish the reliability. The amount of reduction can be determined quantitatively, if the underlying conditions are controlled. In case they are not controlled it is necessary to count for a fluctuation in the reliability in the field anyway. The third group of important influencing factors are the human factors, which do not only cover the individual performance capability of the inspectors but also the design of the working place,the procedure, the teamwork quality, interaction with systems, the organization, and finally, the relationship between the companies involved in the inspection process and to which extend the responsible parties are aware of it. When comparing an “ideal inspection” with a “real inspection” it is worth while to look how the existing practices, rules and standards support reliable testing and where the “delta” is. In the context of vigor, with respect to the industrial end user, it needs to be shown how the level of reliability of NDE, influenced by the different factors, has an impact on acceptance or rejection of safety critical parts.
Quantifying degradation of collagen in ancient manuscripts: the case of the Dead Sea Temple Scroll
(2013)
Since their discovery in the late 1940s, the Dead Sea Scrolls, some 900 ancient Jewish texts, have never stopped attracting the attention of scholars and the broad public alike, because they were created towards the end of the Second Temple period and the 'time of Christ'. Most of the work on them has been dedicated to the information contained in the scrolls' text, leaving physical aspects of the writing materials unexamined. They are, however, crucial for both historical insight and preservation of the scrolls. Although scientific analysis requires handling, it is essential to establish the state of degradation of these valued documents. Polarized Raman Spectroscopy (PRS) is a powerful tool for obtaining information on both the composition and the level of disorder of molecular units. In this study, we developed a non-invasive and non-destructive methodology that allows a quantification of the disorder (that can be related to the degradation) of protein molecular units in collagen fibers. Not restricted to collagen, this method can be applied also to other protein-based fibrous materials such as ancient silk, wool or hair. We used PRS to quantify the degradation of the collagen fibers in a number of fragments of the Temple Scroll (11Q19a). We found that collagen fibers degrade heterogeneously, with the ones on the surface more degraded than those in the core.
Standardisierung der Lockin-Thermografie: Vorstellung des TNS-Projektes und Auswahl der Probekörper
(2013)
Ziel des Verbundprojektes zwischen der BAM und dem IKT der Universität Stuttgart ist die Festlegung einer einheitlichen Vorgehensweise für die Auswahl der Gerätekomponenten und für die Durchführung von Prüfungen mit der Lockin-Thermografie. Daraus soll ein Standard abgeleitet werden, der die Prüfung
unterschiedlicher Materialsysteme auf Fehlstellen mittels Lockin-Thermografie unter Berücksichtigung verschiedener Anregungsquellen ermöglicht. In diesem Beitrag wird die Entwicklung der Probekörper vorgestellt, die in diesem Projekt untersucht und später als Referenzprobekörper verwendet werden können.
Die Synthetic Aperture Focusing Technique (SAFT) ist ein Verfahren zur Verarbeitung von HF-Bildern, die an unterschiedlichen Prüfkopfpositionen aufgenommen wurden. Es wird in der zerstörungsfreien Werkstoffprüfung genutzt, um eine Abbildung von Materialfehlern innerhalb des Gebietes zu erstellen, auf das die Rekonstruktion angewandt wird. Die nach Abschluss der SAFT-Rekonstruktion zusammengestellten Informationen über Reflektoren liegen zunächst nach wie vor in Form von HF-Daten vor. Die Interpretierbarkeit der SAFT-Bilder ist im Allgemeinen davon abhängig, wie diese Daten vor der endgültigen Darstellung aufbereitet werden. Die Bildung der Amplitudeneinhüllenden aus dem zugehörigen analytischen Signal stellt eine Möglichkeit einer solchen Aufbereitung nach Anwendung des SAFT-Algorithmus dar. Sie ist jedoch nur im eindimensionalen Fall eindeutig definiert. In diesem Beitrag wird das Konzept der analytischen Signale mit single-orthant-Spektren aufgegriffen, um eine Detektion der Einhüllenden an mehrdimensionalen HF-Daten durchzuführen. Dabei wird über die Betragsquadrate aller möglichen nach dieser Definition zu bildenden analytischen Signale gemittelt. Es wird gezeigt, dass die Anwendung des beschriebenen Verfahrens einem Separationsansatz entspricht. Außerdem wird eine Möglichkeit aufgezeigt die Gültigkeit dieses Ansatzes anhand der totalen und partiellen Hilberttransformationen des Signals im konkreten Fall zu überprüfen. Die Ergebnisse dieser Methode zur Verbesserung von SAFT Bildern werden unter Verwendung synthetischer und experimenteller Daten an rekonstruierten Abbildungen verschiedener Reflektorarten beispielhaft dargestellt.
Separation of CO2. Microporous polyurethane networks were prepared based on a renewable resource. Betulin, extracted from birch bark, is used as a structure-directing diol monomer in A3-B2 monomers. The resulting microporous networks show very promising CO2/N2 selectivities. The state of adsorbed CO2 is analyzed by in situ NMR spectroscopy, and pure physisorption is proven. The preparation of monolithic materials is demonstrated as well.
In welding experiments conducted on heavy wall pipes, the penetration mode (full or partial penetration) occurred to be a significant factor influencing appearance of solidification cracks. To explain the observed phenomena and support further optimization of manufacturing processes, a computational model was developed, which used a sophisticated strategy to model the material. High stresses emerged in the models in regions which showed cracking during experiments. In partial penetration welding, they were caused by the prevention of weld shrinkage due to the cold and strong material below the joint. Another identified factor having an influence on high stress localization is bulging of the weld.
PLR Prüftechnik Linke & Rühe Magdeburg und die BAM Bundesanstalt für Materialforschung und -prüfung Berlin haben in Zusammenarbeit mit anderen Partnern im Laufe der letzten Jahre verschiedene Wirbelstromsysteme zur Prüfung verlegter Schienen auf rissartige Fehler des Typs Head Checks entwickelt. Die Entwicklung dieser Systeme erfolgte mit dem Ziel, ein Hilfsmittel für die Planung von Schieneninstandhaltungsmaßnahmen zu schaffen. Die Systeme haben sich im praktischen Prüfeinsatz bewährt. Hierzu wurde regelmäßig auf den vorhergehenden Tagungen berichtet. Bei der Schieneninstandhaltung kommen unterschiedliche Typen von Schienenbearbeitungsmaschinen zum Einsatz, z. B. Schienenfräs- und Schleifzüge. Seit einiger Zeit wird von Seiten der Schienennetzbetreiber vermehrt ein Qualitätsnachweis nach erfolgter Schienenbearbeitung gefordert. Hierzu wurde ein Wirbelstromprüfsystem entwickelt, dass speziell an die Erfordernisse der Qualitätsüberwachung in Schienenbearbeitungsmaschinen angepasst ist. Das Prüfsystem wird vorgestellt und über erste Erfahrungen aus dem praktischen Einsatz wird berichtet.
Häufig müssen rotierende metallische Bauteile im Betrieb auf das Entstehen rissartiger Fehler überwacht werden. Hierbei besteht im Allgemeinen die Anforderung, trotz extrem schwieriger Umweltbedingungen eine sichere Prüfaussage zu gewährleisten. Es wurden Untersuchungen durchgeführt, inwieweit passive induktive Sensoren in der Lage sind, diese Anforderungen zu erfüllen. Hierzu wurden verschiedene einfache Sensormodelle aufgebaut und an verschiedenen Vergleichsfehlern erprobt. Die Ergebnisse der Untersuchungen werden vorgestellt. Insbesondere die Möglichkeiten und Grenzen dieser einfachen Sensortypen werden herausgearbeitet.
Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Algal blooms are a frequent phenomenon in nearly all kinds of fresh water. Global warming and eutrophication by waste water, air pollution and fertilizers seem to lead to an increased frequency of occurrence. Many cyanobacteria produce hazardous and quite persistent toxins, which can contaminate the respective water bodies. This may limit the use of the raw water for many purposes. The purification of the contaminated water might be quite costly, which makes a continuous and large scale treatment economically unfeasible in many cases. Due to the obvious risks of algal toxins, an online or mobile detection method would be highly desirable. Several biosensor systems have been presented in the literature for this purpose. In this review, their mode of operation, performance and general suitability for the intended purpose will be described and critically discussed. Finally, an outlook on current developments and future prospects will be given.
Thermografische ZfP-Verfahren erlauben die Erkennung einer Vielzahl von Defekten in unterschiedlichsten Werkstoffen. Neue Ansätze unter Verwendung von Lasern ermöglichen darüber hinaus die Prüfung auf Oberflächenrisse. Wir stellen die neuesten Entwicklungen dieser vielversprechenden Technik vor und zeigen warum deren Einsatz potentiell die Standardprüfverfahren Magnetpulver- bzw. Eindringprüfung für eine Reihe von Prüfproblemen beerben könnte. Hierzu stellen wir die Prüfergebnisse zu unterschiedlichen metallischen Werkstoffen, Rissgrößen und -typen in Abhängigkeit der Prüfparameter vor. Die aktuelle Grenze der Nachweisempfindlichkeit für die mittels klassischer Thermografie schwer prüfbaren hochreflektierenden Metalloberflächen liegt mit Rissbreiten und -tiefen von weni-gen Mikrometern im Bereich der fluoreszierenden Magnetpulver- und Eindringprüfung. Dabei sind weder Verbrauchsmittel noch eine Oberflächenpräparation notwendig und eine Prüfung kann berührungslos und automatisiert über Entfernungen im Meter-Bereich erfolgen.
Für die optische Erwärmung von Prüfteiloberflächen sind Blitz- und Halogenlampen Stand der Technik. Der Vorteil dieser Wärmequellen liegt in ihren relativ geringen Anschaffungskosten bei gleichzeitig hohen Leistungsdichten am Prüfobjekt. Nachteilig ist bei den Halogenlampen die Limitierung der möglichen Modulationsffequenz auf ca. 1 Hz für die Anwendung dieser Quelle in der Lockin-Thermografie. Blitzlampen bieten für gewöhnlich nur eine feste Blitzdauer bei einer geringen Taktrate. Beide Anregungsquellen müssen in Reflexionsanordnung mit Filtern betrieben werden um die entstehende thermische Eigenstrahlung als Störquelle zu eliminieren. Wir stellen Untersuchungen an Hochleistungs-LEDs für den Einsatz in der aktiven Thermografie vor. Diese Lichtquellen werden durch die rasante Entwicklung der möglichen Leistungsdichten nun auch für die thermografische ZfP interessant. Sie zeigen ähnlich dem Laser eine schmale und auf den Werkstoff abstimmbare spektrale Verteilung der Strahlungsleistung bei moderaten Kosten. Die zugrunde liegende Elektrolumineszenz generiert kaum Wärmestrahlung und ermöglicht dadurch die Prüfung während des Erwärmungsvorganges ohne größeren Aufwand. Modulationsfrequenzen über 100 Hz mit thermischen Eindringtiefen < 1 mm sind möglich. Dadurch qualifizieren sich die LEDs zur Anwendung in der Lockin-Thermografie von Metallen und zur oberflächennahen Prüfung von Schichtsystemen. Durch die fast verzögerungsffeie Reaktion der LED auf das steuernde Signal sind nahezu beliebige zeitliche Anregungsformen möglich. Mit solch flexiblen Anregungsformen ließen sich bereits bei den photothermischen Verfahren erfolgreich höhere Tiefenreichweiten und -auflösungen gegenüber den klassischen Methoden der monofrequenten Lockin - und energiereichen Kurzimpuls-Anregung erzielen. Untersuchungen dieser Möglichkeiten im praktischen Einsatz der HochleistungsLEDs werden vorgestellt und mit herkömmlichen Lichtquellen verglichen.
This survey will discuss current and emerging isothermal and rapid polymerase chain reaction (PCR) based nucleic acid amplification methods for patient near diagnostics. To assess the clinical need of rapid diagnostics for infectious diseases based on nucleic acid tests (NATs) we performed and analysed a questionnaire among laboratories participating in corresponding INSTAND ring trials for external quality assurance. The questions concerning new amplification technologies like isothermal nucleic acid amplification, potentially suited to significantly decrease turnaround times, were complemented by questions to evaluate the present status of NATs. Besides end-users, companies were also addressed by sending out a manufacturer specific questionnaire. Analysis of the answers from 48 laboratories in 14 European countries revealed that a much shorter turnaround time is requested for selected pathogens compared to about 2 h or longer when applying temperature cycling amplification, i.e. PCR. In this context, most frequently mentioned were MRSA, norovirus, influenza A and B viruses, cytomegalovirus (CMV) as well as hepatitis B virus (HBV) and hepatitis C virus (HCV). At present, 8% of the laboratories having participated in this survey apply isothermal amplification of nucleic acid to identify infectious pathogens.
Über die Entwicklung von Anwendungsregeln für reaktive Brandschutzsysteme auf Stahlzuggliedern
(2014)
Der vorliegende Beitrag stellt den Entwicklungsstand von Anwendungsregeln für reaktive Brandschutzsysteme auf Stahlzuggliedern zusammenfassend dar. Dabei wird insbesondere auf die jüngsten Veränderungen in den normativen Grundlagen und bauaufsichtlichen Regelungen eingegangen und im Hinblick auf Sicherheitsaspekte bewertet.
Die Verringerung der Teilsicherheit für den Bauteilwiderstand nicht stabilitätsgefährdeter Bauteile im Regelwerk für die Kaltbemessung von Stahltragwerken ist hier als besonders kritisch anzusehen, da hierdurch ein systematisches Sicherheitsdefizit für den Brandfall verursacht wird.
Weiterhin werden neuste Forschungsergebnisse bei der Entwicklung von Bewertungsregeln von reaktiven Brandschutzsystemen auf Vollkreisprofilen unter Zugbeanspruchung vorgestellt und diskutiert. Die Untersuchungen behandeln die Fragestellung, inwieweit Prüfungen mit Zugbeanspruchungen an Kreisvollprofilen erforderlich sein werden.
Sollten CT Aufnahmen quantitativ und automatisch ausgewertet werden, ist die Qualität der Tomogramme ein wesentlicher Punkt. Außerdem steht bei Serienmessungen nur eine begrenzte Meßzeit für jede Probe. Es werden die verschiedenen Mikrofokusröhren in Bezug auf die Parameter Orts- und Dichteauflösung, sowie Meßzeit verglichen, CT Beispiele dazu gezeigt.
The synthesis of the polymorphic cocrystal caffeine:anthranilic acid was investigated to obtain a better understanding of the processes leading to the formation of different polymorphic forms. In the case of these cocrystal polymorphs synthesized by liquid-assisted grinding a distinct influence of the dipole moment of the solvent was found. A pre-coordination between the solvent molecules and the caffeine:anthranilic acid cocrystal could be identified in the formation of form II. In the case of form II the solvent can be regarded as a catalyst. The formation pathway of each polymorph was evaluated using synchrotron X-ray diffraction.
Fourier-Spektroskopische Untersuchungen von hochmolekularem Polyethylen (HMW-PE) und ultrahochmolekularem Polyethylen (UHMW-PE) im Mittleren - und Fernen Infrarotbereich können Veränderungen der molekularen Strukturen nachweisen, die durch Co60 γ-Strahlung und Rekristallisationsprozesse initiiert werden. UHMW-PE und HMW-PE sind im gewählten IR-Bereich unterscheidbar. Die integrale Absorption der B1u – Gitterschwingungen im Fernen Infrarotbereich (THz-Bereich) ermöglichen die quantitative Beschreibung des Kristallinitätsgrades und dessen Abbau. Die Bildung ungesättigter Vinylengruppen und der Abbau ungesättigter Methylengruppen können im Mittleren Infrarotbereich nachgewiesen werden.
Geführte Ultraschallwellen bieten eine Vielzahl von Einsatzmöglichkeiten in der Zerstörungsfreien Prüfung, der Zustandsüberwachung sowie der Materialcharakterisierung. Insbesondere für Rohrleitungen und ausgedehnte Plattenstrukturen ist eine Vielzahl von auf geführten Wellen basierenden Verfahren in der Entwicklung und teilweise bereits im Einsatz. Aufgrund des komplexen Ausbreitungsverhaltens geführter Wellen werden numerische Verfahren (etwa die Finite Elemente Methode (FEM) oder die Randelementemethode (BEM)) zur Simulation der Wellenausbreitung sowie der Wechselwirkung mit Defekten in Wellenleitern angewendet. Diese Methoden sind für große Strukturen extrem rechenintensiv und umständlich in der Anwendung. Ein ungleich effizienteres Verfahren wurde kürzlich von den Autoren auf Grundlage der Scaled Boundary Finite Element Method entwickelt. Ein semi-analytischer Ansatz erlaubt die Modellierung beliebig ausgedehnter Strukturen bei extrem kurzen Rechenzeiten. Die Wechselwirkung geführter Wellen mit Rissen kann auf besonders elegante und exakte Weise beschrieben werden. Mit dieser Methode können die komplexen Vorgänge in Wellenleitern innerhalb weniger Sekunden modelliert werden.