Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2020 (60) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (59)
- Sonstiges (1)
Schlagworte
- Fluorescence (10)
- Lifetime (6)
- Quantum yield (6)
- Magnetic resonance imaging (5)
- Photoluminescence (5)
- Sensor (5)
- Dye (4)
- Multiplexing (4)
- Photophysics (4)
- Traceability (4)
- Electrochemistry (3)
- Gadolinium (3)
- ICP-MS (3)
- Lanthanide (3)
- NIR (3)
- Nano (3)
- Particle (3)
- Process Industry (3)
- Quality assurance (3)
- Raman spectroscopy (3)
- Absolute isotope ratio (2)
- Atherosclerosis (2)
- Bead (2)
- Biosensing (2)
- Calibration (2)
- Cancer (2)
- Crystal (2)
- Diagnostics (2)
- Digitalisation (2)
- ELISA (2)
- Flow cytometry (2)
- Gadofosveset (2)
- Hybridoma (2)
- Imaging (2)
- Immunoassay (2)
- Industry 4.0 (2)
- LA-ICP-MS (2)
- Lab-on-a-chip (2)
- Laser ablation (2)
- Mass spectrometry (2)
- Method (2)
- Microscopy (2)
- Nanoparticle (2)
- Nanoparticles (2)
- Quality Control (2)
- Quantification (2)
- Reproducibility (2)
- Surface chemistry (2)
- Synthesis (2)
- Triple isotope fractionation (2)
- Upconversion (2)
- XPS (2)
- 2D chromatography (1)
- AIE (1)
- AIS (1)
- Aautomatisation (1)
- Absorption (1)
- Abwasser (1)
- Acrylamide (1)
- Adsorbable organically bound fluorine (AOF) (1)
- Aggregation (1)
- Aggregation-induced emission (1)
- Aging (1)
- Airport (1)
- Amplification (1)
- Analytical Chemistry (1)
- Angiography (1)
- Anhydrite (1)
- Anthropocene (1)
- Antibody (1)
- Antibody-gated indicator delivery (1)
- Antikörper (1)
- Aqueous quantum dot (1)
- Artificial neural networks (1)
- Artificial weathering (1)
- Assay (1)
- Automation (1)
- Aviation (1)
- Aza-BODIPY (1)
- BPA removal (1)
- Back-side integration (1)
- Barcoding (1)
- Bassanite (1)
- Bead-based assay (1)
- Benzothiadiazole (1)
- Biosensors (1)
- Bombs (1)
- Boron compound (1)
- Brain (1)
- CEA (1)
- CONSENS (1)
- CUINS2 nanocrystals (1)
- Cadmium (1)
- Calcite (1)
- Cardiovascular (1)
- Certified reference material (1)
- Coating (1)
- Cocoa (1)
- Colloidal semiconductor nanocrystals (1)
- Combustion ion chromatography (CIC) (1)
- Comparability (1)
- Continuous Sensor (1)
- Contrast agent (1)
- Coordination polymer (1)
- Corophium volutator (1)
- Cr(III) (1)
- Cyber-physical system (1)
- DNA origami (1)
- DNA radiation damage (1)
- DNA strand breaks (1)
- Damage-associated molecular patterns (DAMPs) (1)
- Degradation (1)
- Delta scale (1)
- Design of experiment (1)
- Digestion (1)
- Digital Twins (1)
- Digital transformation (1)
- Digital twins (1)
- Dye monomers (1)
- ESMA (1)
- Elastin-specific contrast agent ESMA (1)
- Elastin-specific molecular agent (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Enhancement (1)
- Environmental pollutants (1)
- Environmental simulations (1)
- Environmental speciation (1)
- Etofenprox (1)
- Explosiven (1)
- Explosives detection (1)
- Extracellular matrix (1)
- Extractable organically bound fluorine (EOF) (1)
- FRET (1)
- Ferumoxytol (1)
- Flexible crystals (1)
- Fluorescence life time (1)
- Fluorescence standard (1)
- Fluoride (1)
- Fluorides (1)
- Food analysis (1)
- Forsterite (1)
- Fourier transform spectroscopy (1)
- Gadolinium-based contrast agent (1)
- Gadovist (1)
- Galvanic anodes (1)
- Gated materials (1)
- Gesteuerten Nanopartikeln (1)
- Grafting (1)
- Green light excitation (1)
- Gypsum (1)
- HF free Digestion (1)
- HTS (1)
- Hemihydrate (1)
- Hepatocellular carcinoma (1)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (1)
- High-Speed (1)
- High-throughput (1)
- Human leukocyte antigen (HLA) (1)
- Hydrodynamic chromatography (HDC) (1)
- ICP-OES (1)
- Immunoassays (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inductively coupled plasma mass spectroscopy (1)
- Inductively‑coupled mass spectrometry (1)
- Inhibition (1)
- Interferometric spectroscopy (1)
- Iposomes (1)
- Iron oxide (1)
- Iterative real-time optimization (1)
- LC-MS (1)
- Label (1)
- Laboratory 4.0 (1)
- Lanthanides (1)
- Laser ablation-inductively coupled plasma-mass spectrometry (1)
- Lateral flow assay (1)
- Leaching (1)
- LiYF4 (1)
- Lifetime-encoded beads (1)
- Light harvesting (1)
- Low-energy electrons (1)
- Lymnaea stagnalis (1)
- MLCT (1)
- MR Angiography (1)
- MR imaging (1)
- MYCN (1)
- Mass-Spectrometry (1)
- Mechanical properties (1)
- Mesoporous particles (1)
- Metal toxicity (1)
- Metal uptake (1)
- Methanol oxidation (1)
- Microarray (1)
- Microplastic-induced effects (1)
- Microplatic (1)
- Mineral identification (1)
- Mineral paragenesis (1)
- Miniaturization (1)
- Mixture toxicity (1)
- Modelling (1)
- Modifier adaptation (1)
- Molecular-MRI (1)
- Molecularly imprinted polymers (1)
- Monoclonal Antibody (1)
- Multiple-injection sample-standard bracketing (1)
- Multiplex (1)
- NIR-I (1)
- NSE (1)
- Nano-carrier (1)
- Nanomaterial (1)
- Nanoparticle characterization (1)
- On-line CE/MC-ICP-MS (1)
- Online NMR Spectroscopy (1)
- Online NMR spectroscopy (1)
- Optical detection (1)
- Optical imaging (1)
- Organic-inorganic hybrid composites (1)
- PIC technology (1)
- PSA (1)
- Particle architecture (1)
- Pattern recognition receptor (1)
- Per- and polyfluorinated alkyl substances (PFASs) (1)
- Permethrin (1)
- Phenothrin (1)
- Phospholipids (1)
- Phosphorescence (1)
- Photoinduced electron transfer (1)
- Photonic biosensor (1)
- Photosensitization (1)
- Physical twin (1)
- Physico-chemical characterisation of minerals (1)
- Plant-model mismatch (1)
- Plastic deformation (1)
- Polarity (1)
- Polymer-based products (1)
- Process Analytical Technology (1)
- Process Control (1)
- Process analytical technology (1)
- Process industry (1)
- Process intelligence (1)
- Protein (1)
- Protein nitration (1)
- Protein oligomerization (1)
- Pt(111) (1)
- Quantum dot (1)
- Quantum dots (1)
- Quartz (1)
- Raman microspectroscopy (1)
- Reactor control (1)
- Real-time process monitoring (1)
- Recombinant Antibody (1)
- Redox (1)
- Redox switch (1)
- Reference (1)
- Reference Materials (1)
- Renal disease (1)
- Renewable copolymers (1)
- Resonance wavelength shift (1)
- Ring resonator (1)
- River water sulfate (1)
- Ruthenium(II) complexes (1)
- SAXS (1)
- SBA-15 (1)
- SBA-16 (1)
- SEC (1)
- SWIR (1)
- Scale anchor (1)
- Screening (1)
- Seawater (1)
- Sediment (1)
- Semiconductor (1)
- Semiconductor quantum dot (1)
- Sensitization (1)
- Sequence dependence (1)
- Shell (1)
- Single particle (1)
- Single particle ICP-MS (1)
- Smart sensors (1)
- Smart test laboratories (1)
- Smarter Sensor (1)
- Soil contact (1)
- Sol-gel process (1)
- Solar cells (1)
- Solid state emission (1)
- Spatial heterodyne spectrometer (1)
- Specific probe (1)
- Spectrometer (1)
- Stability (1)
- Stranski–Krastanow growth (1)
- Sulfur isotopes (1)
- Supported catalyst (1)
- Surface waters (1)
- Sustainable Production (1)
- Switch (1)
- TEM (1)
- Terrorism (1)
- Theranostic (1)
- Thermal Process Engineering (1)
- Thickness (1)
- Tomography (1)
- Triplet-triplet annihilation (1)
- Tutzing Symposion (1)
- Type-I pyrethroids (1)
- Ultrasensitive (1)
- Umweltschadstoffe (1)
- Uncertainty (1)
- Upconversion nanoparticle (1)
- Validation (1)
- Vanadium oxide catalysts (1)
- Visualization (1)
- Yb(III) complex (1)
- calibration (1)
- dye (1)
- magnetic nanocatalysts (1)
- photoluminescence (1)
- research landscape (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (60) (entfernen)
Paper des Monats
- ja (1)
Metal-containing nanoparticles (NP) can be characterized with inductively coupled plasma mass spectrometers (ICP-MS) in terms of their size and number concentration by using the single-particle mode of the instrument (spICP-MS). The accuracy of measurement depends on the setup, operational conditions of the instrument and specific parameters that are set by the user. The transport efficiency of the ICP-MS is crucial for the quantification of the NP and usually requires a reference material with homogenous size distribution and a known particle number concentration.
Currently, NP reference materials are available for only a few metals and in limited sizes. If particles are characterized without a reference standard, the results of both size and particle number may be biased. Therefore, a dual-inlet Setup for characterizing nanoparticles with spICP-MS was developed to overcome this problem. This setup is based on a conventional introduction system consisting of a pneumatic nebulizer (PN) for nanoparticle solutions and a microdroplet Generator (μDG) for ionic calibration solutions. A new and flexible interface was developed to facilitate the coupling of μDG, PN and the ICP-MS system. The interface consists of available laboratory components and allows for the calibration, nanoparticle (NP) characterization and cleaning of the arrangement, while the ICP-MS instrument is still running.
Three independent analysis modes are available for determining particle size and number concentration. Each mode is based on a different calibration principle.
While mode I (counting) and mode III (μDG) are known from the literature, mode II (sensitivity), is used to determine the transport efficiency by inorganic ionic Standard solutions only. It is independent of NP reference materials. The μDG based inlet system described here guarantees superior analyte sensitivities and, therefore, lower detection limits (LOD). The size dependent LODs achieved are less than 15 nm for all NP (Au, Ag, CeO2) investigated.
Abdominal aortic aneurysm (AAA) is a life-threatening vascular disease with an up to 80% mortality in case of rupture. Current biomarkers fail to account for size-independent risk of rupture. By combining the information of different molecular probes, multi-target molecular MRI holds the potential to enable individual characterization of AAA. In this experimental study, we aimed to examine the feasibility of simultaneous imaging of extracellular collagen and inflammation for size-independent prediction of risk of rupture in murine AAA. The study design consisted of: (1) A outcome-based longitudinal study with imaging performed once after one week with follow-up and death as the end-point for assessment of rupture risk. (2) A week-by-week study for the characterization of AAA development with imaging after 1, 2, 3 and 4 weeks. For both studies, the animals were administered a type 1 collagen-targeted gadolinium-based probe (surrogate marker for extracellular matrix (ECM) remodeling) and an iron oxide-based probe (surrogate marker for inflammatory activity), in one imaging session. In vivo measurements of collagen and iron oxide probes showed a significant correlation with ex vivo histology (p < 0.001) and also corresponded well to inductively-coupled plasma-mass spectrometry and laser-ablation inductively-coupled plasma mass spectrometry. Combined evaluation of collagen-related ECM remodeling and inflammatory activity was the most accurate predictor for AAA rupture (sensitivity 80%, specificity 100%, area under the curve 0.85), being superior to information from the individual probes alone. Our study supports the feasibility of a simultaneous assessment of collagen-related extracellular matrix remodeling and inflammatory activity in a murine model of AAA.
Abdominal aortic aneurysm (AAA) remains a fatal disease. Its development encompasses a complex interplay between hemodynamic stimuli on and changes in the arterial wall. Currently available biomarkers fail to predict the risk of AAA rupture independent of aneurysm size. Therefore, novel biomarkers for AAA characterization are needed. In this study, we used a mouse model of AAA to investigate the potential of magnetic resonance imaging (MRI) with an albumin-binding probe to assess changes in vascular permeability at different stages of aneurysm growth. Two imaging studies were performed: a longitudinal study with follow-up and death as endpoint to predict rupture risk and a week-by-week study to characterize AAA development. AAAs, which eventually ruptured, demonstrated a significantly higher in vivo MR signal enhancement from the albumin-binding probe (p = 0.047) and a smaller non-enhancing thrombus area compared to intact AAAs (p = 0.001). The ratio of albumin-binding-probe enhancement of the aneurysm wall to size of non-enhancing-thrombus-area predicted AAA rupture with high sensitivity/specificity (100%/86%). More advanced aneurysms with higher vascular permeability demonstrated an increased uptake of the albumin-binding-probe. These results indicate that MRI with an albumin-binding probe may enable noninvasive assessment of vascular permeability in murine AAAs and prediction of rupture risk.
The goal of this work is to identify the optimal operating input for a lithiation reaction that is performed in a highly innovative pilot scale continuous flow chemical plant in an industrial environment, taking into account the process and safety constraints. The main challenge is to identify the optimum operation in the absence of information about the reaction mechanism and the reaction kinetics. We employ an iterative real-time optimization scheme called modifier adaptation with quadratic approximation (MAWQA) to identify the plant optimum in the presence of plant-model mismatch and measurement noise. A novel NMR PAT-sensor is used to measure the concentration of the reactants and of the product at the reactor outlet. The experiment results demonstrate the capabilities of the iterative optimization using the MAWQA algorithm in driving a complex real plant to an economically optimal operating point in the presence of plant-model mismatch and of process and measurement uncertainties.
Redox switches are applied in various fields of research, including molecular lifts, electronic devices and sensors. Switching the absorbance between UV and Vis/NIR by redox processes is of interest for applications in light harvesting or biomedicine.
Here, we present a series of push-pull benzothiadiazole derivatives with high fluorescence quantum yields in solution and in the crystalline solid state. Spectroelectrochemical analysis reveals the switching of UV-absorption in the neutral state to Vis/NIR absorption in the reduced state. We identify the partial irreversibility of the switching process, which appears to be reversible on the cyclic voltammetry timescale.
Background: Cathodic protection by sacrifcial anodes composed of aluminum-zinc-indium alloys is often applied to protect ofshore support structures of wind turbines from corrosion. Given the considerable growth of renewable energies and thus ofshore wind farms in Germany over the last decade, increasing levels of aluminum, Indium and zinc are released to the marine environment. Although these metals are ecotoxicologically well-studied, data regarding their impact on marine organisms, especially sediment-dwelling species, as well as possible ecotoxicological efects of galvanic anodes are scarce. To investigate possible ecotoxicological efects to the marine environment, the diatom Phaedactylum tricornutum, the bacterium Aliivibrio fscheri and the amphipod Corophium volutator were exposed to dissolved galvanic anodes and solutions of aluminum and zinc, respectively, in standardized laboratory tests using natural seawater. In addition to acute toxicological efects, the uptake of these elements by C. volutator was investigated.
Results: The investigated anode material caused no acute toxicity to the tested bacteria and only weak but signifcant efects on algal growth. In case of the amphipods, the single elements Al and Zn showed signifcant efects only at the highest tested concentrations. Moreover, an accumulation of Al and In was observed in the crustacea species.
Conclusions: Overall, the fndings of this study indicated no direct environmental impact on the tested marine organisms by the use of galvanic anodes for cathodic protection. However, the accumulation of metals in, e.g., crustaceans might enhance their trophic transfer within the marine food web.
Vor dem Hintergrund der einzigartigen Modularität, hohen Empfindlichkeit und Selektivität von Antikörper‐gesteuerten Indikatorfreisetzungssystemen (gAID‐Systemen) wurde hier ein Multiplex‐Assay für drei organische Explosivstoffmoleküle (TATP, TNT, PETN) entwickelt, der es erlaubt, die Analyten gleichzeitig in flüssiger Phase mit einem einzelnen Teststreifen und einem Fluoreszenzlesegerät bzw. Smartphone als Detektor in Konzentrationen bis in den unteren ppb‐Bereich in <5 min nachzuweisen. Alle drei Systeme, darunter die hier neu entwickelten Systeme für TNT und PETN, tolerieren zudem nicht nur gepufferte wässrige Modelllösungen, sondern auch komplexere Matrices. Neben einem konventionellen Teststreifen mit einem Kanal erlaubte uns die Anwendung von Wachsdrucktechnologie das Herstellen von mehrkanaligen Streifen mit vergleichbarer analytischer Leistungsfähigkeit, was das enorme Potenzial der modular aufgebauten, hybriden Biosensormaterialien im Hinblick auf eine für den Endanwender maßgeschneiderte Vor‐Ort‐Analytik unterstreicht.
Rapid testing methods for the use directly at apointof need are expected to unfold their true potential especiallywhen offering adequate capabilities for the simultaneousmeasurement of multiple analytes of interest. Considering theunique modularity,high sensitivity,and selectivity of antibody-gated indicator delivery (gAID) systems,amultiplexed assayfor three small-molecule explosives (TATP, TNT,PETN) wasthus developed, allowing to detect the analytes simultaneouslywith asingle test strip at lower ppb concentrations in the liquidphase in < 5min using afluorescence reader or asmartphonefor readout. While the TNT and PETN systems were newlydeveloped here,all the three systems also tolerated harshermatrices than buffered aqueous model solutions.Besidesasingle-track strip,the outstanding modularity of the hybridbiosensor materials in combination with strip-patterningtechnologies allowed us to obtain amultichannel strip inastraightforwardmanner,offering comparable analyticalperformance while allowing to be tailored even more to theusersneed.
Pharmacologically active compounds are often detected in wastewater and surface waters. The nonsteroidal anti-inflammatory drug diclofenac (DCF) was included in the European watch list of substances that requires its environmental monitoring in the member states. DCF may harmfully influence the ecosystem already at concentrations ≤ 1 μg L−1. The fast and easy quantification of DCF is becoming a subject of global importance. Fluorescence polarization immunoassay (FPIA) is a homogeneous mix-and-read method which does not require the immobilization of reagents. FPIA can be performed in one phase within 20–30 min, making it possible to analyse wastewater without any complicated pre-treatment. In this study, new tracermolecules with different structures, linking fluorophores to derivatives of the analyte, were synthesized, three homologous tracers based on DCF, two including a C6 spacer, and one heterologous tracer derived from 5-hydroxy-DCF. The tracer molecules were thoroughly assessed for performance. Regarding sensitivity of the FPIA, the lowest limit of detection reached was 2.0 μg L−1 with a working range up to 870 μg L−1. The method was validated for real wastewater samples against LC-MS/MS as reference method with good agreement of both methods.
facile hydrothermal method to synthesize water-soluble copper indium sulfide (CIS) nanocrystals (NCs) at 150 degrees C is presented. The obtained samples exhibited three distinct photoluminescence peaks in the red, green and blue spectral regions, corresponding to three size fractions, which could be separated by means of size-selective precipitation. While the red and green emitting fractions consist of 4.5 and 2.5 nm CIS NCs, the blue fraction was identified as in situ formed carbon nanodots showing excitation wavelength dependent emission. When used as light absorbers in quantum dot sensitized solar cells, the individual green and red fractions yielded power conversion efficiencies of 2.9% and 2.6%, respectively. With the unfractionated samples, the efficiency values approaching 5% were obtained. This improvement was mainly due to a significantly enhanced photocurrent arising from complementary panchromatic absorption.
Controlling thickness and tightness of surface passivation shells is crucial for many applications of core–shell nanoparticles (NP). Usually, to determine shell thickness, core and core/shell particle are measured individually requiring the availability of both nanoobjects. This is often not fulfilled for functional nanomaterials such as many photoluminescent semiconductor quantum dots (QD) used for bioimaging, solid state lighting, and display technologies as the core does not show the applicationrelevant functionality like a high photoluminescence (PL) quantum yield, calling for a whole nanoobject approach. By combining high-resolution transmission electron microscopy (HR-TEM) and X-ray photoelectron spectroscopy (XPS), a novel whole nanoobject approach is developed representatively for an ultrabright oleic acid-stabilized, thick shell CdSe/CdS QD with a PL quantum yield close to unity. The size of this spectroscopically assessed QD, is in the range of the information depth of usual laboratory XPS. Information on particle size and monodispersity were validated with dynamic light scattering (DLS) and small angle X-ray scattering (SAXS) and compared to data derived from optical measurements. In addition to demonstrating the potential of this novel whole nanoobject approach for determining architectures of small nanoparticles, the presented results also highlight challenges faced by different sizing and structural analysis methods and method-inherent uncertainties.
The growth of ultrathin layers of VOx (<12 monolayers) on Pt(111) and the activity of these layers in catalytic methanol oxidation at 10−4 mbar have been studied with low-energy electron difraction, Auger electron spectroscopy, rate measurements, and with photoemission electron microscopy. Reactive deposition of V in O2 at 670 K obeys a Stranski–Krastanov growth mode with a (√3 × √3)R30° structure representing the limiting case for epitaxial growth of 3D-VOx. The activity of VOx/Pt(111) in catalytic methanol oxidation is very low and no redistribution dynamics is observed lifting the initial spatial homogeneity of the VOx layer. Under reaction conditions, part of the surface vanadium difuses into the Pt subsurface region.
Exposure to O2 causes part of the V to difuse back to the surface, but only up to one monolayer of VOx can be stabilized in this way at 10−4 mbar.
To investigate the imaging performance of an elastin-specific molecular magnetic resonance imaging (MRI) probe with respect to the extracellular matrix (ECM) in an experimental hepatic cancer model. Twelve rabbits with hepatic VX2 tumors were examined using 3 T MRI 14, 21, and 28 days after tumor implantation for two subsequent days (gadobutrol, day 1; elastin-specific probe, day 2). The relative enhancement (RE) of segmented tumor regions (central and margin) and the peritumoral matrix was calculated using pre-contrast and delayed-phase T1w sequences. MRI measurements were correlated to histopathology and element-specific and spatially resolved mass spectrometry (MS). Mixed-model analysis was performed to assess the performance of the elastin-specific probe. In comparison to gadobutrol, the elastin probe showed significantly stronger RE, which was pronounced in the tumor margin (day 14–28: P ≤ 0.007). In addition, the elastin probe was superior in discriminating between tumor regions (χ2(4) = 65.87; P < 0.001). MRI-based measurements of the elastin probe significantly correlated with the ex vivo elastinstain (R = .84; P <0 .001) and absolute gadolinium concentrations (ICP-MS: R = .73, P <0 .01). LA-ICP-MS imaging confirmed the colocalization of the elastin-specific probe with elastic fibers. Elastin-specific molecular MRI is superior to non-specific gadolinium-based contrast agents in imaging the ECM of hepatic tumors and the peritumoral tissue.
Between Aromatic and Quinoid Structure: A Symmetrical UV to Vis/NIR Benzothiadiazole Redox Switch
(2020)
Reversibly switching the light absorption of organic molecules by redox processes is of interest for applications in sensors, light harvesting, smart materials, and medical diagnostics. This work presents a symmetrical benzothiadiazole (BTD) derivative with a high fluorescence quantum yield in solution and in the crystalline state and shows by spectroelectrochemical analysis that reversible switching of UV absorption in the neutral state, to broadband Vis/NIR absorption in the 1st oxidized state, to sharp band Vis absorption in the 2nd oxidized state, is possible.
For the one-electron oxidized species, formation of a delocalized radical is confirmed by electron paramagnetic resonance spectroelectrochemistry. Furthermore, our results reveal an increasing quinoidal distortion upon the 1st and 2nd oxidation, which can be used as the leitmotif for the development of BTD based redox switches.
Background:
Molecular-MRI is a promising imaging modality for the assessment of abdominal aortic aneurysms (AAAs). Interleukin-1β (IL-1β) represents a new therapeutic tool for AAA-treatment, since pro-inflammatory cytokines are key-mediators of inflammation. This study investigates the potential of molecular-MRI to evaluate therapeutic effects of an anti-IL-1β-therapy on AAA-formation in a mouse-model.
Methods:
Osmotic-minipumps were implanted in apolipoprotein-deficient-mice (N = 27). One group (Ang-II+01BSUR group, n = 9) was infused with angiotensin-II (Ang-II) for 4 weeks and received an anti-murine IL-1β-antibody (01BSUR) 3 times. One group (Ang-II-group, n = 9) was infused with Ang-II for 4 weeks but received no treatment. Control-group (n = 9) was infused with saline and received no treatment. MR-imaging was performed using an elastin-specific gadolinium-based-probe (0.2 mmol/kg).
Results:
Mice of the Ang-II+01BSUR-group showed a lower aortic-diameter compared to mice of the Ang-II-group and control mice (p < 0.05). Using the elastin-specific-probe, a significant decrease in elastin-destruction was observed in mice of the Ang-II+01BSUR-group. In vivo MR-measurements correlated well with histopathology (y = 0.34x-13.81, R2 = 0.84, p < 0.05), ICP-MS (y = 0.02x+2.39; R2 = 0.81, p < 0.05) and LA-ICP-MS. Immunofluorescence and western-blotting confirmed a reduced IL-1β-expression.
Conclusions:
Molecular-MRI enables the early visualization and quantification of the anti-inflammatory-effects of an IL-1β-inhibitor in a mouse-model of AAAs. Responders and non-responders could be identified early after the initiation of the therapy using molecular-MRI.
CMOS-Compatible Silicon Photonic Sensor for Refractive Index Sensing Using Local Back-Side Release
(2020)
Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line. The sensor is based on a micro-ring resonator and is fabricated on wafer-level using a CMOS technology. We revealed a ring resonator sensitivity for homogeneous sensing of 106 nm/RIU.
Environmental pollutants like fine particulate matter can cause adverse health effects through oxidative stress and inflammation. Reactive oxygen and nitrogen species (ROS/RNS) such as peroxynitrite can chemically modify proteins, but the effects of such modifications on the immune system and human health are not well understood. In the course of inflammatory processes, the Toll-like receptor 4 (TLR4) can sense damage-associated molecular patterns (DAMPs). Here, we investigate how the TLR4 response and pro-inflammatory potential of the proteinous DAMPs α-Synuclein (α-Syn), heat shock protein 60 (HSP60), and high-mobility-group box 1 protein (HMGB1), which are relevant in neurodegenerative and cardiovascular diseases, changes upon chemical modification with peroxynitrite.
For the peroxynitrite-modified proteins, we found a strongly enhanced activation of TLR4 and the pro-inflammatory transcription factor NF-κB in stable reporter cell lines as well as increased mRNA expression and secretion of the pro-inflammatory cytokines TNF-α, IL-1β, and IL-8 in human monocytes (THP-1). This enhanced activation of innate immunity via TLR4 is mediated by covalent chemical modifications of the studied DAMPs.
Our results show that proteinous DAMPs modified by peroxynitrite more potently amplify inflammation via TLR4 activation than the native DAMPs, and provide first evidence that such modifications can directly enhance innate immune responses via a defined receptor. These findings suggest that environmental pollutants and related ROS/RNS may play a role in promoting acute and chronic inflammatory disorders by structurally modifying the body's own DAMPs. This may have important consequences for chronic neurodegenerative, cardiovascular or gastrointestinal diseases that are prevalent in modern societies, and calls for action, to improve air quality and climate in the Anthropocene.
Antibody-gated indicator delivery (gAID) systems based on mesoporous silica nano- and microparticle scaffolds are a promising class of materials for the sensitive chemical detection of small-molecule analytes in simple test formats such as lateral flow assays (LFAs) or microfluidic chips. Their architecture is reminiscent of drug delivery systems, only that reporter molecules instead of drugs are stored in the voids of a porous host particle. In addition, the pores are closed with macromolecular “caps” through a tailored “gatekeeping” recognition chemistry so that the caps are opened when an analyte has reacted with a “gatekeeper”. The subsequent uncapping leads to a release of a large number of indicator molecules, endowing the system with signal amplification features. Particular benefits of such systems are their modularity and adaptability. With the example of the immunochemical detection of type-I pyrethroids by fluorescent dye-releasing gAID systems, the influence of several tuning modes on the optimisation of such hybrid sensory materials is introduced here. In particular, different mesoporous silica supports (from nano- and microparticles to platelets and short fibres), different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in the absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material's pore opening, the better the closing/opening mechanism can be controlled. Because such materials are well-suited for LFAs, performance assessment included a test-strip format besides conventional assays in suspension. In combination with dyes as indicators and smartphones for read-out, simple analytical tests for use by untrained personnel directly at a point-of-need such as an aeroplane cabin can be devised, allowing for sensitivities down to the μg kg−1 range in <5 min with case-required selectivities.
The theory of a new calibration approach for obtaining absolute isotope ratios of multi-isotopic elements without the use of any standard has been developed. The calibration approach basically uses the difference in the instrumental isotope fractionation of two different types of mass spectrometers, leading to two different fractionation lines in a three-isotope diagram. When measuring the same sample with both mass spectrometers, the different fractionation lines have one point in common: this is the ‘true’ logarithmized isotope ratio pair of the sample. Thus, the intersection of both fractionation lines provides us with the absolute isotope ratios of the sample. This theory has been tested in practice by measuring Cd and of Pb isotope ratios in the certified reference materials BAM-I012 and NIST SRM981 by thermal ionization mass spectrometry and by inductively coupled plasma mass spectrometry while varying the ionization conditions for both mass spectrometers. With this experiment, the theory could be verified, and absolute isotope ratios were obtained, which were metrologically compatible with the certified isotope ratios. The so-obtained absolute isotope ratios are biased by − 0.5% in average, which should be improved with further developments of the method. This calibration approach is universal, as it can be applied to all elements with three or more isotopes and it is not limited to the type of mass spectrometers applied; it can be applied as well to secondary ion mass spectrometry or others. Additionally, this approach provides information on the fractionation process itself via the triple-isotope fractionation exponent θ.
To demonstrate the potential of time-resolved flow cytometry (FCM) for bioanalysis, clinical diagnostics, and optically encoded bead-based assays, we performed a proof-of-principle study to detect biomolecular interactions utilizing fluorescence lifetime (LT)-encoded micron-sized polymer beads bearing target-specific bioligands and a recently developed prototype lifetime flow cytometer (LT-FCM setup). This instrument is equipped with a single excitation light source and different fluorescence detectors, one operated in the photon-counting mode for time-resolved measurements of fluorescence decays and three detectors for conventional intensity measurements in different spectral windows. First, discrimination of bead-bound biomolecules was demonstrated in the time domain exemplarily for two targets, Streptavidin (SAv) and the tumor marker human chorionic gonadotropin (HCG). In a second step, the determination of biomolecule concentration levels was addressed representatively for the inflammation-related biomarker tumor necrosis factor (TNF-α) utilizing fluorescence intensity measurements in a second channel of the LT-FCM instrument. Our results underline the applicability of LT-FCM in the time domain for measurements of biomolecular interactions in suspension assays. In the future, the combination of spectral and LT encoding and multiplexing and the expansion of the time scale from the lower nanosecond range to the longer nanosecond and the microsecond region is expected to provide many distinguishable codes. This enables an increasing degree of multiplexing which could be attractive for high throughput screening applications.