Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (2089) (entfernen)
Sprache
- Englisch (2046)
- Deutsch (40)
- Mehrsprachig (2)
- Portugiesisch (1)
Schlagworte
- Additive manufacturing (64)
- Fluorescence (56)
- SAXS (46)
- Nanoparticles (45)
- Concrete (37)
- MALDI-TOF MS (37)
- Quantum yield (36)
- Corrosion (35)
- Mechanochemistry (29)
- Polylactide (29)
Organisationseinheit der BAM
- 6 Materialchemie (436)
- 1 Analytische Chemie; Referenzmaterialien (356)
- 8 Zerstörungsfreie Prüfung (315)
- 5 Werkstofftechnik (206)
- 9 Komponentensicherheit (202)
- 7 Bauwerkssicherheit (190)
- 4 Material und Umwelt (182)
- 6.3 Strukturanalytik (168)
- 8.5 Röntgenbildgebung (119)
- 6.1 Oberflächen- und Dünnschichtanalyse (97)
- 5.1 Mikrostruktur Design und Degradation (79)
- 9.3 Schweißtechnische Fertigungsverfahren (76)
- 1.2 Biophotonik (73)
- 6.6 Physik und chemische Analytik der Polymere (70)
- 8.0 Abteilungsleitung und andere (68)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (65)
- 9.4 Integrität von Schweißverbindungen (65)
- 6.2 Material- und Oberflächentechnologien (62)
- 1.1 Anorganische Spurenanalytik (61)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (61)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (57)
- 1.4 Prozessanalytik (55)
- 1.7 Organische Spuren- und Lebensmittelanalytik (55)
- 4.1 Biologische Materialschädigung und Referenzorganismen (55)
- 6.0 Abteilungsleitung und andere (51)
- 3 Gefahrgutumschließungen; Energiespeicher (49)
- 1.5 Proteinanalytik (48)
- 7.4 Baustofftechnologie (47)
- 1.8 Umweltanalytik (43)
- 5.2 Metallische Hochtemperaturwerkstoffe (42)
- 4.3 Schadstofftransfer und Umwelttechnologien (41)
- 5.4 Multimateriale Fertigungsprozesse (39)
- 8.6 Faseroptische Sensorik (39)
- 1.9 Chemische und optische Sensorik (38)
- 9.0 Abteilungsleitung und andere (31)
- 7.2 Ingenieurbau (29)
- 8.4 Akustische und elektromagnetische Verfahren (29)
- 4.0 Abteilungsleitung und andere (28)
- 4.2 Material-Mikrobiom Wechselwirkungen (27)
- 5.5 Materialmodellierung (27)
- 5.6 Glas (27)
- 9.2 Versuchsanlagen und Prüftechnik (27)
- S Qualitätsinfrastruktur (24)
- 2 Prozess- und Anlagensicherheit (23)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (23)
- 7.6 Korrosion und Korrosionsschutz (22)
- 9.5 Tribologie und Verschleißschutz (22)
- 9.6 Additive Fertigung metallischer Komponenten (22)
- VP Vizepräsident (22)
- VP.1 eScience (22)
- 2.1 Sicherheit von Energieträgern (21)
- 1.3 Instrumentelle Analytik (19)
- 5.3 Polymere Verbundwerkstoffe (18)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (17)
- 4.5 Kunst- und Kulturgutanalyse (17)
- 1.6 Anorganische Referenzmaterialien (16)
- 5.0 Abteilungsleitung und andere (16)
- 7.1 Baustoffe (15)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (14)
- S.2 Digitalisierung der Qualitätsinfrastruktur (14)
- 1.0 Abteilungsleitung und andere (13)
- 7.7 Modellierung und Simulation (13)
- 3.2 Gefahrguttanks und Unfallmechanik (10)
- P Präsident (10)
- P.0 Präsident und andere (10)
- 6.7 Materialsynthese und Design (9)
- 6.4 Materialinformatik (8)
- 7.0 Abteilungsleitung und andere (8)
- 3.4 Sicherheit von Lagerbehältern (7)
- 3.5 Sicherheit von Gasspeichern (7)
- 3.6 Elektrochemische Energiematerialien (7)
- 7.3 Brandingenieurwesen (7)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (6)
- S.1 Qualität im Prüfwesen (5)
- 4.6 Molekulare und angewandte Entomologie (3)
- 2.2 Prozesssimulation (2)
- 3.0 Abteilungsleitung und andere (2)
- 8.3 Thermografische Verfahren (2)
- 2.0 Abteilungsleitung und andere (1)
- 2.3 Einstufung von Gefahrstoffen und -gütern (1)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (1)
- PST Präsidiale Stabsstelle (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (68)
Geosynthetics are planar polymeric products, which are used in connection with soil, rock or other soil-like materials to fulfill various functions in geoenvironmental engineering. Geosynthetics are of ever-growing importance in the construction industry. Sealing of waste storage facilities to safely prevent the emission of wastewater, landfill gas and contaminated dust as well as the diffusion of pollutants into the environment and coastal protection against storms and floods and reconstruction after natural disaster are important fields of application. We will give an overview of the various geosynthetic products. Two examples of the material problems related to geosynthetics are discussed in detail: the effect of creep on the long-term performance of geocomposite drains and the numerical simulation of the interaction of soil with geogrids. Both issues are of importance for the use of these products in landfill capping systems. The various functions, which geosynthetics may fulfill in the protection of coastal lines, are illustrated by case studies. The geosynthetic market is evaluated and economical and environmental benefits, as well as environmental side effects related to the use of geosynthetics, are discussed.
Quantifying degradation of collagen in ancient manuscripts: the case of the Dead Sea Temple Scroll
(2013)
Since their discovery in the late 1940s, the Dead Sea Scrolls, some 900 ancient Jewish texts, have never stopped attracting the attention of scholars and the broad public alike, because they were created towards the end of the Second Temple period and the 'time of Christ'. Most of the work on them has been dedicated to the information contained in the scrolls' text, leaving physical aspects of the writing materials unexamined. They are, however, crucial for both historical insight and preservation of the scrolls. Although scientific analysis requires handling, it is essential to establish the state of degradation of these valued documents. Polarized Raman Spectroscopy (PRS) is a powerful tool for obtaining information on both the composition and the level of disorder of molecular units. In this study, we developed a non-invasive and non-destructive methodology that allows a quantification of the disorder (that can be related to the degradation) of protein molecular units in collagen fibers. Not restricted to collagen, this method can be applied also to other protein-based fibrous materials such as ancient silk, wool or hair. We used PRS to quantify the degradation of the collagen fibers in a number of fragments of the Temple Scroll (11Q19a). We found that collagen fibers degrade heterogeneously, with the ones on the surface more degraded than those in the core.
Synthesis, structure determination, and formation of a theobromine: oxalic acid 2:1 cocrystal
(2015)
The structure and the formation pathway of a new theobromine : oxalic acid (2 : 1) cocrystal are presented. The cocrystal was synthesised mechanochemically and its structure was solved based on the powder X-ray data. The mechanochemical synthesis of this model compound was studied in situ using synchrotron XRD. Based on the XRD data details of the formation mechanism were obtained. The formation can be described as a self-accelerated ('liquid like') process from a highly activated species.
The objective of the report is to present the state-of-the art of non-destructive testing methods and technologies for the inspection of thick, heavily-reinforced structures, (e.g. found in nuclear power plants). Wall thicknesses can be in excess of one meter and the structures often have increased steel reinforcement density. The accessibility for any testing method may be limited due to the presence of liners and other components such as cast-in-place items. Testing methods have to provide solutions for tasks such as locating failure (inclusions, corrosion, voids, delaminations) in the structures or the assessment of the condition of the structure in general.
Solgel prepared ternary FeF3–MgF2 materials have become promising heterogeneous catalysts due to their porosity and surface Lewis/Brønsted acidity (bi-acidity). Despite the good catalytic performance, nanoscopic characterisations of this type of material are still missing and the key factors controlling the surface properties have not yet been identified, impeding both a better understanding and further development of ternary fluoride catalysts. In this study, we characterised the interaction between the bi-acidic component (FeF3) and the matrix (MgF2) on the nano-scale. For the first time, the formation pathway of FeF3–MgF2 was profiled and the template effect of MgF2 during the synthesis process was discovered. Based on these new insights two novel materials, FeF3–CaF2 and FeF3–SrF2, were established, revealing that with decreasing the atomic numbers (from Sr to Mg), the ternary fluorides exhibited increasing surface acidity and surface area but decreasing pore size. These systematic changes gave rise to a panel of catalysts with tuneable surface and bulk properties either by changing the matrix alkaline earth metal fluoride or by adjusting their ratios to Fe or both. The template effect of the alkaline earth metal fluoride matrix was identified as the most probable key factor determining the surface properties and further influencing the catalytic performance in ternary fluoride based catalysts, and paves the way to targeted design of next-generation catalysts with tunable properties.
Die Synthetic Aperture Focusing Technique (SAFT) ist ein Verfahren zur Verarbeitung von HF-Bildern, die an unterschiedlichen Prüfkopfpositionen aufgenommen wurden. Es wird in der zerstörungsfreien Werkstoffprüfung genutzt, um eine Abbildung von Materialfehlern innerhalb des Gebietes zu erstellen, auf das die Rekonstruktion angewandt wird. Die nach Abschluss der SAFT-Rekonstruktion zusammengestellten Informationen über Reflektoren liegen zunächst nach wie vor in Form von HF-Daten vor. Die Interpretierbarkeit der SAFT-Bilder ist im Allgemeinen davon abhängig, wie diese Daten vor der endgültigen Darstellung aufbereitet werden. Die Bildung der Amplitudeneinhüllenden aus dem zugehörigen analytischen Signal stellt eine Möglichkeit einer solchen Aufbereitung nach Anwendung des SAFT-Algorithmus dar. Sie ist jedoch nur im eindimensionalen Fall eindeutig definiert. In diesem Beitrag wird das Konzept der analytischen Signale mit single-orthant-Spektren aufgegriffen, um eine Detektion der Einhüllenden an mehrdimensionalen HF-Daten durchzuführen. Dabei wird über die Betragsquadrate aller möglichen nach dieser Definition zu bildenden analytischen Signale gemittelt. Es wird gezeigt, dass die Anwendung des beschriebenen Verfahrens einem Separationsansatz entspricht. Außerdem wird eine Möglichkeit aufgezeigt die Gültigkeit dieses Ansatzes anhand der totalen und partiellen Hilberttransformationen des Signals im konkreten Fall zu überprüfen. Die Ergebnisse dieser Methode zur Verbesserung von SAFT Bildern werden unter Verwendung synthetischer und experimenteller Daten an rekonstruierten Abbildungen verschiedener Reflektorarten beispielhaft dargestellt.
The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (Xref). The standard uncertainties associated to the assigned values (uref) were calculated by combining the uncertainty of the characterisation (uchar) with a contribution for homogeneity (ubb) and for stability (ust), whilst uchar was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σp, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39.
In- and quasielastic neutron scattering is employed to investigate both the vibrational density of states and the molecular dynamics of two homologous discotic liquid crystals (DLC) with different length of the alkyl side chain based on a triphenylene derivate. For both compounds characteristic low frequency excess contributions to the vibrational density of states are found. Therefore it is concluded that these liquid crystals show a glass-like behaviour. Elastic scans further show that in these materials a rich molecular dynamics takes place.
Polyglycerol (PG) coated polypropylene (PP) films were synthesized in a two-step approach that involved plasma bromination and subsequently grafting hyperbranched polyglycerols with very few amino functionalities. The influence of different molecular weights and density of reactive linkers were investigated for the grafted PGs. Longer bromination times and higher amounts of linkers on the surface afforded long-term stability. The protein adsorption and bacteria attachment of the PP-PG films were studied. Their extremely low amine content proved to be beneficial for preventing bacteria attachment.
In order to assess the anisotropy-related uncertainties of relatively determined photoluminescence quantum yields (ΦPL) of molecular emitters and luminescent nanomaterials, we compared ΦPL values measured without and with polarizers using magic angle conditions and studied systematically the dependence of the detected emission intensity on the polarizer settings for samples of varying anisotropy. This includes a dispersion of a spherical quantum dot (QD) with an ideally isotropic emission, a solution of a common small organic dye in a fluid solvent as well as dispersions of elongated quantum dot rods (QDR) with an anisotropic luminescence and a small organic dye in a rigid polymeric matrix, as ideally anisotropic emitter. Our results show that for instruments lacking polarizers, anisotropy-related measurement uncertainties of relative photoluminescence quantum yields can amount to more than 40%, with the size of these systematic errors depending on the difference in emission anisotropy between the sample and the standard.
Ergopeptides, like ergocornine and a-ergocryptine, exist in an S- and in an R-configuration. Kinetic experiments imply that certain configurations are preferred depending on the solvent. The experimental methods are explained in this article. Furthermore, computational methods are used to understand this configurational preference. Standard quantum chemical methods can predict the favored configurations by using minimum energy calculations on the potential energy landscape. However, the explicit role of the solvent is not revealed by this type of methods. In order to better understand its influence, classical mechanical molecular simulations are applied. It appears from our research that 'folding' the ergopeptide molecules into an intermediate state (between the S- and the R-configuration) is mechanically hindered for the preferred configurations.
Slicing - a new method for non destructive 3D elemental sensitive characterization of materials
(2014)
Recent advances in synchrotron sources and detector technology have led to substantial improvements in spatial resolution and detection limits for X-ray fluorescence analysis (XRF). However, the non-destructive three-dimensional elemental sensitive characterization of samples remains a challenge. We demonstrate the use of the so-called 'Color X-ray Camera' (CXC) for 3D measurements for the first time. The excitation of the sample is realized with a thin sheet-beam. The stepwise movement of the sample allows getting the elemental distribution for each layer with one measurement. These layers can be combined to a full 3D dataset for each element afterwards. Since the information is collected layer by layer, there is no need to apply reconstruction techniques, which quite often are the reason for artifacts in the results achieved by computed tomography (CT). The field of applications is wide, as the 3D elemental distribution of a material contains clues to processes inside the samples from a variety of origins. The technique is of special interest and well suited for biological specimens, because their light matrix minimizes restricting absorption effects. Measurement examples of a hornet and the teeth of a Sorex araneus are shown.
In this work an air-based sensor network for the localization of persons at extensive areas is presented. The developed network consists of a localization device which the person is wearing (BodyGuard-System), a mobile relay station in the air, and a base station. All three parts communicate with the same radio chip. The BodyGuard-System is an inertial navigation system which was developed for localization in difficult environments with high accuracy and low measurement uncertainty. To increase the range of the system, a multi-hop network was built up. The measured data of the BodyGuard-System and the mobile relay station is visualized on a PC in the base station. This multi-hop network is necessary for example for fire department missions.
The adsorption of porphyrin derivatives on a Au(111) surface was studied by scanning tunneling microscopy and spectroscopy at low temperatures in combination with density functional theory calculations. Different molecular appearances were found and could be assigned to the presence of single gold adatoms bonded by a coordination bond underneath the molecular monolayer, causing a characteristic change of the electronic structure of the molecules. Moreover, this interpretation could be confirmed by manipulation experiments of individual molecules on and off a single gold atom. This study provides a detailed understanding of the role of metal adatoms in surface–molecule bonding and anchoring and of the appearance of single molecules, and it should prove relevant for the imaging of related molecule–metal systems.
Bei der Abschätzung der Beständigkeit von Kunststoffen gegenüber niedermolekularen Flüssigkeiten ist die Kohäsionsenergiedichte CED ein wichtiger Parameter auf molekularer Ebene. Die Vernetzungsdichte ν eines polymeren Festkörpers bildet hierbei einen bedeutsamen Kennwert, der darüber hinaus neben der Löslichkeit wichtige Eigenschaften wie thermische Stabilität und Steifigkeit des Materials charakterisiert. Für die experimentelle Bestimmung von CED und ν eignet sich die Untersuchung des Quellverhaltens in unterschiedlichen Lösungsmitteln. Es werden zwei Messmethoden miteinander verglichen und die Ergebnisse unter Berücksichtigung des molekularen Aufbaus von Proben aus Polyurethan (PU) und hochmolekularem – (HMWPE) und ultrahochmolekularem Polyethylen (UHMWPE) diskutiert. Zum Verständnis des Quellverhaltens dieser Polymerproben in niedermolekularen Lösungsmitteln werden neben den Messergebnissen Literaturdaten zu Grunde gelegt.
We present a systematic study on the effect of surface ligands on the luminescence properties and colloidal stability of β-NaYF4:Yb3+,Er3+ upconversion nanoparticles (UCNPs), comparing nine different surface coatings to render these UCNPs water-dispersible and bioconjugatable. A prerequisite for this study was a large-scale synthetic method that yields ~2 g per batch of monodisperse oleate-capped UCNPs providing identical core particles. These ~23 nm sized UCNPs display an upconversion quantum yield of ~0.35% when dispersed in cyclohexane and excited with a power density of 150 W cm-2, underlining their high quality. A comparison of the colloidal stability and luminescence properties of these UCNPs, subsequently surface modified with ligand exchange or encapsulation protocols, revealed that the ratio of the green (545 nm) and red (658 nm) emission bands determined at a constant excitation power density clearly depends on the surface chemistry. Modifications relying on the deposition of additional (amphiphilic) layer coatings, where the initial oleate coating is retained, show reduced non-radiative quenching by water as compared to UCNPs that are rendered water-dispersible via ligand exchange. Moreover, we could demonstrate that the brightness of the upconversion luminescence of the UCNPs is strongly affected by the type of surface modification, i.e., ligand exchange or encapsulation, yet hardly by the chemical nature of the ligand.
Quantitative determination of acidic surface sites is highly important for the characterization of solid acids because the activity of a catalyst is often related to the concentration of these sites. A recently developed method using 15N Nuclear Magnetic Resonance spectroscopy (NMR) for the quantification of acidic Lewis and Brønsted sites has been tested for a series of nanoscopic aluminum hydroxide fluorides. Comparison with other methods for the quantitative determination of acidic sites shows that this 15N NMR quantification method is a promising technique for the comprehensive investigation of acidic sites. Three different acidic sites, one Brønsted and two Lewis sites, can be distinguished by their 15N chemical shifts of pyridine and simultaneously quantified under conditions corresponding to catalytic reaction conditions. Determination of the individual concentrations of acidic sites allows further insight into the catalytic process. It was found that the concentration of Brønsted sites correlates with catalyzed conversion of citronellal to isopulegol in the investigated series of catalysts. Additionally, investigations indicate that one of the Lewis sites become blocked during the reaction of citronellal.
The digital photography has almost completely substituted the film photography. The film replacement is also fast progressing in medical X-ray radiography. This process is slower in NDT and especially in Europe. Reasons for the hesitating change to digital radiography (RT-D) in NDT are the necessary time for adoption of standards and the conservative request for film RT by auditors and NDT managers for applications in large plants and at construction areas. The fast serial inspection for small castings is already almost completely dominated by RT-D due to the cost effective short exposure and interpretation times. Standards were developed in parallel at CEN, ISO, ASTM and ASME. Unfortunately, the standard practices are different and the requirements on image quality and useable hardware are different too. The first standard series on Computed Radiography were developed and published by CEN and ASTM in 2005. Harmonized classification and qualification standards are available but the published practices are different. ASTM has developed the first standards for application of Digital Detector Arrays (DDA) in 2010. The first digital RT ISO standard practice is ISO 17636-2 (2013), which describes the practice for application of DDAs and Imaging Plates for weld inspection. At the first time this standard provides requirements for the selection of suitable hardware. Minimum image quality requirements are specified in analogy to film radiography and 3 Compensation Principles are defined to enable the application of a wider range of digital detectors. A comparison of the different international digital RT standards is given and first experiences with ISO 17636-2 are discussed. New standards on RT wall thickness and corrosion measurements (EN 16407, film and digital) have been developed recently.
A comparative study on the performance of digital detector systems for high energy applications
(2014)
For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements.
The progress in X-ray detector electronics (sensitivity and speed) allows meanwhile fast single photon detection by a matrix detector. Combined photon counting and energy discrimination is implemented in the electronic circuit of each detector pixel. The company XCounter developed detectors based on CdTe single crystals, which can be tiled to larger areas and have a pixel size of 100ìm. The largest area available in beginning of 2014 is 50x75 mm². These detectors have very promising properties, which make them very suitable for NDT applications:
1. A CdTe attenuation layer of 750 µm thickness allows efficient X-ray detection up to ca. 300 keV. In counting mode only photon noise is important; no other detector noise sources need to be considered. There is no Offset signal without radiation.
2. Each of the detector pixels has two energy thresholds. These can be used for dual energy imaging for materials separation. Also the suppression of scattered radiation by energy thresholding will improve the image contrast sensitivity. First experiments will be presented which demonstrate the advantages of this new detector technology over the conventional charge integrating detectors.
A challenge is the development of a modified detector calibration procedure, which becomes critical at longer exposure times.