Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (2086)
- Beitrag zu einem Tagungsband (386)
- Forschungsbericht (19)
- Beitrag zu einem Sammelband (10)
- Sonstiges (10)
- Buchkapitel (9)
- Corrigendum (3)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Dissertation (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (2290)
- Deutsch (233)
- Mehrsprachig (3)
- Portugiesisch (1)
Schlagworte
- Additive manufacturing (69)
- Fluorescence (56)
- Nanoparticles (48)
- Concrete (47)
- SAXS (46)
- Ultrasound (38)
- Corrosion (37)
- MALDI-TOF MS (36)
- Quantum yield (36)
- Non-destructive testing (34)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (448)
- 6 Materialchemie (442)
- 1 Analytische Chemie; Referenzmaterialien (362)
- 7 Bauwerkssicherheit (228)
- 5 Werkstofftechnik (218)
- 9 Komponentensicherheit (215)
- 4 Material und Umwelt (197)
- 6.3 Strukturanalytik (168)
- 8.5 Röntgenbildgebung (139)
- 6.1 Oberflächen- und Dünnschichtanalyse (102)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (101)
- 8.0 Abteilungsleitung und andere (100)
- 5.1 Mikrostruktur Design und Degradation (80)
- 9.3 Schweißtechnische Fertigungsverfahren (79)
- 1.2 Biophotonik (74)
- 6.6 Physik und chemische Analytik der Polymere (70)
- 9.4 Integrität von Schweißverbindungen (69)
- 8.4 Akustische und elektromagnetische Verfahren (66)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (65)
- 6.2 Material- und Oberflächentechnologien (63)
- 1.1 Anorganische Spurenanalytik (61)
- 7.4 Baustofftechnologie (61)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (57)
- 1.4 Prozessanalytik (56)
- 4.1 Biologische Materialschädigung und Referenzorganismen (56)
- 1.7 Organische Spuren- und Lebensmittelanalytik (55)
- 3 Gefahrgutumschließungen; Energiespeicher (54)
- 1.5 Proteinanalytik (52)
- 6.0 Abteilungsleitung und andere (51)
- 8.6 Faseroptische Sensorik (50)
- 1.8 Umweltanalytik (43)
- 4.3 Schadstofftransfer und Umwelttechnologien (42)
- 5.2 Metallische Hochtemperaturwerkstoffe (42)
- 7.2 Ingenieurbau (40)
- 1.9 Chemische und optische Sensorik (38)
- 5.4 Multimateriale Fertigungsprozesse (38)
- 9.0 Abteilungsleitung und andere (35)
- 9.2 Versuchsanlagen und Prüftechnik (32)
- 4.2 Material-Mikrobiom Wechselwirkungen (31)
- 5.3 Polymere Verbundwerkstoffe (29)
- 2 Prozess- und Anlagensicherheit (28)
- 4.0 Abteilungsleitung und andere (28)
- 4.5 Kunst- und Kulturgutanalyse (28)
- 5.5 Materialmodellierung (27)
- 5.6 Glas (27)
- S Qualitätsinfrastruktur (27)
- 2.1 Sicherheit von Energieträgern (26)
- 7.6 Korrosion und Korrosionsschutz (26)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (24)
- 9.5 Tribologie und Verschleißschutz (23)
- 9.6 Additive Fertigung metallischer Komponenten (23)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (22)
- VP Vizepräsident (22)
- VP.1 eScience (22)
- 7.1 Baustoffe (21)
- 1.3 Instrumentelle Analytik (19)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (17)
- 5.0 Abteilungsleitung und andere (17)
- 1.6 Anorganische Referenzmaterialien (16)
- S.2 Digitalisierung der Qualitätsinfrastruktur (16)
- 7.7 Modellierung und Simulation (15)
- 1.0 Abteilungsleitung und andere (13)
- 7.0 Abteilungsleitung und andere (13)
- P Präsident (11)
- 3.2 Gefahrguttanks und Unfallmechanik (10)
- 3.5 Sicherheit von Gasspeichern (10)
- P.0 Präsident und andere (10)
- 6.7 Materialsynthese und Design (9)
- 7.3 Brandingenieurwesen (9)
- 6.4 Materialinformatik (8)
- 3.4 Sicherheit von Lagerbehältern (7)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (7)
- 3.6 Elektrochemische Energiematerialien (6)
- S.1 Qualität im Prüfwesen (5)
- 3.0 Abteilungsleitung und andere (4)
- 8.3 Thermografische Verfahren (4)
- 4.6 Molekulare und angewandte Entomologie (3)
- 2.0 Abteilungsleitung und andere (2)
- 2.2 Prozesssimulation (2)
- 2.3 Einstufung von Gefahrstoffen und -gütern (1)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (1)
- 3.3 Sicherheit von Transportbehältern (1)
- KM Kommunikation, Marketing (1)
- PST Präsidiale Stabsstelle (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (68)
Efficiency Evaluation of Extraction Methods for Analysis of OCPs and PCBs in Soils of Varying TOC
(2017)
Organochlorine pesticides and polychlorinated biphenyls are toxic, carcinogenic, and have a high potential for bioaccumulation. Due to their stability, they are still considered an environmental problem even though the use of most of them has been phased out several decades ago. Soil is a matrix which can retain these contaminants to a great extent. This ability is often associated with the total organic carbon content (TOC). In order to judge the pollution status of soil and to make monitoring data more easily comparable a simple, yet robust extraction method is needed. Agitation solid-liquid-extraction is well suited for this purpose. However, the influence of TOC on the analyte recovery has to be known. For the presented study, 12 organochlorine pesticides and 7 polychlorinated biphenyls were spiked into four model soils with organic carbon contents between 1.6% - 13.3%. The matrices were extracted using solid-liquid extraction between 45 minutes and 16 hours. For comparison, all soils were also extracted using pressurised liquid extraction and Soxhlet extraction. After clean-up the extracts were measured using a gas chromatography-mass spectrometry (GC-MS) system. Statistical analysis of the results implied that the TOC content of the soils did not have significant influence on the extraction efficiency. A longer solid-liquid extraction time did not necessarily increase analyte recovery: Extraction for one hour resulted in 88% recovery while 16 hour extraction led to 89%. Thus, the efficiency of all the methods was comparable for all model soils. Additional investigations regarding GC liner performance highlighted the need for isotopically labelled standards during the analysis of thermolabile pesticides.
Although the concept of structural water that is bound inside hydrophobic pockets and helps to stabilize protein structures is well established, water has rarely found a similar role in supramolecular polymers. Water is often used as a solvent for supramolecular polymerization, however without taking the role of a comonomer for the supramolecular polymer structure. We report a low–molecular weight monomer whose supramolecular polymerization is triggered by the incorporation of water. The presence of water molecules as comonomers is essential to the polymerization process. The supramolecular polymeric material exhibits strong adhesion to surfaces, such as glass and paper. It can be used as a water-activated glue, which can be released at higher temperatures and reused many times without losing its performance.
Fracture mechanics based component design requires appropriate fracture mechanics toughness data with respect to both, loading rate as well as test temperature. Taking high-rate loading into account such as with accidental scenarios, different standards such as ASTM E 1820 or BS 7448-3 provide some information on dynamic fracture mechanics testing. Nevertheless, the designations differ so that a validation of the own material specific test method used for dynamic R-curve determination is mandatory. In order to address this for ductile cast iron materials an experimental method for the reliable determination of dynamic J-integral crack resistance curves at -40 °C following the multiple specimen approach has been established and validated. The experimental concept offers some additional valuable features. Single values of dynamic crack initiation toughness can be determined using a single specimen technique based on crack sensors. Furthermore, an experimentally independent method is provided according to which CTOD δ5 R-curves can be established. The focus of the present paper is on the validation of the experimental low blow technique using a drop tower test system.
A drop tower test system was developed and set up to perform low blow tests at temperatures down to -40 °C. The system allows for a variation of the impact mass and height and was optimized for testing of ductile cast iron at stress intensity rates from approximately 5∙10⁴ to 3∙10⁵ MPa√ms⁻¹. This range of loading rate is characteristic for instance with crash scenarios of heavy sectioned DCI casks for radioactive materials. In order to address characteristic challenges of impact tests (test duration of microseconds up to milliseconds, inertial effects, signal oscillations), an appropriate full bridge strain gage method for the measurement of force directly on the specimen as well as a non-contact measurement of load line displacement using an optical extensometer have been developed and validated.
The low blow test requires either to prevent bouncing strikes of the hammer by using the stop block technique or to catch the hammer after its first strike. Both options are not part of the experimental concept and setup which have been realized here. The paper describes investigations which have been performed in order to make sure that bouncing strikes of the hammer do not cause additional crack extension in the specimen. This is necessary to ensure a unique relation between the work done and the achieved crack extension. The investigations covered the analysis of limit loads of the specimen with respect to the measured force. The measured stiffness of the specimen was assessed and signals of crack sensors were analyzed. Furthermore, an analysis of the mechanical behavior of the loading system and the specimen by optical observation was performed. Corresponding results are discussed in the paper. It had finally been proven that additional crack extension in the specimen due to bouncing strikes of the hammer is not to be expected under the given conditions of test setup, material and loading. It can be seen as a major experimental advantage that the striker does not have to be catched after the low blow test.
Quantification of nanoparticle (NP) uptake in cells or tissues is very important for safety assessment. Often, electron microscopy based approaches are used for this purpose, which allow imaging at very high resolution. However, precise quantification of NP numbers in cells and tissues remains challenging. The aim of this study was to present a novel approach, that combines precise quantification of NPs in individual cells together with high resolution imaging of their intracellular distribution based on focused ion beam/ scanning electron microscopy (FIB/SEM) slice and view approaches.
The structural and magnetic properties of magnetic multi-core particles were determined by numerical inversion of small angle scattering and isothermal magnetisation data. The investigated particles consist of iron oxide nanoparticle cores (9 nm) embedded in poly(styrene) spheres (160 nm). A thorough physical characterisation of the particles included transmission electron microscopy, X-ray diffraction and asymmetrical flow field-flow fractionation. Their structure was ultimately disclosed by an indirect Fourier transform of static light scattering, small angle X-ray scattering and small angle neutron scattering data of the colloidal dispersion. The extracted pair distance distribution functions clearly indicated that the cores were mostly accumulated in the outer surface layers of the poly(styrene) spheres. To investigate the magnetic properties, the isothermal magnetisation curves of the multi-core particles (immobilised and dispersed in water) were analysed. The study stands out by applying the same numerical approach to extract the apparent moment distributions of the particles as for the indirect Fourier transform. It could be shown that the main peak of the apparent moment distributions correlated to the expected intrinsic moment distribution of the cores. Additional peaks were observed which signaled deviations of the isothermal magnetisation behavior from the non-interacting case, indicating weak dipolar interactions.
The paper presents a new method for the determination and evaluation of tafel factors using gel-type electrolytes and electrochemical frequency modulation technique (EFM). This relatively new electrochemical method offers the possibility to determine both polarization resistances and tafel factors within one measurement and in short measuring intervals. Starting from a comprehensive parameter study it is shown that a direct relationship between the two values exists that can be described mathematically. This contribution presents the determined tafel factors for the system gel-type electrolyte/zinc and discusses their applicability and their limits.
Water and aqueous reagents are essential in any biological process or system. But apart from a few special low vapor-pressure cases, liquids have not been accessible to any technique requiring UHV conditions. EnviroESCA opens up this exciting field of applications.
In this paper first results from water based samples are presented as a proof of concept to demonstrate the special capabilities of EnviroESCA analyzing liquid samples. The following solutions were investigated under near ambient pressure conditions: i.) water, ii.) brine, iii.) an oil in water dispersion, iv.) aqueous iron(II) sulfate heptahydrate, and v.) a suspension of nano silver particles in water.
An UCST-type copolymer of acrylamide (AAm) and acrylonitrile (AN) (poly(AAm-co-AN)) was prepared by reversible addition fragmentation chain transfer (RAFT) polymerization and its temperature-induced phase transition and aggregation behaviour studied by turbidimetry, static and dynamic light scattering, small angle neutron scattering (SANS) and cryo-transmission electron microscopy (cryo-TEM) measurements. The phase transition temperature was found to increase with increasing AN content in the copolymer, concentration of the solutions and copolymer chain length. A significant effect was observed onto the phase transition temperature by addition of different electrolytes into the copolymer solution. The copolymer chains were aggregated below the phase transition temperature and disaggregated above it. The size of the aggregates increases with increasing AN contents and concentration of the copolymer solutions below the phase transition temperature. The copolymer chains were expanded and weekly associated in solution above the phase transition temperature. A model is proposed to explain such association–aggregation behaviour of poly(AAm-co-AN) copolymers depending on AN contents and concentration of the copolymer solutions as a function of temperature.
A controlled, reproducible, gram-scale method is reported for the covalent functionalization of graphene Sheets by a one-pot nitrene [2+1] cycloaddition reaction under mild conditions. The reaction between commercially available 2,4,6-trichloro-1,3,5-triazine and sodium azide with thermally reduced graphene oxide (TRGO) results in defined dichlorotriazine-functionalized sheets. The different reactivities of the chlorine substituents on the functionalized graphene allow stepwise post-modification by manipulating the temperature.
This new method provides unique access to defined bifunctional 2D nanomaterials, as exemplified by chiral surfaces and multifunctional hybrid architectures.
Recently, there has been a rise in freshwater harmful algal blooms (HABs) globally, as well as increasing aquaculture practices. HABs can produce cyanotoxins, many of which are hepatotoxins. An ultra-performance liquid chromatography tandem mass spectrometry method was developed and validated for nine cyanotoxins across three classes including six microcystins, nodularin, cylindrospermopsin and anatoxin-a. The method was used to analyse free cyanotoxin(s) in muscle (n = 34), liver (n = 17) and egg (n = 9) tissue samples of 34 fish sourced from aquaculture farms in Southeast Asia. Conjugated microcystin was analysed by Lemieux oxidation to ascertain the total amount of microcystin present in muscle. Some tilapia accumulated free microcystin-LR in the muscle tissue at a mean of 15.45 μg/kg dry weight (dw), with total microcystin levels detected at a mean level of 110.1 μg/kg dw, indicating that the amount of conjugated or masked microcystin present in the fish muscle accounted for 85% of the total. Higher levels of cyanotoxin were detected in the livers, with approximately 60% of those tested being positive for microcystin-LR and microcystin-LF, along with cylindrospermopsin. Two fish from one of the aquaculture farms contained cylindrospermopsin in the eggs; the first time this has been reported. The estimated daily intake for free and total microcystins in fish muscle tissue was 2 and 14 times higher, respectively, than the tolerable daily intake value. This survey presents the requirement for further monitoring of cyanotoxins, including masked microcystins, in aquaculture farming in these regions and beyond, along with the implementation of guidelines to safeguard human health.