A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background Signals (backlight) of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beers law in single projections (radiographs).
When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation Phase and the samples aspect ratio (dynamics). The magnitude of the diffuse Background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shaded area and the stronger the total attenuation.
Moreover, the local intensity mismatch depends on the attenuation of the sample.
We present very basic reference data measured with multiple metal foils at a synchrotron radiation source. Beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure assumes a constant (non-local) scattering mechanism.
In den unterschiedlichsten Methoden der Computertomographie tritt häufig ein diffuses Untergrundsignal in den Einzelprojektionen auf: im Falle der Parallelstrahl-CT mit Synchrotronstrahlung handelt es sich um ein Hinterleuchten durch den Fluoreszenzschirm, der vor der CCD-Kamera angeordnet ist. Dieses Hinterleuchten unterscheidet sich von dem bekannten Nachleuchten (Phosphoreszenz) durch zeitliche Konstanz.
Hier äußert sich das Hinterleuchten als Modulation der projizierten Masse und somit als Funktion der Phase (Projektionswinkel) und des Aspektverhältnisses des Objektes. Der Einfluss des Hinterleuchtens ist abhängig von der Größe des von der Probe abgeschatteten Detektorbereiches und des Objektumfangs (Dynamik). Dies hat u.a. zur Folge, dass Abweichungen vom Absorptionsgesetz auftreten, die umso
stärker ausgeprägt sind, je weniger Detektorfläche das Objekt abdeckt und je stärker das Objekt schwächt. Dabei können Aufhärtungseffekte wegen der monochromatischen Strahlung ausgeschlossen werden.
Mit Referenzmessungen und einem isotropen, homogenen Ansatz, der diese Abweichung als Hinterleuchten beschreibt, lassen sich die auftretenden Fehler deutlich verringern.
Es wird ein Verfahren zur Röntgenabbildung schwach absorbierender Objekte vorgestellt. Als kontrastgebender Effekt wird die Röntgenrefraktion an Ober- und Grenzflächen ausgenutzt. Zur Erzeugung eines sogenannten Dunkelfeldes wird ein schwach gekrümmter Transmissionskristall eingesetzt, der lokal, d.h. in einem kleinen Ausschnitt des Einstrahlquerschnitts, die Bragg-Bedingung erfüllt. Innerhalb dieser Zone erscheinen die durch Refraktion abgelenkten Strahlkomponenten als hell leuchtende Interface-Strukturen. Die Synthese mehrerer Dunkelfeldstreifen ergibt hochaufgelöste 2D Beispiel von biologischen und technischen Mikrostrukturen.
Die durch Brechung an Mikrostrukturen abgelenkte Röntgenstrahlung wird direkt zweidimensional abgebildet. Dazu werden Modellproben einfacher Geometrie (Fasern, Kapillaren, monodisperse Nano- und Mikropartikel) mit einem auf 50 µm kollimierten Synchrotronstrahl (20 keV) gescannt. Die nach den Regeln der geometrischen Optik an prismatischen und linsenartigen Grenzflächen abgelenkte Strahlung wird in etwa 3 Metern Entfernung von einem Flächendetektor mit 7 µm Ortsauflösung zusätzlich zu der ungestörten Resttransmission des Primärstrahls registriert. In der Abfolge der Radiogramme werden die lokalen Orientierungsänderungen der Probekörper-Grenzflächen bei deren Abtastung mit wenigen Mikrometern Schrittweite bildhaft verfolgt. Mit der hier erreichten Winkelauflösung von etwa 3 Bogensekunden (Streuvektor-Inkremente Δk = 10-3nm-1) kann bei 50 µm Ortsauflösung das Materialvolumen bezüglich innerer Grenzflächen mit Nanometer-Separation auch bei hohen Abtastraten unterhalb einer Sekunde pro Bild charakterisiert werden.
Bikontinuierliche poröse Keramiken für Filteranwendungen weisen eine komplizierte Mikrostruktur auf, in der Poren und Festkörperphase 'vermischt' sind. Mechanische, thermische sowie Filtereigenschaften können nur präzise bestimmt werden, wenn die Morphologie beider Phasen quantitativ angegeben werden kann. Hier werden unter Anwendung von 3D Computertomographie (CT) und verschiedenen Techniken, die auf der Röntgenrefraktion basieren, die Porosität und die Porenorientierung in keramischen Cordierit-Dieselpartikelfiltern bewertet. Dabei werden zur Auswertung der Tomogramme die Fouriertransformierten sowie eine neu entwickelte richtungssensitive Bildanalyse (DIVA, directional interface variance analysis) angewandt. Sowohl die genannten Messtechniken als auch der statistische Ansatz gestatten die Extraktion optional ortsaufgelöster oder gemittelter Werte. Es ergeben sich sehr gute Übereinstimmungen der experimentell ermittelten Porositätswerte mit Ergebnissen aus Quecksilberintrusionsversuchen als auch der ermittelten Porenorientierung im Vergleich zu publizierten Angaben zur kristallographischen Textur. Dies legt den Schluss nahe, dass die Kenntnis der Grenzflächen (zwischen Poren und Materie) genügt, die morphologischen Eigenschaften solcher Materialien hinreichend zu beschreiben.
Grating interferometric set-ups have been established in the last decade. They are promising candidates to obtain enhanced image contrast from weakly absorbing micro and nano structures. They are based on X-ray refraction and near-field diffraction using the Talbot effect.
At the expense of taking multiple images, Talbot-Lau grating interferometry allows separating the absorption, refraction, and scattering contributions by analysing the disturbances of a phase grating interference pattern. Contrary to other refraction enhanced methods, this technique can be applied using conventional X-ray tubes (divergent, polychromatic source). This makes it attractive to solve typical non-destructive testing problems.
We investigated the efficiency of phase gratings, i.e. the visibility (the amplitude of oscillations) upon variation of propagation distance and phase grating rotation around an axis parallel to the grid lines. This grating rotation changes the grating shape (i.e. the distributions of phase shifts). This can yield higher visibilities than derived from rectangular shapes.
Our study includes experimental results obtained from synchrotron radiation, as well as simulations for monochromatic radiation. The advantages of Talbot-Lau interferometry are demonstrated at the example of glass capillaries.
The most substantial innovations in radiographic imaging techniques of the last two decades aim at enhanced image contrast of weakly absorbing micro and nano structures by taking advantage of X-ray refraction effects occurring at outer and inner surfaces. The applications range from fibre reinforced plastics to biological tissues. These techniques comprise, among others, X-ray refraction topography, diffraction enhanced imaging, phase contrast imaging, Talbot-Lau grating interferometry, and refraction enhanced imaging. They all make use of selective beam deflections up to a few minutes of arc: the X-ray refraction effect. In contrast to diffraction, this type of interaction has a 100 % scattering cross section, as shown experimentally. Since X-ray refraction is very sensitive to the orientation of interfaces, it is additionally a tool to detect, e.g., fibre or pore orientation. If the detector resolution exceeds the size of (small) individual features, one detects the integral information (of inner surfaces) within the gauge volume. We describe the above-mentioned techniques, and show their experimental implementation in the lab and at a synchrotron source. We also show strategies for data processing and quantitative analysis.
3D Crack analysis in hydrogen charged lean duplex stainless steel with synchrotron refraction CT
(2016)
Hydrogen in metals can cause a degradation of the mechanical properties, the so-called hydrogen embrittlement. In combination with internal stresses, hydrogen assisted cracking (HAC) can occur. This phenomenon is not completely understood yet. To better characterise the cracking behaviour, it is important to gain information about the evolution of the 3D crack network. For this purpose samples of lean duplex stainless steel were loaded with hydrogen by means of electrochemical charging and investigated by means of synchrotron refraction CT and SEM fractography after uniaxial tensile loading. Synchrotron refraction CT is an analyser-based imaging (ABI) technique. It uses a Si (111) single crystal as analyser, which is placed into the beam path between sample and detector. According to Bragg’s law only incident x-rays within a narrow range around the Bragg-angle are diffracted from the analyser into the detector. Hence, the analyser acts as an angular filter for the transmitted beam. This filtering allows to turn the refraction and scattering of x-rays into image contrast. Refraction occurs at all interfaces, where the density of the material changes and is more sensitive to density changes than the attenuation. Therefore, it is possible to detect smaller cracks than with classical x-ray imaging techniques, like CT, with comparable spacial resolution. It also visualises the 3D structure of the cracks and gains quantitative information about their morphology and distribution. Since cracks introduced by HAC are usually very small and have a small opening displacement, synchrotron refraction CT is expected to be well suited for imaging this cracking mechanism and can be a valuable tool to characterise the formation and the evolution of a 3D crack network.
Proben mit einer Mittelkerbe aus Polyamid 66 mit 35% Gewichtsan-teil an Kurzglasfaser (PA-GF35) wurden im Spritzgießverfahren hergestellt und in einem ungeschädigten und durch Schwingbeanspruch geschädigten Zustand mittels Röntgenverfahren charakterisiert. Sowohl die Faserorientierungsverteilung als auch die Riss-/Mikrorissbildung wurden mit der Röntgenrefraktionstopographie in einem SAXS-Aufbau und dem Diffraction-Enhanced-Imaging am Synchrotron (BESSY II) analysiert. Beide Verfahren spiegeln in guter Übereinstimmung die Charakteristiken dieser Werkstoffklasse in Bezug auf die Fertigungsqualität und die Schädigungsme-chanismen wider.
Im vergangenen Jahrzehnt sind gitterinterferometrische Röntgenabbildungen zunehmend in den Fokus des Interesses gerückt. Sie sind insbesondere dann Vorteil, wenn der in der Standardradiographie erreichbare Kontrast nicht genügt, schwach absorbierende Mikro- und Nanostrukturen abzubilden.
Auf Kosten mehrerer Aufnahmen gestattet die Talbot-Lau Gitterinterferometrie, die Beiträge aus Absorption, Refraktion und (refraktiver) Streuung zu trennen. Dazu werden die Störungen der Interferenzmuster von Phasengittern ausgewertet. Im Gegensatz zu einer Vielzahl anderer refraktionsbasierter Abbildungsmethoden kann diese Technik mit konventionellen Röntgenröhren (mit divergenter, polychromatischer Strahlung) angewendet werden. Damit ist die Technik geeignet, typische ZfP-Fragestellungen zu lösen.
Hier stellen wir Untersuchungen zur Effizienz von Phasengittern vor. Die Visibilität (d.h. die Höhe der Oszillation im Interferenzmuster) wird als Funktion verschiedener geometrischer Parameter verfolgt. Eine Rotation um die Achse parallel zu den Gitterstegen ändert die Form des Gitterprofils (d.h. die Verteilung der Phasenschiebungen). Die kontinuierliche Variation des Winkels und des Detektionsabstandes führt zur Identifikation von ausgezeichneten Kombinationen mit maximaler Visibilität, wobei die Abstände deutlich geringer sind als im Standardaufbau mit senkrechter Gitterbestrahlung.
Unsere Studie umfasst Simulationen für monochromatische Quelle und den Vergleich zu experimentellen Ergebnissen mit der Synchrotronstrahlung.
In der Literatur wurden die Vorteile der Talbot-Lau Interferometrie für die zerstörungsfreie Prüfung von Faserkompositen und Verbundwerkstoffen demonstriert. Hier werden als Beispiele Messungen an Aluminiumtitanat (Al2TiO5) Pulver gezeigt.